Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Particle flow filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hyperfiltration wash water recovery subsystem - Design and test results

The Hyperfiltration Wash Water Recovery (HWWR) subsystem, designed to offer low-power high-volume wash water purification for extended mission spacecraft, is discussed in terms of preprototype design and configuration. Heated wash water collected from the shower, hand wash, and laundry flows into a temperature-controlled (374 K) waste storage tank. Two parallel 25 micron absolute filters at the tank outlet remove large particles from the feed stream. A positive displacement feed pump delivers wash water to the hyperfiltration module at a constant flow rate of 0.20 lpm with discharge pressure variations from 4181-7239 Kpa. The hyperfiltration membrane module is a single-pass design including 36 porous stainless steel tubes, and is designed to provide an approximate water recovery rate of 90 percent. Permeate and brine water flows are monitored by flow meters, and removal of urea and ammonia is achieved by adding 15 percent NaOCl solution to the permeate fluid stream. An alternate module design using two diameters of tubing (allowing a smaller pressure drop and a larger membrane area) gave a superior predicted performance over the first module with larger tubing throughout.

Reysa, R. P.

Pneumatic System for Concentration of Micrometer-Size Lunar Soil

A report describes a size-sorting method to separate and concentrate micrometer- size dust from a broad size range of particles without using sieves, fluids, or other processes that may modify the composition or the surface properties of the dust. The system consists of four processing units connected in series by tubing. Samples of dry particulates such as lunar soil are introduced into the first unit, a fluidized bed. The flow of introduced nitrogen fluidizes the particulates and preferentially moves the finer grain sizes on to the next unit, a flat plate impactor, followed by a cyclone separator, followed by a Nuclepore polycarbonate filter to collect the dust. By varying the gas flow rate and the sizes of various orifices in the system, the size of the final and intermediate particles can be varied to provide the desired products. The dust can be collected from the filter. In addition, electron microscope grids can be placed on the Nuclepore filter for direct sampling followed by electron microscope characterization of the dust without further handling.

McKay, David

NASA Tech Briefs, August 2004

Topics covered include: Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications; Software and Algorithms for Biomedical Image Data Processing and Visualization; Rapid Chemometric Filtering of Spectral Data; Prioritizing Scientific Data for Transmission; Determining Sizes of Particles in a Flow from DPIV Data; Faster Processing for Inverting GPS Occultation Data; FPGA-Based, Self-Checking, Fault-Tolerant Computers; Ultralow-Power Digital Correlator for Microwave Polarimetry; Grounding Headphones for Protection Against ESD; Lightweight Stacks of Direct Methanol Fuel Cells; Highly Efficient Vector-Inversion Pulse Generators; Estimating Basic Preliminary Design Performances of Aerospace Vehicles; Framework for Development of Object-Oriented Software; Analyzing Spacecraft Telecommunication Systems; Collaborative Planning of Robotic Exploration; Tools for Administration of a UNIX-Based Network; Preparing and Analyzing Iced Airfoils; Evaluating Performance of Components; Fuels Containing Methane of Natural Gas in Solution; Direct Electrolytic Deposition of Mats of MnxOy Nanowires; Bubble Eliminator Based on Centrifugal Flow; Inflatable Emergency Atmospheric-Entry Vehicles; Lightweight Deployable Mirrors with Tensegrity Supports; Centrifugal Adsorption Cartridge System; Ultrasonic Apparatus for Pulverizing Brittle Material; Transplanting Retinal Cells using Bucky Paper for Support; Using an Ultrasonic Instrument to Size Extravascular Bubbles; Coronagraphic Notch Filter for Raman Spectroscopy; On-the-Fly Mapping for Calibrating Directional Antennas; Working Fluids for Increasing Capacities of Heat Pipes; Computationally-Efficient Minimum-Time Aircraft Routes in the Presence of Winds; Liquid-Metal-Fed Pulsed Plasma Thrusters; Personal Radiation Protection System; and Attitude Control for a Solar-Sail Spacecraft.

