Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A0535+26 - Refined position measurement and new pulse period data

The hard, pulsing, transient X-ray source A0535+26 has been observed with SAS 3 on three occasions during 1977-1978. These observations have yielded a precise position measurement (20 arcsec error radius), which renders the identification of A0535+26 with the Be star HDE 245770 virtually certain. The pulse phase was tracked for about 9 days in April 1978 and clearly showed both first and second derivatives in the pulse period. An analysis of these timing data, combined with data from previous observations, leads to the following conclusions: (1) a significant fraction of the observed changes in pulse period is probably intrinsic to the compact X-ray star (e.g., accretion torques on a neutron star), and (2) conservative limits on binary orbital parameters tend to further confirm a long orbital period (at least about 20 days).

Li, F.↗

Measuring Positions of Objects using Two or More Cameras

An improved method of computing positions of objects from digitized images acquired by two or more cameras (see figure) has been developed for use in tracking debris shed by a spacecraft during and shortly after launch. The method is also readily adaptable to such applications as (1) tracking moving and possibly interacting objects in other settings in order to determine causes of accidents and (2) measuring positions of stationary objects, as in surveying. Images acquired by cameras fixed to the ground and/or cameras mounted on tracking telescopes can be used in this method. In this method, processing of image data starts with creation of detailed computer- aided design (CAD) models of the objects to be tracked. By rotating, translating, resizing, and overlaying the models with digitized camera images, parameters that characterize the position and orientation of the camera can be determined. The final position error depends on how well the centroids of the objects in the images are measured; how accurately the centroids are interpolated for synchronization of cameras; and how effectively matches are made to determine rotation, scaling, and translation parameters. The method involves use of the perspective camera model (also denoted the point camera model), which is one of several mathematical models developed over the years to represent the relationships between external coordinates of objects and the coordinates of the objects as they appear on the image plane in a camera. The method also involves extensive use of the affine camera model, in which the distance from the camera to an object (or to a small feature on an object) is assumed to be much greater than the size of the object (or feature), resulting in a truly two-dimensional image. The affine camera model does not require advance knowledge of the positions and orientations of the cameras. This is because ultimately, positions and orientations of the cameras and of all objects are computed in a coordinate system attached to one object as defined in its CAD model.

Klinko, Steve↗

Line Intensity and Position Measurements and Derived Band Parameters of the 31103-00001 C-12 O-16(2) Band and its Two Nearby Hot Bands

A set of CO2 spectra from 4500 to 4780/cm has been obtained an Ames with 1500 m path length using a Bomem DA8 FTS. This spectral region contains a number of weak bands and minor isotopic bands that have been studied at high resolution in the reflection spectrum of Venus by Mandin. Improved laboratory intensity and position measurements should assist modeling the Venus reflection spectra and improve understanding of Venus' upper atmosphere. Also, the laboratory measurements will assist DND intensity computations of weaker bands that cannot be measured, but which are nevertheless significant absorbers in Venus' hot, deep CO2, atmosphere. For example, some of the weaker bands that are members of the same polyads as the bands in this presentation lie in the nearby 2.3 microns emission window in Venus' night-side spectrum.

Giver, Lawrence P.↗

NGEE Arctic Tram: Overview of Tram-mounted Instruments, Co-located Data, Measurement Position, Elevation and Polygon Characterization, Utqiagvik (Barrow), Alaska, 2014-2018

The NGEE-Arctic Tram operated from 2014 - 2018. It was installed on the Barrow Environmental Observatory in Barrow, Alaska in late May of 2014 and operated through mid-November 2014. The subsequent 2015 through 2018 years followed a similar schedule, but with different deployment dates and data gaps, with the goal always to capture the surface dynamics of the snow melt, growing, and freeze-up seasons. This Tram overview dataset has three objectives: (1) provide new data users with a brief description of the Tram system and its research purposes; (2) provide generally useful Tram site characterization details, including measurement position ground surface elevation, characteristics of the Arctic polygonal tundra under the Tram, vegetation community composition (future), and derived image products; and (3) reference all of the data products and archived datasets that were collected with the Tram-mounted sensors and co-located instruments. This dataset contains two csv files, two zipped files, one tif file, and one pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

