Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy storage systems for electrical microgrids with pulsed power loads

Pulsed power loads (PPLs) are highly non-linear and can cause significant stability and power quality issues in an electrical microgrid. According to the present invention, many of these issues can be mitigated by an Energy Storage System (ESS) that offsets the PPL. The ESS can maintain a constant bus voltage and decouple the generation sources from the PPL. For example, the ESS specifications can be obtained with an ideal, band-limited hybrid battery and flywheel system.

Weaver, Wayne W.↗

Assessing and Reducing Plug and Process Loads in Retail Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retail Buildings: Assessing and Reducing Plug and Process Loads in Retail Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A-Cation-Dependent Structure–Optical Property Relationships of Halide Perovskite Heterostructures with Complex Interfaces

Halide perovskite heterostructures offer promising interfacial interactions for energy conversion, yet challenges in synthesizing structurally well-defined systems limit detailed investigations into structure–property relationships. In this article, we report the synthesis of compositionally controlled 3D/3D and 3D/2D halide perovskite heterostructures using evaporation crystallization-polymer pen lithography (EC-PPL) and a single-particle analysis of their properties. By systematically varying A-site cation combinations and crystal dimensions, we show that heterointerfaces induce local lattice distortions that modulate vibrational dynamics and electron-phonon coupling. These interfacial effects result in significantly extended carrier lifetimes compared to compositionally similar pure phases. Raman spectroscopy, temperature-dependent photoluminescence, and power-dependent emission analysis reveal that localized structural modulations at the interface govern exciton-phonon interactions. These effects are magnified in smaller crystals due to increased interfacial contributions. Our findings highlight the critical role of interface-driven lattice control in tuning the optoelectronic properties of halide perovskites and provide design principles for engineering heterostructures in next-generation optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigating Catastrophic Forgetting in Deep Learning in a Streaming Setting Using Historical Summary

Recent advancements in scientific equipment and the adaptation of electronics and the Internet of Things (IoT) in our everyday lives resulted in large and complex data production at a high rate. Making meaningful and timely knowledge discovery at a modest cost from this big data is difficult for computing power and storage limitations. Training deep learning models incrementally in a streaming setting can help us with overcoming these limitations. However, in a well-known phenomenon named catastrophic forgetting, incrementally trained models increasingly perform poorly on the past data. To mitigate catastrophic forgetting in training in a streaming setting, we propose constructing a historical summary over time and use the summary with newly arrived data during incremental training. We propose various data summarization techniques such as random sampling, micro clustering, coreset computation, and Auto Encoders to counteract catastrophic forgetting. We built a pipeline for incremental training with a historical summary for training deep learning models for streaming data. We demonstrate the effectiveness of historical summary in mitigating catastrophic forgetting using three case studies involving three different deep learning applications: an Artificial Neural Network (ANN) for classification task on MNIST dataset, a language model (RNN-LM) on the WikiText2 dataset, and a Convolutional Neural Network (CNN), ResNet50 to classify the ImageNet dataset. Through the training of the models, we observe that catastrophic forgetting is evident in ANN and CNN but not in an RNN. For the first task, our method recovers up to 47.9% lost accuracy due to catastrophic forgetting. For the third task, the historical summary recovers classification accuracy by up to 25%. For the second task, though there is not proof of catastrophic forgetting, the training performance (PPL) improves by up to 26% with historical summary.

