Morphological Behavior of Compositionally Gradient Polystyrene− Polylactide Bottlebrush Copolymers
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Quartz Crystal Microbalance (QCM) has been used as a basis for many chemical sensors and biosensor. Its sensitivity to mass change which can detect a mass change on its surface down to sub ng/cm2 is one of its interesting aspects. Another interesting feature is its ability to work in liquid environment. However, there are many aspects which influence QCM sensor properties in contact with liquid. One of the aspects is surface roughness of the matrix layer where on top of it a biological sensitive layer will be immobilized. One of matrix layers in the immobilizing biological sensitive layer was polystyrene. Polystyrene was coated on the QCM sensor by using the spin coating method. During the coating process, polystyrene was solved using non-polar solvent. It is known that the physical and chemical properties of the solvent affect a transition process from soluble polymer becoming rigid polymer layer. In this work, we show that polystyrene solved in chloroform has a higher surface roughness compare to one solved in toluene, xylene, or tetrahydrofuran. Surface roughness of the polystyrene coating were measured using a non-contact profilometer. However, we also found that there is no difference on the electrical impedance of the QCM sensor coated with polystyrene resulted from differing solvent when the sensor was in contact with air and water. Thus, all of the mentioned solvent can be used to solve the polystyrene as a coating material for QCM sensor without affecting the electrical performance of the sensor, but the choice of the solution can be used as a simple method to control the difference roughness of the polystyrene coating.
Polystyrene is a familiar polymer with many commercial uses. Its applications range from the clear, high index of refraction, brittle plastic used to form audio cassette and CD cases to the foamed material used in insulated drink cups and packaging material. Polystyrene constitutes 11 percent of the plastics used in packaging with only High Density Polyethylene (HDPE) and Low Density Polyethylene (LDPE) contributing a larger share: so much polystyrene is used today, it is one of six common plastics that manufacturers have assigned an identification code. The code helps recycling efforts. Polystyrene's code is (PS code 6). During the summer and fall of 1992 several new polymeric experiments were developed by the NSF POLYED Scholars for introduction into the chemistry core curriculum. In this presentation, one such project will be discussed. This laboratory project is recommended for a first or second year laboratory course allowing the introduction of polymeric science to undergraduates at the earliest opportunity. The reliability of the experiments which make up this project and the recognition factor of polystyrene, a material we come in contact with everyday, makes the synthesis and characterization of polystyrene a good choice for the introduction of polymerization to undergraduates. This laboratory project appeals to the varied interests of students enrolled in the typical first year chemistry course and becomes an ideal way to introduce polymers to a wide variety of science and engineering students.
Controllable surface morphology is requisite across a gamut of processes, industries, and applications. The surface morphology of silica-coated polystyrene microspheres was controllably modified to enable generation of both smooth and bumpy, or raspberry-like, surfaces. Although smooth and raspberry-like silica shells on polystyrene templates have been demonstrated extensively, the method described here used readily available materials to produce radical changes in surface morphology from a single polystyrene template coated in silica through a facile sol-gel reaction processes. Silica shells were deposited via a sol-gel process (using tetraethyl orthosilicate as the silica precursor) onto 1 to 2 m diameter anionic polystyrene spheres, fabricated by emulsifier-free polymerization. By varying of the concentration of silica precursor and ammonium hydroxide catalyst and altering the electrostatic surface interactions via addition of a cationic polymeric brush, an array of surface topologies was generated. The resulting silica shells ranged from 100 to 200 nm in thickness, as measured by calcination of the polystyrene template. Empirical relations between reaction conditions and the resulting silica colloid diameter were utilized to understand the resultant silica shell topology. These results may serve as a guide to generate a versatile platform for research in the multitude of applications where polystyrene-silica core-shell particles are utilized.
A graphene layer was synthesized using chemical vapor deposition methods and a polystyrene solution was spin-cast onto the graphene film. The graphene-polystyrene bilayer membrane was attached between the two tines of a microfabricated quartz tuning fork (QTF). The modulus of the graphene-polystyrene bilayer was measured to be twice that of a pristine polystyrene membrane. Exposure of the membrane-coated QTF to ethanol vapor decreased the resonance frequency of the microresonator. The bilayer membrane-coated QTF produced a frequency change that was three times the change obtained using a polystyrene membrane-coated QTF, with a lower degree of degradation in the Q factor. The limit of detection of the bilayer membrane-coated QTF to ethanol vapor was determined to be 20 ppm.
Most methods for the oxidative deconstruction of polystyrene produce benzoic acid, which has a low market size relative to the production of waste polystyrene. Here, the present study demonstrates a method for conversion of polystyrene into terephthalic acid, a high-volume chemical, by introducing a carbon-containing fragment into the para position of the phenyl groups in polystyrene, followed by Mn/Br-catalyzed autoxidation. Acetylated polystyrene is shown to be the most effective substrate for oxidation, affording an 81% yield of terephthalic acid. Mechanistic studies highlight the effectiveness of bromide as a cocatalyst and offer insight into the underlying reasons the acetyl group undergoes efficient oxidation.
Photothermal conversion can promote plastic depolymerization (chemical recycling to a monomer) through light-to-heat conversion. The highly localized temperature gradient near the photothermal agent surface allows selective heating with spatial control not observed with bulk pyrolysis. However, identifying and incorporating practical photothermal agents into plastics for end-of-life depolymerization have not been realized. Interestingly, plastics containing carbon black as a pigment present an ideal opportunity for photothermal conversion recycling. Herein, we use visible light to depolymerize polystyrene plastics into styrene monomers by using the dye in commercial black plastics. A model system is evaluated by synthesizing polystyrene–carbon black composites and depolymerizing under white LED light irradiation, producing styrene monomer in up to 60% yield. Excitingly, unmodified postconsumer black polystyrene samples are successfully depolymerized to a styrene monomer without adding catalysts or solvents. Using focused solar irradiation, yields up to 80% are observed in just 5 min. Furthermore, combining multiple types of polystyrene plastics with a small percentage of black polystyrene plastic enables full depolymerization of the mixture. This simple method leverages existing plastic additives to actualize a closed-loop economy of all-colored plastics.
Atmospheric pressure plasma jets have great potential for the surface modification of polymers. In this work, the authors report on polystyrene etching by a radio frequency driven atmospheric pressure plasma jet with a focus on the role of H · , O · , and · OH radicals in this process. The absolute flux of H · , O · , and · OH radicals reaching the surface of the polymer was determined by a COMSOL MULTIPHYSICS reacting fluid dynamics model incorporating detailed transport phenomena in the boundary layer near the substrate. The simulated results of H · and · OH densities in the jet effluent were experimentally verified by two-photon absorption laser induced fluorescence and laser induced fluorescence, respectively. The carbon atom removal flux from the polystyrene surface was taken from previously reported measurements using the same plasma source. The authors show that the boundary layer effects in the interfacial region above the substrate can have a significant impact on the calculated etching probabilities. The reaction probability (β) has a significant uncertainty although a variation of 2 orders of magnitude in β leads to uncertainties of approximately 1 order of magnitude variation in the determined etching probability. The etching probability of polystyrene by · OH radicals was confirmed to be at least an order of magnitude larger than the polystyrene etching probability by O · radicals. The authors also confirmed the weak polystyrene etching probability by H · radicals. The model suggests that the presence of a 30 ppm O 2 impurity can lead to the production of · OH radicals in the far effluent of the Ar + 1% H 2 plasma jet close to the substrate at sufficient densities to enable effective etching.
Graphical abstract: Core–shell structure PSt/CuS were prepared using polystyrene which were modified by 3-methacryloxypropyltrimethoxysilane as template. The coating thickness of CuS can be controlled by the amount of 3-methacryloxypropyltrimethoxysilane and the UV–vis absorption intensity of PSt/CuS composite also changed with the coating thickness of CuS. Highlights: ► Core–shell structure PSt/CuS were prepared using silanol-modified polystyrene microspheres as template. ► The coating thickness of core–shell structure PSt/CuS can be controlled by a simple method. ► The UV–vis absorption intensity of PSt/CuS composite also changed with the coating thickness of CuS. -- Abstract: The silanol-modified polystyrene microspheres were prepared through dispersion polymerization. Then copper sulfide particles were grown on silanol-modified polystyrene through sonochemical deposition in an aqueous bath containing copper acetate and sulfide, released through the hydrolysis of thioacetamide. The resulting particles were continuous and uniform as characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Fourier transform infrared, thermogravimetric analysis and UV–vis absorption spectroscopy were used to characterize the structure and properties of core–shell particles. The results showed the coating thickness of CuS shell can be controlled by the amount of silanol and the UV–vis absorption intensity of PSt/CuS composite also changed with the coating thickness of CuS.
Purpose: Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice TRS 398 recommended that dose calibrations be performed with ionization chambers only in water phantoms because plastic-to-water dose conversion factors were not available with sufficient accuracy at the time of its writing. These factors are necessary, however, to evaluate the difference in doses delivered to patients if switching from calibration in plastic to a protocol that only allows calibration in water. Methods: This work measured polystyrene-to-water dose conversion factors for this purpose. Uncertainties in the results due to temperature, geometry, and chamber effects were minimized by using special experimental set-up procedures. The measurements were validated by Monte Carlo simulations. Results: At the peak of non-range-modulated beams, measured polystyrene-to-water factors ranged from 1.015 to 1.024 for beams with ranges from 36 to 315 mm. For beams with the same ranges and medium sized modulations, the factors ranged from 1.005 to 1.019. The measured results were used to generate tables of polystyrene-to-water dose conversion factors. Conclusions: The dose conversion factors can be used at clinical proton facilities to support beamline and patient specific dose per monitor unit calibrations performed in polystyrene phantoms.
