Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle flow filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5μm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.

Wozniakiewicz, P. J.↗

Influence of Measurement Uncertainties on Fractional Solubility of Iron in Mineral Aerosols over the Oceans

The atmospheric supply of mineral dust iron (Fe) plays a crucial role in the Earths biogeochemical cycle and is of specific importance as a micronutrient in the marine environment. Observations show several orders of magnitude variability in the fractional solubility of Fe in mineral dust aerosols, making it hard to assess the role of mineral dust for the global ocean biogeochemical Fe cycle. In this study we compare the operational solubility of mineral dust aerosol Fe associated with the flow-through leaching protocol to the results of the global 3-D chemical transport model GEOS-Chem. According to the protocol, aerosol Fe is defined as soluble by first deionized water leaching of mineral dust through a 0.45 m pore size membrane followed by acidification and storage of the leachate over a long period of time prior to analysis. To estimate the uncertainty in soluble Fe results introduced by the flow-through leaching protocol, we prescribe an average 50 (range of 30 to 70) fractional solubility to sub-0.45 m sized mineral dust particles that may inadvertently pass the filter and end up in the acidified (at pH1.7) leachate for a couple of month period. In the model, the fractional solubility of Fe is either explicitly calculated using a complex mineral aerosol Fe dissolution module, or prescribed to be 1 and 4. Calculations show that the fractional solubility of Fe derived through the flow-through leaching is higher compared to the model results. The largest differences (40) are predicted to occur farther away from the dust source regions, over the areas where sub-0.45 m sized mineral dust particles contribute a larger fraction of the total mineral dust mass. This study suggests that different methods used in soluble Fe measurements and inconsistences in the operational definition of filterable Fe in marine environment and soluble Fe in atmospheric aerosols are likely to contribute to the wide range of fractional solubility of aerosol Fe reported in the literature.

Soluble Iron↗

Thermally Actuated Hydraulic Pumps

Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research vessels. Heretofore, electrically actuated hydraulic pumps have been used for this purpose. By eliminating the demand for electrical energy for pumping, the use of the thermally actuated hydraulic pumps could prolong the intervals between battery charges, thus making it possible to greatly increase the durations of undersea exploratory missions.

Jones, Jack↗

Martian Dust Simulator

The Martian Dust Simulator (MDS) was designed to investigate the contamination effects of Martian soil and rock on the performance and function of flight-like microvalves and flight-like filters located within the Sample Analysis at Mars (SAM) instrument suite. The SAM instrument suite, which houses over fifty percent of the science payload, is located on-board the Mars exploration rover. The mission objective of the Mars Science Laboratory Rover is to determine the past, present, and future habitability of Mars. It will serve as a robot geologist, traveling the Mars surface for a period of one Martian year (equivalent to two earth years). The microvalves were designed as a conduit to control the flow of Martian gas to the science instruments. If exposed to particle sizes greater than half a micron, both the science instruments and science equipment, including forty-seven microvalves, could experience performance degradation. As a result, filters were used at various gas inlets to protect flight hardware from particulate degradation. Additionally, the filters serve as the only interface between the Martian environment and the mechanisms within SAM. The MDS operates at 7 Torr (0.135 psi) with a gas flow rate of 0 to 20 m/s. Iron (III) Oxide was the only dust particle specimen used, although several others were initially considered (i.e. JSC-Mars-1, Corundum Powder (Al2O3), Hydrated Sulfate, and Belville (Basalt)). The overarching goal of the MDS is to demonstrate that the Mars exploration program is adequately designed and prepared for the Martian mission environment.

Zuray, Monica↗

Accuracy Study of a 2-Component Point Doppler Velocimeter (PDV)

A two-component Point Doppler Velocimeter (PDV) which has recently been developed is described, and a series of velocity measurements which have been obtained to quantify the accuracy of the PDV system are summarized. This PDV system uses molecular iodine vapor cells as frequency discriminating filters to determine the Doppler shift of laser light which is scattered off of seed particles in a flow. The majority of results which have been obtained to date are for the mean velocity of a rotating wheel, although preliminary data are described for fully-developed turbulent pipe flow. Accuracy of the present wheel velocity data is approximately +/- 1 % of full scale, while linearity of a single channel is on the order of +/- 0.5 % (i.e., +/- 0.6 m/sec and +/- 0.3 m/sec, out of 57 m/sec, respectively). The observed linearity of these results is on the order of the accuracy to which the speed of the rotating wheel has been set for individual data readings. The absolute accuracy of the rotating wheel data is shown to be consistent with the level of repeatability of the cell calibrations. The preliminary turbulent pipe flow data show consistent turbulence intensity values, and mean axial velocity profiles generally agree with pitot probe data. However, there is at present an offset error in the radial velocity which is on the order of 5-10 % of the mean axial velocity.

Kuhlman, John↗

Propulsion system filter sizing considerations for the Galileo spacecraft

Filtration capacity of the Galileo propulsion system has been investigated. Ground testing of flight spare components has been conducted to determine the representative number and size distribution of particulate matter collected in flow tests. For these tests and for filter qualification tests, a number of effects were examined. The influence of gravitational particle settling on ground test results vs the flight environment was considered. Centrifugal effects inherent in the test apparatus and/or the propulsion system could have an influence. Variability among particle sizing techniques was explored. The influence of size distribution, particle shape, and density in the choice of a particulate test material was studied. Characteristics for AC Coarse Dust (an industry standard filter test media), microscopic polymer beads, and aluminum oxide particulate test matter are listed. Filtration tests were conducted using AC Coarse Dust and mixtures containing components of AC Coarse Dust. These results are expected to be useful data for filter sizing of future spacecraft.

