Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PORFLOW Implementation of Vadose Zone Conceptual Model for Naval Reactor Component Disposal Areas in the E-Area Low Level Waste Facility Performance Assessment

PORFLOW models have been developed to implement the proposed conceptual models for the two Naval Reactor Component Disposal Areas (NRCDAs), 643-7E and 643-26E, for the purpose of evaluating dose impacts and producing disposal limits for the E-Area Low-Level Facility (LLWF). New NRCDA conceptual models were proposed by Wohlwend and Butcher (2019) for two areas within/adjacent to the E-Area LLWF used as storage/disposal sites for reactor components from the U.S. Navy since 1987. Naval Reactor (NR) waste is comprised of highly radioactive components consisting of activated corrosion-resistant metal alloy contained within welded thick-walled steel casks, and auxiliary equipment primarily contaminated with lower levels of Activated Corrosion Products (ACPs) residing on the metal surfaces and contained within thinner-walled bolted containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Goldsim Modeling of Vadose Zone Transport for E-Area Naval Reactor Component Disposal Areas: Model Description and Benchmarking

This report documents the development of a GoldSim® model of flow and radionuclide transport to the water table through the Naval Reactor Components Disposal Area (NRCDA) waste disposal sites and underlying vadose zones. The model is designed to be used for Monte Carlo uncertainty analysis in support of the E-Area Performance Assessment (PA). This report describes the model and shows results obtained from benchmarking the model to best-estimate deterministic results obtained using a PORFLOW model of NRCDA vadose zone transport. The PORFLOW model is three-dimensional while the GoldSim model is a simplified one-dimensional treatment. Nevertheless, the GoldSim model was able to accurately reproduce PORFLOW results with some adjustment to the nominal dispersion coefficient and vadose zone flow area used as “tuning” parameters. An example of the results obtained comparing GoldSim and PORFLOW calculation of releases of I-129, Tc-99, C-14 and Ni-59 from waste disposal containers at the 643-26E site is shown in Figure 1 below. For all of the test cases evaluated, GoldSim predicted peak concentrations within 6% of the PORFLOW values and peak times agreed within 8% with the majority of the results in better agreement. The close agreement between the two models provides confidence that GoldSim will give results accurately reflecting the behavior of releases from the NRCDA under off-normal operating conditions for sensitivity and uncertainty analysis

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infiltration Data Package for the E-Area Low-Level Waste Facility Performance Assessment

The infiltration data package contains the input parameters, the cap design and material properties assumptions, and the modeling results for the Hydrologic Evaluation of Landfill Performance (HELP) infiltration model simulations performed in support of the E-Area Low-Level Waste Facility Performance Assessment (PA). The infiltration estimates establish the upper boundary condition for the PORFLOW vadose-zone model and GoldSim model simulations for the following E-Area disposal unit types: Slit and Engineered Trenches, Low-Activity Waste Vault (LAWV), Intermediate-Level Vault (ILV), Componentin- Grout (CIG) special waste form trench segments, and the Naval Reactor Component Disposal Areas (NRCDAs). The infiltration data package builds upon relevant, foundational PA technical reports and memoranda from the past 15 years and is supported by three important components: the HELP model input parameter datasheets, HELP model input and output filenames and directory structure, and infiltration rates as a function of time for each scenario for each disposal unit type. For Slit and Engineered Trenches, a single best-estimate Bahia-grass case of two-percent slope and 585- foot slope length represents an upper bound on intact closure-cap infiltration rates over a 10,000-year period. Building upon the single, bounding, and intact case, two different approaches were considered for incorporating the effect of localized cap subsidence on infiltration rates in the PORFLOW flow and transport model simulations. In the first approach, a Monte Carlo probabilistic model was developed to calculate infiltration rates for 0.54%, 2%, 3.6%, and 4.9% subsidence scenariosa reflecting historical and future non-crushable content for the Slit and Engineered Trenches. The resulting blended (spatially and slope-length averaged) infiltration rates become an inflow upper boundary condition for the PORFLOW vadose zone model simulations. In the second and preferred approach, a Monte Carlo rectangle packing algorithm (Danielson, 2019) and a simplified equation for the total mass flux of water draining into a subsided compartment (Equation 1) will be employed to implement a weighted blending of radionuclide fluxes to the water table using the results of deterministic PORFLOW vadose zone simulations representative of specific subsidence cases. Finally, HELP-model results from sensitivity studies of the intact infiltration case were fit to a log-logistic function to generate infiltration profiles over a 10,000-year period for most-optimistic, more-optimistic, best-estimate, more-pessimistic, and most-pessimistic cases, for both the intact and four subsidence scenarios. For the LAWV and IL vaults, infiltration rate profiles for a 10,000-year period were developed for both an on-vault (above the concrete/metal vault roof) and an off-vault (10-foot soil zone adjacent to vault walls) scenario. The purpose of the off-vault simulations was to confirm that subsurface runoff from the concrete vault roof will adequately drain through the lowermost backfill layers adjacent to the vault walls. The LAWV and ILV infiltration profiles assume collapse of the concrete roof at relative Years 2,905 and 7,100, respectively. The identical Bahia-grass case with two-percent slope and 585-foot slope length assumed for the Slit and Engineered Trenches will represent an upper bound on intact infiltration rates for the NRCDAs and CIG special waste form as well. While the NRCDA casks are assumed to remain structurally intact (i.e., non-assumed to collapse 300 years after the end of operations. Because both rows of the existing CIG trench segments in ST23 (formerly CIG01) extend across the planned cap crest, the subsided CIG trench segments are treated conservatively in the HELP model as a 100%-subsidence case with zero subsurface run-on. The CIG special waste form trench segment infiltration profile, therefore, consists of an intact-cap period from relative Year 100 to Year 300, followed by a 100%-subsidence period from relative Year 300 to Year 10,100.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

