Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Propagation characters of Gaussian laser beams in collisionless plasma: Effect of plasma temperature

This paper presents an investigation of the propagation characters of Gaussian laser beam in cold collisionless plasma by considering the plasma temperature variation. The ponderomotive nonlinearity is involved and induces the nonlinear self-focusing against spatial diffraction. The second-order differential equation of dimensionless beam width parameter f({xi}) in terms of plasma temperature is established from Maxwell's equations with paraxial approximation. The initial (P{sub 0},{rho}{sub 0}) plane, behaviors of f({xi}) parameter, and perturbed density n/nn{sub 0}n{sub 0} of different plasma temperatures are plotted and analyzed. The plasma temperature is divided into four regions, which leads to different propagation characters including oscillatory divergence, self-trapping, self-focusing, and steady divergence. The plasma density distribution modified by the electric field intensity and plasma temperature is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modified Fowler-Milne method for the spectroscopic determination of thermal plasma temperature without the measurement of continuum radiation

A technique based on the Fowler-Milne method for the spectroscopic determination of thermal plasma temperatures without measuring continuum radiation is presented. This technique avoids the influence of continuum radiation with the combined line and continuum emission coefficients to derive the plasma temperatures. The amount of continuum emission coefficient is estimated by using an expression related to the Biberman factors. Parameters that affect the accuracy of the proposed technique and errors in the measured plasma temperatures are analyzed. It is shown that, by using the Ar I 696.5 nm line with a bandwidth of 3.27 nm without taking into account the continuum radiation, the plasma temperature measured will be lower on the order of up to 1000-3000 K for temperatures from 20 000 to 24 000 K. The theoretically predicted temperature errors are in good agreement with the experimental results, indicating that the proposed technique is reliable for plasma temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Zeeman splitting measurements in a high-temperature plasma

The Zeeman effect has been used for measurement of magnetic fields in low-temperature plasma, but the diagnostic technique is difficult to implement in a high-temperature plasma. This paper describes new instrumentation and methodology for simultaneous measurement of the entire Doppler-broadened left and right circularly polarized Zeeman spectra in high-temperature plasmas. Measurements are made using spectra emitted parallel to the magnetic field by carbon impurities in high-temperature plasma. The Doppler-broadened width is much larger than the magnitude of the Zeeman splitting, thus simultaneous recording of the two circularly polarized Zeeman line profiles is key to accurate measurement of the magnetic field in the ZaP Z-pinch plasma device. Spectral data are collected along multiple chords on both sides of the symmetry axis of the plasma. This enables determination of the location of the current axis of the Z-pinch and of lower-bound estimates of the local magnetic field at specific radial locations in the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inactivation of possible micromycete food contaminants using the low-temperature plasma and hydrogen peroxide

The inhibition effect of hydrogen peroxide aerosol, low-temperature plasma and their combinations has been studied on several micromycetes spores. The low-temperature plasma was generated in corona discharges in the open air apparatus with hydrogen peroxide aerosol. Micromycete spores were inoculated on the surface of agar plates, exposed solely to the hydrogen peroxide aerosol, corona discharge or their combination. After incubation the diameter of inhibition zone was measured. The solely positive corona discharge exhibits no inactivation effect, the solely negative corona discharge and solely hydrogen peroxide aerosol exhibit the inactivation effect, however their combinations exhibit to be much more effective. Low-temperature plasma and hydrogen peroxide aerosol present a possible alternative method of microbial decontamination of food, food packages or other thermolabile materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The mass and speed dependence of meteor air plasma temperatures