Jan, Darrell L.↗

Plasma flow and fast particles in a hypervelocity accelerator - A color presentation

A new concept for particle acceleration for micrometeoroid simulation was developed at NASA Marshall Space Flight Center, using a high-density self-luminescent fast plasma flow to accelerate glass beads (with a diameter up to 1.0 mm) to velocities between 15-20 km/sec. After a short introduction to the operation of the hypervelocity range, the eight-converter-camera unit used for the photographs of the plasma flow and the accelerated particles is described. These photographs are obtained with an eight-segment reflecting pyramidal beam splitter. Wratten filters were mounted between the beam splitter and the converter tubes of the cameras. The photographs, which were recorded on black and white film, were used to make the matrices for the dye-color process, which produced the prints shown.

Igenbergs, E. B.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Advanced Filter Technology For Nuclear Thermal Propulsion

The Scrubber System focuses on using HEPA filters and carbon filtration to purify the exhaust of a Nuclear Thermal Propulsion engine of its aerosols and radioactive particles; however, new technology may lend itself to alternate filtration options, which may lead to reduction in cost while at the same time have the same filtering, if not greater, filtering capabilities, as its predecessors. Extensive research on various types of filtration methods was conducted with only four showing real promise: ionization, cyclonic separation, classic filtration, and host molecules. With the four methods defined, more research was needed to find the devices suitable for each method. Each filtration option was matched with a device: cyclonic separators for the method of the same name, electrostatic separators for ionization, HEGA filters, and carcerands for the host molecule method. Through many hours of research, the best alternative for aerosol filtration was determined to be the electrostatic precipitator because of its high durability against flow rate and its ability to cleanse up to 99.99% of contaminants as small as 0.001 micron. Carcerands, which are the only alternative to filtering radioactive particles, were found to be non-existent commercially because of their status as a "work in progress" at research institutions. Nevertheless, the conclusions after the research were that HEPA filters is recommended as the best option for filtering aerosols and carbon filtration is best for filtering radioactive particles.

Castillon, Erick↗

Application of optical correlation techniques to particle imaging

Pulsed laser sheet velocimetry yields noninstrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usuallay MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the particle image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Application of optical correlation techniques to particle imaging velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization↗

A Scanning laser-velocimeter technique for measuring two-dimensional wake-vortex velocity distributions

A rapid scanning two dimensional laser velocimeter (LV) has been used to measure simultaneously the vortex vertical and axial velocity distributions in the Langley Vortex Research Facility. This system utilized a two dimensional Bragg cell for removing flow direction ambiguity by translating the optical frequency for each velocity component, which was separated by band-pass filters. A rotational scan mechanism provided an incremental rapid scan to compensate for the large displacement of the vortex with time. The data were processed with a digital counter and an on-line minicomputer. Vaporized kerosene (0.5 micron to 5 micron particle sizes) was used for flow visualization and LV scattering centers. The overall measured mean-velocity uncertainity is less than 2 percent. These measurements were obtained from ensemble averaging of individual realizations.

Gartrell, L. R.↗

In situ measurements of light extinction of stratospheric aerosols

The extinction coefficient of ambient aerosol particles was measured using a multiple transverse cell (White Cell) with an effective path length of 100 m. Measurements were performed at seven fixed wavelengths in the visible region using a white light source and an interference filter set with 2 nm bandwidth and center wavelengths of 405.5, 450, 500, 550, 600, 650, and 692.5 nm. The total air flow in the system was 16.7 1/min; the volume of the chamber is close to 10 liters. It takes about one minute to fill the chamber with particles homogeneously, but it needs up to five minutes to get the chamber particle-free. Before measuring the aerosol, the transmission of the particle-free air is determined; then the aerosol passes through the chamber for a period of ten minutes; after this the transmission of particle-free ambient air is measured again for eight minutes. All times are subject to change. At present the measurements are done with a frequency of 1 Hz, but an increase of up to 30 Hz is possible. The lower detection limit of the used White Cell is 3.4 by 10(exp -06) per m. This is sufficient for measuring the extinction coefficient during most tropospheric and some stratospheric conditions. It will be necessary to increase the sensitivity by a factor of ten when measurements under the clearest stratospheric conditions take place.

Metzig, Gunthard↗

Feasibility of automated dropsize distributions from holographic data using digital image processing techniques

An automated technique for measuring particle diameters and their spatial coordinates from holographic reconstructions is being developed. Preliminary tests on actual cold-flow holograms of impinging jets indicate that a suitable discriminant algorithm consists of a Fourier-Gaussian noise filter and a contour thresholding technique. This process identifies circular as well as noncircular objects. The desired objects (in this case, circular or possibly ellipsoidal) are then selected automatically from the above set and stored with their parametric representations. From this data, dropsize distributions as a function of spatial coordinates can be generated and combustion effects due to hardware and/or physical variables studied.

Feinstein, S. P.↗

The function and response of an improved stratospheric condensation nucleus counter

An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.

Wilson, J. C.↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