Dash, Sajal↗

Full Scale Field Trial of the Low Temperature Mercury Capture Process

CONSOL Energy Inc., with partial funding from the Department of Energy (DOE) National Energy Technology Laboratory, designed a full-scale installation for a field trial of the Low-Temperature Mercury Control (LTMC) process, which has the ability to reduce mercury emissions from coal-fired power plants by over 90 percent, by cooling flue gas temperatures to approximately 230°F and absorbing the mercury on the native carbon in the fly ash, as was recently demonstrated by CONSOL R&D on a slip-stream pilot plant at the Allegheny Energy Mitchell Station with partial support by DOE. LTMC has the potential to remove over 90 percent of the flue gas mercury at a cost at least an order of magnitude lower (on a $/lb mercury removed basis) than activated carbon injection. The technology is suitable for retrofitting to existing and new plants, and, although it is best suited to bituminous coal-fired plants, it may have some applicability to the full range of coal types. Installation plans were altered and moved from the original project host site, PPL Martins Creek plant, to a second host site at Allegheny Energy's R. Paul Smith plant, before installation actually occurred at the Jamestown (New York) Board of Public Utilities (BPU) Samuel A. Carlson (Carlson) Municipal Generating Station Unit 12, where the LTMC system was operated on a limited basis. At Carlson, over 60% mercury removal was demonstrated by cooling the flue gas to 220-230°F at the ESP inlet via humidification. The host unit ESP operation was unaffected by the humidification and performed satisfactorily at low temperature conditions.

20 FOSSIL-FUELED POWER PLANTS↗

HFIR Dissolution Nuclear Criticality Analysis Information

H-Canyon Nuclear and Criticality Safety Engineering has completed development of the documentation necessary to complete the September 30, 2014, H-Canyon PBI milestone that states: Complete the analytical work to develop proposed HFIR Criticality Safety Limits associated with receipt and dissolving of HFIR material. Attached to this memorandum are the following: (1) Attachment 1- HFIR Dissolution Nuclear Criticality Analysis; (2) Attachment 2 - SCALE 5/KENO VI sample input As documented in Attachment 1, the safety of HFIR dissolution in H-Canyon has been evaluated. Due to the composition and geometry of the HFIR elements and the chemistry of the dissolution process, there are no credible criticality events associated with HFIR dissolution, with the exception of potential Pu polymerization. There are no mass, concentration, or soluble poison CSLs required for HFIR dissolution in H-Canyon. If SRNL, in the development of the HFIR flow sheet, determines that Pu polymerization is a credible event, a minimum nitric acid PPL and controls will be developed. However, there is no analysis or CSLs needed for this event. The boron in the borated stainless steel posts is not required, and, therefore, blackness testing is not required for criticality safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

Practical Probabilistic Programming

Recent advances in probabilistic programming languages (PPLs) have provided the capability for exact inference: computing a closed-form probability distribution for a given probabilistic program. In particular, the new language Roulette uses a language oriented programming (LOP) approach, wherein analysts build new programming languages on top of a set of primitives provided by Roulette, which then translates these structures into a weighted model counting problem which can be solved by automated reasoning tools. However, because Roulette provides few convenience features, developing these new languages is challenging even for expert users. We developed a standard library of common probability functions for Roulette with the goal of improved usability. This included approximation of continuous probability density functions using discrete probability mass functions. We demonstrated this approach by modeling a cosmic ray striking a RAM controller. We found that Roulette provides a powerful interface for highly expressive probabilistic programs to be generated. In collaboration with the NNSA Advanced Simulation and Computing program, which resulted in development of a tool called Circulette, we were able to model complex circuits expressed in Verilog using probabilistic programs with an expressivity not previously possible. Our research question that motivated the development of a Roulette standard library was to determine whether non-experts could use a PPL to model relevant problems regarding radiation effects on microelectronics. This standard library improved the expressivity of Roulette by implementing common probability density functions, mathematical operators on distributions, and support for empirical distributions. While Roulette is a powerful modeling language, the untyped, LOP approach makes error messages difficult to understand and requires expert aid. We recommend further research on Roulette, especially with its error messages, to enable improved usability. At the same time, this project demonstrated that for users familiar with Roulette and the LOP approach, Roulette provides powerful new capabilities that can be integrated with other Sandia modeling capabilities.

