Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Outage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Outage Cause Classification of Power Distribution Systems with Machine Learning and Real-World Data

Power distribution systems are geographically dispersed by nature. It may be affected by various factors, such as vegetation, weather, animal and human behaviors. Present response procedures to an outage event massively rely on expert experience and thus tend to be time-consuming. Automatic outage event detection and classification will help to reduce the responding and restoration time. However, this issue is less addressed with existing research done in this area. In this applied research, a set of waveform pre-processing techniques are first proposed to prepare the waveform data for being used as inputs to the classification algorithm. Further, a machine learning-based algorithm is proposed to classify the outage events according to their root causes, e.g. tree contact, animal contact, lightning, etc. Available data include three phase current & voltage waveforms and contextual information during the distribution system outages. The proposed machine learning algorithm takes the current and voltage waveforms as direct inputs in search of features that humans are unable to capture. Real data provided by a distribution company in the East Tennessee region is used to test the proposed pre-processing techniques and the classification algorithm.

Sun, Haoyuan↗

Supporting Disaster Assessment and Response with the VIIRS Day-Night Band

When meteorological or man‐made disasters occur, first responders often focus on impacts to the affected population and other human activities. Often, these disasters result in significant impacts to local infrastructure and power, resulting in widespread power outages. For minor events, these power outages are often short-lived, but major disasters often include long‐term outages that have a significant impact on wellness, safety, and recovery efforts within the affected areas. Staff at NASA's Short‐term Prediction Research and Transition (SPoRT) Center have been investigating the use of the VIIRS day‐night band for monitoring power outages that result from significant disasters, and developing techniques to identify damaged areas in near real‐time following events. In addition to immediate assessment, the VIIRS DNB can be used to monitor and assess ongoing recovery efforts. In this presentation, we will highlight previous applications of the VIIRS DNB following Superstorm Sandy in 2012, and other applications of the VIIRS DNB to more recent disaster events, including detection of outages following the Moore, Oklahoma tornado of May 2013 and the Chilean earthquake of April 2014. Examples of current products will be shown, along with future work and other goals for supporting disaster assessment and response with VIIRS capabilities.

Schultz, Lori A.↗

Use of VIIRS DNB Data to Monitor Power Outages and Restoration for Significant Weather Events

NASA fs Short-term Prediction Research and Transition (SPoRT) project operates from NASA's Marshall Space Flight Center in Huntsville, Alabama. The team provides unique satellite data to the National Weather Service (NWS) and other agencies and organizations for weather analysis. While much of its work is focused on improving short-term weather forecasting, the SPoRT team supported damage assessment and response to Hurricane Superstorm Sandy by providing imagery that highlighted regions without power. The team used data from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (Suomi NPP) satellite. The VIIRS low-light sensor, known as the day-night-band (DNB), can detect nighttime light from wildfires, urban and rural communities, and other human activity which emits light. It can also detect moonlight reflected from clouds and surface features. Using real time VIIRS data collected by our collaborative partner at the Space Science and Engineering Center of the University of Wisconsin, the SPoRT team created composite imagery to help detect power outages and restoration. This blackout imagery allowed emergency response teams from a variety of agencies to better plan and marshal resources for recovery efforts. The blackout product identified large-scale outages, offering a comprehensive perspective beyond a patchwork GIS mapping of outages that utility companies provide based on customer complaints. To support the relief efforts, the team provided its imagery to the USGS data portal, which the Federal Emergency Management Agency (FEMA) and other agencies used in their relief efforts. The team fs product helped FEMA, the U.S. Army Corps of Engineers, and U.S. Army monitor regions without power as part of their disaster response activities. Disaster responders used the images to identify possible outages and effectively distribute relief resources. An enhanced product is being developed and integrated into a web mapping service (WMS) for dissemination and use by a broader end user community.

Jedlovec, Gary↗

Characterization of Nighttime Light Variability Over the Southeastern United States

City lights provide indications of human activity at night. Nighttime satellite imagery offers daily snapshots of this activity. With calibrated, science-quality imagery, long-term monitoring can also be achieved. The degree to which city lights fluctuate, however, is not well known. For the application of detecting power outages, this degree of variability is crucial for assessing reductions to city lights based on historical trends. Eight southeastern U.S. cities are analyzed to understand the relationship between emission variability and several population centers. A preliminary, example case power outage study is also discussed as a transition into future work.

