Examining Thermolytic Production of Hydrogen from Lubrication Oil
Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to conduct testing via Technical Task Request (HR) to determine the thermolytic HGR of Mobil SHC™ 630, a lubrication oil. Currently, 35 gallons of contaminated Mobil SHC 630 is proposed for release into the recycle stream from the Defense Waste Processing Facility (DWPF) to Tank 22 and then to the 242-16H (2H) Evaporator system. Inhibited recycle waste in the Recycle Collection Tank (RCT) is transferred to Recycle Pump Tank (RPT) in the Low Point Pump Pit (LPPP) and then to the Concentration, Storage and Transfer Facilities (CSTF) H-area. The lubrication oil would be added directly to the RPT, bypassing the RCT. The current DWPF waste compliance plan for liquid transfers from the RCT to the CSTF limits the concentration of Mobil SHC 630 to <1,100 ppm which is equal to <9.3 gallons of Mobil SHC 630 when considering a 7,500 gal RCT batch with an initial Mobil SHC 630 concentration of 42 mg/L. Mobil SHC 630 is expected to be largely immiscible in the caustic aqueous waste stream. It is a blend of base oils including polyalphaolefin (PAO) base oil and additives such as triphenylphosphate and cresyl diphenyl phosphate at various concentrations (<0.25 wt%). While the base oils are expected to be largely unreactive in CSTF waste, the triarylphosphates additives would be expected to hydrolyze in the caustic waste, forming diarylphosphates and phenol. The tests described herein were governed by a single Run Plan and will determine thermolytic HGR from the caustic aqueous solution, as well as from any organic phases present.