Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PHOTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characteristics of CMEs observed in the heliosphere using Helios photometer data

The zodiacal light photometers on the two Helios spacecraft have been used to detect and study mass ejections and other phenomena emanating from the sun and traversing the heliosphere within 1 AU. We have recently compiled a complete list of all of the significant white light transient events detected from the 90-deg photometers on both Helios spacecraft. This is a preliminary report on the long-term frequency of occurrence of these events; it emphasizes newly processed data from Helios-l from 1975 through 1982 and viewed south of the ecliptic. With the large Helios photometer data base, we will be able to identify the fraction of the 90 deg events which are heliospheric CMEs and determine their characteristics.

Webb, D. F.

Stellar Calibration of the WIC and SI Imagers and the GEO Photometers on IMAGE/FUV

The FUV instrument on the IMAGE spacecraft comprises three wide-field imagers, the Wide-Band Imaging Camera (WIC) of observing N2 Lyman-Birge-Hopfield (LBH) (140-190 nm) emissions and the Spectrographic Imager (SI), which has a 121.8 nm channel for observing red-shifted HI Lya photons and a 135.6 run channel for observing 01 135.6 nm emissions. In addition, three HI Lya photometers (GEO) are used to monitor the geocorona. The fields of view are 17 degrees x 17 degrees for the WIC imagers, 15 degrees x 15 degrees for the two SI imagers, and 10 diameter for the three GEO photometers. As the IMAGE spacecraft spins every 120 seconds, the GEO photometers sweep out circles on the sky (at 0 degrees and plus or minus 30 degrees with respect to the spacecraft spin plane), and the WIC and SI imagers use the Time Delay Integration (TDI) method to construct images centered on the Earth. Many FUV-bright stars are seen in the WIC, SI and even the GEO data. WE have used archived International Ultraviolet Explorer (IUE) far-ultraviolet flux spectra for 22 of the brightest of these stars to help refine the FUV instrumental sensitivities. The stars chosen range in spectral type form B0V to A11V, with magnitudes ranging from V- 1.3 (a Cru) to V=4.7 (G Cen) (although many more fainter stars are also seen). The initial results of this stellar calibration will be presented and compared with the pre-flight and dayglow modeling results.

Gladstone, R.

A Tracking Sun Photometer Without Moving Parts

This innovation is small, lightweight, and consumes very little electricity as it measures the solar energy attenuated by gases and aerosol particles in the atmosphere. A Sun photometer is commonly used on the Earth's surface, as well as on aircraft, to determine the solar energy attenuated by aerosol particles in the atmosphere and their distribution of sizes. This information is used to determine the spatial and temporal distribution of gases and aerosols in the atmosphere, as well as their distribution sizes. The design for this Sun photometer uses a combination of unique optics and a charge coupled device (CCD) array to eliminate moving parts and make the instrument more reliable. It could be selfcalibrating throughout the year. Data products would be down-welling flux, the direct-diffuse flux ratio, column abundance of gas phase constituents, aerosol optical depth at multiple-wavelengths, phase functions, cloud statistics, and an estimate of the representative size of atmospheric particles. These measurements can be used to obtain an estimate of aerosol size distribution, refractive index, and particle shape. Incident light is received at a light-reflecting (inner) surface, which is a truncated paraboloid. Light arriving from a hemispheric field of view (solid angle 2 steradians) enters the reflecting optic at an entrance aperture at, or adjacent to, the focus of the paraboloid, and is captured by the optic. Most of this light is reflected from an inner surface. The light proceeds substantially parallel to the paraboloid axis, and is detected by an array detector located near an exit aperture. Each of the entrance and exit apertures is formed by the intersection of the paraboloid with a plane substantially perpendicular to the paraboloid axis. Incident (non-reflected) light from a source of limited extent (the Sun) illuminates a limited area on the detector array. Both direct and diffuse illumination may be reflected, or not reflected, before being received on the detector array. As the Sun traverses a path in the sky over some time interval, the track of the Sun can be traced on the detector array. A suitably modified Sun photometer might be used to study the dynamics of an environment on another planet or satellite with an atmosphere.

Strawa, Anthony W.

The Little Photometer That Could: Technical Challenges and Science Results from the Kepler Mission

The Kepler spacecraft launched on March 7, 2009, initiating NASA's first search for Earth-size planets orbiting Sun-like stars. Since launch, Kepler has announced the discovery of 17 exoplanets, including a system of six transiting a Sun-like star, Kepler-11, and the first confirmed rocky planet, Kepler-10b, with a radius of 1.4 that of Earth. Kepler is proving to be a cornucopia of discoveries: it has identified over 1200 candidate planets based on the first 120 days of observations, including 54 that are in or near the habitable zone of their stars, and 68 that are 1.2 Earth radii or smaller. An astounding 408 of these planetary candidates are found in 170 multiple systems, demonstrating the compactness and flatness of planetary systems composed of small planets. Never before has there been a photometer capable of reaching a precision near 20 ppm in 6.5 hours and capable of conducting nearly continuous and uninterrupted observations for months to years. In addition to exoplanets, Kepler is providing a wealth of astrophysics, and is revolutionizing the field of asteroseismology. Designing and building the Kepler photometer and the software systems that process and analyze the resulting data to make the discoveries presented a daunting set of challenges, including how to manage the large data volume. The challenges continue into flight operations, as the photometer is sensitive to its thermal environment, complicating the task of detecting 84 ppm drops in brightness corresponding to Earth-size planets transiting Sun-like stars.

Kepler Mission

Scanning photometer system automatically determines atmospheric layer height

Two photometers, placed a given distance apart, determine the height of nonuniform luminous layers in a synchronous manner. Photometer outputs are correlated by a simple analog correlation computer to automatically give the luminous layer height. This system is used to determine visibility ceilings at airports.

Wolff, M.

Photometer for detection of sodium day airglow.

Description of a photometer for daytime ground-based measurements of sodium airglow emission. The photometer described can be characterized by the following principal features: (1) a narrow (4.5-A) interference filter for initial discrimination; (2) cooled photomultiplier detector to reduce noise from dark current fluctuations and chopping to eliminate the average dark current; (3) a sodium vapor resonance cell to provide an effective bandpass comparable to the Doppler line width; (4) separate detection of all light transmitted by the interference filter to evaluate the Rayleigh and Mie components within the Doppler width of the resonance cell; and (5) temperature quenching of the resonance cell to evaluate and account for instrumental imperfections.

Mcmahon, D. J.

Simple photometer circuits using modular electronic components

Operational and peak holding amplifiers are discussed as useful circuits for bioluminescence assays. Circuit diagrams are provided. While analog methods can give a good integration on short time scales, digital methods were found best for long term integration in bioluminescence assays. Power supplies, a general photometer circuit with ratio capability, and variations in the basic photometer design are also considered.

Wampler, J. E.

Gas absorption cell photometer for rocket observations of local interstellar helium

A photometer sensitive in the 584-A line of He I, incorporating a helium-gas absorption cell, has been developed. The helium is confined at a pressure of 0.2 torr between thin-metal-foil broad-band ultraviolet filters. The cell contains sufficient helium to absorb 584-A radiation scattered from atmospheric helium. The ratio of fluxes seen with the cell full and empty provides a valuable datum for fitting models of the local interstellar medium, which is independent of solar 584-A flux, interstellar helium density, and photometer sensitivity.-

Freeman, J.

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.

Photometer used for response time measurement

Photometer detects motion for measuring response speed and acceleration of servocontrol system. Instrument senses selected output movement shortly after operator activates hand-controlled input. Time delay is measured on X/T recorder and response calculated. With suitable motion targets, photometer measures any open- or closed-loop servoresponse and servorate or computer lag without system disturbance.

Da Silva, A. J.

Ultraviolet photometer observations of the Saturnian system

Several interesting cloud and atmospheric features of the Saturn system have been observed by the long-wavelength channel of the two-channel ultraviolet photometer aboard the Pioneer Saturn spacecraft. Reported are observations of the most obvious features, including a Titan-associated cloud, a ring cloud, and the variation of atmospheric emission across Saturn's disk. The long-wavelength data for Titan suggest that a cloud of atomic hydrogen extends at least 5 Saturn radii along its orbit and about 1.5 Saturn radii vertically. A ring cloud, thought to be atomic hydrogen, has also been observed by the long-wavelength channel of the photometer; it shows significant enhancement in the vicinity of the B ring. Finally, spatially resolved observations of Saturn's disk show significant latitudinal variation. Possible explanations of the variation include aurora or limb brightening.

Judge, D. L.

An f/35 submillimeter photometer for the NASA infrared telescope facility

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Whitcomb, S. E.

Pioneer 10 ultraviolet photometer observations of the interplanetary glow at heliocentric distances from 2 to 14 AU

An analysis is presented of the observed Pioneer 10 interplanetary data from 1972 to 1977, taking into account the interplanetary glow intensity observed by the Pioneer 10 UV photometer at sun-spacecraft distances of 2-14 AU. On the basis of the obtained data, it was determined that the background intensity for the 200-1400 A band pass of the photometer channel is about 40 + or - 10 R, and that the nearby interstellar density is 0.04 + or - 0.91 per ccm for hydrogen and about 0.01 + or - 0.002 per ccm for helium. Accordingly, the He/H number density is about 0.25 at large distances from the sun. The Pioneer 10 spacecraft is leaving the solar system in the downwind direction, while both Pioneer 11 and Voyager will leave in the upwind direction. The combined UV observations of the interplanetary glow will provide accurate results on the physical status of the inflowing interstellar gas and the variability of background radiation as well.

Wu, F. M.

A preliminary assessment of the problems in the use of interference filter photometers to determine total ozone

In the spring of 1979 an investigation was started involving the intercomparison of five ground based instruments designed to measure total ozone. The instruments considered include the Dobson spectrometer, the Russian M-83 ozonometer, the Brewer Ozone Spectrophotometer, the New Zealand (Canterbury) filter photometer, and the SenTran Company filter photometer. Three of these instruments use optical filters to make spectrophotometric determinations of total atmospheric ozone. The M-83 uses glass absorption filters to isolate the ultraviolet bands used. The Canterbury and the SenTran instruments use narrow-bandpass dielectric interference filters for the same purpose. Instruments employing optical filters are very appealing since they can be made small, rugged, and relatively inexpensive. However, the results of the reported investigation show that serious problems must be resolved before any filter instrument can be considered reliable enough for the conduction of long term, meaningful ozone measurements.

Gerlach, J. C.

A portable telescope, photometer, and data-recording system

A description is presented of a portable telescope, two-channel photometer and high-speed data-recording system that meet the unique requirements of occultation astronomy. The instrumentation has been designed for portability, high time resolution, accurate absolute timing, and ease of use. The instrumentation includes a light-weight 35.5-cm (14-inch) objective portable telescope, a two-channel high-speed photometer and a data-recording system built into a suitcase. The equipment has been successfully used in field operations and at fixed observatories in India, Australia, and Hawaii.

Baron, R. L.

A high-speed, dual-CCD imaging photometer

The SNAPSHOT is a high-speed, dual-CCD imaging photometer, with special capability for occultation observations. It is capable of recording occultation light curves in the presence of bright, nonuniform background illumination, such as occultations of stars by Saturn's rings or by comets. Such events are difficult or impossible to observe with conventional photometers. The fundamental idea that makes high time-resolution observations possible is to reduce the data rate by digitizing only those pixels in subframes containing the objects of interest.

Dunham, E. W.

Polarization photometer to measure bidirectional reflectance factor R(55 deg, 0 deg, 55 deg, 180 deg) of leaves

A polarization photometer has been developed for rapidly determining the bidirectional, polarized, and diffuse light-scattering properties of individual leavs illuminated and measured 'in vivo' at an angle of 55 deg (approximately Brewster's angle) in six wavelength bands in the visible and near-IR wavelength regions. The optical performance and data quality of the system are evaluated to estimate the magnitude of the variation in the data attributable to the instrument system and to measurement procedures. The potential to discriminate between three species of oak is demonstrated using data acquired by the polarization photometer. The instrument is being used to increase understanding of the radiation transfer process in plant canopies and specifically to determine how agronomic information of the physical and chemical processes in leaves, plants, and plant canopies is expressed in these light-scattering properties.

Vanderbilt, V. C.