Radio frequency phototube

A method and apparatus of obtaining a record of repetitive optical or other phenomena having durations in the picosecond range, comprising a circular scan electron tube to receive light pulses and convert them to electron images consisting with fast nanosecond electronic signals, a continuous wave light or other particle pulses, e.g. electron picosecond pulses, and a synchronizing mechanism arranged to synchronize the deflection of the electron image (images) in the tube (tubes) with the repetition rate of the incident pulse train. There is also provided a method and apparatus for digitization of a repetitive and random optical waveform with a bandwidth higher than 10 GHz.

47 OTHER INSTRUMENTATION↗

The CLAS12 High Threshold Cherenkov Counter

The High Threshold Cherenkov Counter (HTCC) is one of the detector systems of the CLAS12 spectrometer, and is used to generate a fast trigger signal in electron scattering experiments in the polar angle range from 5°to 35°. The HTCC is installed in front of the drift chambers and introduces a minimal amount of additional material within the acceptance. The HTCC is one unit whose core component is a multifocal mirror that consists of 60 lightweight ellipsoidal mirrors. It is important that the HTCC provides efficient coverage of the CLAS12 forward acceptance with no gaps. In order to achieve this, each sector of the CLAS12 Forward Detector is covered by 2 identical half-sector mirrors that focus Cherenkov light on 8 phototubes. The HTCC has a total of 48 channels with Electron Tubes 9823QKB photomultipliers that have a 5-in quartz face plate to detect Cherenkov light. The system provides rejection of charged -mesons with momenta below 4.8 GeV for the reliable identification of scattered electrons. In this paper the details of the design, construction, calibration, and performance results of the HTCC are presented

Sharabian, Y. G.↗

Entopistic scintillators

Trajectories of cosmic rays through a balloon-borne experiment will be determined by pulse height analyzing the signals from each of the two or more phototubes coupled to each scintillator. Thin or tapered scintillators produce sufficiently strong gradients of phototube signal with respect to scintillation position that position uncertainties of about 1 cm can be achieved over 1-sq-m areas. Calculations and some test results for entopistic, or position determining, scintillators are presented.

Arens, J. F.↗

A radiation-hardened star scanner for spacecraft guidance and control

A star scanner for the Galileo Project is described. Because it must function in the intense Jupiter radiation field, which consists primarily of high-energy electrons and protons, this star scanner is designed with radiation-hardness as a prime objective. The optics and the multiplier phototube are specially designed to minimize fluorescence and Cerenkov effects, and the electronic components to minimize ionization and displacement damage. The star-scanner layout provides maximum shielding for the optics and phototube. Test results predict successful operation in the expected Jovian radiation environment.

Birnbaum, M. M.↗

An automated ozone photometer

A photometer capable of automatically measuring ozone concentration data to very high resolution during scientific research flights in the Earth's atmosphere was developed at NASA Ames Research Center. This instrument was recently deployed to study the ozone hole over Antarctica. Ozone is detected by absorbing 253.7-nm radiation from an ultraviolet lamp which shines through the sample of air and impinges on a vacuum phototube. A lower output from the phototube indicates more ozone present in the air sample. The photometer employs a CMOS Z80 microprocessor with an STD bus system for experiment control, data collection, and storage. Data are collected and stored in nonvolatile memory for experiments lasting up to 8 hr. Data are downloaded to a portable ground-support computer and processed after the aircraft lands. An independent single-board computer in the STD bus also calculates ozone concentration in real time with less resolution than the CMOS Z80 system, and sends this value to a cockpit meter to aid the pilot in navigation.

Lavelle, Joseph R.↗

An automated ozone photometer

A photometer capable of automatically measuring ozone concentration data to very high resolution during scientific research flights in the earth's atmosphere was developed at the NASA Ames Research Center. This instrument was recently deployed to study the ozone hole over Antarctica. Ozone is detected by absorbing 253.7-nm radiation from an ultraviolet lamp which shines through the sample of air and impinges on a vacuum phototube. A lower output from the phototube indicates more ozone present in the air sample. The photometer employs a CMOS 280 control, data collection, and storage.

