Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of the Electronic Crosstalk Effect in Terra MODIS Long-Wave Infrared Photovoltaic Bands Using Lunar Images

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the space-view port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27-30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the in-band and out-of-band contribution to the signal contamination for each detector in bands 27-30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27- 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

Wilson, Truman↗

Assessments and Applications of Terra and Aqua MODIS On-Orbit Electronic Calibration

MODIS has 36 spectral bands located on four focal plane assemblies (FPAs), covering wavelengths from 0.41 to 14.4 micrometers. MODIS bands 1-30 collect data using photovoltaic (PV) detectors and, therefore, are referred to as the PV bands. Similarly, bands 31-36 using photoconductive (PC) detectors are referred to as the PC bands.The MODIS instrument was built with a set of on-board calibrators (OBCs) in order to track on-orbit changes of its radiometric, spatial, and spectral characteristics. In addition, an electronic calibration (ECAL) function can be used to monitor on-orbit changes of its electronic responses (gains). This is accomplished via a series of stair step signals generated by the ECAL function. These signals, in place of the FPA detector signals, are amplified and digitized just like the detector signals. Over the entire mission of both Terra and Aqua MODIS,the ECAL has been performed for the PV bands and used to assess their on-orbit performance. This paper provides an overview of MODIS on-orbit calibration activities with a focus on the PV ECAL, including its calibration process and approaches used to monitor the electronic performance. It presents the results derived and lessons learned from Terra and Aqua MODIS on-orbit ECAL. Also discussed are some of the applications performed with the information provided by the ECAL data.

Xiong, Xiaoxiong↗

Unsupervised Classification of Global Radar Units on Venus

Characterization of the Venusian surface in terms of its radar properties was accomplished by application of an unsupervised, linear discriminant algorithm to two Pioneer-Venus (PV) Orbiter radar data sets: the RMS-slope (surface roughness) and reflectivity. Both databases were spatially filtered to the same effective resolution of 100 km prior to classification. A recent supervised classification study using these data was based on presupposed morphologic significance of selected data ranges. The knowledge of both Venusian geology and the geologic significance of the radar data is so limited that the data warrant a more unsupervised approach; for this study a linear discriminant classifier was chosen. This approach is purely statistical, thereby removing any observer bias. Statistical significance of the resulting clusters was evaluated by an ancillary program in which an F test utilizing the Mahalanobis' distance.

Kozak, R. C.↗

Low Intensity Low Temperature (LILT) measurements and coefficients on new photovoltaic structures

Past NASA missions to Mars, Jupiter, and the outer planets were powered by radioisotope thermal generators (RTG's). Although these devices proved to be reliable, their high cost and highly toxic radioactive heat source has made them far less desirable for future planetary missions. This has resulted in a renewed search for alternate energy sources, some of them being photovoltaic (PV) and thermophotovoltaic (TPV). Both of these alternate energy sources convert light/thermal energy directly into electricity. In order to create a viable PV and TPV data base for planetary mission planners and cell designers, we have compiled low temperature low intensity (LILT) I-V data on single junction and multi-junction high efficiency solar cells. The cells tested here represent the latest photovoltaic technology. Using this LILT data to calculate dI(sub SC)/dT, dV(sub OC)/dT, dFF/dT, and also as a function of intensity, an accurate prediction of cell performance under the AMO spectrum can be determined. When combined with QUantum efficiency at Low Temperature (QULT) data, one can further enhance the data by adding spectral variations to the measurements. This paper presents an overview of LILT measurements and is only intended to be used as a guideline for material selection and performance predictions. As single junction and multi-junction cell technologies emerge, new test data must be collected. Cell materials included are Si, GaAs/Ge, GainP/GaAs/Ge, InP, InGaAs/InP, InP/InGaAs/InP, and GainP. Temperatures range as low as -175 C and intensities range from 1 sun to .02 suns.

Schelman, David A.↗

Mir Cooperative Solar Array Project Accelerated Life Thermal Cycling Test

The Mir Cooperative Solar Array (MCSA) project was a joint U.S./Russian effort to build a photovoltaic (PV) solar array and deliver it to the Russian space station Mir. The MCSA will be used to increase the electrical power on Mir and provide PV array performance data in support of Phase 1 of the International Space Station. The MCSA was brought to Mir by space shuttle Atlantis in November 1995. This report describes an accelerated thermal life cycle test which was performed on two samples of the MCSA. In eight months time, two MCSA solar array 'mini' panel test articles were simultaneously put through 24,000 thermal cycles. There was no significant degradation in the structural integrity of the test articles and no electrical degradation, not including one cell damaged early and removed from consideration. The nature of the performance degradation caused by this one cell is briefly discussed. As a result of this test, changes were made to improve some aspects of the solar cell coupon-to-support frame interface on the flight unit. It was concluded from the results that the integration of the U.S. solar cell modules with the Russian support structure would be able to withstand at least 24,000 thermal cycles (4 years on-orbit). This was considered a successful development test.

