Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Entanglement maximization in low-energy neutron-proton scattering

The entanglement properties of neutron-proton scattering are investigated using a measure that counts the number of entangled pairs produced by the action of a scattering operator on a given initial neutron-proton state. All phase shifts relevant for scattering at laboratory energies up to 350 MeV are used. Entanglement is found to depend strongly on the initial state. Entanglement is maximized in very low energy scattering if the initial spin state is | ↑ ↓ >, but not if the initial state is | ↑ ↑ > . At such energies the Hamiltonian obeys Wigner SU(4) symmetry, and an entanglement maximum is a sign of that symmetry. At higher energies the angular dependence of entanglement is strong and the entanglement is large for many scattering angles. Furthermore, the tensor force is shown to play a significant role in producing entanglement at laboratory kinetic energies greater than about 50 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamow shell model description of proton scattering on 18 Ne

Background: The structure of weakly bound/unbound nuclei close to particle drip lines is different from that around the valley of beta stability. A comprehensive description of these systems goes beyond the standard shell model (SM) and demands an open quantum system description of the nuclear many-body system. Purpose: For that purpose, we are using the Gamow shell model (GSM) in this study, which provides a fully microscopic description of bound and unbound nuclear states, nuclear decays, and reactions. Here, we formulate the GSM in coupled-channel (GSM-CC) representation to describe low-energy elastic and inelastic scattering of protons on $\mathrm{^{18}Ne}$. Method: The GSM-CC formalism is applied to a translationally invariant Hamiltonian with an effective finite-range two-body interaction. We discuss in detail the GSM-CC formalism in coordinate space and give the description of the novel equivalent potential method for solving the GSM-CC system of integrodifferential equations. This method is then applied for the description of ($p, p'$) reaction cross-sections. The reactions channels are built by GSM wave functions for the ground state $\mathrm{0^+}$ and the first excited $\mathrm{2^+}$ of $\mathrm{^{18}Ne}$ and a proton wave function expanded in different partial waves. The completeness of this basis is verified by comparing GSM and GSM-CC energies of low-energy resonant states in $\mathrm{^{19}Na}$. The differences between the two calculations provide a measure of the missing configurations in the GSM-CC calculation of low-energy states of $\mathrm{^{19}Na}$ due to the restriction on the number of excited states of $\mathrm{^{18}Ne}$. Results: We present the first application of the GSM-CC formalism for the calculation of excited states of $\mathrm{^{18}Ne}$ and $\mathrm{^{19}Na}$, the excitation function, and the elastic/inelastic differential cross-sections in the $\mathrm{^{18}Ne}$ ($p,p'$) reaction at different energies. This is the first unified description of the spectra and reaction cross-sections in the GSM formalism. The method is shown to be both feasible and accurate. The approximate equivalence of GSM and GSM-CC in describing spectra of $\mathrm{^{19}Na}$ has been demonstrated numerically. Conclusions: The GSM in the coupled-channel representation opens a possibility for the unified description of low-energy nuclear structure and reactions using the same Hamiltonian. While both GSM and GSM-CC can describe energies, widths, and wave functions of the many-body states, the GSM-CC can in addition yield reaction cross-sections. The combined application of GSM and GSM-CC to describe energies of resonant states allows to test the exactitude of calculated cross-sections for a given many-body Hamiltonian.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A procedure for calculation of monitor units for passively scattered proton radiotherapy beams

