The Environmental Effects Branch at the Marshall Space Flight Center supports a myriad array of programs for NASA, DoD, and commercial space including human exploration, advanced space propulsion, improving life on Earth, and the study of the Sun, the Earth, and the solar system. The branch provides testing, evaluation, and qualification of materials for use on external spacecraft surfaces and in contamination-sensitive systems. Space environment capabilities include charged particle radiation, ultraviolet radiation, atomic oxygen, impact, plasma, and thermal vacuum, anchored by flight experiments and analysis of returned space hardware. These environmental components can be combined for solar wind or planetary surface environment studies or to evaluate synergistic effects. The Impact Testing Facility allows simulation of impacts ranging from sand and rain to micrometeoroids and orbital debris in order to evaluate materials and components for flight and ground-based systems. The Contamination Control Team is involved in the evaluation of environmentally-friendly replacements for HCFC-225 for use in propulsion oxygen systems, developing cleaning methods for additively manufactured hardware, and reducing risk for the Space Launch System.
Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities.
The elimination of CFC-containing cleaning solvents for oxygen systems has prompted the development of a number of alternative cleaning solvents that must now be evaluated not only for cleanability, but compatibility as well. NASA Handbook 8060.1(NHB 8060.1) establishes the requirements for evaluation, testing, and selection of materials for use in oxygen rich environments. Materials intended for use in space vehicles, specified test facilities, and ground support equipment must meet the requirements of this document. In addition to the requirements of NHB 8060.1 for oxygen service, alternative cleaning solvents must also be evaluated in other areas (such as corrosivity, non-metals compatibility, non-volatile residue contamination, etc.). This paper will discuss the testing requirements of NHB 8060.1 and present preliminary results from early screening tests performed at Marshall Space Flight Center's Materials Combustion Research Facility.
The Nitrogen system is a vital utility supporting the curation office within NASA's Astromaterials Re-search and Exploration Science (ARES) Division at the Johnson Space center (JSC). Since the Apollo samples were returned in 1969. It has played an essential role in preserving NASA’s astromaterial collections (now nine collections) by maintaining contamination-free, controlled environments required for long term curation and advanced scientific research. To meet the stringent purity requirements for contamination control, high purity modified Grade C Liquid Nitrogen (LN2) is delivered weekly by an industrial gas vendor to a 15,000-gallon tank located outside at NASA JSC near the ARES facility. This nitrogen is vital for creating an inert atmosphere to store the collection in, ensuring they are continuously shielded from contaminants and alterations through a constant N2purge. For most of the past 65 years deliveries of LN2 have required a CoA (Certificate of Analysis) prior to delivery. If those were not available, then LN2 deliver were sent to third-party laboratories for verification, creating an operational bottleneck and quality gap. To address this challenge and maintain rigorous quality control, NASA JSC Infrastructure and Astromaterials Acquisition & Curation Office initiated the development of an on-site Analytical Gas Sampling (AGS) Laboratory. Designed to streamline quality verification if a CoA unavailable, the AGS lab was constructed by a subcontractor in Newton, NJ. After a successful factory acceptance test conducted by the NASA ARES Infrastructure team, the lab was trans-ported to NASA JSC, where it was anchored and integrated into the site’s nitrogen pressure system using stainless steel, oxygen-cleaned tubing. The ARES nitrogen system was modified to provide parallel flows to the AGS lab for quality control and to the astromaterials collection labs for maintaining an inert environment. The AGS lab features two operational modes: (1)Primary: Gaseous Nitrogen (GN2) Quality Monitoring –The AGS system continuously samples the site’s GN2 supply every 15 minutes to ensure compliance with required purity levels. (2) Secondary: LN2 Quality Verification when a comprehensive CoA is not available, a cryogenic vaporizer converts LN2 to GN2, which is then analyzed for impurities: H₂, Ar, O₂, CO, CO₂, H₂O, and total hydrocarbons (THC). By significantly enhancing on-site analytical capabilities, the AGS lab eliminates reliance on external testing, ensures uninterrupted quality monitoring of the nitrogen pressure system, and reinforces NASA’s commitment to preserving pristine astromaterials under the highest standards of curation and research integrity.
A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.