97 MATHEMATICS AND COMPUTING↗

ESI-FTICR-MS Analysis of Organic Matter during Incubations with Nitrogen Addition, Teller Road Site, Seward Peninsula, Alaska

This dataset contains the results of the molecular characterization of water-extractable organic matter collected during soil microcosm incubations of tundra soil. The microcosms contained soil collected in April 2017 from the NGEE Arctic Teller Road Site at mile marker 27 (TL_MM27) near Intensive Site 9 (“Toeslope”) and Intensive Site 5 (“Plateau”). The incubations were conducted under an atmosphere of N2 at 8°C for 55 days, with or without addition of ammonium chloride (NH4Cl). Soils were extracted with deionized water and extracted using Bond Elut PPL cartridges prior to analysis. Molecular characterization was performed using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI- FTICR-MS). Two data files are provided with this dataset. The first is the summary, by soil type and treatment, of the mass spectrometry results for formulas (as a % of the total) containing C, H, and O only, and with N, S, and other elements. These formulas were then grouped into nine biochemical classes of compounds based on O:C and H:C ratios. The second file provides soil sample characteristics and the processed high-resolution mass spectrometry results by soil type and treatment.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 10-year research effort (2012-2022) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Subtask 2.18 - Advancing CO 2 Capture Technology: Partnership for CO 2 Capture (PCO 2 C) Phase III

Industries and utilities continue to investigate ways to decrease their carbon footprint. Carbon capture and storage (CCS) can enable existing power generation facilities to meet the current national CO 2 reduction goals. The Partnership for CO2 Capture Phase III focused on several important research areas in an effort to find ways to decrease the cost of capture across both precombustion and postcombustion platforms. Two flue gas pretreatment technologies for postcombustion capture, an SO 2 reduction scrubbing technology from Cansolv Technologies Inc. and the Tri-Mer filtration technology that combines particulate, NOx, and SO 2 control, were evaluated on the Energy & Environmental Research Center’s (EERC’s) pilot-scale test system. Pretreating the flue gas should enable more efficient, and therefore less expensive, CO 2 capture. Both technologies were found to be effective in pretreating flue gas prior to CO 2 capture. Two new postcombustion capture solvents were tested, one from the Korea Carbon Capture and Sequestration R&D Center (KCRC) and one from CO 2 Solutions Incorporated. Both of these solvents showed the ability to capture CO 2 while requiring less regeneration energy, which would reduce the cost of capture. Hydrogen separation membranes from Commonwealth Scientific and Industrial Research Organisation were evaluated through precombustion testing. They are composed of vanadium alloy, which is less expensive than the palladium alloys that are typically used. Their performance was comparable to that of other membranes that have been tested at the EERC. Aspen Plus® software was used to model the KCRC and CO 2 Solutions solvents and found that they would result in significantly improved overall plant performance. The modeling effort also showed that the parasitic steam load at partial capture of 45% is less than half that of 90% overall capture, indicating savings that could be accrued if 90% capture is not required. Modeling of three regional power plants using the Carnegie Mellon Integrated Environmental Control Model showed that, among other things, the use of a bypass during partial capture may minimize the size of the capture tower(s) and result in a slight reduction in the revenue required to operate the capture facility. The results reinforced that a one-size-fits-all approach cannot be taken to adding capture to a power plant. Laboratory testing indicated that Fourier transform infrared spectroscopy could be used to continuously sample stack emissions at CO 2 capture facilities to detect and quantify any residual amine or its degradation products, particularly nitrosamines. The information gathered during Phase III is important for utility stakeholders as they determine how to reduce their CO 2 emissions in a carbon-constrained world. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the North Dakota Industrial Commission, PPL Montana, Nebraska Public Power District, Tri-Mer Corporation, Montana–Dakota Utilities Co., Basin Electric Power Cooperative, KCRC/Korean Institute of Energy Research, Cansolv Technologies, and CO 2 Solutions, Inc.

