Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER CAPTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary Technical Environmental Health and Safety (EH&S) Assessment – Pilot Test of Novel Electrochemical Membrane System for Carbon Dioxide Capture and Power Generation

A preliminary Environmental Health and Safety (EH&S) assessment of the Electrochemical Membrane (ECM)-based CO2 capture system was conducted. This topical report presents the results of the EH&S assessment. The study was based on the carbon capture system size suitable for a reference 550 MW Pulverized Coal (PC) power plant. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name SureSource (previously Direct FuelCell®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO2 from the host plant flue gas. The CEPACS system process description and review of process, ancillary and incidental gaseous (or air) and liquid (or water) emissions (discharge) as well as the solid waste are included in this report. The report also discusses the related handling requirements and properties of process discharge streams/waste, and the relevant regulatory requirements.

20 FOSSIL-FUELED POWER PLANTS↗

Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

FuelCell Energy, Inc. (FCE), in collaboration with AECOM Corporation (formerly URS Corporation) and Pacific Northwest National Laboratory, has been developing a novel Combined Electric Power and Carbon-dioxide Separation (CEPACS) system. The CEPACS system is based on electrochemical membrane (ECM) technology derived from FCE’s carbonate fuel cell products featuring internal (methane steam) reforming and carrying the trade name of Direct FuelCell®. The unique chemistry of carbonate fuel cells offers an innovative approach for separation of CO 2 from existing fossil-fuel power plant exhaust streams (flue gases). The ECM-based CEPACS system has the potential to become a transformational CO 2 -separation technology by working as two devices in one: it separates the CO 2 from the exhaust of other plants such as an existing coal-fired plant and simultaneously produces clean electric power at high efficiency using a supplementary fuel. The development effort was carried out under the U.S. Department of Energy (DOE) cooperative agreement DE-FE0007634. The overall objective of this project was to successfully demonstrate the ability of FCE’s ECM-based CEPACS system technology to separate ≥90% of the CO 2 from a simulated Pulverized Coal (PC) power plant flue gas stream and to compress the captured CO2 to a state that can be easily transported for sequestration or beneficial use. In addition, a key objective was to show, through the technical and economic feasibility study and bench scale testing, that the ECM-based CEPACS system is an economical alternative for CO 2 capture in PC power plants, and that it meets DOE’s objective related to the incremental cost of electricity (COE) for post-combustion CO 2 capture (no more than 35% increase in COE). The project was performed in three budget periods (BP). The specific objective for BP1 was to complete the Preliminary Technical and Economic Feasibility Study. The T&EF study was based on the carbon capture system size suitable for a reference 550 MW PC power plant. The specific objectives for BP2 were to perform (flue gas) contaminant effect evaluation tests, small area membrane tests using clean simulated flue gas, design a flue gas pretreatment system for processing of the gas feed to ECM, update the Technical & Economic Feasibility Study (T&EFS) incorporating results of contaminant effect tests and small area membrane tests, and to prepare a test facility for bench scale testing. The specific objectives for BP3 were to perform bench scale testing (parametric and long-duration testing) of a 11.7 m 2 ECM-based CO 2 capture, purification and compression system, and update (as final) the Technical and Economic Feasibility Study. In addition, an Environmental Health and Safety evaluation (assessment) of the ECM technology was included. This final technical report presents the progress made under the project.

20 FOSSIL-FUELED POWER PLANTS↗

Updated (BP3) Technical and Economic Feasibility Study - Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

