Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flight Investigation of the Effects of Pressure-Belt Tubing Size on Measured Pressure Distributions

The pressure-belt technique is commonly used to measure pressure distributions on lifting and nonlifting surfaces where flush, through-the-surface measurements are not possible. The belts, made from strips of small-bore, flexible plastic tubing, are surface-mounted by a simple, nondestructive method. Additionally, the belts require minimal installation time, thus making them much less costly to install than flush-mounted pressure ports. Although pressure belts have been used in flight research since the early 1950s, only recently have manufacturers begun to produce thinner, more flexible tubing, and thin, strong adhesive tapes that minimize the installation-induced errors on the measurement of surface pressures. The objective of this investigation was to determine the effects of pressure-belt tubing size on the measurement of pressure distributions. For that purpose, two pressure belts were mounted on the right wing of a single-engine, propeller-driven research airplane. The outboard pressure belt served as a baseline for the measurement and the comparison of effects. Each tube had an outer diameter (OD) of 0.0625 in. The inboard belt was used to evaluate three different tube sizes: 0.0625-, 0.1250-, and 0.1875-in. OD. A computational investigation of tube size on pressure distribution also was conducted using the two-dimensional Multielement Streamtube Euler Solver (MSES) code.

Rivers, Natale A.↗

Measurement component technology. Volume 1: Cryogenic pressure measurement technology, high pressure flange seals, hydrogen embrittlement of pressure transducer material, close coupled versus remote transducer installation and temperature compensation of pressure transducers

The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.

Hayakawa, K. K.↗

An Overview of Unsteady Pressure Measurements in the Transonic Dynamics Tunnel

The NASA Langley Transonic Dynamics Tunnel has served as a unique national facility for aeroelastic testing for over forty years. A significant portion of this testing has been to measure unsteady pressures on models undergoing flutter, forced oscillations, or buffet. These tests have ranged from early launch vehicle buffet to flutter of a generic high-speed transport. This paper will highlight some of the test techniques, model design approaches, and the many unsteady pressure tests conducted in the TDT. The objectives and results of the data acquired during these tests will be summarized for each case and a brief discussion of ongoing research involving unsteady pressure measurements and new TDT capabilities will be presented.

Schuster, David M.↗

Surface pressure measurement by oxygen quenching of luminescence

Methods and compositions for measuring the pressure of an oxygen-containing gas on an aerodynamic surface, by oxygen-quenching of luminescence of molecular sensors is disclosed. Objects are coated with luminescent films containing a first sensor and at least one of two additional sensors, each of the sensors having luminescences that have different dependencies on temperature and oxygen pressure. Methods and compositions are also provided for improving pressure measurements (qualitative or quantitive) on surfaces coated with a film having one or more types of sensor.

Gouterman, Martin P.↗

Surface pressure measurement by oxygen quenching of luminescence

Methods and compositions for measuring the pressure of an oxygen-containing gas on an aerodynamic surface, by oxygen-quenching of luminescence of molecular sensors is disclosed. Objects are coated with luminescent films containing a first sensor and at least one of two additional sensors, each of the sensors having luminescences that have different dependencies on temperature and oxygen pressure. Methods and compositions are also provided for improving pressure measurements (qualitative or quantitive) on surfaces coated with a film having one or more types of sensor.

Gouterman, Martin P.↗

Evaluating the Utility of Pressure Scanners for Unsteady Pressure Measurements in Wind Tunnel Characterization of the Space Launch System

In many aerodynamic measurement applications, the ability to make time-accurate measurements with pressure scanners provides practical advantages over making the same measurements directly using flush-mounted transducers. The pneumatic distortion due to the tubing between the sensing module and surface port limits the usefulness of such measurements to averaged, steady data only. This issue has restricted the application of pressure scanners for unsteady pressure measurements in wind tunnel and flight-testing applications. The Wiener-filtered inverse system response model has been proven to be effective in reconstructing complex unsteady pressure signals acquired remotely using pressure scanners. In this work, the feasibility of using pressure scanning systems for time-resolved pressure measurements in the NASA Langley 14- by 22-Foot Subsonic Wind Tunnel was evaluated. Results demonstrated good agreement between the reference transducers and reconstructed pressure scanner measurements up to frequencies of approximately 500 Hz.

Unsteady pressure↗

Tire-pressure measuring concept

External tire-pressure measuring concept involves device that applies external load to tire wall to measure its internal pressure. Method promises to be faster than conventional tire-pressure checks, speeding up turnaround time for aircraft. Method prevents air leakage that occurs when pressure is measured through tire valve. Device is used to measure tire pressures on land vehicles.