The purpose of this study is to validate a monitor unit (MU) calculation procedure for passively scattered proton therapy beams. The output dose per MU (d/MU) of a therapeutic radiation beam is traditionally calibrated under specific reference conditions. These conditions include beam energy, field size, suitable depth in water or water equivalent phantom in a low dose gradient region with known relative depth dose, and source to point of calibration distance. Treatment field settings usually differ from these reference conditions leading to a different d/MU that needs to be determined for delivering the prescribed dose. For passively scattered proton beams, the proton specific parameters, which need to be defined, are related to the energy, lateral scatterers, range modulating wheel, spread out Bragg peak (SOBP) width, thickness of any range shifter, the depth dose value relative to the normalization point in the SOBP, and scatter both from the range compensator and inhomogeneity in the patient. Following the custom for photons or electrons, a set of proton dosimetry factors, representing the changes in the d/MU relative to a reference condition, can be defined as the relative output factor (ROF), SOBP factor (SOBPF), range shifter factor (RSF), SOBP off-center factor (SOBPOCF), off-center ratio (OCR), inverse square factor (ISF), field size factor (FSF), and compensator and patient scatter factor (CPSF). The ROF, SOBPF, and RSF are the major contributors to the d/MU and were measured using an ion chamber in water tank during the clinical commissioning of each beam to create a dosimetry beam data table to be used for calculating the monitor units. The following simple formula is found to provide an independent method to determine the d/MU at the point of interest (POI) in the patient, namely, (d/MU)=ROF{center_dot}SOBPF{center_dot}RSF{center_dot}SOBPOCF{center_dot}OCR{center_dot}FSF{center_dot}ISF{center_dot}CPSF. The monitor units for delivering the intended dose (D) to the POI can be obtained from MU=D divide (d/MU). The accuracy and robustness of the above formula were validated by calculating the d/MU in water for many different combinations of beam parameters and comparing it with the corresponding measured d/MU by an ion chamber in a water or water/plastic phantom. This procedure has been in use for MU calculation for patient treatment fields at our facility since May 2006. The differences in the calculated and measured values of the d/MU for 623 distinct fields used for patient treatment during the period of May 2006 to February 2007 are within 2% for 99% of these fields. The authors conclude that an intuitive formula similar to the one used for monitor unit calculation of therapeutic photon beams can be used to compute the monitor units of passively scattered proton therapy beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-591: Measurement and Monte Carlo Simulation of Stray Neutrons in Passive Scattering Proton Therapy: Needs and Challenges

Purpose: Measure stray radiation inside a passive scattering proton therapy facility, compare values to Monte Carlo (MC) simulations and identify the actual needs and challenges. Methods: Measurements and MC simulations were considered to acknowledge neutron exposure associated with 75 MeV ocular or 180 MeV intracranial passively scattered proton treatments. First, using a specifically-designed high sensitivity Bonner Sphere system, neutron spectra were measured at different positions inside the treatment rooms. Next, measurement-based mapping of neutron ambient dose equivalent was fulfilled using several TEPCs and rem-meters. Finally, photon and neutron organ doses were measured using TLDs, RPLs and PADCs set inside anthropomorphic phantoms (Rando, 1 and 5-years-old CIRS). All measurements were also simulated with MCNPX to investigate the efficiency of MC models in predicting stray neutrons considering different nuclear cross sections and models. Results: Knowledge of the neutron fluence and energy distribution inside a proton therapy room is critical for stray radiation dosimetry. However, as spectrometry unfolding is initiated using a MC guess spectrum and suffers from algorithmic limits a 20% spectrometry uncertainty is expected. H*(10) mapping with TEPCs and rem-meters showed a good agreement between the detectors. Differences within measurement uncertainty (10–15%) were observed and are inherent to the energy, fluence and directional response of each detector. For a typical ocular and intracranial treatment respectively, neutron doses outside the clinical target volume of 0.4 and 11 mGy were measured inside the Rando phantom. Photon doses were 2–10 times lower depending on organs position. High uncertainties (40%) are inherent to TLDs and PADCs measurements due to the need for neutron spectra at detector position. Finally, stray neutrons prediction with MC simulations proved to be extremely dependent on proton beam energy and the used nuclear models and cross sections. Conclusion: This work highlights measurement and simulation limits for ion therapy radiation protection applications.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of proton and neutron contributions to the 0$^+_{𝑔⁡𝑠}$ → 2$^+_{1}$ excitations in 42 Si and 44 S using inelastic proton scattering in inverse kinematics and intermediate-energy Coulomb excitation