Hoffman, David J.↗

Evidence for Day-to-Night Ion Transport at Low Solar Activity in the Venus Pre-Dawn Ionosphere

Periapsis of the Pioneer Venus spacecraft 2 dropped below 180 km on August 28, 1992 near midnight, and 42 orbits of low altitude data at moderately low solar activity in the pre-dawn sector were obtained before contact was lost to the spacecraft in October, 1992. Through a combination of analysis of data from the PV orbiter ion mass spectrometer (OIMS) and modeling, we consider here what can be learned about the relative importance of plasma transport from the dayside and electron precipitation in maintaining the nightside ionosphere during the re-entry period. In particular, we examine here the atomic ion density profiles. We compute the average peak density of O(+) as a function of solar zenith angle and determine what fluxes of atomic ions or precipitating electrons would he necessary to produce those values. We then compare model calculations of the ion densities to those observed during the re-entry period. We find that the low solar activity nightside ionosphere shows evidence of significant day-to-night plasma transport.

Brannon, J. F.↗

Thermal Cycling of Mir Cooperative Solar Array (MCSA) Test Panels

The Mir Cooperative Solar Array (MCSA) project was a joint US/Russian effort to build a photovoltaic (PV) solar array and deliver it to the Russian space station Mir. The MCSA is currently being used to increase the electrical power on Mir and provide PV array performance data in support of Phase 1 of the International Space Station (ISS), which will use arrays based on the same solar cells used in the MCSA. The US supplied the photovoltaic power modules (PPMs) and provided technical and programmatic oversight while Russia provided the array support structures and deployment mechanism and built and tested the array. In order to ensure that there would be no problems with the interface between US and Russian hardware, an accelerated thermal life cycle test was performed at NASA Lewis Research Center on two representative samples of the MCSA. Over an eight-month period (August 1994 - March 1995), two 15-cell MCSA solar array 'mini' panel test articles were simultaneously put through 24,000 thermal cycles (+80 C to -100 C), equivalent to four years on-orbit. The test objectives, facility, procedure and results are described in this paper. Post-test inspection and evaluation revealed no significant degradation in the structural integrity of the test articles and no electrical degradation, not including one cell damaged early as an artifact of the test and removed from consideration. The interesting nature of the performance degradation caused by this one cell, which only occurred at elevated temperatures, is discussed. As a result of this test, changes were made to improve some aspects of the solar cell coupon-to-support frame interface on the flight unit. It was concluded from the results that the integration of the US solar cell modules with the Russian support structure would be able to withstand at least 24,000 thermal cycles (4 years on-orbit).

Hoffman, David J.↗

Evidence for Day-to-Night Ion Transport at Low Solar Activity in the Venus Pre-Dawn Ionosphere

Periapsis of the Pioneer Venus spacecraft dropped below 180 km on August 28, 1992 near midnight, and 42 orbits of low altitude data at moderately low solar activity in the pre-dawn sector were obtained before contact was lost to the spacecraft in October, 1992. Through a combination of analysis of data from the PV orbiter ion mass spectrometer (OIMS) and modeling, we consider here what can be learned about the relative importance of plasma transport from the dayside and electron precipitation in maintaining the nightside ionosphere during the re-entry period. In particular, we examine here the atomic ion density profiles. We compute the average peak density of O(+) as a function of solar zenith angle and determine what fluxes of atomic ions or precipitating electrons would be necessary to produce those values. We then compare model calculations of the ion densities to those observed during the re-entry period. We find that the low solar activity nightside ionosphere shows evidence of significant day-to-night plasma transport.