Ashmore, L. O.↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Dynamic-pressure measurements using an electronically scanned pressure module

Frequency response was measured for different lengths and diameters of tubing between a sinusoidal pressure source and a pressure sensing module from an electronically scanned pressure measuring system. Measurements were made for straight runs of both steel and vinyl tubing. For steel tubing, measured results are compared with results calculated by using equations developed by Tijdeman and Bergh. Measurements were also made with a bend in the vinyl tubing at the module. In addition, measurements were made with two coils placed in the tubing near the middle of the run.

Chapin, W. G.↗

Time Averaged Pressure Measurement in Fundamentally Unsteady Pressure Gain Combustion Systems

Experimental results and analysis are presented on a technique for obtaining time averaged pressure in the harsh and highly unsteady environment of a pressure gain combustor. The technique utilizes a long, narrow, stand-off tube leading from the measurement point to a pressure transducer. The tube damps the fluctuations (which may result from strong shocks and/or detonations) and thermally isolates the transducer. The damping must be sufficient to ensure that net gasdynamic work exchange does not occur on the fluid in the stand-off tube, and it must be linear to insure that the time-averaged pressure at the transducer end is the same as that at the combustor end. The paper presents experimental and analytical results from two rigs which indicate that, using certain stand-off tube dimensions, these criteria are met. Physical rational for the tube dimensions (i.e., guidelines) are also presented.

detonation↗

Spatial Characteristics of F/A-18 Vertical Tail Buffet Pressures Measured in Flight

Buffeting is an aeroelastic phenomenon which plagues high performance aircraft, especially those with twin vertical tails, at high angles of attack. Previous wind-tunnel and flight tests were conducted to characterize the buffet loads on the vertical tails by measuring surface pressures, bending moments, and accelerations. Following these tests, buffeting estimates were computed using the measured buffet pressures and compared to the measured responses. The estimates did not match the measured data because the assumed spatial correlation of the buffet pressures was not correct. A better understanding of the partial (spatial) correlation of the differential buffet pressures on the tail was necessary to improve the buffeting estimates. Several wind-tunnel investigations were conducted for this purpose. When combined and compared, the results of these tests show that the partial correlation depends on and scales with flight conditions. One of the remaining questions is whether the windtunnel data is consistent with flight data. Presented herein, cross-spectra and coherence functions calculated from pressures that were measured on the high alpha research vehicle (HARV) indicate that the partial correlation of the buffet pressures in flight agrees with the partial correlation observed in the wind tunnel.

Moses, Robert W.↗

Automatic blood pressure measuring system (M092)

The Blood Pressure Measuring System is described. It measures blood pressure by the noninvasive Korotkoff sound technique on a continual basis as physical stress is imposed during experiment M092, Lower Body Negative Pressure, and experiment M171, Metabolic Activity.

Nolte, R. W.↗

Transducer Installation Effects on Pressure Measurements in PGC Devices

Pressure gain devices such as rotating detonation engines present an extremely harsh environment, generally precluding the use of any intrusive probe measurement. The most widely used diagnostic is the measurement of high frequency pressure which can be used to determine the pressure amplitude, number of waves and their direction and the wave structure. The preferred approach for making pressure measurements is to install the sensing element flush with the combustion chamber wall, but is almost always inhibited by the extremely high heat fluxes that can damage the sensor. Alternately, recessed cavity or infinite probe installation is seldom used for high frequency pressure measurements. While amplitude attenuation and phase distortion of the pressure signal can be introduced by these installation types, its characterization in the presence of high amplitude steep fronted pressure waves encountered in PGC devices has not been previously performed. In the current work a highly modular calibration test-bed is designed to enable characterization of pressure transducers based on their installation in the presence of steep fronted high amplitude pressure waves. Two transducer types, piezoelectric PCB® 113B26 and water-cooled piezoresistive Kulite®WCT-312M were used and installed in the flush, recessed cavity and infinite tube probe configuration. The recessed cavity probe showed 5-26% amplitude attenuation and almost negligible time lag compared to the flush transducer, the infinite tube pressure (ITP) transducer showed a significantly higher delay and as much as 50% reduction in measured pressure amplitude. Secondary wave features from reflections within the test article, that were captured by the flush and recessed cavity transducer were damped by the infinite probe measurement.

20 FOSSIL-FUELED POWER PLANTS↗