Source record

Characterization of a Regenerable Impactor Filter for Spacecraft Cabin Applications

Regenerable filters will play an important role in human exploration beyond low-Earth orbit. Life Support Systems aboard crewed spacecrafts will have to operate reliably and with little maintenance over periods of more than a year, even multiple years. Air filters are a key component of spacecraft life support systems, but they often require frequent routine maintenance. Bacterial filters aboard the International Space Station require almost weekly cleaning of the pre-filter screen to remove large lint debris captured in the microgravity environment. The source of the airborne matter which is collected on the filter screen is typically from clothing fibers, biological matter (hair, skin, nails, etc.) and material wear. Clearly a need for low maintenance filters requiring little to no crew intervention will be vital to the success of the mission. An impactor filter is being developed and tested to address this need. This filter captures large particle matter through inertial separation and impaction methods on collection surfaces, which can be automatically cleaned after they become heavily loaded. The impactor filter can serve as a pre-filter to augment the life of higher efficiency filters that capture fine and ultrafine particles. A prototype of the filter is being tested at the Particulate Filtration Laboratory at NASA Glenn Research Center to determine performance characteristics, including particle cut size and overall efficiency. Model results are presented for the flow characteristics near the orifice plate through which the particle-laden flow is accelerated as well as around the collection bands.

air filters

Recovery of Oxpure 612C-50 Coconut Carbon Particles Using Bump Arrays

Cyanide is used to leach gold from crushed ore (solid matrix) into a gold cyanide solution. The gold is extracted from the cyanide solution by adsorption onto activated carbon. The gold extraction process occurs when the activated coconut carbon is placed into tanks that contain the gold cyanide solution either in a batch process or into a continuous flow circuit. The coconut carbon is then removed from the solution for gold recovery. The use of the mesofluidic separation system (a deterministic lateral displacement system) can significantly reduce costs and waste generated from the process of removing the coconut carbon from the solution. In the coconut carbon recovery process used at many gold mines in Nevada, the gold is attached to carbon particles that are still in the cyanide liquor. The mesofluidic system can rapidly remove the gold bearing carbon particles from the cyanide liquor quickly and with no operating costs. The benefits include: • Reduce operational costs related to filtration and hydro-cyclones • Reduced acid usage for the elution gold stripping phase as only 25% of the fluids will follow the carbon particles to the final express lane when two mesofluidic systems are used in series This alternative particle removal techniques would be advantageous. A promising technique for removing larger particles from slurries is mesofluidic separation, similar to deterministic lateral displacement arrays or “bump” arrays [1] but operates at much larger flow rates. As described by Pease, et al. [2], “Bump arrays in deterministic lateral displacement devices separate large particles from small particles using arrays of staggered posts. Large particles, defined as those with radii larger than the distance between the edge of a post and the stagnation streamline from the next downstream post, must bump toward one side of the device, whereas particles smaller than this distance slalom from entrance to exit without net lateral displacement.” Unlike filters or sieves, the posts in the arrays that cause separation do not block or occlude particle flow but work because particles go around the posts. Unlike hydrocyclones separation, separation is not driven by particle density, because gravitational forces are unimportant to mesofluidic separation. Burns, et al., and Pease, et al., have shown that particles may be separated from complex suspensions, under turbulent flow conditions, and at industrially important flow rates [3-5]. They have also recently shown that mesofluidic devices may be arranged in series to increase separation performance [6]. In this paper, we evaluate the mesofluidic system for the separation of commercial OxPure GR 612 Charred Coconut shell particles as a proof of principle test for the rapid separation using the 1500 micron cut mesofluidic separator. We first describe the experimental system and conditions. We then present the experimental results. [1] Huang, L.R., E.C. Cox, R.H. Austin, J.C. Sturm. 2004. Continuous particle separation through deterministic lateral displacement. Science, 304, 987–990. https://doi.org/10.1126/science.1094567. [2] Pease L.F., J.A. Bamberger, C.A. Burns, and M.J. Minette. 2021. Large Particle Separation from Non-Newtonian Slurries using Bump Arrays. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-65904, V003T08A023. New York, New York: ASME. doi:10.1115/FEDSM2021-65904 [3] Burns C.A., T.G. Veldman, J. Serkowski, R.C. Daniel, X.-Y. Yu, M.J. Minette, L.F. Pease. 2021. Mesofluidic separation versus dead-end filtration. Separation and Purification Technology, 254, 117256. https://doi.org/10.1016/j.seppur.2020.117256. [4] Pease L.F., J.E. Serkowski, T.G. Veldman, J. Williams, X.-Y. Yu, M.J. Minette, J.A. Bamberger, C.A. Burns. 2021. Can Bump Arrays Separate Particles from Turbulent Flows?. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-67696, V003T08A024. New York, New York: ASME. doi:10.11

mesofluidic separation, slurry, bump array

Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5μm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.

