Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROSTHESIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Some examples of image warping for low vision prosthesis

NASA has developed an image processor, the Programmable Remapper, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. Coordinate warpings have been developed for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype.

Juday, Richard D.↗

Prosthesis Material

FAB/CAM, a subsidiary of the Harshberger Prosthetic and Orthotic Center, Inc., approached Marshall for help in replacing the heavy, fragile plaster they used to produce master molds for prosthetics. Concurrently, Marshall and Martin Marietta were creating a commercial derivative of the foam insulation used to protect the Space Shuttle External Tank from excessive heat. FAB/CAM found the foam blanks to be lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the consumer. Martin Marietta markets the foam system, MARCORE, for the prosthesis market. The system also has commercial potential in high temperature insulation and structural applications.

Source record↗

The Dynamic Socket: A Better Prosthesis

The issues that amputees experience with current prosthetic devices are discussed and how Sandia National Laboratory is working to make them both functional and comfortable to wear.

42 ENGINEERING↗

CT imaging of inflatable penile prosthesis complications: a pictorial essay

Purpose: Inflatable penile prostheses (IPPs) are widely used in the United States, for patients with erectile dysfunction refractory to other treatments. Complications subsequent to IPP insertion include infection, hematoma, fluid leak, component (cylinder/pump/reservoir) complications, and retained previous IPP components. Radiologists are often called upon to identify and characterize these complications utilizing CT prior to intervention. Our paper aims to provide a guide to familiarize radiologists with normal IPP component imaging and review the CT findings of commonly encountered complications. Methods: In this study, we retrospectively reviewed CT reports with descriptions of IPPs from 108 patients. We collected CT images of normal IPP components as well as reevaluated the CT findings of 33 patients with an IPP complication and correlated with immediately subsequent operative report. Results: The CT appearance of appropriately positioned normal IPP components in asymptomatic patients and each complication were described and compared to previous literature. Conclusions: CT is a very useful modality to assess an IPP-related complication. It is inexpensive, fast, and immediately available in emergent situations, e.g., infection, hematoma, and component erosion. Additionally, CT is very sensitive and makes it easier to diagnose a system leak. It can identify most cylinder complications and pump malposition and can be extremely helpful to the surgeon in preoperative planning if revision is needed. After this review, the radiologist should be able to identify normal IPP components and their complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metal Artifact Reduction for Orthopedic Prosthesis in Lower Extremity CT Venography: Evaluation of Image Quality and Vessel Conspicuity

Purpose: This study evaluates the image quality of lower extremity CT venography reconstructed with orthopedic metal artifact reduction (O-MAR) in patients with unilateral or bilateral metallic prostheses in the hip or knee. Methods: This retrospective study was approved by our institutional review board, and informed consent was waived. Twenty-nine patients of lower extremity CT with 51 metallic hip or knee prostheses were reconstructed to both standard CT images and O-MAR images. The subjective image quality and vessel conspicuity for both images were evaluated by two readers using five-point scales (0–4). Vessel conspicuity scores of 3 or 4 were considered diagnostically acceptable. Image noise was measured in the air and subcutaneous fat. Results: O-MAR images showed significantly higher scores of subjective image quality (p < .001) and vessel conspicuity (p = .002) than standard CT images. Diagnostic acceptance of vessel conspicuity was not significantly different between O-MAR images and standard CT images (p = 1.000). O-MAR images showed significantly less image noise than conventional CT images (p < .001 for both air and subcutaneous fat). Conclusion: O-MAR may be an effective solution for the metal artifacts in lower extremity CT venography; however, the distance between prostheses and vessels affects the diagnostic acceptance in patients with metallic hip or knee prostheses. Level of Evidence: Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The inhibition of RANKL expression in fibroblasts attenuate CoCr particles induced aseptic prosthesis loosening via the MyD88-independent TLR signaling pathway

Periprosthetic osteolysis and aseptic loosening are mainly caused by wear particles (Ps) that are generated from friction interfaces. However, the mechanisms underlying the development of aseptic loosening remain unclear. Therefore, we aimed toclarify how the myeloid differentiation factor 88 (MyD88)-independent Toll-like receptor (TLR) signaling pathway mediates cobalt and chromium (CoCr)-Ps-induced osteolysis. We quantified the expression levels of TLRs, MyD88, RANKL, and inflammatory factors in patients experiencing aseptic loosening after primary total hip arthroplasty (THA) with metal-on-metal (MoM) bearings and hip osteoarthritis (hOA). We observed the in vitro and in vivo levels of RANKL, TLRs, and MyD88 in fibroblasts challenged with CoCr Ps by applying shMyD88 interference lentivirus vectors to block the MyD88-independent TLR pathway. The levels of TLRs, MyD88, RANKL, and inflammatory factors in the revision THA (rTHA) with MoM group were higher than those in the hOA group. Our data collectively revealed that inhibiting MyD88 expression could reduce osteoclastogenesis in vitro and CoCr-Ps-induced osteolysis in vivo. Our findings suggested that osteoclastogenesis is promoted by the CoCr-Ps-induced expression of RANKL in fibroblasts and that MyD88 is a potential target in the treatment of wear Ps-induced osteolysis.

