Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Passive Accelerometer System Measurements on MIR

The Passive Accelerometer System (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The acceleration is measured by recording the average velocity of the spherical ball over a suitable time increment. A modified form of Stokes law is used to convert the average velocity into an acceleration. PAS was used to measure acceleration on the MIR space station and on the first United States Microgravity Laboratory (USML-1). The PAS measurement on MIR revealed remarkably low acceleration levels in the SPEKTR module.

Alexander, J. Iwan D.↗

Calculation of Free-Free Opacities

Free-free absorption is an important contribution to the opacity for radiation transport through hot materials Temperatures can be as high as several keV, such that it becomes a computational challenge to solve the Schrodinger equation efficiently for rapidly oscillating continuum functions for high angular momenta. Several groups\footnots, including ours, have studied the phase amplitude solution (PAS) of the Schrodinger equation, in which one solves equations for the wave function amplitude and phase, which are: smooth functions of the electron energy. It is also important to have an accurate Schroudinger benchmark for the development of the PAS method. We present results for dipole matrix elements, Gaunt factors, and cross sections for the absorption of radiation at various energies for Cs XIX at temperature=100 eV and density=0.187 g/cc for our newly developed PAS and Schrodinger benchmark.

Bhatia, A. K.↗

Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers

The design, simulation, and characterization of a novel Ka-band (32.05 0.25 GHz) rectangular waveguide two-way branch-line hybrid unequal power combiner (with port impedances matched to that of a standard WR-28 waveguide) has been created to combine input signals, which are in phase and with an amplitude ratio of two. The measured return loss and isolation of the branch-line hybrid are better than 22 and 27 dB, respectively. The measured combining efficiency is 92.9 percent at the center frequency of 32.05 GHz. This circuit is efficacious in combining the unequal output power from two Ka-band GaAs pseudomorphic high electron mobility transistor (pHEMT) monolithic microwave integrated circuit (MMIC) power amplifiers (PAs) with high efficiency. The component parts include the branch-line hybrid-based power combiner and the MMIC-based PAs. A two-way branch-line hybrid is a four-port device with all ports matched; power entering port 1 is divided in phase, and into the ratio 2:1 between ports 3 and 4. No power is coupled to port 2. MMICs are a type of integrated circuit fabricated on GaAs that operates at microwave frequencies, and performs the function of signal amplification. The power combiner is designed to operate over the frequency band of 31.8 to 32.3 GHz, which is NASA's deep space frequency band. The power combiner would have an output return loss better than 20 dB. Isolation between the output port and the isolated port is greater than 25 dB. Isolation between the two input ports is greater than 25 dB. The combining efficiency would be greater than 90 percent when the ratio of the two input power levels is two. The power combiner is machined from aluminum with E-plane split-block arrangement, and has excellent reliability. The flexibility of this design allows the combiner to be customized for combining the power from MMIC PAs with an arbitrary power output ratio. In addition, it allows combining a low-power GaAs MMIC with a high-power GaN MMIC. The arbitrary port impedance allows matching the output impedance of the MMIC PA directly to the waveguide impedance without transitioning first into a transmission line with characteristic impedance of 50 ohms. Thus, by eliminating the losses associated with a transition, the overall SSPA efficiency is enhanced. For reducing the cost and weight when required in very large quantities, such as in the beam-forming networks of phased-array antenna systems, the combiner can be manufactured using metal-plated plastic. Two hybrid unequal power combiners can be cascaded to realize a non-binary combiner (for e.g., a three-way) and can be synergistically optimized for low VSWR (voltage standing wave ratio), low insertion loss, high isolation, and wide bandwidth using commercial off-the-shelf electromagnetic software design tools.