Wozniakiewicz, P. J.

Influence of Measurement Uncertainties on Fractional Solubility of Iron in Mineral Aerosols over the Oceans

The atmospheric supply of mineral dust iron (Fe) plays a crucial role in the Earths biogeochemical cycle and is of specific importance as a micronutrient in the marine environment. Observations show several orders of magnitude variability in the fractional solubility of Fe in mineral dust aerosols, making it hard to assess the role of mineral dust for the global ocean biogeochemical Fe cycle. In this study we compare the operational solubility of mineral dust aerosol Fe associated with the flow-through leaching protocol to the results of the global 3-D chemical transport model GEOS-Chem. According to the protocol, aerosol Fe is defined as soluble by first deionized water leaching of mineral dust through a 0.45 m pore size membrane followed by acidification and storage of the leachate over a long period of time prior to analysis. To estimate the uncertainty in soluble Fe results introduced by the flow-through leaching protocol, we prescribe an average 50 (range of 30 to 70) fractional solubility to sub-0.45 m sized mineral dust particles that may inadvertently pass the filter and end up in the acidified (at pH1.7) leachate for a couple of month period. In the model, the fractional solubility of Fe is either explicitly calculated using a complex mineral aerosol Fe dissolution module, or prescribed to be 1 and 4. Calculations show that the fractional solubility of Fe derived through the flow-through leaching is higher compared to the model results. The largest differences (40) are predicted to occur farther away from the dust source regions, over the areas where sub-0.45 m sized mineral dust particles contribute a larger fraction of the total mineral dust mass. This study suggests that different methods used in soluble Fe measurements and inconsistences in the operational definition of filterable Fe in marine environment and soluble Fe in atmospheric aerosols are likely to contribute to the wide range of fractional solubility of aerosol Fe reported in the literature.

Soluble Iron

Thermally Actuated Hydraulic Pumps

Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research vessels. Heretofore, electrically actuated hydraulic pumps have been used for this purpose. By eliminating the demand for electrical energy for pumping, the use of the thermally actuated hydraulic pumps could prolong the intervals between battery charges, thus making it possible to greatly increase the durations of undersea exploratory missions.

Jones, Jack

Martian Dust Simulator

The Martian Dust Simulator (MDS) was designed to investigate the contamination effects of Martian soil and rock on the performance and function of flight-like microvalves and flight-like filters located within the Sample Analysis at Mars (SAM) instrument suite. The SAM instrument suite, which houses over fifty percent of the science payload, is located on-board the Mars exploration rover. The mission objective of the Mars Science Laboratory Rover is to determine the past, present, and future habitability of Mars. It will serve as a robot geologist, traveling the Mars surface for a period of one Martian year (equivalent to two earth years). The microvalves were designed as a conduit to control the flow of Martian gas to the science instruments. If exposed to particle sizes greater than half a micron, both the science instruments and science equipment, including forty-seven microvalves, could experience performance degradation. As a result, filters were used at various gas inlets to protect flight hardware from particulate degradation. Additionally, the filters serve as the only interface between the Martian environment and the mechanisms within SAM. The MDS operates at 7 Torr (0.135 psi) with a gas flow rate of 0 to 20 m/s. Iron (III) Oxide was the only dust particle specimen used, although several others were initially considered (i.e. JSC-Mars-1, Corundum Powder (Al2O3), Hydrated Sulfate, and Belville (Basalt)). The overarching goal of the MDS is to demonstrate that the Mars exploration program is adequately designed and prepared for the Martian mission environment.