SHAPES - Spatial, High-Accuracy, Position-Encoding Sensor for multi-point, 3-D position measurement of large flexible structures

An electro-optical position sensor for precise simultaneous measurement of the 3-D positions of multiple points on large space structures is described. The sensor data rate is sufficient for most control purposes. Range is determined by time-of-flight correlation of short laser pulses returned from retroreflector targets using a streak tube/CCD detector. Angular position is determined from target image locations on a second CCD. Experimental verification of dynamic ranging to multiple targets is discussed.

Nerheim, N. M↗

Polarization and position measurements of Type III bursts

The positional and polarization characteristics of Type III bursts in the range 24-220 MHz as measured by the Culgoora radioheliograph, spectrograph and spectropolarimeter are reported. The study includes 997 bursts which are of two classes: fundamental-harmonic (F-H) pairs and 'structureless' bursts with no visible F-H structure, and concentrates on the polarization of the bursts and the variation of polarization from centre to limb. The observed centre-to-limb decrease in polarization approximately follows a cosine law. This decrease is not as predicted by simple theory but is consistent with other observations which imply that open field lines from an active region diverge strongly. The observed o-mode polarization of harmonic radiation implies that the wave vectors of Langmuir waves are always parallel, within about 20 deg, to the magnetic field, while the constancy of H polarization with frequency implies that the ratio of gyromagnetic to plasma frequency, the Alfven speed and the plasma beta are constant with height on the open field lines above an active region. Finally, it is inferred that some factor, in addition to the magnetic field strength, controls the polarization of F radiation.

Suzuki, S.↗

Instrumented Glove Measures Positions Of Fingers

Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

Bozeman, Richard J., Jr.↗

Electro-optical Position-Measuring System

Electro-optical system developed to measure five components of coordinates representing position and orientation of model in test section of wind tunnel. Located entirely outside test section, uses small lasers as sources of light and self-scanning linear photodiode arrays (LPDA's) as sensing elements. With improvements in measuring ranges, adapted for use in other aerodynamic applications.

Tcheng, Ping↗

A statistical analysis of the beam position measurement in the Los Alamos proton storage ring

The beam position monitors (BPMs) are the main diagnostic in the Los Alamos Proton Storage Ring (PSR). They are used in several applications during operations and tuning including orbit bumps and measurements of the tune, closed orbit (CO), and injection offset. However the BPM data acquisition system makes use of older technologies, such as matrix switches, that could lead to faulty measurements. This is the first statistical study of the PSR BPM perfonnance using BPM measurements. In this study, 101 consecutive CO measurements are analyzed. Reported here are the results of the statistical analysis, tune and CO measurement spreads, the BPM single turn measurement error, and examples of the observed data acquisition errors.

43 PARTICLE ACCELERATORS↗

Multi-bit quantum random number generation by measuring positions of arrival photons

We report upon the realization of a novel multi-bit optical quantum random number generator by continuously measuring the arrival positions of photon emitted from a LED using MCP-based WSA photon counting imaging detector. A spatial encoding method is proposed to extract multi-bits random number from the position coordinates of each detected photon. The randomness of bits sequence relies on the intrinsic randomness of the quantum physical processes of photonic emission and subsequent photoelectric conversion. A prototype has been built and the random bit generation rate could reach 8 Mbit/s, with random bit generation efficiency of 16 bits per detected photon. FPGA implementation of Huffman coding is proposed to reduce the bias of raw extracted random bits. The random numbers passed all tests for physical random number generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

"DIAGNOSTIC" PULSE FOR SINGLE-PARTICLE-LIKE BEAM POSITION MEASUREMENTS DURING ACCUMULATION/PRODUCTION MODE IN THE LOS ALAMOS PROTON STORAGE RING