Here, we have measured the 0$^+_{𝑔⁡𝑠}$ → 2$^+_1$ transition in the neutron-rich 𝑁 = 28 isotope 42 Si using the probes of intermediate-energy Coulomb excitation and inelastic proton scattering in inverse kinematics at the Facility for Rare Isotope Beams with beam particle rates of ≈ 5 particles/s. The results of these two measurements allowed us to determine 𝑀 𝑛 /𝑀 𝑝 , the ratio of the neutron and proton transition matrix elements for the 0$^+_{𝑔⁡𝑠}$ → 2$^+_1$ transition. In addition, we have measured the 0$^+_{𝑔⁡𝑠}$ → 2$^+_1$ transition in the isotone 44 S using inverse kinematics inelastic proton scattering. By comparing the 44 S proton-scattering result with a recent intermediate-energy Coulomb excitation result on the same transition, we were able to determine 𝑀 𝑛 /𝑀 𝑝 for the 0$^+_{𝑔⁡𝑠}$ → 2$^+_1$ transition in this nucleus as well. This work strengthens the evidence that 42 Si has a stable quadrupole deformation in its ground state and that 44 S does not. Both conclusions are further supported by shell-model calculations carried out with the FSU interaction.

39 ≤ A ≤ 58↗

On the possibility for precision measurements of differential cross sections for elastic proton–proton scattering at the Protvino accelerator

Elastic-scattering data were analyzed, and it was concluded on the basis of this analysis that precisionmeasurements of differential cross sections for elastic proton–proton scattering at the accelerator of the Institute for High Energy Physics (IHEP, Protvino, Russia) over a broad momentum-transfer range are of importance and topical interest. The layout of the respective experimental facility detecting the scattered particle and recoil proton and possessing a high momentum-transfer resolution was examined along with the equipment constituting this facility. The facility in question is able to record up to a billion events of elastic proton–proton scattering per IHEP accelerator run (20 days). Other lines of physics research with this facility are briefly discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mechanism of elastic and inelastic proton scattering on a {sup 15}C nucleus in diffraction theory

The amplitudes for elastic and inelastic proton scattering on the neutron-rich nucleus {sup 15}C (to its J{sup {pi}} = 5/2{sup +} level in the latter case) in inverse kinematics were calculated within Glauber diffraction theory. First- and second-order terms were taken into account in the multiple-scattering operator. The {sup 15}C wave function in the multiparticle shell model was used. This made it possible to calculate not only respective differential cross sections but also the contribution of proton scattering on nucleons occurring in different shells. The differential cross sections for elastic and inelastic scattering were calculated at the energies of 0.2, 0.6, and 1 GeV per nucleon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Possibilities of studying the structure of halo nuclei in reactions of quasifree proton scattering at low energies

The possibility of experimentally studying the structure of halo nuclei in reactions induced by quasifree proton scattering on clusters of these nuclei is considered. Quasifree proton scattering on {sup 6}He, {sup 4}He, {sup 4}n, {sup 2}n, and n clusters in inverse kinematics is considered for the example of the {sup 8}He nucleus. Angular and energy distributions of secondaries are obtained for various representations of the cluster structure of the {sup 8}He nucleus. It is clearly shown that, in the angular and energy distributions of secondaries, one can single out regions that receive dominant contributions from reactions on specific clusters and which correspond to concrete cluster configurations of halo nuclei. Possible relevant experiments are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-214: Intensity Modulated Proton Therapy (IMPT) Based On Passively Scattered Protons and Multi-Leaf Collimation: Prototype TPS and Dosimetry Study