This topical report summarizes the results of an updated Technical & Economic Feasibility Study (T&EFS) which was conducted in Budget Period 3 of the project to evaluate the performance and cost of the Electrochemical Membrane (ECM)-based CO2 capture system. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name Direct FuelCell® (DFC®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO2 from the flue gas. In this study, an ECM-based CEPACS plant was designed to capture and compress >90% of the CO2 (for sequestration or beneficial use) from the flue gas of a reference 550 MW (nominal, net AC) Pulverized Coal (PC) Rankine Cycle (Subcritical steam) power plant. ECM performance was updated based on bench scale ECM stack test results. The system process simulations were performed to generate the CEPACS plant performance estimates. The performance assessment included estimation of the parasitic power consumption for CO2 capture and compression, and the efficiency impact on the PC plant. While the ECM-based CEPACS system for the 550 MW PC plant captures 90% of CO2 from the flue gas, it generates additional (net AC) power after compensating for the auxiliary power requirements of CO2 capture and compression. An equipment list, ECM stacks packaging design, and CEPACS plant layout were developed to facilitate the economic analysis. Vendor quotes were also solicited. The economic feasibility study included estimation of CEPACS plant capital cost, cost of electricity (COE) analyses and estimation of cost per ton of CO2 captured. The incremental COE for the ECM-based CO2 capture is expected to meet U.S. DOE’s target of 35%. This study has indicated that CEPACS systems offer significant benefits with respect to cost, performance, water consumption and emissions to environment. The realization of these benefits will provide a single solution to carbon dioxide capture in addition to meeting the increasing demand for electricity.

20 FOSSIL-FUELED POWER PLANTS↗

Updated (BP3) Technical and Economic Feasibility Study - Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

This topical report summarizes the results of an updated Technical & Economic Feasibility Study (T&EFS) which was conducted in Budget Period 3 of the project to evaluate the performance and cost of the Electrochemical Membrane (ECM)-based CO 2 capture system. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name Direct FuelCell® (DFC®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO 2 from the flue gas. In this study, an ECM-based CEPACS plant was designed to capture and compress >90% of the CO 2 (for sequestration or beneficial use) from the flue gas of a reference 550 MW (nominal, net AC) Pulverized Coal (PC) Rankine Cycle (Subcritical steam) power plant. ECM performance was updated based on bench scale ECM stack test results. The system process simulations were performed to generate the CEPACS plant performance estimates. The performance assessment included estimation of the parasitic power consumption for CO 2 capture and compression, and the efficiency impact on the PC plant. While the ECM-based CEPACS system for the 550 MW PC plant captures 90% of CO 2 from the flue gas, it generates additional (net AC) power after compensating for the auxiliary power requirements of CO 2 capture and compression. An equipment list, ECM stacks packaging design, and CEPACS plant layout were developed to facilitate the economic analysis. Vendor quotes were also solicited. The economic feasibility study included estimation of CEPACS plant capital cost, cost of electricity (COE) analyses and estimation of cost per ton of CO 2 captured. The incremental COE for the ECM-based CO 2 capture is expected to meet U.S. DOE’s target of 35%. This study has indicated that CEPACS systems offer significant benefits with respect to cost, performance, water consumption and emissions to environment. The realization of these benefits will provide a single solution to carbon dioxide capture in addition to meeting the increasing demand for electricity.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot Test of Novel Electrochemical Membrane System for Carbon Dioxide Capture and Power Generation (Final Report)

The goal of this U.S. Department of Energy (DOE) sponsored project under cooperative agreement DE-FE0026580 is to verify that Fuel Cell Energy’s (FCE) Electrochemical Membrane (ECM)-based Combined Electric Power and Carbon Separation (CEPACS) system can achieve at least 90% carbon dioxide (CO 2 ) capture rate from Pulverized Coal (PC) power plant flue gas with 95% CO2 purity at a cost of electricity (COE) 30% less than baseline CO 2 capture approaches. To progress towards the DOE’s ultimate carbon capture program goals, the specific objectives of Budget Period 1 (BP1) of the project are to perform a preliminary Techno-Economic Analysis (TEA) and Environmental, Health and Safety (EH&S) Risk Assessment study, as well as to complete the detailed design of a pilot-scale ECM-based CEPACS system. This final technical report summarizes the results of the preliminary TEA and EH&S assessment of an ECM-based CEPACS system designed to capture and compress >90% of CO 2 from the flue gas of a reference 550 MW (net AC) Pulverized Coal (PC) Supercritical Steam Cycle Plant. Also included in this report is a summary of the detailed design for a pilot 3 MWe (flue gas equivalent) ECM-based CEPACS system designed to capture ≥90% of CO 2 from a PC plant flue gas slipstream and produce high-purity (≥95%) CO 2 . The pilot system is designed to process a slipstream of flue gas from the Unit 5 coal-fired boiler at the James M. Barry Electric Generating Station (Plant Barry). Plant Barry is located in Bucks, Alabama and is owned and operated by Alabama Power Company, a subsidiary of Southern Company. The TEA shows that the ECM-based CO 2 capture technology has an economic advantage over the existing CO 2 capture technology and meets the DOE’s cost target and performance goals for post-combustion CO 2 capture. The EH&S study includes the identification and quantification of the emissions from the CEPACS system. Properties of the waste including reactivity, flammability, corrosivity and toxicological effects are discussed along with the methods for minimization/elimination where applicable. The study shows that no major EH&S issues are expected to hinder commercialization of the ECM technology for large scale carbon capture applications. The detailed Front End Engineering Design (FEED) package for FCE’s MW-class ECM-based CO 2 capture pilot system is complete. It is designed in accordance with the project objectives and is now at a point where equipment/component procurement, skid final design and fabrication, and site preparation activities can begin in a follow-on project phase.