Simons, Rainee N.↗

Biocybernetic Closed-Loop System for Mitigating Hazardous States of Awareness

The past century of passenger flight has seen continuous improvement in aviation safety by the aerospace industry. However, while commercial aviation accident rates have continued to decline, human error-related incident and accident rates remain remarkably constant across all types of aviation (Shappell, et al., 2007). Unfortunately, this level of human error is unacceptable when considering projections for increased traffic volume (FAA, 2009), and is likely to yield more incidents and accidents unless a more complete understanding of operator error is achieved and remediations are implemented. One area of interest highlighted by researchers is Hazardous States of Awareness (HSAs) that can result from deficiencies in the design and inappropriate use of human-machine interfaces. Identifying and mitigating HSAs is critical for reducing operator errors. One promising approach uses psychophysiological measures which enable automated systems to adapt to the operator?s state and modify modes of operation to support optimal human performance (Scerbo, 2007). This paper will survey previous research and describe future directions for the application of psychophysiological measures of operators derived from cortical and autonomic assessment to perform real-time adaptive modulation of human-automation task mode mixes. The authors will present a summary of previous work done at NASA LaRC and Old Dominion University using a Psychophysiologically Adaptive System (PAS) in which the level of automation of the NASA Multi-Attribute Task Battery was modulated based on Engagement Indices derived from the users? electroencephalogram (Pope, Bogart, & Bartolome, 1995; for review see, Scerbo, Freeman, & Mikulka, 2003). Future theoretical and methodological directions for this type of closed-loop research will be discussed. Specifically, the capacity for this type of PAS to maintain effective operator state and to enable validation of candidate physiological indices will be described. Consideration will also be given to critical system characteristics (e.g., engagement indices, methods for invoking changes among system states, individual differences among users, etc.) that have been or still need to be studied. The potential of the PAS approach for interactive system design and prototyping will also be described. Examples of adaptive automation flight deck concepts in recent experiments will be highlighted and discussed.

Chad L Stephens↗

NASA study of an automated Pilot Advisory System

A Pilot Advisory System (PAS) concept for high-density uncontrolled airports is discussed where the general aviation pilots will be provided with automatic audio voice airport and air traffic advisories within two minute intervals and with mid-air collision warnings whenever such situations arise. Free of manual inputs, the PAS includes the options of fixed-base operator runway select, automatic restart and self-test, and remote inquiry of system status and messages.

Parker, L. C.↗

PMR polyimides from solutions containing mixed endcaps

Previous studies have shown that partial substitution of p-aminostyrene (PAS) for the monomethylester of endo-5-norbornene-2, 3-dicarboxylic acid (NE) lowered the cure temperature of PMR polyimides from 316 to 260 C, but the modified PMR polyimides required higher compression-molding pressures than state-of-the-art PMR-15. In this study PMR polyimides are prepared employing three encaps: NE, PAS, and endo-N-phenyl-5-norbornene-2,3-dicarboximide (PN). The effect of PN addition on the processing characteristics and glass transition temperatures of graphite fiber-reinforced PMR composites is studied. The room temperature and short-time 316 C mechanical properties of the composites are determined. The weight loss and mechanical property retention characteristics of the composites after exposure in air at 316 C are also determined.

Delvigs, P.↗

Kidney cell electrophoresis in space flight: Rationale, methods, results and flow cytometry applications

Cultures of human embryonic kidney cells consistently contain an electrophoretically separable subpopulation of cells that produce high levels of urokinase and have an electrophoretic mobility about 85 percent as high as that of the most mobile human embryonic kidney cells. This subpopulation is rich in large epithelioid cells that have relatively little internal structure. When resolution and throughput are adequate, free fluid electrophoresis can be used to isolate a broad band of low mobility cells which also produces high levels of plasminogen activators (PAs). In the course of performing this, it was discovered that all electrophoretic subpopulations of cultured human embryonic kidney cells produce some PAs and that separate subpopulations produce high quantities of different types of PA's. This information and the development of sensitive assays for this project have provided new insights into cell secretion mechanisms related to fibrinolysis. These advances would probably not have been made without the NASA program to explore fundamental questions of free fluid electrophoresis in space.

Todd, P.↗

Autoclavable addition polyimides for 371 C composite applications

Studies were conducted to improve the thermo-oxidative stability (TOS) of PMR type polyimides by the substitution of para-aminostyrene (PAS) for the nadic ester endcap in second generation PMR polyimides (PMR-2). The nadic endcap which provides the PMR polyimides with their relative ease of fabrication, both by limiting the molecular weight of the prepolymer and by undergoing the final addition cure without volatiles, is also the weak link with regard to TOS. A polyimide formulated with PAS endcaps, called V-CAP, utilizes a two step reaction sequence similar to that of the PMR polyimides and can be easily autoclave molded into low void composite materials. Resin studies included two formulations of both PMR-2 and V-CAP, corresponding to n=9 and n=14 prepolymer stoichiometry. Unidirectional reinforced T40R graphite fiber laminates were fabricated from each of the resins was post-cured in either air at 385 C or nitrogen at 400 C. Composite specimens were aged in air at 371 C and mechanical properties were measured at 371 C before and after exposure.