Purpose. Intensity-modulated proton therapy is usually implemented with multi-field optimization of pencil-beam scanning (PBS) proton fields. However, at the view of the experience with photon-IMRT, proton facilities equipped with double-scattering (DS) delivery and multi-leaf collimation (MLC) could produce highly conformal dose distributions (and possibly eliminate the need for patient-specific compensators) with a clever use of their MLC field shaping, provided that an optimal inverse TPS is developed. Methods. A prototype TPS was developed in MATLAB. The dose calculation process was based on a fluence-dose algorithm on an adaptive divergent grid. A database of dose kernels was precalculated in order to allow for fast variations of the field range and modulation during optimization. The inverse planning process was based on the adaptive simulated annealing approach, with direct aperture optimization of the MLC leaves. A dosimetry study was performed on a phantom formed by three concentrical semicylinders separated by 5 mm, of which the inner-most and outer-most were regarded as organs at risk (OARs), and the middle one as the PTV. We chose a concave target (which is not treatable with conventional DS fields) to show the potential of our technique. The optimizer was configured to minimize the mean dose to the OARs while keeping a good coverage of the target. Results. The plan produced by the prototype TPS achieved a conformity index of 1.34, with the mean doses to the OARs below 78% of the prescribed dose. This Result is hardly achievable with traditional conformal DS technique with compensators, and it compares to what can be obtained with PBS. Conclusion. It is certainly feasible to produce IMPT fields with MLC passive scattering fields. With a fully developed treatment planning system, the produced plans can be superior to traditional DS plans in terms of plan conformity and dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

Extraction of the proton radius from electron-proton scattering data

We perform a new analysis of electron-proton scattering data to determine the proton electric and magnetic radii, enforcing model-independent constraints from form factor analyticity. A wide-ranging study of possible systematic effects is performed. An improved analysis is developed that rebins data taken at identical kinematic settings and avoids a scaling assumption of systematic errors with statistical errors. Employing standard models for radiative corrections, our improved analysis of the 2010 Mainz A1 Collaboration data yields a proton electric radius r E = 0.895(20) fm and magnetic radius r M = 0.776(38) fm. A similar analysis applied to world data (excluding Mainz data) implies r E = 0.916(24) fm and r M = 0.914(35) fm. The Mainz and world values of the charge radius are consistent, and a simple combination yields a value r E = 0.904(15) fm that is 4σ larger than the CREMA Collaboration muonic hydrogen determination. The Mainz and world values of the magnetic radius differ by 2.7σ, and a simple average yields r M = 0.851(26) fm. As a result, the circumstances under which published muonic hydrogen and electron scattering data could be reconciled are discussed, including a possible deficiency in the standard radiative correction model which requires further analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential Cross Section for Elastic Deuteron–Proton Scattering at the Energy of 700 MeV per Nucleon

The results of measurements of the differential cross section for elastic deuteron–proton scattering at the energy of 700 MeV per nucleon that were performed at the internal target station of the nuclotron at the Joint Institute for Nuclear Research (JINR, Dubna) are presented. These data were obtained at angles in the range between 70◦ and 120◦ in the c.m. frame. The angular dependence obtained in this way is compared with world-averaged data at similar energies and with the results of theoretical calculations performed within the relativistic theory of multiple scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Neutron Dose Equivalent and its Dependence on Beam Configuration for a Passive Scattering Proton Delivery System

Purpose: To measure the neutron dose equivalent per therapeutic proton dose (H/D) in a passive scattering proton therapy system and study its dependence on the proton energy, aperture-to-isocenter distance, spread-out Bragg peak (SOBP) width, and field size. Methods and Materials: We performed four experiments of varying proton energies, aperture-to-isocenter distances, SOBP widths, and field sizes. Etched track detectors were used to measure the neutron dose equivalent at both an in-field (isocenter, beyond the protons' range) and out-of-field (30 cm lateral to the isocenter) location in air. Results: For a nonmodulated beam with all the protons stopping in the aperture and an aperture-to-isocenter distance of 30 cm, the H/D values measured at the isocenter were approximately 0.3 mSv/Gy for all snouts with a 100-MeV beam. The H/D values increased to 10.7, 14.5, and 15.1 mSv/Gy, respectively, for small, medium, and large snouts when the beam energy increased to 250 MeV. At the out-of-field location, H/D values increased from 0.1 to 2.7, 3.0, and 3.2 mSv/Gy, respectively, for small, medium, and large snouts. When the aperture-to-isocenter distance was changed from 10 to 40 cm, the H/D value at the isocenter dropped 70%. The H/D value doubled for the modulated beam relative to the nonmodulated beam. Open apertures reduced the neutrons produced in the nozzle, but increased those produced in the phantom. Conclusions: Our data showed that changes in the four factors studied affect the H/D value in predictable ways which permits an estimate of a patient's neutron exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-143: Implementation of a Correction-Based Output Model for a Compact Passively Scattered Proton Therapy System

