Limiting noise fraction in PDV measurements

The limiting frequency resolution of a PDV measurement is: σf = $\sqrt\frac{6 η}{fsτ^3π}$ where f s is the sample rate, τ is the analysis time duration, and 11 is the noise fraction. Although T is a strong lever for reducing uncertainty, this parameter must be kept small to preserve time resolution. Consider a PDV measurement with sampled at 80 GS/s and analyzed in 1 ns durations. A 1% noise fraction corresponds to 0.87 MHz of frequency uncertainty, which at 1550 nm works out to 0.68 m/s. A 10% noise fraction has a limiting velocity resolution of about 7 m/s; for comparison, a VISAR system with similar response time (0.5 ns delay, 532 m/s fringe constant) would have a limiting uncertainty of 5-6 m/s. Noise fractions of 10-20% or less are desirable for measurements at this time scale.

42 ENGINEERING↗

Brief History and Summary of the PDV [Slides]

The early development of the PDV was not a straightforward process. There were many fortuitous events that occurred over several years to make it happen. The drive toward more PDV channels per digitizer was initially driven by the high cost of the digitizer. The optical pin dome diagnostic for the national labs was the driver for very large channel count.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous mapping of the unsteady flow fields by Particle Displacement Velocimetry (PDV)

Current experimental and computational techniques must be improved in order to advance the prediction capability of the longitudinal vortical flows shed by underwater vehicles. The generation, development, and breakdown mechanisms of the shed vortices at high Reynolds numbers are not fully understood. The ability to measure hull separated vortices associated with vehicle maneuvering does not exist at present. The existing point-by-point measurement techniques can only capture approximately the large 'mean' eddies but fail to meet the dynamics of small vortices during the initial stage of generation. A new technique, which offers a previously unavailable capability to measure the unsteady cross-flow distribution in the plane of the laser light sheet, is called Particle Displacement Velocimetry (PDV). PDV consists of illuminating a thin section of the flowfield with a pulsed laser. The water is seeded with microscopic, neutrally buoyant particles containing imbedded fluorescing dye which responds with intense spontaneous fluorescence with the illuminated section. The seeded particles in the vortical flow structure shed by the underwater vehicle are illuminated by the pulse laser and the corresponding particle traces are recorded in a single photographic frame. Two distinct approaches were utilized for determining the velocity distribution from the particle traces. The first method is based on matching the traces of the same particle and measuring the distance between them. The direction of the flow can be identified by keeping one of the pulses longer than the other. The second method is based on selecting a small window within the image and finding the mean shift of all the particles within that region. The computation of the auto-correlation of the intensity distribution within the selected sample window is used to determine the mean displacement of particles. The direction of the flow is identified by varying the intensity of the laser light between pulses. Considerable computational resources are required to compute the auto-correction of the intensity distribution. Parallel processing will be employed to speed up the data reduction. A few examples of measured unsteady vortical flow structures shed by the underwater vehicles will be presented.

Huang, Thomas T.↗

PDV modifications.

External modifications can transform a conventional photonic doppler velocimetry (PDV) system to other useful configurations - Non-standard probes and Frequency-conversion measurements. This approach is easier than supporting every conceivable measurement in the core PDV design. Circulator specifications may be important - -30 dB isolation (common) probably not be enough, -50 dB isolation is available, and some bench testing may be needed.

99 GENERAL AND MISCELLANEOUS↗

Fourier analysis by spectral transformation (Fast) Photonic Doppler Velocimetry (PDV) with signal fade mitigation

A state-of-the-art class of photonic Doppler velocimetry (PDV) diagnostic and novel methods to stabilize any class of PDV signal has been developed. The former brings velocimetry to new extremes in maximum velocity and fast time resolution, while maintaining precision velocity resolution, long record length capability, and the ability to record multiple velocities simultaneously. The latter compensates for large changes in signal intensity common in many experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PDV Sensitivity [Slides]

The concept of PDV sensitive is not new. But we tend not to discuss sensitivity in a rigorous, quantified way. That should change. Indeed there is a natural definition, which is just the energy of light from the target within the analysis window that gives a SNR of 10 in the frequency domain. Systems designers, diagnostic engineers, and operators should use the language of sensitivity: (1) Absolute sensitivity: nW * ns; (2) Launch power: mW or dBm; (3) Relative surface return: dB; (4) Relative sensitivity: dB * ns. This will help us design better systems, choose the correct system for the job, maintain our systems, and tune our systems.