VIIRS↗

Random Forest Regressor-Based Approach for Detecting Fault Location and Duration in Power Systems

Power system failures or outages due to short-circuits or “faults” can result in long service interruptions leading to significant socio-economic consequences. It is critical for electrical utilities to quickly ascertain fault characteristics, including location, type, and duration, to reduce the service time of an outage. Existing fault detection mechanisms (relays and digital fault recorders) are slow to communicate the fault characteristics upstream to the substations and control centers for action to be taken quickly. Fortunately, due to availability of high-resolution phasor measurement units (PMUs), more event-driven solutions can be captured in real time. In this paper, we propose a data-driven approach for determining fault characteristics using samples of fault trajectories. A random forest regressor (RFR)-based model is used to detect real-time fault location and its duration simultaneously. This model is based on combining multiple uncorrelated trees with state-of-the-art boosting and aggregating techniques in order to obtain robust generalizations and greater accuracy without overfitting or underfitting. Four cases were studied to evaluate the performance of RFR: 1. Detecting fault location (case 1), 2. Predicting fault duration (case 2), 3. Handling missing data (case 3), and 4. Identifying fault location and length in a real-time streaming environment (case 4). A comparative analysis was conducted between the RFR algorithm and state-of-the-art models, including deep neural network, Hoeffding tree, neural network, support vector machine, decision tree, naive Bayesian, and K-nearest neighborhood. Experiments revealed that RFR consistently outperformed the other models in detection accuracy, prediction error, and processing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Invite the Chaos Monkey: Test Effect Payloads for Tuning ICS Incident Response

In 2010, when Netflix moved their operational systems to the cloud, they developed a pseudo-random mechanism to cause deliberate outages and failures of key system elements to ensure that automated systems for detecting and remediating outages were mature and fully functional. This Chaos Monkey spawned an entire Simian Army designed to ensure system resilience and enable failure response before issues became outages. Through the DARPA RADICS program, Provatech, INL, and other researchers have developed a mechanism for creating controllable failures via Test Effect Payloads (TEPs) for Industrial Control Systems in order to enable an asset owner to tune network and process sensor technology, increase the effectiveness of incident response and remediation, and highlight areas where resilient technology could bring benefit to Operational Technology. This talk will explore what a TEP is, how to create a TEP, and suggest what a systematic system resilience plan using TEP’s might look like. We will also discuss how regulated entities might employ TEP’s in a compliant resilience strategy.

42 ENGINEERING↗

Using Current Data to Detect Hardware Faults at Solar Plants

Monitoring amperage data is an effective means of detecting faults in PV plant data. Utilizing amperage data collected at the combiner box gives plant operators an up-to-date list of faulted equipment, allowing them to coordinate maintenance needs at much shorter intervals than previously. Shorter maintenance intervals will increase PV plant production levels, narrowing the gap between expected and actual PV plant performance. The amperage monitoring method performs at a high level, with a string-outage related fault detection True Positive Rate of 46% and False Positive Rate of 8%.

14 SOLAR ENERGY↗

Improvements to Lunar BRDF-Corrected Nighttime Satellite Imagery: Uses and Applications

Observations made by the VIIRS day/night band (DNB) provide daily, nighttime measurements to monitor Earth surface processes.However, these observations are impacted by variations in reflected solar radiation on the moon's surface. As the moon transitions from new to full phase, increasing radiance is reflected to the Earth's surface and contributes additional reflected moonlight from clouds and land surface, in addition to emissions from other light sources observed by the DNB. The introduction of a bi-directional reflectance distribution function (BRDF) algorithm serves to remove these lunar variations and normalize observed radiances. Provided by the Terrestrial Information Systems Laboratory at Goddard Space Flight Center, a 1 km gridded lunar BRDF-corrected DNB product and VIIRS cloud mask can be used for a multitude of nighttime applications without influence from the moon. Such applications include the detection of power outages following severe weather events using pre-and post-event DNB imagery, as well as the identification of boat features to curtail illegal fishing practices. This presentation will provide context on the importance of the lunar BRDF correction algorithm and explore the aforementioned uses of this improved DNB product for applied science applications.

NWS↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

Detection of Ionospheric Alfven Resonator Signatures in the Equatorial Ionosphere

The ionosphere response resulting from minimum solar activity during cycle 23/24 was unusual and offered unique opportunities for investigating space weather in the near-Earth environment. We report ultra low frequency electric field signatures related to the ionospheric Alfven resonator detected by the Communications/Navigation Outage Forecasting System (C/NOFS) satellite in the equatorial region. These signatures are used to constrain ionospheric empirical models and offer a new approach for monitoring ionosphere dynamics and space weather phenomena, namely aeronomy processes, Alfven wave propagation, and troposphere24 ionosphere-magnetosphere coupling mechanisms.

Simoes, Fernando↗

Physics-Based Feature Extraction from Bulk Time-Series PMU Datasets for Event Detection

In this work, two physics-based feature extraction techniques are developed for bulk time-series phasor measurement unit (PMU) datasets collected from the field to train the machine learning model for anomaly detection. Two approaches have been developed to extract useful features for different types of events. An admittance-based feature extraction technique is developed to detect events that involve line outages and system topology variations. The developed algorithm extracts the system equivalent admittance variation. Additionally, Fielder’s Theory is utilized to further reduce the potential computation burden by sectionalizing large-scale grids and datasets into smaller areas. Second, an oscillation-based feature extraction technique is developed to detect low-frequency oscillations in power grids. The dominant oscillation modes in the grids are extracted using energy-sorted Prony analysis. The extracted dominant oscillation modes by the developed work exhibit a high fitting resolution. Finally, the developed techniques have been validated using large-scale and real-world datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and Control Theory for Smart (Power) Grids [Slides]