The speed and mass dependence of meteor air plasma temperatures is perhaps the most important data needed to understand how small meteoroids chemically change the ambient atmosphere in their path and enrich the ablated meteoric organic matter with oxygen. Such chemistry can play an important role in creating prebiotic compounds. The excitation conditions in various air plasma emissions were measured from high-resolution optical spectra of Leonid storm meteors during NASA's Leonid Multi-Instrument Aircraft Campaign. This was the first time a sufficient number and range of temperature measurements were obtained to search for meteoroid mass and speed dependencies. We found slight increases in temperature with decreasing altitude, but otherwise nearly constant values for meteoroids with speeds between 35 and 72 km/s and masses between 10(-5) g and 1 g. We conclude that faster and more massive meteoroids produce a larger emission volume, but not a higher air plasma temperature. We speculate that the meteoric plasma may be in multiphase equilibrium with the ambient atmosphere, which could mean lower plasma temperatures in a CO(2)-rich early Earth atmosphere.

Temperature↗

Preface to the Proceedings of the 25th Topical Conference on High-Temperature Plasma Diagnostics

The 25th Topical Conference on High-Temperature Plasma Diagnostics (HTPD 2024) was held in Asheville, NC, USA, at the Renaissance Asheville Downtown Hotel from 21 to 25 April 2024. This biennial conference brings together scientists and engineers from a variety of fields, including magnetic confinement fusion, inertial confinement fusion, space plasmas, astrophysics, and industrial applications, to discuss mutual problems in the development of instrumentation and experimental techniques for the characterization of high-temperature plasmas. As the 25th meeting, HTPD 2024 represents ∼50 years of ongoing international collaboration on these topics.

Biewer, Theodore [ORNL] (ORCID:0000000174563509)↗

Non-Equilibrium in a Dust-Forming Low-Temperature Plasma: A CARS Study

Dust-forming low-temperature plasmas are versatile systems for the production of nanoparticles with tunable functionalities. While attractive from a materials processing point of view, these systems are inherently complex, with several plasma-induced phenomena determining the properties of the produced materials. Here, we characterize a carbon nanoparticle-forming plasma using coherent anti-Stokes Raman spectroscopy (CARS), with the primary goal of measuring gas temperature. While gas temperature is typically assumed to be at or slightly above room temperature in these reactors, we measure gas temperatures exceeding 1000 K under typical process conditions. We find a correlation between the gas temperature and the nanoparticle yield, suggesting that the particle nucleation and growth process releases energy within the reaction volume, leading to significant gas heating. In addition, we find that the relaxation of vibrationally excited species at the particle surfaces is a major contributor to their heating. In conclusion, these results underscore the complexity of these systems and the need for their more in-depth characterization using advanced techniques such as CARS.

Basic Plasma Phenomena and Gas Discharges↗

Thermal and Nonthermal Electron-ion Bremsstrahlung Spectrum from High-Temperature Plasmas

Electron-ion bremsstrahlung radiation from high-temperature plasmas is investigated. The first- and second-order Coulomb corrections in the nonrelativistic bremsstrahlung radiation power are obtained by the Elwert-Sommerfeld factor. In this paper, two cases of the electron distributions, the thermal and nonthermal power-law distributions, are considered. The inclusion of Coulomb corrections is necessary in deducing correctly the electron distribution function from radiation data. These results provide the correct information of electron distributions in high-temperature plasmas, such as in inertial confinement fusion plasmas and in the astrophysical hot thermal and nonthermal x-ray sources.

Jung, Young-Dae↗

Material for electrodes of low temperature plasma generators

Material for electrodes of low temperature plasma generators. The material contains a porous metal matrix impregnated with a material emitting electrons. The material uses a mixture of copper and iron powders as a porous metal matrix and a Group IIIB metal component such as Y.sub.2O.sub.3 is used as a material emitting electrons at, for example, the proportion of the components, mass %: iron:3-30; Y.sub.2O.sub.3:0.05-1; copper: the remainder. Copper provides a high level of heat conduction and electric conductance, iron decreases intensity of copper evaporation in the process of plasma creation providing increased strength and lifetime, Y.sub.2O.sub.3 provides decreasing of electronic work function and stability of arc burning. The material can be used for producing the electrodes of low temperature AC plasma generators used for destruction of liquid organic wastes, medical wastes, municipal wastes as well as for decontamination of low level radioactive waste, the destruction of chemical weapons, warfare toxic agents, etc.

Caplan, Malcolm↗

Material for electrodes of low temperature plasma generators

Material for electrodes of low temperature plasma generators. The material contains a porous metal matrix impregnated with a material emitting electrons. The material uses a mixture of copper and iron powders as a porous metal matrix and a Group IIIB metal component such as Y.sub.2O.sub.3 is used as a material emitting electrons at, for example, the proportion of the components, mass %: iron: 3-30; Y.sub.2O.sub.3:0.05-1; copper: the remainder. Copper provides a high level of heat conduction and electric conductance, iron decreases intensity of copper evaporation in the process of plasma creation providing increased strength and lifetime, Y.sub.2O.sub.3 provides decreasing of electronic work function and stability of arc burning. The material can be used for producing the electrodes of low temperature AC plasma generators used for destruction of liquid organic wastes, medical wastes, and municipal wastes as well as for decontamination of low level radioactive waste, the destruction of chemical weapons, warfare toxic agents, etc.

Caplan, Malcolm↗

Novel Low-Temperature Plasma Reactor for Industrial Applications

UV water disinfection for municipalities around the world is expected to grow over 15% annually, leading to a $2.8 billion dollar market by 2020. This growth is driving the need for higher power and more efficient UV sources. By far the greatest potential market for UV disinfection is drinking water. UV is now accepted as an available technology to deactivate Cryptosporidium and Giardia in surface water and other vulnerable sources. The output power of typical mercury-vapor UV lamps is limited to 30 W/m, requiring large arrays to treat relevant volumes of water. Higher power sources can be built with low-temperature plasmas, but require large, lossy, light-blocking magnetic cores. These cores require extensive cooling, and place a hard ceiling on power transfer to the plasma, optical efficiency, and ultimately on radiant light flux. In Phase I of this SBIR, DTI developed a novel, magnetically-coupled, toroidal pulsed plasma reactor that could run without ferrite cores, though the cores increased the coupling. DTI’s proposed geometry and exciter circuit topology enables the use of comparatively inexpensive electronic modules to operate in a pulsed-RF mode. The pulsed high-power discharge (1.5 MW peak, 500 kHz, < 5% duty cycle) creates high plasma temperatures for short durations, while maintaining a much lower steady-state temperature. This proposed reactor will be designed primarily to disinfect and denature wastewater or drinking water products, exploiting large-scale UV disinfection techniques. The UVC efficiency with the highest output power was 6.2%; for comparison, the efficiency of present high-power UV sources is 13%. It may be possible to increase the efficiency by operating pulses in a burst mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revealing low-temperature plasma efficacy through a dose-rate assessment by DNA damage detection combined with machine learning models

Low-temperature plasmas have quickly emerged as alternative and unconventional types of radiation that offer great promise for various clinical modalities. As with other types of radiation, the therapeutic efficacy and safety of low-temperature plasmas are ubiquitous concerns, and assessing their dose rates is crucial in clinical settings. Unfortunately, assessing the dose rates by standard dosimetric techniques has been challenging. To overcome this difficulty, we proposed a dose-rate assessment framework that combined the predictive modeling of plasma-induced damage in DNA by machine learning with existing radiation dose-DNA damage correlations. Our results indicated that low-temperature plasmas have a remarkably high dose rate that can be tuned by various process parameters. This attribute is beneficial for inducing radiobiological effects in a more controllable manner.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution hard x-ray spectroscopy of high-temperature plasmas using an array of quantum microcalorimeters

Quantum microcalorimeters show promise in being able to fully resolve x-ray spectra from heavy highly charged ions, such as would be found in hot plasmas with temperatures in excess of 50 keV. Quantum microcalorimeter arrays are able to achieve this as they have a high-resolving power and good effective quantum efficiency for hard x-ray photons up to 60 keV. To demonstrate this, we present a measurement using an array of thin HgTe quantum microcalorimeters to measure the K-shell spectrum of hydrogenlike through carbonlike praseodymium (Z=57). With this device we are able to attain a resolving power, E/{delta}E, of 1000 at a photon energy of 37 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of the high-temperature plasma in the 15 June 1973 flare