Vannucci, R. D.↗

A review and update of the NASA aircraft noise prediction program propeller analysis system

The National Aeronautics and Space Administration (NASA) Aircraft Noise Prediction Program (ANOPP) Propeller Analysis System (PAS) is a set of computational modules for predicting the aerodynamics, performance, and noise of propellers. The ANOPP PAS has the capability to predict noise levels for propeller aircraft certification and produce parametric scaling laws for the adjustment of measured data to reference conditions. A technical overview of the prediction techniques incorporated into the system is presented. The prediction system has been applied to predict the noise signature of a variety of propeller configurations including the effects of propeller angle of attack. A summary of these validation studies is discussed with emphasis being placed on the wind tunnel and flight test programs sponsored by the Federal Aviation Administration (FAA) for the Piper Cherokee Lance aircraft. A number of modifications and improvements have been made to the system and both DEC VAX and IBM-PC versions of the system have been added to the original CDC NOS version.

Golub, Robert A.↗

Autoclavable addition polyimides for 371 C composite applications

Studies were conducted to improve the thermo-oxidative stability (TOS) of PMR type polyimides by the substitution of para-aminostyrene (PAS) for the nadic ester endcap in second generation PMR polyimides (PMR-2). The nadic endcap which provides the PMR polyimides with their relative ease of fabrication, both by limiting the molecular weight of the prepolymer and by undergoing the final addition cure without volatiles, is also the weak link with regard to TOS. A polyimide formulated with PAS endcaps, called V-CAP, utilizes a two step reaction sequence similar to that of the PMR polyimides and can be easily autoclave molded into low void composite materials. Resin studies included two formulations of both PMR-2 and V-CAP, corresponding to n = 9 and n = 14 prepolymer stoichiometry. Unidirectional reinforced T40R graphite fiber laminates were fabricated from each of the resins was post-cured in either air at 385 C or nitrogen at 400 C. Composite specimens were aged in air at 371 C and mechanical properties were measured at 371 C before and after exposure.

Vannucci, R. D.↗

Slow-Positron Generator For Studying Polymer Films

Aspects of molecular structures probed by positron-annihilation spectroscopy (PAS). Slow-positron-beam generator suitable for PAS measurements in thin polymer films. Includes Na22 source of positrons and two moderators made of well-annealed tungsten foil. With proper choice of voltage, positrons emitted by inward-facing surfaces of moderators made to stop in polymer films tested.

Singh, Jag J.↗

Improved PMR Polyimides For Heat-Stable Laminates

Second-generation PMR-type polyimides (PMR-II polyimides) of enhanced thermo-oxidative stability prepared by substitution of para-aminostyrene (PAS) end caps for nadic-ester (NE) end caps used in prior PMR-II polyimides. Laminates unidirectionally reinforced with graphite fibers and made with PAS-capped resins exhibited thermo-oxidative stabilities significantly greater than those of similar laminates made with NE-capped PMR-II resins. One new laminate exhibited high retention of weight and strength after 1,000 h of exposure to air at 371 degrees C.

Vannucci, R. D.↗

Mission planning for Shuttle Imaging Radar-C (SIR-C) with a real-time interactive planning software

The Shuttle Imaging Radar-C (SIR-C) mission will operate from the payload bay of the space shuttle for 8 days, gathering Synthetic Aperture Radar (SAR) data over specific sites on the Earth. The short duration of the mission and the requirement for realtime planning offer challenges in mission planning and in the design of the Planning and Analysis Subsystem (PAS). The PAS generates shuttle ephemerides and mission planning data and provides an interactive real-time tool for quick mission replanning. It offers a multi-user and multiprocessing environment, and it is able to keep multiple versions of the mission timeline data while maintaining data integrity and security. Its flexible design allows one software to provide different menu options based on the user's operational function, and makes it easy to tailor the software for other Earth orbiting missions.

Potts, Su K.↗

USML-1 microgravity glovebox experiment no. 1 Passive Accelerometer System

The passive accelerometer system (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The accelerometer can be used when the spacecraft continuously rotates during the orbit such that some line of reference in the craft always points along the vector connecting the earth's mass center with the spacecraft mass center. PAS was used successfully on the first United States Microgravity Laboratory (USML-1).