01 COAL, LIGNITE, AND PEAT↗

Navigating Cybersecurity Implications of Smart Outlets

Plug and process loads (PPLs) consume approximately one third of U.S. buildings' energy budget. As other equipment becomes more efficient, and plug-in devices diversify in the market, the percentage of PPL energy consumption is forecasted to grow. To help combat this growth, new wireless metering and control technologies (also known as 'smart outlets') are helping building owners to collect plug load data, understand usage patterns, and implement controls. Adoption of these new connected technologies motivates serious cybersecurity consideration. Because these new technologies are developing at such a rapid pace, the aim of this paper is to inform thinking about cybersecurity issues and the risks that they impose. Through this lens, we explore the pros and cons of plug load controllers, provide a framework for assessing cybersecurity of connected devices such as plug load controllers, and offer an example of how commercial building owners could use this framework to minimize their cybersecurity risks when adopting smart products. In providing this framework, this paper aims to remove some barriers to implementation of these energy efficient technologies in the built environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RECS student sequestration program

The 2007 Research Experiment in Carbon Sequestration (RECS) met at the Montana State University (MSU) and a variety of field sites over the 10-day period of July 29 - Aug 10. This year's group consisted of 17 students from graduate and doctoral programs in the United States and Canada, as well as early career professionals in fields related to carbon mitigation. Appropriately, because greenhouse gas reduction and storage is a global problem, the group included seven international students, from France, Iran, Paraguay, Turkey, Russia and India. Classroom talks featured experts from academia, government, national laboratories, and the private sector, who discussed carbon capture and storage technologies and related policy issues. Then, students traveled to Colstrip, Montana to visit PPL Montana's coal-fired power plant and view the local geology along the Montana/Wyoming border. Finally, students spent several days in the hands-on work at ZERT, using carbon dioxide detection and monitoring equipment. 1 photo.

20 FOSSIL-FUELED POWER PLANTS↗

Comparing materials used in mist eliminators

Wet flue gas desulfurization (FGD) systems, or wet scrubbers, are notoriously capital - and maintenance-intensive. Mist eliminators are an integral part of most wet FGD systems. These are available in a variety of materials - polypropylene, fiberglass reinforced polymer (FRP), polysulfone and stainless steel. The article discusses the material properties, performance attributes and relative cost differences associated with each of these four materials. It describes the common problems with mist eliminators - fouling and corrosion. These can be minimised by routine cleaning and use of chemical additives to prevent deposition. An analysis was carried out to compare the four materials at APS Cholla power plant. As a result the facility is retrofitting its remaining wet scrubber towers in Unit 2 with mist eliminators constructed from polysulfone as each of the current ones of the existing polypropylene needs replacing. Polysulfone is cheaper to clean and components require replacing less frequently than polypropylene. Switching from stainless steel to polypropylene has proved advantageous on 22 wet scrubbers operated by PPL Montana. 5 figs. 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Qualified display system architecture - 246

There is a need in the nuclear industry for a Qualified Display System (QDS) architecture as described in this paper. The function of the QDS is to process and display Regulatory Guide 1.97 post accident monitoring parameters. The QDS is implemented on the Lockheed Martin Field-Programmable Gate Array (FPGA) based Nuclear Protection and Control (NuPAC) digital platform, coupled with a Qualified Display Controller (QDC) and a Safety Display Unit (SDU). The QDS is designed to meet the requirements of IEEE 603-1991 (endorsed by Regulatory Guide 1.153, Rev. 1), IEEE 497-2002 (endorsed by Regulatory Guide 1.97, Rev. 4), and IEEE 7-4.3.2- 2003 (endorsed by Regulatory Guide 1.152, Rev. 3). The QDS is designed with flexibility such that it can be implemented in an advanced reactor design, Small Modular Reactor (SMR) with any cooling medium, or digital upgrade project for an operating nuclear plant. The QDS has four independent and redundant divisions. Each division has five layers in the architecture: Process variable input signals; Process Protection Logic (PPL); Algorithm Logic (AL), Interface Panel (IP); and Safety Display Unit (SDU). The QDS meets the following design criteria: redundancy, independence, predictability and repeatability, and diversity capability. The QDS architecture also meets the simplicity design principle. The QDS architecture design provides flexibility in the implementation in a plant. The QDS can be implemented in the design of a new advanced plant or as a digital upgrade in an operating plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