20 FOSSIL-FUELED POWER PLANTS↗

Real-Time Sea State Estimation for Wave Energy Converter Control via Machine Learning

Wave energy converters (WECs) harness the untapped power of ocean waves to generate renewable energy, offering a promising solution to sustainable energy. An optimal WEC control strategy is essential to maximize power capture that dynamically adjusts system parameters in response to rapidly changing sea states. This study presents a novel control approach that leverages neural networks to estimate sea states from onboard WEC measurements such as position, velocity, and force. Using a point absorber WEC device as a test platform, our proposed approach estimates sea states in real-time and subsequently adjusts PID controller gains to maximize energy extraction. Simulation results across diverse sea conditions demonstrate that our strategy eliminates the need for external wave monitoring equipment while maintaining power capture efficiency. The results show that our neural network-based control technique can improve power capture by 25.6% while significantly reducing system complexity. This approach offers a practical alternative for WEC deployments where direct wave measurements are either infeasible or cost prohibitive.

PIDcontrol↗

Dynamic modeling to minimize energy use for CO{sub 2} capture in power plants by aqueous monoethanolamine

A dynamic rate-based model was developed for stripping in CO{sub 2} capture from coal-fired power plants with 30 wt% monoethanolamine (MEA). The model, created in a flow sheet of Aspen Custom Modeler, was based on the film theory for liquid and vapor phases. It takes into account the impact of equilibrium reactions on the mass transfer, thermodynamic nonidealities, and the hydraulics of the structured packing. With this model, steady state analyses were. carried out for the stripper to understand the effect of the leah loading and the height of the packing on total equivalent work and find optimum operating conditions that minimize power plant lost work. Two dynamic strategies with control configurations are proposed to run the stripper in a flexible operation during the period of electricity peak load and prices. Open loop responses demonstrated some differences in dynamic behavior and steady state values for proposed dynamic strategies. One of the approaches increased the CO{sub 2} removal by 1% at the reduced steam rate and provided faster response of the stripper to a step change in the reboiler heat rate.

01 COAL, LIGNITE, AND PEAT↗

NUCLEAR POWERED CO2 CAPTURE FROM THE ATMOSPHERE

A process for capturing CO{sub 2} from the atmosphere was recently proposed. This process uses a closed cycle of sodium and calcium hydroxide, carbonate, and oxide transformations to capture dilute CO{sub 2} from the atmosphere and to generate a concentrated stream of CO{sub 2} that is amenable to sequestration or subsequent chemical transformations. In one of the process steps, a fossil-fueled lime kiln is needed, which reduces the net CO{sub 2} capture of the process. It is proposed to replace the fossil-fueled lime kiln with a modified kiln heated by a high-temperature nuclear reactor. This will have the effect of eliminating the use of fossil fuels for the process and increasing the net CO{sub 2} capture. Although the process is suitable to support sequestration, the use of a nuclear power source for the process provides additional capabilities, and the captured CO{sub 2} may be combined with nuclear-produced hydrogen to produce liquid fuels via Fischer-Tropsch synthesis or other technologies. Conceivably, such plants would be carbon-neutral, and could be placed virtually anywhere without being tied to fossil fuel sources or geological sequestration sites.