The evolution of the high-temperature plasma in the solar flare of June 15, 1973, is analyzed using XUV spectroheliograms obtained from Skylab. Preflare enhancement of loops in the active region is discussed, and the temperature and density of the hot plasma are determined as a function of time. The turbulent velocity in the high-temperature plasma is deduced from a comparison of line widths of the Fe XXIV doublet at 192 and 255 A. The results indicate that: (1) the flare occurred in a low-lying loop or loops; (2) the large-scale magnetic-field configuration of the active region did not change significantly; (3) the hot plasma observed in Fe XXIII-XXIV showed considerable dynamic activity, including an initial upward motion of the whole plasma with a velocity of about 80 km/s; (4) large turbulent mass motions took place in the Fe XXIII-XXIV plasma with random velocities of 100 to 160 km/s; (5) the temperature of the hot plasma was 14 million K at peak X-ray intensity, decreased slightly, and then remained at 12.6 million K before dropping to below 10 million K; and (6) there was a temperature gradient along the length of the loop, with the 14 million-K plasma near the top and progressively lower-temperature plasmas on either side.

Cheng, C.-C.↗

Fluid modeling of low-temperature plasmas

Fluid models are essential for understanding and predicting low-temperature plasma (LTP) behavior in various scientific and industrial settings. This paper provides an introductory tutorial on fluid modeling of LTPs, covering model formulation, implementation, and computational simulations. The tutorial focuses on five main components of the formulation of LTP fluid models: fluid flow, energy, chemistry, electromagnetism, and material properties, as well as in essential aspects of model implementations, including multiscale phenomena, multiphysics coupling, and numerical convergence. Designed for students and early-career researchers, this work offers a practical foundation for developing and using fluid models, from in-house computational codes to commercial software, bridging fundamental theory with real-world applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Temperature Plasma Treatment for Enhanced Recovery of Highly Valued Critical REEs from Coal (Final Report)