Purpose: To commission and investigate the accuracy of an output (cGy/MU) prediction model for a compact passively scattered proton therapy system. Methods: A previously published output prediction model (Sahoo et al, Med Phys, 35, 5088–5097, 2008) was commissioned for our Mevion S250 proton therapy system. This model is a correction-based model that multiplies correction factors (d/MUwnc=ROFxSOBPF xRSFxSOBPOCFxOCRxFSFxISF). These factors accounted for changes in output due to options (12 large, 5 deep, and 7 small), modulation width M, range R, off-center, off-axis, field-size, and off-isocenter. In this study, the model was modified to ROFxSOBPFxRSFxOCRxFSFxISF-OCFxGACF by merging SOBPOCF and ISF for simplicity and introducing a gantry angle correction factor (GACF). To commission the model, outputs over 1,000 data points were taken at the time of the system commissioning. The output was predicted by interpolation (1D for SOBPF, FSF, and GACF; 2D for RSF and OCR) with inverse-square calculation (ISF-OCR). The outputs of 273 combinations of R and M covering total 24 options were measured to test the model. To minimize fluence perturbation, scattered dose from range compensator and patient was not considered. The percent differences between the predicted (P) and measured (M) outputs were calculated to test the prediction accuracy ([P-M]/Mx100%). Results: GACF was required because of up to 3.5% output variation dependence on the gantry angle. A 2D interpolation was required for OCR because the dose distribution was not radially symmetric especially for the deep options. The average percent differences were −0.03±0.98% (mean±SD) and the differences of all the measurements fell within ±3%. Conclusion: It is concluded that the model can be clinically used for the compact passively scattered proton therapy system. However, great care should be taken when the field-size is less than 5×5 cm{sup 2} where a direct output measurement is required due to substantial output change by irregular block shape.

60 APPLIED LIFE SCIENCES↗

SU-E-T-287: Robustness Study of Passive-Scattering Proton Therapy in Lung: Is Range and Setup Uncertainty Calculation On the Initial CT Enough to Predict the Plan Robustness?

Purpose: Plan robustness of the passive-scattering proton therapy treatment of lung tumors has been studied previously using combined uncertainties of 3.5% in CT number and 3 mm geometric shifts. In this study, we investigate whether this method is sufficient to predict proton plan robustness by comparing to plans performed on weekly verification CT scans. Methods: Ten lung cancer patients treated with passive-scattering proton therapy were randomly selected. All plans were prescribed 6660cGy in 37 fractions. Each initial plan was calculated using +/− 3.5% range and +/− 0.3cm setup uncertainty in x, y and z directions in Eclipse TPS(Method-A). Throughout the treatment course, patients received weekly verification CT scans to assess the daily treatment variation(Method-B). After contours and imaging registrations are verified by the physician, the initial plan with the same beamline and compensator was mapped into the verification CT. Dose volume histograms (DVH) were evaluated for robustness study. Results: Differences are observed between method A and B in terms of iCTV coverage and lung dose. Method-A shows all the iCTV D95 are within +/− 1% difference, while 20% of cases fall outside +/−1% range in Method-B. In the worst case scenario(WCS), the iCTV D95 is reduced by 2.5%. All lung V5 and V20 are within +/−5% in Method-A while 15% of V5 and 10% of V20 fall outside of +/−5% in Method-B. In the WCS, Lung V5 increased by 15% and V20 increased by 9%. Method A and B show good agreement with regard to cord maximum and Esophagus mean dose. Conclusion: This study suggests that using range and setup uncertainty calculation (+/−3.5% and +/−3mm) may not be sufficient to predict the WCS. In the absence of regular verification scans, expanding the conventional uncertainty parameters(e.g., to +/−3.5% and +/−4mm) may be needed to better reflect plan actual robustness.