Aerospace machinery used in liquid oxygen (LOX) fuel systems must be precision cleaned to achieve a very low level of non-volatile residue (< 1 mg0.1 m2), especially flammable residue. Traditionally chlorofluorocarbons (CFCs) have been used in the precision cleaning of LOX systems, specifically CFC 113 (C2Cl3F3). CFCs have been known to cause the depletion of ozone and in 1987, were banned by the Montreal Protocol due to health, safety and environmental concerns. This has now led to the development of new processes in the precision cleaning of aerospace components. An ideal solvent-replacement is non-flammable, environmentally benign, non-corrosive, inexpensive, effective and evaporates completely, leaving no residue. Highlighted is a green precision cleaning process, which is contaminant removal using supercritical carbon dioxide as the environmentally benign solvent. In this process, the contaminant is dissolved in carbon dioxide, and the parts are recovered at the end of the cleaning process completely dry and ready for use. Typical contaminants of aerospace components include hydrocarbon greases, hydraulic fluids, silicone fluids and greases, fluorocarbon fluids and greases and fingerprint oil. Metallic aerospace components range from small nuts and bolts to much larger parts, such as butterfly valves 18 in diameter. A fluorinated grease, Krytox, is investigated as a model contaminant in these preliminary studies, and aluminum coupons are employed as a model aerospace component. Preliminary studies are presented in which the experimental parameters are optimized for removal of Krytox from aluminum coupons in a stirred-batch process. The experimental conditions investigated are temperature, pressure, exposure time and impeller speed. Temperatures of 308 - 423 K, pressures in the range of 8.3 - 41.4 MPa, exposure times between 5 - 60 min and impeller speeds of 0 - 1000 rpm were investigated. Preliminary results showed up to 86 cleaning efficiency with the moderate processing conditions of 323 K, 13.8 MPa, 30 min and 750 rpm.
Gaseous and liquid oxygen are extremely reactive materials used in bipropellant propulsion systems. Both flight and ground oxygen systems require a high level of cleanliness to support engine performance, testing, and prevent mishaps. Solvents used to clean and verify the cleanliness of oxygen systems and supporting test hardware must be compatible with the system's materials of construction and effective at removing or reducing expected contaminants to an acceptable level. This paper will define the philosophy and test approach used for evaluating replacement solvents for the current Marshall Space Flight Center/Stennis Space Center baseline HCFC‐225 material that will no longer be available for purchase after 2014. MSFC/SSC applications in cleaning / sampling oxygen propulsion components, support equipment, and test system were reviewed then candidate replacement cleaners and test methods selected. All of these factors as well as testing results will be discussed.
Special considerations for oxygen systems engineering with respect to system design, fabrication, and use are studied. The concerns for oxygen systems include the problems of leakage and erosion, difficulties that arise from dynamic processes, and the sensitivity of oxygen systems to contamination and cleaning requirements.
A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Division of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation, frequency vs. cleaning effectiveness, the two types of transducers, and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.
A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Div. of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation; frequency vs. cleaning effectiveness; the two types of transducers; and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.
A modular boiler system for implementing fuel combustion is provided. The system includes a first boiler and a second boiler of a plurality of boilers, an oxygen input unit, a fuel input unit, a recycled flue gas input unit, and a flue gas separator. The first boiler receives oxygen from the oxygen input unit, fuel from the fuel input unit, and recycled flue gas from the recycled flue gas input unit. The first boiler outputs intra-system flue gas. The flue gas separator separates the intra-system flue gas into a first and second flue gas stream, transfers the first flue gas stream to the second boiler, and transfers the second flue gas stream to a gas cleaning system. The second boiler receives oxygen from the oxygen input unit, fuel from the fuel input unit, and the first flue gas stream from the flue gas separator.
Materials used or contained in liquid and gaseous oxygen systems are analyzed for their compatibility; and areas of possible concern in oxygen systems are outlined. Design criteria, cleaning procedures, and quality control methods are covered in detail.
Precision cleaning solvents for aerospace components and oxygen fuel systems, including currently used Vertrel-MCA, have a negative environmental legacy, high global warming potential, and have polluted cleaning sites. Thus, alternative solvents and technologies are being investigated with the aim of achieving precision contamination levels of less than 1 mg/sq ft. The technologies being evaluated are ultrasonic bath cleaning, plasma cleaning and supercritical carbon dioxide cleaning.
Calibration of pressure gages is accomplished by use of fluid chamber in conjunction with conventional single chamber hydraulic deadweight tester. System eliminates cleaning of gages with liquid oxygen after tests and is simple to construct and operate.
On January 1, 2015, the United States Environmental Protection Agency identified exemptions on the continued use of the hydrochlorofluorocarbon (HCFC)-225ca and -225cb. As these solvents are commonly used in cleaning and verification of aerospace propulsion systems using liquid and gaseous oxygen, the NESC supported the Agency initiative to identify and characterize acceptable alternate fluids. Honeywell’s Solstice® Performance Fluid (PF), PF-high purity (HP), and PF-HP spray are an effective nonflammable cleaning solution system, with a favorable toxicity profile and low environmental impact. Solstice PF is suitable for electronics, metal, and precision cleaning. It can be used in vapor degreasing equipment and may be dispensed with a propellant to create an aerosol contact cleaner. Solstice PF has been shown to have negligible ozone depletion and a global warming potential of 1. With these characterized environmental and solvency properties, Solstice PF, PF-HP, or PF-HP spray may be an excellent choice for a variety of cleaning applications.