01 COAL, LIGNITE, AND PEAT↗

Tapping municipal water supply systems for low-impact hydropower growth

Conduit hydropower is a form of low-impact hydropower that uses existing water infrastructure, such as canals or pipelines, to capture what would otherwise be wasted energy. Agricultural conduits convey irrigation water across vast stretches of the U.S., primarily in the west, and are well-suited for hydrokinetic power capture within the flow stream or for hydro potential power capture where excess pressure exists. Drop structures within irrigation canals are suitable candidates for this type of hydropower development and have been retrofitted across a large number of sites over the past few decades.

13 HYDRO ENERGY↗

Sodium-based dry regenerable sorbent for carbon dioxide capture from power plant flue gas

Dry regenerable sorbent technology is one of the emerging technologies as a cost-effective and energy-efficient technology for CO{sub 2} capture from flue gas. Six sodium-based dry regenerable sorbents were prepared by spray-drying techniques. Their physical properties and reactivities were tested to evaluate their applicability to a fluidized-bed or fast transport-bed CO{sub 2} capture process. Each sorbents contained 20-50 wt% of Na{sub 2}CO{sub 3} or NaHCO{sub 3}. All sorbents except for Sorb NX30 were insufficient with either attrition resistance or reactivity, or both properties. Sorb NX30 sorbent satisfied most of the physical requirements for a commercial fluidized-bed reactor process along with good chemical reactivity. Sorb NX30 sorbent had a spherical shape, an average size of 89 {mu}m, a size distribution of 38-250 {mu}m, and a bulk density of approximately 0.87 g/mL. The attrition index (AI) of Sorb NX30 reached below 5% compared to about 20% for commercial fluidized catalytic cracking (FCC) catalysts. CO{sub 2} sorption capacity of Sorb NX30 was approximately 10 wt% (>80% sorbent utilization) in the simulated flue gas condition compared with 6 of 30 wt% MEA solution (33% sorbent utilization). All sorbents showed almost-complete regeneration at temperatures less than 120{sup o}C.

01 COAL, LIGNITE, AND PEAT↗

Advanced Controls for the Multi-pod Centipod WEC device

Dehlsen Associates, LLC (DA) has developed a Wave Energy Converter (WEC), Centipod, which is a multiple point absorber, extracting wave energy primarily in the heave direction through a plurality of point absorber floats sharing a common stable reference structure. The objective of this project was to develop advanced control algorithms that will be used to reduce Levelized Cost of Energy (LCOE). This project investigated the use of Model Predictive Control (MPC) to improve the power capture of the WEC. The MPC controller developed in this work is a state-space, “look ahead” controller approach using knowledge of past and current states to predict future states to take action with the PTO to maximize power capture while still respecting system constraints. In order to maximize power, which is the product of force and velocity, the controller must aim to create phase alignment between excitation force and velocity. This project showed a 161% improvement in the Annual Energy Production (AEP) for the Centipod WEC when utilizing MPC, compared to a baseline, fixed passive damping control strategy. This improvement in AEP was shown to provide a substantial benefit to the WEC’s overall Cost of Energy, reducing LCOE by 50% from baseline. The results of this work proved great potential for the adoption of Model Predictive Controls in Wave Energy Converters.

16 TIDAL AND WAVE POWER↗

Balancing Power Absorption and Fatigue Loads in Irregular Waves for an Oscillating Surge Wave Energy Converter

The aim of this paper is to describe how to control the power-to-load ratio of a novel wave energy converter (WEC) in irregular waves. The novel WEC that is being developed at the National Renewable Energy Laboratory combines an oscillating surge wave energy converter (OSWEC) with control surfaces as part of the structure; however, this work only considers one fixed geometric configuration. This work extends the optimal control problem so as to not solely maximize the time-averaged power, but to also consider the power-take-off (PTO) torque and foundation forces that arise because of WEC motion. The objective function of the controller will include competing terms that force the controller to balance power capture with structural loading. Separate penalty weights were placed on the surge-foundation force and PTO torque magnitude, which allows the controller to be tuned to emphasize either power absorption or load shedding. Results of this study found that, with proper selection of penalty weights, gains in time-averaged power would exceed the gains in structural loading while minimizing the reactive power requirement.