235-F GoldSim Fate and Transport Model: Uncertainty Quantification

Building 235-F was configured with two missions in mind: Actinide Billet Line (ABL) and the fabrication of Pu-238 oxide for space program applications. ABL produced Np-237 billets for use in SRS reactors, whereas the design process, fabrication, and examination of Pu-238 oxide powder occurred within the following areas, respectively: Plutonium Experimental Facility (PEF), Plutonium Fuel Form (PuFF), and Old Metallography Lab (OML). By 1990 production ceased and by 2006 de-inventory occurred; however, assays have shown significant holdup remains within ABL and PuFF. As a result, 235-F is a Category 2 nuclear facility, with plans to undergo deactivation and decommission (D and D) via In-Situ Disposal (ISD). The purpose of this project is to ensure United States Environmental Protection Agency (USEPA) groundwater radiation maximum contaminant level (MCL) and dosage standards are met during the D and D of 235-F by quantifying uncertainty through probabilistic modeling and evaluation of various ISD alternatives. GoldSim is a dynamic modeling software package with a graphical, object-oriented interface capable of capturing the influence of complex system input variability on probabilistic system outcomes. A GoldSim stochastic fate and transport model for 235-F was developed and matched with a PORFLOW deterministic model to simulate probabilistic release and flow of radionuclides from ABL and PuFF into the vadose zone, the Upper Three Runs (UTR) Aquifer, and UTR Creek. The GoldSim model was used to probabilistically evaluate four ISD scenarios against USEPA groundwater radiation MCLs and dosage standards. The deterministic 235-F GoldSim fate and transport model continues to be refined to match the results of the PORFLOW deterministic model to ensure the model accurately represents radionuclide movement through the groundwater system. The stochastic variables that are utilized within the GoldSim model are founded on the most current data; a conservative perspective is taken where needed. Alignment with the PORFLOW deterministic model, coupled with input stochastic variability, allows the probabilistic 235-F GoldSim model to capture the conservative breadth of possible outcomes for radionuclide fate within this particular system. This ensures that the USEPA MCLs and dosage limits hold even in the worst case scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Updated GSA Groundwater Flow Models on the FTF, HTF and SDF PAs

Savannah River Remediation (SRR) requested that the Savannah River National Laboratory (SRNL) evaluate the impacts of an updated General Separations Area (GSA) groundwater flow model on the F-Area Tank Farm (FTF), H-Area Tank Farm (HTF) and Saltstone Disposal Facility (SDF) Performance Assessments (PAs)1. For each facility, PORFLOW simulations were performed using both the 2004 GSA/PORFLOW (i.e., GSA_2004) and GSA2016 (i.e., GSA_2016) flow models. Overall, GSA_2004 and “_reference” (i.e., the archived data) results are practically identical, indicating GSA_2004 simulations reproduce the archived data very well. Compared with GSA_2004 data, the PEST.47 GSA_2016 results (with PORFLOW harmonic averaging at cell faces and diagonal terms in the dispersion tensor) support the following findings.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

E-Area Low-Level Waste Facility GoldSim System Model

This report documents the development of the E-Area Low-Level Waste Facility (ELLWF) trench system model. The GoldSim® Monte Carlo simulation software is utilized to model the release and transport of radiological inventory disposed (both currently and in the future) within Engineered and Slit Trenches. This model is in support of the sensitivity and uncertainty analysis for the ELLWF Performance Assessment. The ELLWF system model utilizes a hybrid-approach to accurately describe the disposal system. The Hydrologic Evaluation of Landfill Performance model provides the infiltration data to both PORFLOW and GoldSim. PORFLOW is used to calibrate the GoldSim model to ensure confidence in the stochastic results. Finally, the concentrations from GoldSim transport simulations are fed into the SRNL Dose Toolkit to calculate dose impacts and assess plume interaction

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Appendix H

This section provides supporting material for the development of DU-specific final inventory limits for the GW pathways for every generic waste form and SWF parent radionuclide requiring an inventory limit. The final inventory limits are based on nominal PA transport simulations using PORFLOW as reported in Chapter 5. The nominal PA settings represent the compliance case where some modeling parameter settings are defined based on conservative (pessimistically leaning) arguments. In the overall computational approach employed in this PA, a multitiered radionuclide screening process is adopted as discussed in Chapter 2, Section 2.3.7. In the multitiered process, the initial list of 1,252 parent radionuclides is shortened substantially using conservative, but simple, transport models, along with a reasonably low cutoff criterion of 0.1% SOF value. Multidimensional PORFLOW flow and transport modeling is employed for every parent radionuclide that failed the GW screening. The generic waste form limits represent Tier-3 analyses, while Tier-4 analyses are employed for SWF limits, where warranted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NUMERICAL FLOW AND TRANSPORT SIMULATIONS SUPPORTING THE SALTSTONE FACILITY PERFORMANCE ASSESSMENT

The Saltstone Disposal Facility Performance Assessment (PA) is being revised to incorporate requirements of Section 3116 of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005 (NDAA), and updated data and understanding of vault performance since the 1992 PA (Cook and Fowler 1992) and related Special Analyses. A hybrid approach was chosen for modeling contaminant transport from vaults and future disposal cells to exposure points. A higher resolution, largely deterministic, analysis is performed on a best-estimate Base Case scenario using the PORFLOW numerical analysis code. a few additional sensitivity cases are simulated to examine alternative scenarios and parameter settings. Stochastic analysis is performed on a simpler representation of the SDF system using the GoldSim code to estimate uncertainty and sensitivity about the Base Case. This report describes development of PORFLOW models supporting the SDF PA, and presents sample results to illustrate model behaviors and define impacts relative to key facility performance objectives. The SDF PA document, when issued, should be consulted for a comprehensive presentation of results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

GoldSim E-Area Low-Level Waste Facility Aquifer Zone Model Calibration Methodology

This report documents the development and calibration of the E-Area Low-Level Waste Facility (ELLWF) Gold Sim aquifer model. It provides a methodology on how a Gold Sim aquifer model can be calibrated to specific PORFLOW-based aquifer predictions. The calibration activity presented within this report focuses on the Slit Trench #06 (ST06) location that resides within the center set of Slit Trenches. This Gold Sim-based aquifer model is a generic model capable of being calibrated to any of the other trench locations within E-Area. In addition, subsequent activities (beyond the scope of this effort) will couple this GoldSim-based aquifer model to various GoldSim-based trench models, with the intent of performing stochastic analyses that couple all pertinent fate and transport processes from the ground surface up to the 100-m point of assessment (POA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Analysis for Saltstone Disposal Unit Column Degradation Analyses

PORFLOW related analyses supporting a Sensitivity Analysis for Saltstone Disposal Unit (SDU) column degradation were performed. Previous analyses, Flach and Taylor 2014, used a model in which the SDU columns degraded in a piecewise manner from the top and bottom simultaneously. The current analyses employs a model in which all pieces of the column degrade at the same time. Information was extracted from the analyses which may be useful in determining the distribution of Tc-99 in the various SDUs throughout time and in determining flow balances for the SDUs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Velocity field calculation for non-orthogonal numerical grids

Computational grids containing cell faces that do not align with an orthogonal (e.g. Cartesian, cylindrical) coordinate system are routinely encountered in porous-medium numerical simulations. Such grids are referred to in this study as non-orthogonal grids because some cell faces are not orthogonal to a coordinate system plane (e.g. xy, yz or xz plane in Cartesian coordinates). Non-orthogonal grids are routinely encountered at the Savannah River Site in porous-medium flow simulations for Performance Assessments and groundwater flow modeling. Examples include grid lines that conform to the sloping roof of a waste tank or disposal unit in a 2D Performance Assessment simulation, and grid surfaces that conform to undulating stratigraphic surfaces in a 3D groundwater flow model. Particle tracking is routinely performed after a porous-medium numerical flow simulation to better understand the dynamics of the flow field and/or as an approximate indication of the trajectory and timing of advective solute transport. Particle tracks are computed by integrating the velocity field from cell to cell starting from designated seed (starting) positions. An accurate velocity field is required to attain accurate particle tracks. However, many numerical simulation codes report only the volumetric flowrate (e.g. PORFLOW) and/or flux (flowrate divided by area) crossing cell faces. For an orthogonal grid, the normal flux at a cell face is a component of the Darcy velocity vector in the coordinate system, and the pore velocity for particle tracking is attained by dividing by water content. For a non-orthogonal grid, the flux normal to a cell face that lies outside a coordinate plane is not a true component of velocity with respect to the coordinate system. Nonetheless, normal fluxes are often taken as Darcy velocity components, either naively or with accepted approximation. To enable accurate particle tracking or otherwise present an accurate depiction of the velocity field for a non-orthogonal grid, Darcy velocity components are rigorously derived in this study from normal fluxes to cell faces, which are assumed to be provided by or readily computed from porous-medium simulation code output. The normal fluxes are presumed to satisfy mass balances for every computational cell, and if so, the derived velocity fields are consistent with these mass balances. Derivations are provided for general two-dimensional quadrilateral and three-dimensional hexagonal systems, and for the commonly encountered special cases of perfectly vertical side faces in 2D and 3D and a rectangular footprint in 3D.

97 MATHEMATICS AND COMPUTING↗

Development and Demonstration of Material Properties Database and Software for the Simulation of Flow Properties in Cementitious Materials

This report describes work performed by the Savannah River National Laboratory (SRNL) in fiscal year 2014 to develop a new Cementitious Barriers Project (CBP) software module designated as FLOExcel. FLOExcel incorporates a uniform database to capture material characterization data and a GoldSim model to define flow properties for both intact and fractured cementitious materials and estimate Darcy velocity based on specified hydraulic head gradient and matric tension. The software module includes hydraulic parameters for intact cementitious and granular materials in the database and a standalone GoldSim framework to manipulate the data. The database will be updated with new data as it comes available. The software module will later be integrated into the next release of the CBP Toolbox, Version 3.0. This report documents the development efforts for this software module. The FY14 activities described in this report focused on the following two items that form the FLOExcel package; 1) Development of a uniform database to capture CBP data for cementitious materials. In particular, the inclusion and use of hydraulic properties of the materials are emphasized; and 2) Development of algorithms and a GoldSim User Interface to calculate hydraulic flow properties of degraded and fractured cementitious materials. Hydraulic properties are required in a simulation of flow through cementitious materials such as Saltstone, waste tank fill grout, and concrete barriers. At SRNL these simulations have been performed using the PORFLOW code as part of Performance Assessments for salt waste disposal and waste tank closure.

97 MATHEMATICS AND COMPUTING↗

E-Area Low-Level Waste Facility Cover Overhang Analysis

PORFLOW related analyses were performed with a focus on Slit and Engineered Trenches to evaluate the minimum required cover overhang size that would prevent any adverse impact on the ELLWF overall performance. Cover overhang is defined as the lateral distance that a low-infiltration cover extends beyond the edge of the trench unit in any direction. Analyses were carried out for H-3 (short half-life), I-129 (very long half-life), and Sr-90 (moderate half-life with intermediate K d ) at different overhang sizes (5ft, 10ft, 20ft, 50ft, and infinite), cover timing (0yr, 10yr, 20yr, and 30yr), and scenarios (Intact and a limited Dynamic Compaction Case). H-3, I-129 and Sr-90 are representative of nuclides that typically drive the sum-of-fractions for a trench disposal unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose zone flow convergence test suite