Brannon, J. F.↗

TOMS total ozone trends in potential vorticity coordinates

Global total ozone measurements from the Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) are analyzed using potential vorticity (PV) as an approximate vortex-following coordinate. We analyze the time period November 1978-May 1991, prior to the volcanic eruption of Mt. Pinatubo. The TOMS data are remapped into PV coordinates and trends are calculated, thereby characterizing ozone losses inside and outside the winter polar vortices. These analyses show large regions of ozone loss outside of the vortex in both hemispheres. Furthermore, these data suggest that midlatitude losses in the NH during winter-spring do not result solely from the transport of ozone depleted air from inside to outside the vortex.

Randel, William J.↗

Stratosphere-to-Troposphere Transport Revealed by Ground-based Lidar and Ozonesonde at a Midlatitude Site

This paper presents ozone structures measured by a ground-based ozone lidar and ozonesonde at Huntsville, Alabama, on 27-29 April 2010 originating from a stratosphere-to-troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2-km thick elevated ozone layer with values between 70 and 85 ppbv descending from the 306-K to 298-K isentropic surface at a rate of 5 km day1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2-PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is approximately 41 ppbv/PVU with an uncertainty of approximately 33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 10(exp33) molecules) and 0.11 Tg (1.3 10(exp33) molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid-troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical-resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

Kuang, Shi↗

Analysis of the Pioneer Venus Large Probe Neutral Mass Spectrometer Data Yields New Insights into the Composition of Venus’ Atmosphere

We present a new analysis of mass spectral data obtained by the Pioneer Venus (PV) Large Probe Neutral Mass Spectrometer (LNMS). To analyze the LNMS data, we constructed an analytical model that accounts for spectrometer performance at each altitude, provides CO2 abundances in units of density (kg/m3), and retains the resolving power of the LNMS through use of a targeted data-fitting routine. Our results provide new insights into the composition of Venus’ atmosphere and show that densities for CO2 increase towards the surface, which is suggestive of surface outgassing. Additionally, the data reveal partial obstructions of the LNMS inlet at <17 km, which is an likely important consideration for future missions. Re-analysis of the LNMS data may assist in revealing the past, present and/or future habitability of Venus’ clouds.

mass spectral data↗

Polar Vortex Outbreak Air Transport: Observation using Satellite IR Sounder Derived Ozone Product and Comparison with Model

The Single Field of View (SFOV) Sounder Atmospheric Products (SiFSAP) derived from Cross-track Infrared Sounder (CrIS) on SNPP and JPSS have a spatial resolution ( ~14.5 km) better than most global weather and climate models. Most recent significant improvement in the quality of these products enables us to use these high-resolution observation-based sounding data for weather studies and model evaluation. The aim of this study is to explore the value to use these SFOV products for studying the dynamic transport associated with polar vortex outbreak. In a few cases studies, we used SiFSAP products, especially ozone, as well as the data of wind, geopotential height (GPH) and potential velocity (PV) from the fifth-generation ECMWF reanalysis (ERA5) data, to analyze the variation of total ozone, relative humidity and ozone in different layers, as well as their correlation with GPH and PV. Some comparison of the retrieved temperature and water vapor with ERA5 data, and ozone with the Ozone Mapping and Profiler Suite (OMPS) measurements have also been made. It is found (1) the transport of O3-riched polar air accompanying the polar vortex breakup to lower latitude and lower atmosphere, and (2) the transport path of O3 agreeing well with the path of polar cold air (illustrated using the retrieved RH, wind fields and GPH). These results demonstrate the 3-D structure of O3 distribution as derived from CrIS measurements provides some insights of the cold air transport, and can be used to track the dynamic transport of polar cold air following the outbreak of polar vortex. The observed enhancement of O3 following the polar vortex outbreak also suggests some possible linkage between the tropospheric cold air advected with stratospheric air source.

Xiaozhen Xiong↗

Initial Results from the Floating Potential Measurement Unit aboard the International Space Station

The Floating Potential Measurement Unit (FPMU) is a multi-probe package designed to measure the floating potential of the 1nternational Space Station (ISS) as well as the density and temperature of the local ionospheric plasma environment. The role oj the FPMU is to provide direct measurements of ISS spacecraft charging as continuing construction leads to dramatic changes in ISS size and configuration. FPMU data are used for refinement and validation of the ISS spacecraft charging models used to evaluate the severity and frequency of occurrence of ISS charging hazards. The FPMU data and the models are also used to evaluate the effectiveness of proposed hazard controls. The FPMU consists of four probes: a floating potential probe, two Langmuir probes. and a plasma impedance probe. These probes measure the floating potential of the ISS, plasma density, and electron temperature. Redundant measurements using different probes support data validation by inter-probe comparisons. The FPMU was installed by ISS crewmembers, during an ExtraVehicular Activity, on the starboard (Sl) truss of the ISS in early August 2006, when the ISS incorporated only one 160V US photovoltaic (PV) array module. The first data campaign began a few hours after installation and continued for over five days. Additional data campaigns were completed in 2007 after a second 160V US PV array module was added to the ISS. This paper discusses the general performance characteristics of the FPMU as integrated on ISS, the functional performance of each probe, the charging behavior of the ISS before and after the addition of a second 160V US PV array module, and initial results from model comparisons.

