Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PTFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Angularly resolved X-ray photoelectron spectroscopy investigation of PTFE after prolonged space exposure

Monochromatized angularly resolved X-ray photoelectron spectroscopy (ARXPS) was used to study PTFE (Teflon) that had been exposed to an earth orbital environment for approximately six years. The primary interest of the research is on a very reactive component of this environment (atomic oxygen) which, because of the typical orbital velocities of a spacecraft, impinge on exposed surfaces with 5 eV energy. This presentation deals with the method of analysis, the findings as they pertain to a rather complex carbon, oxygen, and fluorine XPS peak analysis, and the character of the valence bands. An improved bias referencing method, based on ARXPS, is also demonstrated for evaluating specimen charging effects. It was found that the polymer molecule tends to resist the atomic oxygen attack by reorienting itself, so that the most electronegative CF3 groups are facing the incoming hyperthermal oxygen atoms. The implications of these findings to ground-based laboratory studies are discussed.

Dalins, I.↗

BRDF Calibration of Sintered PTFE in the SWIR

Satellite instruments operating in the reflective solar wavelength region often require accurate and precise determination of the Bidirectional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in their pre-flight calibrations and ground-based support of on-orbit remote sensing instruments. The Diffuser Calibration Facility at NASA's Goddard Space Flight Center is a secondary diffuser calibration standard after NEST for over two decades, providing numerous NASA projects with BRDF data in the UV, Visible and the NIR spectral regions. Currently the Diffuser Calibration Facility extended the covered spectral range from 900 nm up to 1.7 microns. The measurements were made using the existing scatterometer by replacing the Si photodiode based receiver with an InGaAs-based one. The BRDF data was recorded at normal incidence and scatter zenith angles from 10 to 60 deg. Tunable coherent light source was setup. Broadband light source application is under development. Gray-scale sintered PTFE samples were used at these first trials, illuminated with P and S polarized incident light. The results are discussed and compared to empirically generated BRDF data from simple model based on 8 deg directional/hemispherical measurements.

Georgiev, Georgi T.↗

PTFE-ALUMINUM films serve as neutral density filters

Polytetrafluoroethylene /PTFE/ films coated with aluminum films act as neutral density filters in the wavelength range 0.3 to 2.1 microns. These filters are effective in the calibration of photometric systems.

Burks, H. D.↗

PTFE films with improved flexibility

Development and application of flexible polytetrafluroethylene films for expulsion bladders in spacecraft propellant tanks are described. Flexibility of material is obtained by reducing crystallinity through annealing and quenching in water. Physical and mechanical properties of material are presented.

Muraca, R. F.↗

Detection threshold energy of high energy cascade showers using thermoluminescence PTFE-sheet and hot-gas reader

A new thermoluminescence (TL) sheet was developed as a detector for high energy components in air showers. For the investigation of detection threshold energy for a cascade showeer, TL sheets were exposed at Mt. Fuji with X ray films in emulsion chambers and were scanned by a hot-gas reader. It is concluded that if a gamma ray whose energy is more than 6 TeV enters vertically into lead chambers, the resulting cascade shower is readily detectable at maximum development.

Kino, S.↗

Combustion of PTFE: The effects of gravity on ultrafine particle generation

The objective of this project is to obtain an understanding of the effect of gravity on the toxicity of ultrafine particle and gas phase materials produced when fluorocarbon polymers are thermally degraded or burned. The motivation for the project is to provide a basic technical foundation on which policies for spacecraft health and safety with regard to fire and polymers can be formulated.

McKinnon, Thomas↗

Evaluation of transfer films of Salox M on 440C for HPOTP bearing cage applications, task 119

The objective of the task was to evaluate the suitability of a bronze-filled polytetra fluoroethylene (Salox M) as the cage material in Space Shuttle Main Engine (SSME) high pressure oxygen turbo pump (HPOTP) bearings. The role of the cage pocket material will be to provide a transferred lubricating interface at the ball-race contact region. A series of experiments was conducted which involved block-on-ring tests (the block was the polytetrafluoroethylene (PTFE) -filled material and the ring was through-hardened 440C steel) and high speed traction tests of two 440C disks with one disk rubbed with a PTFE block to generate a transfer film. Measurements included post test visual observations of the condition of the 440C, wear rate measurements of the blocks, and traction measurements between the disks. It was observed that both Salox M and glass-filled PTFE (Armalon) transferred PTFE to 440C at cryogenic temperatures. Bronze is also transferred to uncoated 440C from the Salox M. At room temperature no PTFE transfer was observed in the high speed disk tests due to severe frictional heating, although bronze transfer still occurred with the bronze-PTFE Salox M material. Since the bearing will operate at cryogenic temperature, transfer films are very probable. Salox M wore slightly, although probably tolerably, more than glass-filled PTFE against 440C. However, Salox M is clearly less abrasive to 440C than is the glass-filled material. When the surface layer of PTFE is depleted from the glass-filled material, the glass fibers tend to seriously abrade the steel. This problem does not occur with Salox M. The surface roughness studies indicate that smooth balls are quite reasonable for transfer films. No significant difference in wear rates of the candidate cage materials was observed when the 440C surface finish was increased from 0.025 micron to 0.1 micron cla. At higher levels of roughness, the wear rate increased. Two surface coatings (MoS2 and TiN) were tested. The surface coatings tended to reduce the Salox M wear rate and reduce bronze transfer. PTFE transfer at cryogenic temperatures still occurred with the surface coatings. Two cage design concepts are presented utilizing Salox M material. One design involves a metal-reinforced Salox M cage, while the second design uses Salox M inserts in a metal structure.