60 APPLIED LIFE SCIENCES↗

Intensity-Modulated Proton Therapy Reduces the Dose to Normal Tissue Compared With Intensity-Modulated Radiation Therapy or Passive Scattering Proton Therapy and Enables Individualized Radical Radiotherapy for Extensive Stage IIIB Non-Small-Cell Lung Cancer: A Virtual Clinical Study

Purpose: To compare dose volume histograms of intensity-modulated proton therapy (IMPT) with those of intensity-modulated radiation therapy (IMRT) and passive scattering proton therapy (PSPT) for the treatment of stage IIIB non-small-cell lung cancer (NSCLC) and to explore the possibility of individualized radical radiotherapy. Methods and Materials: Dose volume histograms designed to deliver IMRT at 60 to 63 Gy, PSPT at 74 Gy, and IMPT at the same doses were compared and the use of individualized radical radiotherapy was assessed in patients with extensive stage IIIB NSCLC (n = 10 patients for each approach). These patients were selected based on their extensive disease and were considered to have no or borderline tolerance to IMRT at 60 to 63 Gy, based on the dose to normal tissue volume constraints (lung volume receiving 20 Gy [V20] of <35%, total mean lung dose <20 Gy; spinal cord dose, <45 Gy). The possibility of increasing the total tumor dose with IMPT for each patient without exceeding the dose volume constraints (maximum tolerated dose [MTD]) was also investigated. Results: Compared with IMRT, IMPT spared more lung, heart, spinal cord, and esophagus, even with dose escalation from 63 Gy to 83.5 Gy, with a mean MTD of 74 Gy. Compared with PSPT, IMPT allowed further dose escalation from 74 Gy to a mean MTD of 84.4 Gy (range, 79.4-88.4 Gy) while all parameters of normal tissue sparing were kept at lower or similar levels. In addition, IMPT prevented lower-dose target coverage in patients with complicated tumor anatomies. Conclusions: IMPT reduces the dose to normal tissue and allows individualized radical radiotherapy for extensive stage IIIB NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying of the neutron halo structure in quasi-free proton scattering from {sup 6}He Halo nucleus

An experimental method based on an analysis of the neutron-neutron correlations in reactions induced by halo nuclei in nuclear photoemulsion is proposed for studying the two-neutron halo structure. Photoemulsion stacks were exposed to a beam of radioactive {sup 6}He nuclei. Preliminary data on interaction of the {sup 6}He halo nucleus to hydrogen are compared with the results of the kinematic calculation for the reaction of quasi-free proton scattering from clusters making up the {sup 6}He halo nucleus. A fraction of quasi-free scattering events with 'survival' of the dineutron is evaluated for scattering of protons by the dineutron configuration of the {sup 6}He nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Proton Charge Radius from Electron–Proton Scattering

In light of the proton radius puzzle, the discrepancy between measurements of the proton charge radius from muonic hydrogen and those from electronic hydrogen and electron–proton (e–p) scattering measurements, we re-examine the charge radius extractions from electron scattering measurements. We provide a recommended value for the proton root-mean-square charge radius, r{sub E} = 0.879 ± 0.011 fm, based on a global examination of elastic e–p scattering data. The uncertainties include contributions to account for tension between different data sets and inconsistencies between radii using different extraction procedures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery

Proton radiotherapy centers that currently use passively scattered proton beams do field specific calibrations for a non-negligible fraction of treatment fields, which is time and resource consuming. Our improved understanding of the passive scattering mode of the IBA universal nozzle, especially of the current modulation function, allowed us to re-commission our treatment control system for accurate delivery of SOBPs of any range and modulation, and to predict the output for each of these fields. We moved away from individual field calibrations to a state where continued quality assurance of SOBP field delivery is ensured by limited system-wide measurements that only require one hour per week. This manuscript reports on a protocol for generation of desired SOBPs and prediction of dose output.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