Positron emission tomography for diagnosis of prosthetic valve endocarditis
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
N/A
Explore the source record for details and available documents.
Abstract not provided
Abstract not provided.
Abstract not provided.
A high density percutaneous chronic connector, having first and second connector structures each having an array of magnets surrounding a mounting cavity. A first electrical feedthrough array is seated in the mounting cavity of the first connector structure and a second electrical feedthrough array is seated in the mounting cavity of the second connector structure, with a feedthrough interconnect matrix positioned between a top side of the first electrical feedthrough array and a bottom side of the second electrical feedthrough array to electrically connect the first electrical feedthrough array to the second electrical feedthrough array. The two arrays of magnets are arranged to attract in a first angular position which connects the first and second connector structures together and electrically connects the percutaneously connected device to the external electronics, and to repel in a second angular position to facilitate removal of the second connector structure from the first connector structure.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
No abstract prepared.
The presence of chaos in walking is considered to provide a stable, yet adaptable means for locomotion. This study examined whether lower limb amputation and subsequent prosthetic rehabilitation resulted in a loss of complexity in amputee gait. Twenty-eight individuals with transtibial amputation participated in a 6 week, randomized cross-over design study in which they underwent a 3 week adaptation period to two separate prostheses. One prosthesis was deemed “more appropriate” and the other “less appropriate” based on matching/mismatching activity levels of the person and the prosthesis. Subjects performed a treadmill walking trial at self-selected walking speed at multiple points of the adaptation period, while kinematics of the ankle were recorded. Bilateral sagittal plane ankle motion was analyzed for underlying complexity through the pseudoperiodic surrogation analysis technique. Results revealed the presence of underlying deterministic structure in both prostheses and both the prosthetic and sound leg ankle (discriminant measure largest Lyapunov exponent). Results also revealed that the prosthetic ankle may be more likely to suffer loss of complexity than the sound ankle, and a “more appropriate” prosthesis may be better suited to help restore a healthy complexity of movement within the prosthetic ankle motion compared to a “less appropriate” prosthesis (discriminant measure sample entropy). Results from sample entropy results are less likely to be affected by the intracycle periodic dynamics as compared to the largest Lyapunov exponent. Adaptation does not seem to influence complexity in the system for experienced prosthesis users.
Recently, significant advances in robotics have led to increased use in industrial and military applications. For example, the military has used explosive ordnance disposal (EOD) robots to enable responders to remotely investigate hazardous environments. While EOD robots have saved many lives, their utility is hampered by: 1) limited ability to manipulate complex objects and mechanisms (e.g. open a car door, operate power tools or turn valves), and 2) the requirement for significant operator training using joystick-type interfaces. Most robots today have simplistic manipulators and cannot easily operate in environments designed for humans as evidenced by the recent Amazon Picking Challenge and the DARPA Robotics Challenge. Simple tasks that humans perform easily, such as picking up objects or operating a cutting tool, require customized rigs that are expensive and time-consuming to use. The specialized nature of these robots limits their utility in highly unstructured environments, for example during emergency situations where a robot may need to be rapidly re-purposed for an unanticipated situation (i.e. the Fukushima nuclear disaster). Robots are needed that can perform complex human-like tasks and are easy to use for everyday and emergency tasks. In 2005 the Defense Advanced Research Projects Agency (DARPA) initiated the Revolutionizing Prosthetics (RP) Program with the goal of creating prosthetics as capable as the human arm and a human-machine interface enabling highly intuitive operation. The Johns Hopkins University Applied Physics Laboratory (JHU/APL) created the Modular Prosthetic Limb (MPL), originally developed for amputees and paralyzed individuals as part of the RP Program, to replicate the capability of the human hand and arm to the extent technologically possible. With 26 joints and over 180 sensors, it is one of the most sophisticated and fully integrated robotic arms in the world. We have also demonstrated human-machine interface techniques that are highly intuitive requiring minimal training. While the MPL was originally designed as a prosthetic, it has also been incorporated into mobile robotic systems to project human capability. Using tele-operation, we have demonstrated the ability to perform dual-arm remote operations in complex environments. For nuclear facilities, high dexterity robots combined with tele-operation offer the potential to enhance worker safety, productivity and quality. Safety enhancements include enabling remote operation in hazardous environments, remote handling of heavy or dangerous materials, and elimination of injury due to repetitive motions. Because the MPL is designed to function like a human limb, the robot can work in environments designed for humans with limited need for specialized tools. When used for routine operations, it can also maintain a level of familiarity and confidence that effectively accomplishes reinforcement training for use in emergency situations, unlike a specialized robot that might sit unused for months or years at a time. In August 2016 we demonstrated the use of the MPL at the Portsmouth Gaseous Diffusion Plant in Piketon, Ohio. Two robotic platform technologies were demonstrated to familiarize the DOE Emergency Management's (EM) workforce on the potential benefits of this technology. Here we present the results of those efforts, highlight the lessons learned during 'EM Week,' and outline potential future developments that could further advance application of these technologies to enhance worker safety. (authors)
Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.
Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensation by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project would include fabricating some of the designed devices and seeing how they compare to the current cuffs in terms of their electrical performance, lifetime, shape, and mechanical properties.
An approximation method and system are provided for more quickly controlling a prosthetic or other device by reducing computational processing time in a muscle model that can be used to control the prosthetic. For a given muscle, the approximation method can quickly compute polynomial structures for a muscle length and for each associated moment arms, which may be used to generate a torque for a joint position of a physics model. The physics model, in turn, produces a next joint position and velocity data for driving a prosthetic. The approximation method expands the polynomial structures as long as expansion is possible and sufficiently beneficial. The computations can be performed quickly by expanding the polynomial structures in a way that constrains the muscle length polynomial to the moment arm polynomial structures, and vice versa.