Barber, S. A.↗

Adhesion between polymers and evaporated gold and nickel films

To obtain information on the adhesion between metal films and polymeric solids, the adhesion force was measured by means of a tensile pull test. It was found that the adhesion strengths between polymeric solids and gold films evaporated on polymer substrates were (1.11 + or - 0.53) multiplied by 10(6) N/M(2) on PTFE, about 5.49 multiplied by 10(6) N/m(2) on UHMWPE, and 6.54x10(6) on 6/6 nylon. The adhesion strengths for nickel films evaporated on PTFE, UHMWPE, and 6/6 nylon were found to be a factor of 1.7 higher than those for the gold coated PTFE, UHMWPE, and 6/6 nylon. To confirm quantitatively the effect of electron irradiation on the adhesion strength between a PTFE solid and metal films, a tensile pull test was performed on the irradiated PTFE specimens, which were prepared by evaporating nickel or gold on PTFE surfaces irradiated by 2-keV electrons for various times. After irradiation, the adhesion strength increased to (4.92 + or - 0.92)x10(6) N/m(2) for nickel coated PTFE and (1.82 + or - 0.48)x10(6) N/m(2) for gold coated PTFE. The improvement in adhesion for nickel is higher than that for gold.

Yamada, Y.↗

Inexpensive Method for Growing Unidirectional Oriented Materials Using Friction-Transferred Poly(tetrafluoroethylene) Substrates

In recent years, there has been an increasing interest in properties of unidirectional materials grown on highly oriented polymer surfaces such as the poly(tetrafluoroethylene) (PTFE) films coated onto smooth glass surfaces. In this technique, a thin PTFE film is deposited by sliding or rubbing a Teflon bar over a heated glass surface at a specific temperature. Depending on the pressure, temperature and sliding rate the thickness of deposited layers can be varied from 30 A to 150 A. The PTFE-coated substrate is simple yet surprising versatile for oriented growth of many organic, inorganic and polymer. The significant aspect of PTFE films is their unusual ability to molecularly align a wide variety of materials grown onto them from solution, melt or vapor phase deposition, at temperature below the melting point of PTFE (approx. 340 C). The PTFE structure may be derived, in part, from the multitude of ridges forming in the film and these ridges can presumably provide effective nucleation sites to induce the unidirectional growth of variety of materials. Electron diffraction studies of these films revealed that the PTFE macromolecules are oriented parallel to each other along the sliding direction. Direct observation of the film thickness, molecular structure and individual fluorine atoms from these highly oriented films were achieved using atomic force microscopy (AFM). In this paper, we also report the first direct observation of individual fluorine atoms, and the measurement of the fluorine-helix and carbon-helix radii to be 1.70 A and 0.54 A, respectively.

Lee, Jonathan A.↗

Oxygen electrode bifunctional electrocatalyst NiCo2O4 spinel

A significant increase in energy density may be possible if a two-unit alkaline regenerative H2-O2 fuel cell is replaced with a single-unit system that uses passive means for H2O transfer and thermal control. For this single-unit system, new electrocatalysts for the O2 electrode will be required which are not only bifunctionally active but also chemically and electrochemically stable between the voltage range of about 0.7 and 1.5 V. NiCo2O4 spinel is reported to have certain characteristics that make it useful for a study of electrode fabrication techniques. High surface area NiCo2O4 powder was fabricated into unsupported, bifunctional, PTFE-bonded, porous gas fuel cell electrodes by commercial sources using varying PTFE contents and sintering temperatures. The object of this study is to measure the bifunctional activities of these electrodes and to observe what performance differences might result from different commercial electrode fabricators. O2 evolution and O2 reduction data were obtained at 80 C (31 percent KOH). An irreversible reaction (i.e., aging) occurred during O2 evolution at potentials greater than about 1.5 V. Anodic Tafel slopes of 0.06 and 0.12 V/decade were obtained for the aged electrodes. Within the range of 15 to 25 percent, the PTFE content was not a critical parameter for optimizing the electrode for O2 evolution activity. Sintering temperatures between 300 and 340 C may be adequate but heating at 275 C may not be sufficient to properly sinter the PTFE-NiCo2O4 mixture. Electrode disintegration was observed during O2 reduction. Transport of O2 to the NiCo2O4 surface became prohibitive at greater than about -0.02 A/sq cm. Cathodic Tafel slopes of -0.6 and -0.12 V/decade were assumed for the O2 reduction process. A PTFE content of 25 percent (or greater) appears to be preferable for sintering the PTFE-NiCo2O4 mixture.