16 TIDAL AND WAVE POWER↗

Progress Towards Commercialization of Electrochemical Membrane Technology for CO2 Capture and Power Generation

To address the concerns about climate change resulting from emission of CO2 by coal-fueled power plants, FuelCell Energy, Inc. has developed Combined Electric Power and Carbon-dioxide Separation (CEPACS) system concept, as a novel solution for greenhouse gas emission reduction. The CEPACS system utilizes Electrochemical Membrane (ECM) technology derived from the Company’s well established Direct FuelCell® products. The system concept works as two devices in one: it separates the CO2 from the exhaust of other plants and simultaneously, using a supplementary fuel, produces electric power at high efficiency. FCE is currently evaluating the use of ECM to cost effectively separate CO2 from the flue gas of coal fired power plants under a U.S. Department of Energy contract. The overarching objective of the project is to verify that the ECM can achieve at least 90% CO2 capture from flue gas of a PC plant with no more than 35% increase in the cost of electricity. The specific objectives and related activities presently ongoing for the project include: 1) conduct bench scale tests of ECM and 2) evaluate the effects of impurities present in the coal plant flue gas by laboratory scale performance tests of the membrane.

carbon↗

Investigating the Impact of Power-Take-Off System Parameters and Control Law on a Rotational Wave Energy Converter’s Peak-to-Average Power Ratio Reduction

Due to the irregular nature of real waves, the power captured in a wave energy converter (WEC) system is highly variable. This is an important barrier to the effective use of WECs. To address this challenge, this study focuses on a rotational WEC power-take-off system in which high-speed and high-efficiency generators along with a torque/power smoothing inertia element can be effectively utilized. In the first phase of this study, the U.S. Department of Energy’s reference model 3 (WEC-Sim RM3; two-body point absorber), along with a slider-crank WEC, were integrated for linear to rotational conversion. Relative motion between the float and spar in RM3 was the driving force for this slider-crank WEC, which is connected to a motor/generator set through a gearbox. RM3 geometry was scaled down by 25 times to work within the limits of the physical motor/generator set used in the experimentation. Once the integration in a hardware-in-the-loop simulation environment was successfully completed, data on the peak-to-average power ratio was collected for various wave conditions including regular and irregular waves. The control algorithm designed to keep the system in resonance with waves was able to maintain relatively high speed depending on the specific gear ratio and wave period. Initial results with hardware-in-the-loop simulations reveal that gear ratio and crank radius have a strong impact on the peak-to-average power ratio. In addition, it was found that output power from the generator was maximized at a larger gear ratio, as the crank radius was increased.

50 EE - Wind and Water Power Program - Water (EE-4↗

Power increases using wind direction spatial filtering for wind farm control: Evaluation using FLORIS, modified for dynamic settings

As wind energy plays a growing role in the energy sector, new methods for controlling wind turbines and wind farms to maximize performance are garnering industry interest. A developing body of research treats the entire wind farm as a control system, with individual turbines acting as agents in a network, allowing farm-level objectives to be considered. Two promising developments in this research are wake steering control, which seeks to increase the power generated at a wind farm by directing the wakes of upstream turbines away from downstream ones, and communication-based spatial filtering, which seeks to improve the quality of information used by turbine- and farm-level controllers by combining measurements of the wind field collected at the individual turbines. The latter method has been shown to improve the estimates of wind direction at the turbines; however, the resulting potential for increased power capture warrants further investigation. With this paper, we begin to address this gap by combining wake steering with wind direction spatial filtering. To do so, we present a preliminary method for assessing the power capture of dynamic controllers using wind farm codes designed for time-averaged simulation. This allows us to generate results much more rapidly than would be possible using high-fidelity wind farm simulators and may be useful in many wind farm control design applications.

17 WIND ENERGY↗

Carbon dioxide capture from power or process plant gases

The present invention are methods for removing preselected substances from a mixed flue gas stream characterized by cooling said mixed flue gas by direct contact with a quench liquid to condense at least one preselected substance and form a cooled flue gas without substantial ice formation on a heat exchanger. After cooling additional process methods utilizing a cryogenic approach and physical concentration and separation or pressurization and sorbent capture may be utilized to selectively remove these materials from the mixed flue gas resulting in a clean flue gas.

54 ENVIRONMENTAL SCIENCES↗