Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PID detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Construction of a Cosmic Ray Telescope for the hpDIRC Radiators at the Electron Ion Collider

Nuclear physics pertains to the understanding of the structure and dynamics of the nuclei of atoms, accounting for almost all of the visible matter in the universe. The future Electron-Ion Collider (EIC) will play a crucial role in discovering new laws of Nuclear physics. A pivotal aspect of the EIC is exceptional particle identification (PID). Identifying charged hadrons in their final state can be done with special types of Cherenkov Detectors. One type of detector utilizes the Detection of Internally Reflected Cherenkov radiation (DIRC) phenomena. Able to provide precise PID separation up to relatively high momenta, DIRC radiators, made of synthetic fused silica, produce Cherenkov radiation when hit by high energy electromagnetically charged particles. In this thesis we present details of the construction of a cosmic ray telescope (CRT) to utilize high energy muons from cosmic rays to test DIRC radiators. These types of radiators will be used for the high-performance DIRC (hpDIRC) to be used in the ePIC detector in the future EIC. We go into detail on the DIRC process and the individual pieces of hardware required to make the CRT. Lots of labor was used for certain parts of the CRT, specifically the construction of a dark box for the DIRC radiators. The CRT construction and implementation of all of its components are planned to be completed before 2025.

Shankman, Nathan↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Results from ADRIANO2 Test Beams

A novel high-granularity, dual-readout calorimetric technique (ADRIANO2) is under development as part of the research program of T1604 Collaboration. (Talk Presented at the 19th International Conference on Calorimetry in Particle Physics (CALOR 2022), University of Sussex, Sussex, UK, 16–20 May 2022). The building block of such a calorimeter consists of a pair of optically isolated, small size tiles made of scintillating plastic and lead glass. The prompt Čerenkov light from the glass can be exploited to perform high resolution timing measurements, while the high granularity provides good resolution of the spatial components of the shower. Dual-readout compensation and particle flow techniques can be applied simultaneously to the scintillation and to the Čerenkov section, providing excellent energy resolution as well as PID particle identification. These characteristics make ADRIANO2 a 6-D detector, suited for High Energy as well as High Intensity experiments. A report on the status of the ADRIANO2 project, preliminary measurements of light yield, and current and future R&D plans by T1604 Collaboration are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron/hadron separation with the TRD based on GaAs pixel detectors

Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.

GaAs detectors↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a Novel Platform for Characterizing Thermoelectric Materials for Uncooled Detectors for Land Imaging Applications

Thermal land imaging (imaging at ~8-14 micron optical wavelength) is an essential tool for understanding and managing terrestrial freshwater resources. Current thermal imaging instruments employ low temperature detectors, which require cryocoolers. Consequently, cost-saving reductions in size, weight, and power can be achieved by employing uncooled detectors. One uncooled detector concept, which NASA is pursuing, is a thermopile detector with sub-micron thick doped-Si thermoelectric materials. In order to characterize the thermoelectric properties of the doped silicon, we designed and optimized a novel apparatus. This simple apparatus measures the Seebeck coefficient with thermally isolated stages and LABVIEW automation. We optimized thermal stability using PID tuning and optimized the thermal contact between the thin film samples and stages using electrically conductive springs. Utilizing our apparatus, we measured the Seebeck coefficient of 0.45 micron thick phosphorus-doped single crystal Si samples bonded to alumina substrates. Using these Seebeck coefficient measurements and four-wire electrical resistivity measurements, we determined the relationship between the thermoelectric figure of merit and dopant concentration. These characterization results for doped-Si will guide our thermopile detector design to provide an optimal and competitive detector alternative for future thermal imaging instruments.

Reid, Riley A.↗

Performance of Muon Neutrino Reconstruction at ICARUS using SPINE Machine Learning.

ICARUS is a liquid argon time projection chamber (LArTPC) neutrino experiment at Fermilab. Located ~600 m from the Booster Neutrino Beam (BNB) target, it serves as the far detector in the Short-Baseline Neutrino (SBN) Program. The primary objective of the SBN Program is to probe neutrino oscillation physics at short baselines using multiple detectors, including measurements of both muon neutrino disappearance and electron neutrino appearance. A key requirement for the neutrino oscillation measurements is robust event reconstruction, including accurate and precise particle identification (PID) and kinematic reconstruction across a wide range of topologies. To achieve the required performance, we employ the SPINE (“Scalable Particle Imaging with Neural Embeddings”) package, a state-of-the-art machine learning reconstruction framework. This talk presents the status of muon neutrino reconstruction using SPINE at ICARUS, including the evaluation of reconstruction performance that will enable the full physics program at ICARUS and at the SBN Program.

Totani, Dante [Colorado State U.] (ORCID:000000019↗

Summer 2025 SULI: Nucleus ID, TinyTPC, and Scientific Communication

This paper summarizes my work during the Summer 2025 SULI internship, which focused on two main projects and broader scientific development. The first project involved improving the particle identification (PID) of protons, deuterons, and tritons using PIDA distributions and template fitting, with the goal of modeling nuclear final-state interactions (FSI) and testing the robustness of the method against systematic uncertainties. These techniques pave the way for future application to LArTPC data from the ICARUS detector. The second project centered on the optimization and data-taking of the TinyTPC detector, a compact LArTPC used for high-resolution low-energy measurements. I adjusted gain and threshold parameters, performed hardware validation tests, and developed analysis strategies to extract meaningful physics from collected data. Throughout the summer, I also enhanced my scientific communication and mentorship skills through presentations, collaborative analysis, and peer guidance.

McCright, Hannah [Maryland U.]↗

Modelling detector-specific reconstruction uncertainties in LAr-TPC

The Short-Baseline Neutrino (SBN) program features three Liquid Argon Time Projection Chamber (LAr-TPC) detectors positioned along the Booster Neutrino Beam (BNB) axis: the Short Baseline Neutrino Near Detector, MicroBooNE, and the ICARUS T600. As the largest operational LAr-TPC, ICARUS T600 serves as the far detector, located 600 m from the BNB target. While its primary goal is to record neutrino events, it also detects other ionizing events, including cosmic rays. This work focuses on analyzing and modeling detector-specific reconstruction uncertainties in LAr-TPC. These inefficiencies, identified during the Pattern Recognition phase handled by the PANDORA algorithm, impact subsequent Particle Fits and Offline Analysis. Specifically, inaccuracies in track reconstruction can lead to significant physical consequences, such as erroneous particle energy estimates and poor Particle Identification (PID), reducing the efficiency of neutrino event characterization. A key issue addressed is split tracks, caused by missing hits or incomplete track stitching by PANDORA. The aim of this internship is to characterize, model, and quantify the impact of split tracks on track reconstruction.

43 PARTICLE ACCELERATORS↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