Wright, Kenneth H., Jr.↗

Testing the PV-Theta Mapping Technique in a 3-D CTM Model Simulation

Mapping lower stratospheric ozone into potential vorticity (PV)- potential temperature (Theta) coordinates is a common technique employed to analyze sparse data sets. Ozone transformed into a flow-following dynamical coordinate system is insensitive to meteorological variations. Therefore data from a wide range of times/locations can be compared, so long as the measurements were made in the same airmass (as defined by PV). Moreover, once a relationship between ozone and PV/Theta is established, a full 3D ozone field can be estimated from this relationship and the 3D analyzed PV field. However, ozone data mapped in this fashion can be hampered by noisy PV fields, or "mis-matches" in the resolution and/or exact location of the ozone and PV measurements. In this study, we investigate the PV-ozone relationship using output from a recent 50-year run of the Goddard 3D chemical transport model (CTM). Model constituents are transported using off-line dynamics from the finite volume general circulation model (FVGCM). By using the internally consistent model PV and ozone fields, we minimize noise due to mis-matching and resolution issues. We calculate correlations between model ozone and PV throughout the stratosphere, and test the sensitivity of the technique to initial data resolution. To do this we degrade the model data to that of various satellite instruments, then compare the mapped fields derived from the sub-sampled data to the full resolution model data. With these studies we can determine appropriate limits for the PV-theta mapping technique in latitude, altitude, and as a function of original data resolution.

Frith, Stacey M.↗

Photovoltaic performance models - A report card

Models for the analysis of photovoltaic (PV) systems' designs, implementation policies, and economic performance, have proliferated while keeping pace with rapid changes in basic PV technology and extensive empirical data compiled for such systems' performance. Attention is presently given to the results of a comparative assessment of ten well documented and widely used models, which range in complexity from first-order approximations of PV system performance to in-depth, circuit-level characterizations. The comparisons were made on the basis of the performance of their subsystem, as well as system, elements. The models fall into three categories in light of their degree of aggregation into subsystems: (1) simplified models for first-order calculation of system performance, with easily met input requirements but limited capability to address more than a small variety of design considerations; (2) models simulating PV systems in greater detail, encompassing types primarily intended for either concentrator-incorporating or flat plate collector PV systems; and (3) models not specifically designed for PV system performance modeling, but applicable to aspects of electrical system design. Models ignoring subsystem failure or degradation are noted to exclude operating and maintenance characteristics as well.

Smith, J. H.↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗

Finite grid radius and thickness effects on retarding potential analyzer measured suprathermal electron density and temperature

The effect of finite grid radius and thickness on the electron current measured by planar retarding potential analyzers (RPAs) is analyzed numerically. Depending on the plasma environment, the current is significantly reduced below that which is calculated using a theoretical equation derived for an idealized RPA having grids with infinite radius and vanishingly small thickness. A correction factor to the idealized theoretical equation is derived for the Pioneer Venus (PV) orbiter RPA (ORPA) for electron gasses consisting of one or more components obeying Maxwell statistics. The error in density and temperature of Maxwellian electron distributions previously derived from ORPA data using the theoretical expression for the idealized ORPA is evaluated by comparing the densities and temperatures derived from a sample of PV ORPA data using the theoretical expression with and without the correction factor.

Knudsen, William C.↗

Predetection telemetry analog recording and playback for Pioneer Venus 1978

Prediction telemetry recording and playback capability was implemented in the DSN to meet PV-78 mission requirements. Test data, along with theoretical considerations, gives assurance that the data degradation commitment of 1.5 db will be met, and it is anticipated that in actual performance the design goal of 1.0 db will be met. The major technical problems requiring solution were elimination of image in the OLR and the reduction of analog recorder instabilities. These were solved through the use of single-sideband mixing techniques and the use of newer generation analog recorders.

Kent, S. S.↗