60 APPLIED LIFE SCIENCES↗

Nonlinear dynamical system approaches towards neural prosthesis

An asynchronous discrete-state spiking neurons is a wired system of shift registers that can mimic nonlinear dynamics of an ODE-based neuron model. The control parameter of the neuron is the wiring pattern among the registers and thus they are suitable for on-chip learning. In this paper an asynchronous discrete-state spiking neuron is introduced and its typical nonlinear phenomena are demonstrated. Also, a learning algorithm for a set of neurons is presented and it is demonstrated that the algorithm enables the set of neurons to reconstruct nonlinear dynamics of another set of neurons with unknown parameter values. The learning function is validated by FPGA experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cybernetic prosthesis

Design and development of a prosthetic device fitted to an above elbow amputee is reported that derives control information from the human to modulate power to an actuator to drive the substitute limb. In turn, the artificial limb generates sensory information feedback to the human nervous system and brain. This synergetic unity feeds efferent or motor control information from the human to the machine, and the machine responds, delivering afferent or sensory information back to the man.

Mann, R. W.↗

Simulated studies of wear and friction in total hip prosthesis components with various ball sizes and surface finishes

Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.

Swikert, M. A.↗

Development of a Prosthesis for Urinary Control

Report describes development and marketing of prosthetic sphincter for urinary control. With prosthetic device, patients void bladder every 3 to 4 hours. Periodic voiding keeps bladder muscles exercised and healthy and avoids bladder infections and kidney damage.

Tenney, J. B.↗

Shape optimization of tibial prosthesis components

NASA technology and optimal design methodologies originally developed for the optimization of composite structures (engine blades) are adapted and applied to the optimization of orthopaedic knee implants. A method is developed enabling the shape tailoring of the tibial components of a total knee replacement implant for optimal interaction within the environment of the tibia. The shape of the implant components are optimized such that the stresses in the bone are favorably controlled to minimize bone degradation, to improve the mechanical integrity of the implant/interface/bone system, and to prevent failures of the implant components. A pilot tailoring system is developed and the feasibility of the concept is demonstrated and evaluated. The methodology and evolution of the existing aerospace technology from which this pilot optimization code was developed is also presented and discussed. Both symmetric and unsymmetric in-plane loading conditions are investigated. The results of the optimization process indicate a trend toward wider and tapered posts as well as thicker backing trays. Unique component geometries were obtained for the different load cases.

Saravanos, D. A.↗

Dual use of image based tracking techniques: Laser eye surgery and low vision prosthesis

With a concentration on Fourier optics pattern recognition, we have developed several methods of tracking objects in dynamic imagery to automate certain space applications such as orbital rendezvous and spacecraft capture, or planetary landing. We are developing two of these techniques for Earth applications in real-time medical image processing. The first is warping of a video image, developed to evoke shift invariance to scale and rotation in correlation pattern recognition. The technology is being applied to compensation for certain field defects in low vision humans. The second is using the optical joint Fourier transform to track the translation of unmodeled scenes. Developed as an image fixation tool to assist in calculating shape from motion, it is being applied to tracking motions of the eyeball quickly enough to keep a laser photocoagulation spot fixed on the retina, thus avoiding collateral damage.

Juday, Richard D.↗

Dual Use of Image Based Tracking Techniques: Laser Eye Surgery and Low Vision Prosthesis

With a concentration on Fourier optics pattern recognition, we have developed several methods of tracking objects in dynamic imagery to automate certain space applications such as orbital rendezvous and spacecraft capture, or planetary landing. We are developing two of these techniques for Earth applications in real-time medical image processing. The first is warping of a video image, developed to evoke shift invariance to scale and rotation in correlation pattern recognition. The technology is being applied to compensation for certain field defects in low vision humans. The second is using the optical joint Fourier transform to track the translation of unmodeled scenes. Developed as an image fixation tool to assist in calculating shape from motion, it is being applied to tracking motions of the eyeball quickly enough to keep a laser photocoagulation spot fixed on the retina, thus avoiding collateral damage.

Juday, Richard D.↗