Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OpenCV and TYZX : video surveillance for tracking.

As part of the National Security Engineering Institute (NSEI) project, several sensors were developed in conjunction with an assessment algorithm. A camera system was developed in-house to track the locations of personnel within a secure room. In addition, a commercial, off-the-shelf (COTS) tracking system developed by TYZX was examined. TYZX is a Bay Area start-up that has developed its own tracking hardware and software which we use as COTS support for robust tracking. This report discusses the pros and cons of each camera system, how they work, a proposed data fusion method, and some visual results. Distributed, embedded image processing solutions show the most promise in their ability to track multiple targets in complex environments and in real-time. Future work on the camera system may include three-dimensional volumetric tracking by using multiple simple cameras, Kalman or particle filtering, automated camera calibration and registration, and gesture or path recognition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Particle motion on Mars inferred from the Viking lander cameras

Data from Viking lander cameras indicate fine particle mobility on the surface of Mars such as: probable ventifacts, rock-associated raised streaks, and particulate drifts. Peak wind directions inferred from Chryse and Utopia are roughly equal, and are consistant with those inferred by orbiter photography. A 24 deg systematic offset between: (1) the direction of rock-associated streaks in the Viking I landing site, and (2) Mariner 9 and Viking observations of crater-associated streaks is consistant with a Coriolis acceleration of particles entrained by high-velocity winds during the production of crater-associated streaks. It is suggested that if a large fraction of collision impact energy goes into deformation, strain, and rupture, a preferential destruction of the most easily saltated grains and a depletion of 15-micron diameter grains will be observed. Investigations of particulates dumped on the landing grid suggest that major saltation events took place between sols 96 and 207, caused by winds of greater than 50 meters/sec normalized to the top of the boundary layer.

Sagan, C.↗

Kinetics of small single particle combustion of zirconium alloy

We present quantitative kinetic information regarding small, 1-10 {mu}m in diameter, single particle combustion of Zr-rich metal alloy foils subjected to either mechanical impacts or laser-ablation. The lights from combustion of metal fragments were recorded on a high-speed camera. The particle size was determined by the motion analysis of individual particle trajectory based on an aerodynamic drag law and further verified by the microstructure and chemical composition analysis of recovered post-burn particles. The measured particle sizes show a log-normal distribution centered at around 3.1 {mu}m in diameter, and the composition of recovered particles is that of fully oxidized ZrO{sub 2}. The temperature evolution of each particle along the space/time-trajectory is determined based on the thermal emission from combustion using a single-color photographic spectro-pyrometry. The result indicates that the particle has reached the maximum combustion temperature of 4000 K, well beyond the melting temperature of ZrO{sub 2}, and undergone the solidification of molten ZrO{sub 2} during the cooling stage. It also shows that the maximum combustion temperature decreases linearly with increasing the particle diameter, following the correlation t aD{sup 1.5-1.8} between the burn time (t) and the particle diameter (D). Combining the particle size, the burn time, and the particle temperature, both temperature and mass burn rates are obtained as a function of particle size. As the particle size increases, the temperature burn rate decreases, whereas the mass burn rate goes in the opposite direction.

36 MATERIALS SCIENCE↗

Digital Particle Image Velocimetry (DPIV) Used for Space-Time Correlations in Nozzle Flow

An optical measurement technique known as Digital Particle Image Velocimetry (DPIV) was used previously to characterize the first- and second-order statistical properties of both cold and hot jet flows from externally mixed nozzles in NASA Glenn Research Center's Nozzle Acoustic Test Rig. In this technique, an electronic camera records particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Correlation processing of the recorded particle image pairs yields the two-component velocity field across the imaged plane of the flow. The information acquired using DPIV is being used to improve our understanding of the decay of turbulence in jet flows-a critical element for understanding the acoustic properties of the flow. Recently, two independent DPIV systems were installed in Glenn's Small Hot Jet Acoustic Rig, enabling multiplane correlations in time and space. The data were collected over a range of different Mach numbers and temperature ratios. DPIV system 1 was fixed to a large traverse rig, and DPIV system 2 was mounted on a small traverse system mounted on the large traverse frame. The light sheets from the two DPIV systems were aligned to lie in the same axial plane, with DPIV system 2 being independently traversed downstream along the flow direction. For each measurement condition, the DPIV systems were started at a fully overlapping orientation. A polarization separation technique was used to avoid cross-talk between the two systems. Then, the DPIV systems fields were shifted axially apart, in successively increasing steps. The downstream DPIV system 2 was triggered at a short time delay after the upstream DPIV system 1, where the time delay was proportional to the convective flow velocity in the shear layer of the jet flow and the axial separation of the two DPIV systems. The acquired data were processed to obtain the instantaneous velocity vector maps over a range of time delays and spatial separations. The velocity fields from the different DPIV systems were then cross-correlated to determine the degree of correlation remaining in the flow as the downstream convection distance was increased. The new data provide Lagrangian measurements of the convective turbulent structures in the shear layer of an exhaust nozzle. These measurements, obtained in both cold and hot flows, will be used to validate and correct models for space-time velocity correlations-long a missing key to predicting jet noise.

Wernet, Mark P.↗

Dust measurements in tokamaks (invited)

Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 {mu}m in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C{sub 2} dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dust Measurements in Tokamaks

Dust production and accumulation impose safety and operational concerns for ITER. Diagnostics to monitor dust levels in the plasma as well as in-vessel dust inventory are currently being tested in a few tokamaks. Dust accumulation in ITER is likely to occur in hidden areas, e.g. between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering resolves size of particles between 0.16-1.6 {micro}m in diameter; the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast-framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in 2D with a single camera or 3D using multiple cameras, but determination of particle size is problematic. In order to calibrate diagnostics and benchmark dust dynamics modeling, pre-characterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase of carbon atomic, C2 dimer, and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recorded independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

Patient positioning in radiotherapy based on surface imaging using time of flight cameras

Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

60 APPLIED LIFE SCIENCES↗

The particulate environment surrounding the space station: Estimates from the PACS data

The objectives of the Particle Analysis Cameras for Shuttle (PACS) experiment (flown on STS-61C) are described and the experiment results are discussed in reference to the expected Space Station environment. Estimates of the sources of particulates surrounding the Space Station were made based on the existing orbital observations data base. Particulates surrounding the shuttle are mostly event related or from the residual release of mass (dust) brought to orbit from the ground. The particulates surrounding the Space Station are likely to arise from additional sources such as operations, docking, erosion, and abrasion. Thus, scaling of the existing data base to long-duration missions in low-Earth orbit requires analysis, modeling, and simulation testing.

Green, Byron David↗

Compact Instrumentation for Experiments on the Lunar Surface

Increased opportunities to fly payloads on orbital, lander, and/or rover platforms will greatly facilitate the meeting of high priority goals for lunar exploration and lunar science, especially those requiring distributed measurements on multiple platforms to be fully realized. Compact, robust versions of instruments, designed to be integrated with a variety of platforms, or utilized in astronaut-deployed or handheld devices are already under development. These include cameras, spectrometers, particle analyzers, field instruments, and seismometers,

Clark, Pamela E.↗