The national interest in a broad class of problems loosely characterized as the smart grid is rapidly growing. At its core, the smart grid is the modernization of our existing electric power systems through improvements in efficiency, increased robustness and resiliency, integration of time-variable renewable generation, and reduction of environmental impacts. To date, the focus of most commercial entities has been on development of hardware such as smart meters and green technologies. However, with the exception of a handful of academic researchers, there has been limited research on optimization, control and more broadly, the information science required to effectively utilize this hardware. Our proposal targets development of the basic information science that will effectively bridge this gap. Using our expertise in information theory, network analysis, infrastructure analysis and power engineering, we will develop new algorithms for optimal design of the nation's next generation power transmission and distribution system that address the realities and challenges of the future grid. We focus on three core information science challenges in Grid Design, Grid Control and Grid Stability by considering a set of challenging problems. First, we study efficient and robust integration of geographically widespread renewable generation by solving large, cutting-edge optimization problems that incorporate difficult constraints imposed by the transmission of electrical power. Second, we consider two load balancing problems in the low-voltage distribution grid: development of robust and efficient distributed control techniques and algorithms based on queuing theory. These tools will enable high penetration of small-scale distributed generation and plug-in hybrid vehicles with limited or no communications. We will also develop efficient control algorithms for maintaining an operational distribution grid via switching of redundant lines. Third, we will develop a preventive toolbox capable of detecting instabilities and failures prior to their occurrence. Damaging failures and cascading outages, which can result in billions of dollars worth of damage, have substantial economic consequences. We will focus on estimating the probability of these outages, identifying their signatures and precursors, and developing detection algorithms for alerting the transmission grid operator. The new challenges in IS&T for smart grids require coherent advances in analysis and control, stability and reliability metrics, state estimation, data aggregation and assimilation, and communication middleware for the grid as well as understanding consumer response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of Operational Total Lightning Data During Long-Track Tornadoes

The 27 April 2011 tornado outbreak brought three distinct waves of tornadic thunderstorms to portions of Mississippi, Alabama, Tennessee, and Georgia, striking the Tennessee Valley of north Alabama and southern Tennessee particularly hard. A total of 42 tornado paths were surveyed across the fourteen county area covered by the National Weather Service (NWS) forecast office in Huntsville, Alabama. Ten of these tornadoes were on the ground for at least 20 miles, two had total path lengths over 130 miles, and six tornadoes were classified as violent (EF-4 or EF-5 on the Enhanced Fujita Scale). Many of these tornadoes occurred within the domain of the North Alabama Lightning Mapping Array (NALMA), a ground-based total lightning detection network owned and operated by the NASA Marshall Space Flight Center. Since 2003, the NASA Short-term Prediction Research and Transition Center has supplied data from NALMA in real time to NWS forecast offices in Huntsville, Knoxville/Tri-Cities, Birmingham, and Nashville. Previous research has documented the utility of total lightning information in predicting tornadogenesis, particularly when combined with other remote sensing tools. Basic warning decision-making during events such as 27 April is not the most difficult part of the process; instead, the focus of warning meteorologists shifts to looking for changes in intensity or possible particularly dangerous situations, since doppler radar velocity data often cannot distinguish between weak and strong tornadoes. To that end, this research attempts to determine if any correlation exists between flash densities of the longest-tracked tornadoes over time, and the surveyed wind speeds of the tornadoes. The long-track EF-5 tornado which struck the Hackleburg, Phil Campbell, and Tanner communities in north Alabama was the primary focus of this research due to its intensity and extended life cycle. However, not all tornadoes were available for total lightning analysis due to widespread power outages which negatively affected the detection efficiency and operation of the NALMA. Therefore, additional storms from 2008-2010 with tracks of at least 20 miles were analyzed for comparison purposes.

Carcione, Brian C.↗

Utilizing Genetic Programming to Identify Failures in ICS Networks

Previously, researchers have attempted to apply machine learning techniques to network anomaly detection problems. Due to the staggering amount of variety that can occur in normal networks, the results have often been underwhelming. These challenges are far less pronounced when considering industrial control system (ICS) networks. The recurrent nature of these networks results in less noise and more consistent patterns for a machine learning algorithm to recognize. Here, we propose a method of evolving decision trees through genetic programming (GP) in order to detect network anomalies, such as device outages. Our approach extracts over a dozen features from network packet captures and netflows, normalizes them, and relates them in decision trees using fuzzy logic operators. Furthermore, the trees were used to detect three specific network events from three different points on the network across a statistically significant number of runs and achieved 100% accuracy on five of the nine experiments. When the trees attempted to detect more challenging events at points of presence further from the occurrence, the accuracy averaged to above 98%. Finally, using our method, all of the evolutionary cycles of the GP algorithm are computed a-priori, allowing the best resultant trees to be deployed as semi-real-time sensors with little overhead.

97 MATHEMATICS AND COMPUTING↗