47 OTHER INSTRUMENTATION↗

PDV Uncertainty Estimation & Methods Comparison

Several methods are presented for estimating the rapidly changing instantaneous frequency of a time varying signal that is contaminated by measurement noise. Useful a posteriori error estimates for several methods are verified numerically through Monte Carlo simulation. However, given the sampling rates of modern digitizers, sub-nanosecond variations in velocity are shown to be reliably measurable in most (but not all) cases. Results support the hypothesis that in many PDV regimes of interest, sub-nanosecond resolution can be achieved.

47 OTHER INSTRUMENTATION↗

New Concepts for Improving Dynamic Range in (M)PDV Systems

Presentation provides overview of new concepts for improving dynamic range in (M)PDV systems by modulating launch power and dynamically refocusing probe optics, which could improve collection over a wider range of probe-surface distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IER268 PDV Measurements

PowerPoint slides providing a quick-look of photon Doppler velocimetry (PDV) data taken during a series bursts using the Godiva machine located at the NNSS Device Assembly Facility. Vibrations, or ringing, of approximately 7.2 to 7.8 kHz were observed.

47 OTHER INSTRUMENTATION↗

Modular Optical PDV System

A modular optical photon Doppler velocimetry (PDV) detector system has been developed by using readily available optical components with a 20-GHz Miteq optical detector into eight channels of single-wide modules integrated into a 3U rack unit (1U = 1.75 inches) with a common power supply. Optical fibers were precisely trimmed, welded, and timed within each unit. This system has been used to collect dynamic velocity data on various physics experiments. An optical power meter displays the laser input power to the module and optical power at the detector. An adjustable micro-electromechanical system (MEMS) optical attenuator is used to adjust the amount of unshifted light entering the detector. Front panel LEDs show the presence of power to the module. A fully loaded chassis with eight channels consumes 45 watts of power. Each chassis requires 1U spacing above and below for heat management. Modules can be easily replaced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and Design of a Sub-Nyquist PDV Digitization System

Photon-Doppler Velocimetry (PDV) uses interferometry of a transmitted optical signal reflected from a fast-moving device under test (DUT) to generate a product signal at a doppler shifted frequency which is proportional to the velocity of the object being measured. The technique has applications in shock physics, where it is used to measure fast-moving objects over a short lifespan of travel, such as a bullet, shrapnel, or other shock accelerated object.

42 ENGINEERING↗

PDV Methods and Analysis for Surveillance of Explosive Components

The Weapons Evaluation Test Laboratory (WETL) at Sandia is collaborating with Lawrence Livermore National Laboratory (LLNL) to enhance explosive surveillance testing by integrating Photon Doppler Velocimetry (PDV) data. This project has streamlined the testing environment, reducing hardware costs and training needs while improving data collection efficiency and usability for lab technicians.

Kress, Matthew Kip [Sandia National Laboratories (↗

Detonation wave profiles measured in plastic bonded explosives using 1550 nm photon doppler velocimetry (PDV)

We present detonation wave profiles measured in two TATB based explosives and two HMX based explosives. Profiles were measured at the interface of the explosive and a Lithium-Fluoride (LiF) window using 1550 nm Photon Doppler Velocimetry (PDV). Planar detonations were produced by impacting the explosive with a projectile launched in a gas-gun. The impact state was varied to produce varied distance to detonation, and therefore varied support of the Taylor wave following the Chapman-Jouget (CJ) or sonic state. Profiles from experiments with different support should be the same between the Von-Neumann (VN) spike and CJ state and different thereafter. Comparison of profiles with differing support, therefore, allows us to estimate reaction zone lengths. For the TATB based explosive, a reaction zone length of {approx} 3.9 mm, 500 ns was measured in EDC-35, and a reaction zone length of {approx} 6.3 mm, 800 ns was measured in PBX 9502 pre-cooled to -55 C. The respective VN spike state was 2.25 {+-} 0.05 km/s in EDC-35 and 2.4 {+-} 0.1 km/s in the cooled PBX 9502. We do not believe we have resolved either the VN spike state (> 2.6 km/s) nor the reaction zone length (<< 50 ns) in the HMX based explosives.

36 MATERIALS SCIENCE↗