Lavelle, Joseph R.↗

Steady-State Vacuum Ultraviolet Exposure Facility With Automated Lamp Calibration and Sample Positioning Fabricated

The Next Generation Space Telescope (NGST) will be placed in an orbit that will subject it to constant solar radiation during its planned 10-year mission. A sunshield will be necessary to passively cool the telescope, protecting it from the Sun s energy and assuring proper operating temperatures for the telescope s instruments. This sunshield will be composed of metalized polymer multilayer insulation with an outer polymer membrane (12 to 25 mm in thickness) that will be metalized on the back to assure maximum reflectance of sunlight. The sunshield must maintain mechanical integrity and optical properties for the full 10 years. This durability requirement is most challenging for the outermost, constantly solar-facing polymer membrane of the sunshield. One of the potential threats to the membrane material s durability is from vacuum ultraviolet (VUV) radiation in wavelengths below 200 nm. Such radiation can be absorbed in the bulk of these thin polymer membrane materials and degrade the polymer s optical and mechanical properties. So that a suitable membrane material can be selected that demonstrates durability to solar VUV radiation, ground-based testing of candidate materials must be conducted to simulate the total 10- year VUV exposure expected during the Next Generation Space Telescope mission. The Steady State Vacuum Ultraviolet exposure facility was designed and fabricated at the NASA Glenn Research Center at Lewis Field to provide unattended 24-hr exposure of candidate materials to VUV radiation of 3 to 5 times the Sun s intensity in the wavelength range of 115 to 200 nm. The facility s chamber, which maintains a pressure of approximately 5 10(exp -6) torr, is divided into three individual exposure cells, each with a separate VUV source and sample-positioning mechanism. The three test cells are separated by a water-cooled copper shield plate assembly to minimize thermal effects from adjacent test cells. Part of the interior sample positioning mechanism of one test cell is shown in the illustration. Of primary concern in VUV exposure is the maintenance of constant measured radiation intensity so that the sample s total exposure can be determined in equivalent Sun hours. This is complicated by the fact that a VUV lamp s intensity degrades over time, necessitating a decrease in the distance between the test samples and the lamp. The facility overcomes this challenge by periodically measuring the lamp s intensity with a cesium-iodide phototube and adjusting the sample distance as required to maintain constant exposure intensity. Sample positioning and periodic phototube location under the lamp are both achieved by a single lead-screw assembly. The lamps can be isolated from the main vacuum chamber for cleaning or replacement so that samples are not exposed to the atmosphere during a test.

Sechkar, Edward A.↗

Photomultiplier Tubes: Calibration and Neutrino Physics

Photomultiplier Tubes are devices designed to amplify very small light signals, on the order of single photons, to levels that are detectable by conventional electronics. Such a high level of amplification, however, comes with a quite a few potential problems, as the relationship between a light signal in and the current out- the response of the system- can be difficult to determine, meaning that photomultiplier tubes' use in scientific research requires a great deal of sensitive calibration. Once calibrated, the photomultiplier tube is a tool that can be used on a number of interesting problems, including the field of neutrino physics. This work deals with the use of photomultiplier tubes' use in the upcoming Double Chooz experiment to determine the mixing angle theta{sub 13}, between different neutrino mass eigenstates. Calibration of the tubes requires measurement of the charge characteristics, most notably, the gain, pedestal, and the dark rate of a tube. Moreover, for all modern tubes, there is an additional feature which can be used to calibrate the system, the single photo electron peak, which describes the response of the tube to a single photon. Some theories predict higher order effects, in addition to the single photoelectron peak, including things like incomplete multiplication of a single photon electron, features which are theoretically able to be determined by a detailed examination of the single photoelectron peak. This paper goes through the methods of calibrating a phototubes both with and without a single photoelectron peak, and is unable to determine conclusively whether or not partial multiplication is able to explain certain features of photomultiplier tubes with a single photoelectron peak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

Neutrino mass hierarchy extraction using atmospheric neutrinos in ice

We show that the measurements of 10 GeV atmospheric neutrinos by an upcoming array of densely-packed phototubes buried deep inside the IceCube detector at the South Pole can be used to determine the neutrino mass hierarchy for values of sin{sup 2}2{theta}{sub 13} close to the present bound, if the hierarchy is normal. These results are obtained for an exposure of 100 Mton years and systematic uncertainties up to 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