Alexander, J. Iwan D.↗

Passive and Active Stabilization of Liquid Bridges in Low Gravity

Tests are planned in the low gravity environment of the International Space Station (ISS) of new methods for the suppression of the capillary instability of liquid bridges. Our suppression methods are unusual in that they are not limited to liquid bridges having very special properties and may impact a variety of low-gravity and earth-based technologies. There are two main approaches to be investigated: (1) Passive Acoustic Stabilization (PAS); and (2) Active Electrostatic Stabilization (AES). In PAS, the suppression of the mode growth is accomplished by placing the bridge in an acoustic field having the appropriate properties such that the acoustic radiation pressure automatically pulls outward on the thinnest portion of the bridge. In AES, the bridge deformation is sensed optically and counteracted by actively adjusting the electrostatic Maxwell stresses via two ring electrodes concentric with the slightly conducting bridge to offset the growth of the unstable mode. While the present work emphasizes cylindrical bridges, the methods need not be restricted to that case. The methods to be explored are relevant to the suppression of capillary instabilities in floating zone crystal growth, breakup of liquid jets and columns, bubbles, and annular films as well as the management of coolants or propellants in low-gravity.

Marston, Philip L.↗

Impaired pulmonary artery contractile responses in a rat model of microgravity: role of nitric oxide

Vascular contractile hyporesponsiveness is an important mechanism underlying orthostatic intolerance after microgravity. Baroreceptor reflexes can modulate both pulmonary resistance and capacitance function and thus cardiac output. We hypothesized, therefore, that pulmonary vasoreactivity is impaired in the hindlimb-unweighted (HLU) rat model of microgravity. Pulmonary artery (PA) contractile responses to phenylephrine (PE) and U-46619 (U4) were significantly decreased in the PAs from HLU vs. control (C) animals. N(G)-nitro-L-arginine methyl ester (10(-5) M) enhanced the contractile responses in the PA rings from both C and HLU animals and completely abolished the differential responses to PE and U4 in HLU vs. C animals. Vasorelaxant responses to ACh were significantly enhanced in PA rings from HLU rats compared with C. Moreover, vasorelaxant responses to sodium nitroprusside were also significantly enhanced. Endothelial nitric oxide synthase (eNOS) and soluble guanlyl cyclase expression were significantly enhanced in PA and lung tissue from HLU rats. In marked contrast, the expression of inducible nitric oxide synthase was unchanged in lung tissue. These data support the hypothesis that vascular contractile responsiveness is attenuated in PAs from HLU rats and that this hyporesponsiveness is due at least in part to increased nitric oxide synthase activity resulting from enhanced eNOS expression. These findings may have important implications for blood volume distribution and attenuated stroke volume responses to orthostatic stress after microgravity exposure.

Non-NASA Center↗

EXPRESS Pallet Payload Interface Requirements

A viewgraph presentation describing the EXPRESS Pallet Space Station payload interface requirements is shown. The topics include: 1) External Payload Sites; 2) EXPRESS Pallet with Six Payload Envelopes; 3) EXPRESS Pallet in Payload Bay Representative Layout; 4) EXPRESS Pallet Installation SSRMS positions pallet for PAS mating on S3 truss; 5) EXPRESS Pallet Major Components; 6) EXPRESS Pallet Adapter; 7) EXPRESS Pallet Center Location Payload Envelope; 8) Envelope Restriction for EXPRESS Pallet Corner Payload Locations; 9) EXPRESS Pallet-PAS Truss Configuration; and 10) EXPRESS Pallet Payload Services and Specifications.

Holt, Alan C.↗

Space Interferometry Mission Science Overview

Conclusions: SIM is on track for a launch in 2010. Project 'Phase C' start in October 2005. SIM is a flexibly-pointed instrument Astrometric capability (wide angle) a) 4 pas parallax precision on targets down to V = 20 = Stellar and Galactic astrophysics; and b) 1 pas single measurement accuracy. Sensitive to terrestrial-mass planets around the nearest stars New proposal opportunities are: a) AO-2 for new (large) Key projects - 2005; and b) General Observer program, for smaller proposals - 2006.

planet searching↗