Performance Assessment (PA) simulations for engineered disposal systems at the Savannah River Site involve highly contrasting materials and moisture conditions at and near saturation. These conditions cause severe convergence difficulties that typically result in unacceptable convergence or long simulation times or excessive analyst effort. Adequate convergence is usually achieved in a trial-anderror manner by applying under-relaxation to the Saturation or Pressure variable, in a series of everdecreasing RELAxation values. SRNL would like a more efficient scheme implemented inside PORFLOW to achieve flow convergence in a more reliable and efficient manner. To this end, a suite of test problems that illustrate these convergence problems is provided to facilitate diagnosis and development of an improved convergence strategy. The attached files are being transmitted to you describing the test problem and proposed resolution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater flow simulation of the Savannah River Site general separations area

The most recent groundwater flow model of the General Separations Area, Savannah River Site, is referred to as the “GSA/PORFLOW” model. GSA/PORFLOW was developed in 2004 by porting an existing General Separations Area groundwater flow model from the FACT code to the PORFLOW code. The preceding “GSA/FACT” model was developed in 1997 using characterization and monitoring data through the mid-1990’s. Both models were manually calibrated to field data. Significantly more field data have been acquired since the 1990’s and model calibration using mathematical optimization software has become routine and recommended practice. The current task involved updating the GSA/PORFLOW model using selected field data current through at least 2015, and use of the PEST code to calibrate the model and quantify parameter uncertainty. This new GSA groundwater flow model is named “GSA2016” in reference to the year in which most development occurred. The GSA2016 model update is intended to address issues raised by the DOE Low-Level Waste (LLW) Disposal Facility Federal Review Group (LFRG) in a 2008 review of the E-Area Performance Assessment, and by the Nuclear Regulatory Commission in reviews of tank closure and Saltstone Disposal Facility Performance Assessments.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Factors that Influence Infiltration Rates using the HELP Model

The Hydrologic Evaluation of Landfill Performance (HELP) model is used by Savannah River National Laboratory (SRNL) in conjunction with PORFLOW groundwater flow simulation software to make longterm predictions of the fate and transport of radionuclides in the environment at radiological waste sites. The work summarized in this report supports preparation of the planned 2018 Performance Assessment for the E-Area Low-Level Waste Facility (LLWF) at the Savannah River Site (SRS). More specifically, this project focused on conducting a sensitivity analysis of infiltration (i.e., the rate at which water travels vertically in soil) through the proposed E-Area LLWF closure cap. A sensitivity analysis was completed using HELP v3.95D to identify the cap design and material property parameters that most impact infiltration rates through the proposed closure cap for a 10,000-year simulation period. The results of the sensitivity analysis indicate that saturated hydraulic conductivity (Ksat) for select cap layers, precipitation rate, surface vegetation type, and geomembrane layer defect density are dominant factors limiting infiltration rate. Interestingly, calculated infiltration rates were substantially influenced by changes in the saturated hydraulic conductivity of the Upper Foundation and Lateral Drainage layers. For example, an order-of-magnitude decrease in Ksat for the Upper Foundation layer lowered the maximum infiltration rate from a base-case 11 inches per year to only two inches per year. Conversely, an order-of-magnitude increase in Ksat led to an increase in infiltration rate from 11 to 15 inches per year. This work and its results provide a framework for quantifying uncertainty in the radionuclide transport and dose models for the planned 2018 E-Area Performance Assessment. Future work will focus on the development of a nonlinear regression model for infiltration rate using Minitab 17® to facilitate execution of probabilistic simulations in the GoldSim® overall system model for the E-Area LLWF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

E-Area Low-Level Waste Facility Vadose Zone Model: Confirmation of Water Mass Balance for Subsidence Scenarios

In preparation for the next revision of the E-Area Low-Level Waste Facility (LLWF) Performance Assessment (PA), a mass balance model was developed in Microsoft Excel to confirm correct implementation of intact- and subsided-area infiltration profiles for the proposed closure cap in the PORFLOW vadose-zone model. The infiltration profiles are based on the results of Hydrologic Evaluation of Landfill Performance (HELP) model simulations for both intact and subsided cases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infiltration Time Profiles for E-Area LLWF Intact and Subsidence Scenarios

To support future Unreviewed Disposal Question Evaluations (UDQEs), Special Analyses (SAs) and/or Performance Assessments (PAs) for the E-Area Low-Level Waste Facility (LLWF) at the Savannah River Site (SRS), the Hydrologic Evaluation of Landfill Performance (HELP) model and a newly developed, Python-based, probabilistic model employing a Monte Carlo sampling technique were used together to generate infiltration degradation curves over a 10,000-year simulation period for both intact and subsided slit- and engineered-trench closure-cap scenarios. The results will be used in PORFLOW transport model simulations of the E-Area LLWF trench units.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