Zuray, Monica

Accuracy Study of a 2-Component Point Doppler Velocimeter (PDV)

A two-component Point Doppler Velocimeter (PDV) which has recently been developed is described, and a series of velocity measurements which have been obtained to quantify the accuracy of the PDV system are summarized. This PDV system uses molecular iodine vapor cells as frequency discriminating filters to determine the Doppler shift of laser light which is scattered off of seed particles in a flow. The majority of results which have been obtained to date are for the mean velocity of a rotating wheel, although preliminary data are described for fully-developed turbulent pipe flow. Accuracy of the present wheel velocity data is approximately +/- 1 % of full scale, while linearity of a single channel is on the order of +/- 0.5 % (i.e., +/- 0.6 m/sec and +/- 0.3 m/sec, out of 57 m/sec, respectively). The observed linearity of these results is on the order of the accuracy to which the speed of the rotating wheel has been set for individual data readings. The absolute accuracy of the rotating wheel data is shown to be consistent with the level of repeatability of the cell calibrations. The preliminary turbulent pipe flow data show consistent turbulence intensity values, and mean axial velocity profiles generally agree with pitot probe data. However, there is at present an offset error in the radial velocity which is on the order of 5-10 % of the mean axial velocity.

Kuhlman, John

Propulsion system filter sizing considerations for the Galileo spacecraft

Filtration capacity of the Galileo propulsion system has been investigated. Ground testing of flight spare components has been conducted to determine the representative number and size distribution of particulate matter collected in flow tests. For these tests and for filter qualification tests, a number of effects were examined. The influence of gravitational particle settling on ground test results vs the flight environment was considered. Centrifugal effects inherent in the test apparatus and/or the propulsion system could have an influence. Variability among particle sizing techniques was explored. The influence of size distribution, particle shape, and density in the choice of a particulate test material was studied. Characteristics for AC Coarse Dust (an industry standard filter test media), microscopic polymer beads, and aluminum oxide particulate test matter are listed. Filtration tests were conducted using AC Coarse Dust and mixtures containing components of AC Coarse Dust. These results are expected to be useful data for filter sizing of future spacecraft.

Jan, Darrell L.

Plasma flow and fast particles in a hypervelocity accelerator - A color presentation

A new concept for particle acceleration for micrometeoroid simulation was developed at NASA Marshall Space Flight Center, using a high-density self-luminescent fast plasma flow to accelerate glass beads (with a diameter up to 1.0 mm) to velocities between 15-20 km/sec. After a short introduction to the operation of the hypervelocity range, the eight-converter-camera unit used for the photographs of the plasma flow and the accelerated particles is described. These photographs are obtained with an eight-segment reflecting pyramidal beam splitter. Wratten filters were mounted between the beam splitter and the converter tubes of the cameras. The photographs, which were recorded on black and white film, were used to make the matrices for the dye-color process, which produced the prints shown.

Igenbergs, E. B.

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.

Advanced Filter Technology For Nuclear Thermal Propulsion

The Scrubber System focuses on using HEPA filters and carbon filtration to purify the exhaust of a Nuclear Thermal Propulsion engine of its aerosols and radioactive particles; however, new technology may lend itself to alternate filtration options, which may lead to reduction in cost while at the same time have the same filtering, if not greater, filtering capabilities, as its predecessors. Extensive research on various types of filtration methods was conducted with only four showing real promise: ionization, cyclonic separation, classic filtration, and host molecules. With the four methods defined, more research was needed to find the devices suitable for each method. Each filtration option was matched with a device: cyclonic separators for the method of the same name, electrostatic separators for ionization, HEGA filters, and carcerands for the host molecule method. Through many hours of research, the best alternative for aerosol filtration was determined to be the electrostatic precipitator because of its high durability against flow rate and its ability to cleanse up to 99.99% of contaminants as small as 0.001 micron. Carcerands, which are the only alternative to filtering radioactive particles, were found to be non-existent commercially because of their status as a "work in progress" at research institutions. Nevertheless, the conclusions after the research were that HEPA filters is recommended as the best option for filtering aerosols and carbon filtration is best for filtering radioactive particles.

Castillon, Erick

Application of optical correlation techniques to particle imaging

Pulsed laser sheet velocimetry yields noninstrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usuallay MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the particle image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.

Application of optical correlation techniques to particle imaging velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization