Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PHOTOGRAPHIC FILM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Automatic marker for photographic film

Commercially-produced wire-marking machine is modified to title or mark film rolls automatically. Machine is used with film drive mechanism which is powered with variable-speed, 28-volt dc motor. Up to 40 frames per minute can be marked, reducing time and cost of process.

Gabbard, N. M.

Photographic film image enhancement

A series of experiments were undertaken to assess the feasibility of defogging color film by the techniques of optical spatial filtering. A coherent optical processor was built using red, blue, and green laser light input and specially designed Fourier transformation lenses. An array of spatial filters was fabricated on black and white emulsion slides using the coherent optical processor. The technique was first applied to laboratory white light fogged film, and the results were successful. However, when the same technique was applied to some original Apollo X radiation fogged color negatives, the results showed no similar restoration. Examples of each experiment are presented and possible reasons for the lack of restoration in the Apollo films are discussed.

Horner, J. L.

Photographic film and the Skylab environment

An overview is presented of an investigation which was conducted to determine the actual effects of the Skylab environment on flight films. Examples of the flight film performance data are provided. Attention is given to the Skylab film, the environmental parameters, a major events profile of the Skylab mission, and a film environmental effects analysis. Representative Skylab film environmental response data are shown in a graph.

Oldham, L. P.

Preserving Color in Developed Photographic Film

Controlled-atmosphere vault retards fading and deterioration of developed high speed film. Vault with externally controlled valve regulates flow of nitrogen gas from internally mounted tank. Gas purges ambient air from vault through purge valve and maintains vault pressure slightly above ambient.

Hoover, R. B.

Effects of shuttle bay environment on UV sensitive photographic film results of measurements aboard STS-7 and STS-8

Schumann emulsions, having low gelatin content and no protective gelatin overcoating, are extremely sensitive to environmental conditions and handling. Experiments using this emulsion are to be flown on the space shuttle within the cargo-bay. Because the environment of the cargo-bay is unknown, a Get-Away-Special payload was designed to expose Kodak-type SO 652 Schumann emulsion to the residual atmosphere of the cargo-bay. The experiment was programmed to make exposures for various time periods to determine the maximum length of time the film could be exposed in making a measurement and what precautions would be required to preserve the film during ascent into orbit and reentry. The results of the STS-7 and STS-8 flights indicated that long exposures in the shuttle bay do not produce high fog levels in orbit. Observations of severe bleaching of the latent image makes protection of the emulsion during reentry manditory and increase of fog levels with time set a limit of four weeks (preferably less than three) between installation and recovery of the emulsion for processing.

Kreplin, R. W.

Effects of Shuttle bay environment on UV sensitive photographic film - Instrumentation for Get-Away-Special

An account is given of a Get-Away-Special experiment flown on Space Shuttles 7 and 8 investigating the effect of the space environment on Shumann emulsions. Shumann emulsions, having low gelatin content and no protective gelatin overcoating, are useful detectors of ultraviolet radiation shorter than 2200 angstroms but are extremely sensitive to environmental conditions and handling. The instrument required no interface with the Shuttle. It was turned on by an aneroid switch at an altitude of 50,000 feet. After that, its operation was controlled completely by a CMOS digital controller. Each hour, two temperatures and one voltage were read and stored in a CMOS programmable read only memory. At intervals, valves were opened and closed to expose SO 652 film strips of three sensitivities to the cargo bay environment for various time periods. The design and operation of the instrument package is described.

Kreplin, R. W.

Photographic film as a detector for solar X-ray/XUV astronomical applications

The characteristics of several films as detectors for solar soft X-ray (3-100 A) and XUV (100-600 A) radiation are discussed. The properties of soft-X-ray-sensitive films like the SO-212 make them useful for the glancing-incidence X-ray telescopes. Used for the MSFC X-Ray Telescope during the Skylab mission (at the wavelengths of 8.34 and 15.4 A), the SO-212 film functioned as a photon detector, achieving spatial resolution of 2.2 arc sec. Other high-resolution soft-X-ray-sensitive films include SO-242 and 101-07. For XUV detection, the SC-5, SC-7, 104-07, and 101-07 films are recommended.

Hoover, Richard B.

The calibration of photographic and spectroscopic films. A densitometric analysis of IIaO film flown aboard the space shuttle transportation system STS3, STS8, and STS7

The results of these studies have implications for the utilization of the IIaO spectroscopic film on the future shuttle and space lab missions. These responses to standard photonic energy sources will have immediate application for the uneven responses of the film photographing a star field in a terrestrial or extraterrestrial environment with associated digital imaging equipment.

Hammond, Ernest C., Jr.

Optical noise suppression device and method

A device and method is disclosed for suppression of optical noise in an optical spatial filtering system using highly coherent light. In the disclosed embodiment, input photographic film to be processed in the system, and output photographic film to be exposed, are each mounted on lateral translation devices. During application of the coherent light for exposure of the output film, the two translation devices are moved in synchronism by a motor-driven gear and linkage assembly. The ratio of the resulting output film translation to the input film translation is equal to the magnification of the optical data processing system. The noise pattern associated with the lenses and other elements in the optical processing system remains stationary while the image-producing light moves laterally through the pattern with the output film, thus averaging out the noise effect at the output film.

Horner, J. L.

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION

The Nagoya cosmic-ray muon spectrometer 3, part 4: Track reconstruction method

One of the greatest problems in measuring particle trajectories with an optical or visual detector system, is the reconstruction of trajectories in real space from their recorded images. In the Nagoya cosmic-ray muon spectrometer, muon tracks are detected by wide gap spark chambers and their images are recorded on the photographic film through an optical system of 10 mirrors and two cameras. For the spatial reconstruction, 42 parameters of the optical system should be known to determine the configuration of this system. It is almost impossible to measure this many parameters directly with usual techniques. In order to solve this problem, the inverse transformation method was applied. In this method, all the optical parameters are determined from the locations of fiducial marks in real space and the locations of their images on the photographic film by the non-linear least square fitting.

Shibata, S.

A concept for magazine Bimat processor

Concept utilizes existing film magazines to process photographic film as the film is exposed. A standard magazine can be converted to a Bimat processor by adding three stainless steel rollers. All chemicals required for processing and fixing the negative are contained in the Bimat film.

Park, C. E.