Fielder, William L.↗

ESCA study of the effect of hydrocarbon contamination on poly(tetrafluoroethylene) exposed to atomic oxygen plasma

The ESCA spectra and data obtained by Morra et al. (1989) on poly(tetrafluoroethylene) (PTFE) exposed to atomic oxygen plasma are closely reexamined. It is shown that the spikes observed in Morra et al. plots of O/C or F/C versus time of the exposure of PTFE to atomic oxygen plasma were not characteristic of PTFE per se but were instead a result of a contamination by hydrocarbon present in their PTFE samples. This was demonstrated experimentally by comparing data derived for a very clean PTFE sample exposed for 10, 20, and 30 min to oxygen plasma with data obtained on PTFE samples with very small amounts of hydrocarbon contamination.

Golub, Morton A.↗

Factors Contributing to Pilot Valve Fuel Seal Extrusion in Orbiter PRCS Thrusters

Extrusion of the polytetrafluoroethylene (PTFE) pilot seal used in the monomethylhydrazine (fuel) valve of the Orbiter Primary Reaction Control System (PRCS) thrusters has been implicated in numerous on-orbit thruster failures and on-ground valve failures. Two extrusion mechanisms have been proposed, one or both may be occurring. The first mechanism is attributed to thermal expansion mismatch between adjacent PTFE and metal parts used in the fuel valve, and is referred to as thermal extrusion. The second mechanism is attributed to nitrogen tetroxide (oxidizer) leakage from the adjacent oxidizer valve on the same thruster during ground turnaround, and is referred to as oxidizer-induced extrusion. Model calculations of PTFE pilot seal in an exact pilot valve configuration show that extrusion can be caused by differential thermal expansion, without the intervening influence of oxidizer. Experimental data on semitrapped PTFE and TFM (modified PTFE) specimens simulating a fuel pilot valve configuration show that thermal extrusion 1) is incremental and irreversible, 2) increases with the size of the thermal excursion, 3) decreases with successive thermal cycling, and 4) is accompanied by gap formation. Both PTFE and TFM exhibit a higher affinity for oxidizer than fuel. The property changes associated with oxidizer uptake may explain why oxidizer seals do not exhibit extrusion. Impression replicas of fuel pilot seals removed from the Orbiter fleet show two types of extrusion: extrusion of the entire seal (loaded extrusion), or extrusion of non-sealing surface (unloaded extrusion). Both extrusion types may arise from differences in service history, rather than in failure mechanism. The plausibility oxidizer-induced extrusion was evaluated. Preliminary calculations suggest that enough energy, heat, or gas may be liberated under certain operational scenarios to cause catastrophic extrusion. However, given the lack of supporting data, conclusions implicating oxidizer leakage as a factor in extrusion must be made with caution.

Waller, J.M.↗

Tissue response to peritoneal implants

Peritoneal implants were fabricated from poly 2-OH, ethyl methacrylate (HEMA), polyetherurethane (polytetramethylene glycol 1000 MW, 1,4 methylene disocynate, and ethyl diamine), and untreated and sputter treated polytetrafluoroethylene (PTFE). The sputter treated PTFE implants were produced by an 8 cm diameter argon ion source. The treated samples consisted of ion beam sputter polished samples, sputter etched samples (to produce a microscopic surface cone texture) and surface pitted samples (produced by ion beam sputtering to result in 50 microns wide by 100 microns deep square pits). These materials were implanted in rats for periods ranging from 30 minutes to 14 days. The results were evaluated with regard to cell type and attachment kinetics onto the different materials. Scanning electron microscopy and histological sections were also evaluated. In general the smooth hydrophobic surfaces attracted less cells than the ion etched PTFE or the HEMA samples. The ion etching was observed to enhance cell attachment, multinucleated giant cell (MNGC) formation, cell to cell contact, and fibrous capsule formation. The cell responsed in the case of ion etched PTFE to an altered surface morphology. However, equally interesting was the similar attachment kinetics of HEMA verses the ion etched PTFE. However, HEMA resulted in a markedly different response with no MNGC's formation, minimal to no capsule formation, and sample coverage by a uniform cell layer.

Picha, G. J.↗

Transfer Lubrication For Cryogenic Bearings

Report presents evaluation of bronze-filled polytetrafluoroethylene (PTFE), known as Salox M, as cage material for ball bearings in high-pressure turbopumps for liquid oxygen. Material evaluated as potentially longer-lived replacement for glass-filled PTFE, known as Armalon. Cage transfers PTFE to balls to form solid lubricant film. However, glass fibers in glass-filled material tend to interfere with transfer. Two cage-design concepts developed; one involves metal-reinforced cage of bronze-filled PTFE; other calls for bronze-filled PTFE inserts in metal structure.

Barber, S. A.↗