Abstract An unprecedented mode of reactivity of Zn 4 O‐based metal–organic frameworks (MOFs) offers a straightforward and powerful approach to polymer‐hybridized porous solids. The concept is illustrated with the production of MOF‐5‐polystyrene wherein polystyrene is grafted and uniformly distributed throughout MOF‐5 crystals after heating in pure styrene for 4–24 h. The surface area and polystyrene content of the material can be fine‐tuned by controlling the duration of heating styrene in the presence of MOF‐5. Polystyrene grafting significantly alters the physical and chemical properties of pristine MOF‐5, which is evident from the unique guest adsorption properties (solvatochromic dye uptake and improved CO 2 capacity) as well as the dramatically improved hydrolytic stability of composite. Based on the fact that MOF‐5 is the best studied member of the structure class, and has been produced at scale by industry, these findings can be directly leveraged for a range of current applications.
Abstract An unprecedented mode of reactivity of Zn 4 O‐based metal–organic frameworks (MOFs) offers a straightforward and powerful approach to polymer‐hybridized porous solids. The concept is illustrated with the production of MOF‐5‐polystyrene wherein polystyrene is grafted and uniformly distributed throughout MOF‐5 crystals after heating in pure styrene for 4–24 h. The surface area and polystyrene content of the material can be fine‐tuned by controlling the duration of heating styrene in the presence of MOF‐5. Polystyrene grafting significantly alters the physical and chemical properties of pristine MOF‐5, which is evident from the unique guest adsorption properties (solvatochromic dye uptake and improved CO 2 capacity) as well as the dramatically improved hydrolytic stability of composite. Based on the fact that MOF‐5 is the best studied member of the structure class, and has been produced at scale by industry, these findings can be directly leveraged for a range of current applications.
Plant uptake of micro- and nanoplastics can lead to contamination of food with plastic particles and subsequent human consumption of plastics. There is evidence that plant roots can take up micro and nanoplastics; however, most of this evidence stems from experiments conducted with plants grown in hydroponics or agar systems where uptake of nanoparticles by roots is more favorable than when plants were grown in soil. Here, we discern the root uptake and accumulation of polystyrene nanospheres in plants grown in different growth media: agar, hydroponics, and soil. In addition, we tested the impacts of nanospheres on plant biomass and plant stress. Wheat and Arabidopsis thaliana were grown in agar, hydroponics, and soil media and exposed to polystyrene nanospheres. Three different nanospheres were used (40 nm and 200 nm carboxylate-modified and 200 nm amino-modified polystyrene) and uniformly mixed into the growth media. Plants were grown for 7 to 10 days and the roots were then examined for the presence of nanospheres by confocal laser scanning microscopy and scanning electron microscopy. Plant stress was evaluated by measuring reactive oxygen species (ROS). We observed the 40 nm nanospheres inside the plant roots, but the 200 nm nanospheres only adhered to the root cap cells showing no uptake into the roots. Furthermore, confocal images indicated that root uptake of nanospheres was favored in hydroponic solutions as compared to agar and soil media. Plant biomass was generally not affected by the nanospheres, except for hydroponically grown Arabidopsis thaliana, where biomass was significantly reduced. Small sized (40 nm) and positively charged (200 nm amino-modified) nanospheres showed higher ROS accumulation in plants than negatively charged 200 nm carboxylate-modified nanospheres. In conclusion, this study provides evidence that polystyrene nanospheres can be taken up into the interior of plant roots and cause plant stress, but these impacts are less pronounced in media where the plastic particles are less mobile, like in agar and soil media as compared to hydroponic systems.
Nano sized Pt particles were successfully immobilized onto SiO{sub 2} and polystyrene-encapsulated silica core shell (SiO{sub 2}@PS). To make the immobilization of Pt onto both silica and polystyrene-encapsulated silica core shell, SiO{sub 2} was first functionalized with -NH{sub 2} using 3-amino propyl trimethoxysilane (APTMS) while for core shell, the negatively charged surface of polystyrene (PS) was changed with positive charge by cationic surfactant such as cetyltrimethylammonium chloride (CTACl) to make the formation of SiO{sub 2} shell on preformed PS sphere. Transmission electron micrograph (TEM) images shows that Pt nanoparticles immobilized onto SiO{sub 2} and SiO{sub 2}@PS were to be 3-4 nm without agglomeraiton. The energy dispersive spectroscope (EDS) shows that Pt contents on both SiO{sub 2} and SiO{sub 2}@PS were to be 21.45% and 20.28%, respectively. In case of Pt-SiO{sub 2}@PS, it is believed that Pt should have been immobilized onto PS surface and pore within SiO{sub 2} shell as well as SiO{sub 2} surface. The MEA fabricated with Pt-SiO{sub 2}@PS shows better cell performance than of Pt-SiO{sub 2}.