The principle objective of this project was to develop a novel process flowsheet using low-temperature plasma treatment (LTP) integrated with conventional hydrometallurgical processes to recover rare earth elements (REEs), especially highly valued REEs (i.e. scandium and critical REEs), from coal and coal byproducts. LTP treatment was used to pretreat the solid feed material prior to leaching in an effort to improve the leaching characteristics of the REEs and potentially reduce acid consumption. Initially, a detailed experimental program was performed on a laboratory LTP furnace to identify a set of process parameter values to be used for assessing the enhanced leaching performance achieved on four specific gravity fractions of West Kentucky No. 13 and Fire Clay coarse coal refuse materials. High-temperature oxidation (HTO)) was also evaluated as a means for improving REE leachability on the same fractions of both coal sources. The lixiviants used to assess leachability improvements included: i) untreated water, ii) 0.1 M ammonium sulfate solution and iii) 1.2 M sulfuric acid solution at a temperature of 75°C. The laboratory data was used to develop multiple process flow sheets using HTO only to produce a rare earth oxide mix concentrate or utilizing both LTP and HTO treatment processes to generate a high purity heavy REO mix concentrate and a light REO mix concentrate. A techno-economic analysis was performed on each circuit. Low-temperature plasma oxidation was found to enhance REE leaching characteristics for all specific gravity (SG) fractions of the West Kentucky No. 13 coarse refuse material. The leaching recovery improvement was preferentially achieved for the heavy REEs with higher values obtained when treating the lower density fraction material. For example, the leaching recovery for the heavy REEs in the untreated 1.6 SG Float fraction material was 8% in a 0.1 M ammonium sulfate solution. After LTP treatment for 32 hours, heavy REE recovery increased to 33%. The corresponding recovery value for the light REEs was 10%. These findings indicate a strong affinity of the heavy REEs with the organic material, which is the component being reduced in content during the LTP treatment. Scanning electron micrographs showed the development of a honeycomb structure with increased LTP treatment with higher surface area as confirmed from BET measurements. Higher surface area promotes improved leaching efficiency due to enhance chemical interactions. When using 1.2 M sulfuric acid, the LTP treatment was found to provide a heavy REE recovery increase from 23% to 53% for the 1.6 SG Float fraction which corresponded to an ash content increase from around 20% to 35%. However, LTP treatment provided no improvement in leaching characteristic for the 2.2 SG sink material in the acid solution, which was likely due to the low organic content. The LTP treatment of the Fire Clay SG fractions provided no improvement in REE leaching characteristic, which may be due to the association with REE minerals such as monazite and REE-associated mineral matter such as clays. High temperature oxidation using temperatures in the range of 600-750OC was found to significantly enhance the leaching characteristics of both the light and heavy REEs for all density fractions in both coarse coal refuse materials. Generally, the increase in light REE recovery for the West Kentucky material was from 15% for the untreated material to 90% for the HTO treated material at 600°C. Recovery values dropped significantly when using temperatures below 600°C and above 750°C. The impact of the excessive temperatures was most likely a result of sintering. For the heavy REEs, HTO significantly improved recovery in the lighter SG fractions, which may be due to an affinity with the organic content. Only limited heavy REE recovery improvement was obtained for the denser SG fractions. Another benefit of HTO is the conversion of calcium-based minerals to a very soluble calcium oxide, which is removable using a mild acid solution, and the conversion of Fe minerals to relatively insoluble minerals such as hematite and magnetite. The pregnant leaching solution produced from the leaching of all SG fractions obtained from both coal sources was treated using two stages of solvent extraction procedurally modeling a rougher-cleaner circuit followed by oxalic acid precipitation. Rare earth oxide products having a purity greater than 97% was produced from nearly all of the SG fractions. A novel process flowsheet was developed based on the selective leaching of heavy REEs that was made possible through LTP treatment of West Kentucky No. 13 coarse refuse followed by salt leaching. In the flowsheet, coal refuse material is ground to a top size of 1mm and then treated by LTP. The treated material is mixed into a 0.1 M ammonium sulfate solution and then filtered to produce a heavy REE enriched pregnant leach solution. The heavy REEs are concentrated by two stages of selective precipitation to produce a heavy REE mix oxalate and then roasted to obtain a heavy REO mix concentrate. The solid residues remaining after salt leaching is dried and then subjected to HTO treatment followed by concentration using selective precipitation and roasting to produce a light REO mix concentrate. An alternative circuit was developed using HTO treatment only to treat 100% of the coarse refuse material followed by selective precipitation and roasting to generate a high purity REO mix product. A techno-economic analysis performed for the treatment of West Kentucky No. 13 and Fire Clay coarse refuse based on a hypothetical 500-tph plant revealed that the net present value for all scenarios was significantly negative. Primary reasons include: i) a substantial decrease in the basket value of the final product relative to the feed and ii) high chemical costs relative to the amount of product generated. The basket value reduction was primarily due to little to no scandium recovery due to poor leaching characteristics when using low acid concentrations as necessitated by the low feed grades. Operating costs were primarily influenced by the chemical costs relative to the kilograms of concentrate produced and feed grade. For the Fire Clay coarse refuse material, the total operating cost was estimated to be $354 per kg of REO produced which was higher than the basket value of the REO product ($276/kg). Approximately 37% of the total cost was the sulfuric acid used during the leaching process. A comparative analysis performed to assess the economic viability of using low-temperature plasma furnaces found that market value enhancement for the generation of both heavy REO and light REO concentrates will be needed in addition to significant technology advancements to reduce the cost of plasma furnaces.

01 COAL, LIGNITE, AND PEAT↗