Beam position monitors (BPMs) are the primary diagnostic in the Los Alamos Proton Storage Ring (PSR). When injecting one turn, the transversemotion is approximated as a single particle with initial betatron position and angle {rvec x}{sub 0} and {rvec x}'{sub 0}. With single-turn injection, we fit the betatron tune, closed orbit (CO), and injection offset ({rvec x}{sub 0} and {rvec x}'{sub 0} at the injection point) to the turn-by-turn beam position. In production mode, we accumulate multiple turns, the transverse phase space fills after 5 injections (horizontal and vertical fractional betatron tunes {approx}0.2) resulting in no coherent betatron motion, and only the CO may be measured. The injection offset, which determines the accumulated beam size and is very sensitive to steering upstream of the ring, is not measurable in production mode. We describe our approach and ongoing efforts to measure the injection offset during production mode by injecting a 'diagnostic' pulse {approx}50 {micro}s after the accumulated beam is extracted. We also study the effects of increasing the linac RF gate length to accommodate the diagnostic pulse on the production beam position, transverse size, and loss.

43 PARTICLE ACCELERATORS↗

A beam profile and position measurement system for the IPF target

Currently one determines the size and position of the proton beam at the IPF target using plastic films. These films are installed in a target carrier, lowered into position, exposed to the beam, raised back up to the hot cell, removed from the target carrier, and assessed via a video feed. About an hour is required for each cycle of measurement. Because of this high cost in terms of time the users usually settle for a beam that is good enough to meet their needs, but not as good as they would like. I propose here a diagnostic device that would enable a measurement of under two seconds. This would enable delivery of a better-quality beam in less time.

43 PARTICLE ACCELERATORS↗

Teleportation of atomic states via position measurements

We present a scheme for conditionally teleporting an unknown atomic state in cavity QED, which requires two atoms and one cavity mode. The translational degrees of freedom of the atoms are taken into account using the optical Stern-Gerlach model. We show that successful teleportation with probability 1/2 can be achieved through local measurements of the cavity photon number and atomic positions. Neither direct projection onto highly entangled states nor holonomous interaction-time constraints are required.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic and X-ray Diagnostics for Plasma Position Measurements in the Ignition Experiment Ignitor

The ignition experiment Ignitor will produce high performance plasma regimes with neutron fluxes at the first wall comparable to those expected in power generating reactors (10{sup 15} n/ cm{sup 2}/ s at the first wall). An appreciable degradation of the inorganic insulators surrounding the conductors is expected and the measurement of basic plasma parameters, such as plasma current and position, by electromagnetic diagnostics can become problematic. Thus an R and D program, aimed at the development of effective and affordable devices for electromagnetic diagnostics with higher damage threshold, is being carried out. Prototype diagnostic coils of different shapes have been manufactured, in collaboration with SALENTEC and Universita di Lecce. At the same time, an alternative plasma position control method is being explored, based on the diffraction and detection of the soft X-ray radiation emitted, mostly by Molybdenum impurities, near the top or bottom of the plasma column, where the distance of the plasma last closed magnetic surface from the wall is only few millimeters. The underlying principles and general layout of the new system is essentially an adaptation of a 2-dimensional curved crystal spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Position measurements in the de Broglie-Bohm interpretation of quantum mechanics

The de Broglie-Bohm interpretation of quantum mechanics assigns positions and trajectories to particles. We analyze the validity of a formula for the velocities of Bohmian particles which makes the analysis of these trajectories particularly simple. We apply it to particle detectors of four different types and show that the detectors of three of these types lead to 'surrealistic trajectories', i.e., leave a trace where the Bohmian particle was not present. - Highlights: Black-Right-Pointing-Pointer We perform computer simulation of Bohmian trajectories for position detectors. Black-Right-Pointing-Pointer A simplified velocity formula provides very precise (or exact) Bohmian trajectories. Black-Right-Pointing-Pointer Spin, phase, and Bohmian velocity type detectors exhibit surrealistic trajectories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