Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nonionizing Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Origins of the 12-200 micron flux in NGC 6946 - Starlight and continuum dust emission from AN Sc galaxy

Infrared maps and optical CCD images of NGC 6946, a nearly face-on spiral with evidence of active star formation, are presented. Consideration is given, at 1-3 kpc spatial scales, to the relationship of the infrared continuum to spiral and radial structure, tracers of the interstellar medium, and ionizing and nonionizing sources of stellar radiation. Two infrared components were revealed - one with surface brightnesses of 20-60 Jy per 45 arcsec aperture at 160 microns, and the other with a surface brightness of less than 20 Jy. Various continuum distributions show discrete sources coinciding with giant H II regions superposed on a smooth unresolved disk background which decreases exponentially with the radius. The optical and spectral properties of the nuclear source and the disk are described. Dust properties and heating conditions, and far-infrared emitting phases are discussed.

Engargiola, G.↗

Ultraviolet radiation therapy and UVR dose models

Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed.

60 APPLIED LIFE SCIENCES↗

SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613; Elekta Sponsored Research.

60 APPLIED LIFE SCIENCES↗

Tolerance of Perovskite Solar Cells to Targeted Proton Irradiation and Electronic Ionization Induced Healing

Mixed organic–inorganic halide perovskite solar cells (PSCs) are of interest for space photovoltaic applications due to their apparent tolerance to high-energy proton radiation. Here, the use of a more stable wide-bandgap FA0.8Cs0.2PbI2.4Br0.6Cl0.02 perovskite with thin encapsulation enables, for the first time, the detailed dependence of fluence and energy of energetic protons on device performance. Energies were chosen to provide the highest concentration of displacements within the active region, and therefore the highest amount of degradation. Not only are these devices tolerant when compared to conventional technologies, but an unexpected increase in open circuit voltage and power density is observed for increased electronic ionization when the proton energy is increased. This study aims to expand the description of the proton radiation tolerance to include not only nonionizing nuclear energy losses that are most detrimental to current technologies, but electronic ionization, which is shown to yield benefits in PSCs.

device performance↗

Radiation-induced loss of unsaturation in 1,2-polybutadiene

The radiation induced loss of unsaturation and methyl production in 1,2-polybutadiene (VB) was studied using IR spectroscopy. It was found that G(-1,2), which depends on the initial vinyl content, decreased from approximately 550 for VB with 98.5% 1,2 initially, to approximately 270 for VB with 85% 1,2 initially. G(-trans-1,4) ranged from approximately 21 for VB with 14% trans-1,4 to nearly zero for VB with less than 1% trans-1,4 initially. Methyl production was found to equal one methyl group formed for every 4-5 vinyl units consumed in the radiation-cyclized VB, in contrast to one methyl formed for every two vinyls reacted during cationic cyclization to give monocyclic structures. The IR spectra of gamma-irradiated VB were very similar to the spectra of UV-irradiated or thermally-treated VB at the same residual vinyl contents. It is suggested that the radiation-induced cyclization of VB occurs by a nonionic, nonradical 'energy chain' mechanism, which apparently holds for the cyclization of VB, whether induced by gamma-rays, UV radiation, or heat.

Golub, M. A.↗

Electron and proton damage on InGaAs solar cells having an InP window layer

As part of a continuing program to determine the space radiation resistance of InP/ln(0.53)Ga(0.47)As tandem solar cells, n/p In(0.53)Ga(0. 47)As solar cells fabricated by RTI were irradiated with 1 MeV electrons and with 3 MeV protons. The cells were grown with a 3 micron n-lnP window layer to mimic the top cell in the tandem cell configuration for both AMO solar absorption and radiation effects. The results have been plotted against 'displacement damage dose' which is the product of the nonionizing energy loss (NIEL) and the particle fluence. A characteristic radiation damage curve can then be obtained for predicting the effect of all particles and energies. AMO, 1 sun solar illumination IV measurements were performed on the irradiated InGaAs solar cells and a characteristic radiation degradation curve was obtained using the solar cell conversion efficiency as the model parameter. Also presented are data comparing the radiation response of both n/p and p/n (fabricated by NREL) InGaAs solar cells as a function of base doping concentration. For the solar cell efficiency, the radiation degradation was found to be independent of the sample polarity for the same base doping concentration.

Messenger, Scott R.↗

A high-resolution far-infrared survey of the W31 region

A 1-m balloon-borne telescope was used to conduct a far-infrared survey of the W31 region at an effective wavelength of 69 microns with a resolution of 1 arcmin. Within this region seven far-infrared sources were observed. Five of these sources were associated with thermal radio emission. For each of these sources the infrared luminosity is much greater than the Ly-alpha luminosity, a situation requiring either dust absorption of Lyman-continuum photons or a large nonionizing stellar luminosity. Two faint infrared sources had no radio counterparts. Far-infrared radiation was not detected from two known radio sources and from one midinfrared source in this region.

Wright, E. L.↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Pediatric Abdominal Organ Motion With a 4-Dimensional Magnetic Resonance Imaging Method

Purpose: To characterize respiration-induced abdominal organ motion in children receiving radiation treatment with a 4-dimensional (4D) magnetic resonance imaging (MRI) method. Methods and Materials: We analyzed free-breathing coronal 4D MRI datasets acquired from 35 patients (aged 1-20 years) with abdominal tumors. A deformable image registration of the 4D MRI datasets was performed to derive motion trajectories of selected anatomic landmarks, from which organ motions were quantified. The association between organ motion and patient characteristics was investigated and compared with previous studies. The relation between patient height and organ motion was further investigated to predict organ motion in prospective patients. Results: Organ motion and its individual variation were reduced in younger patients (eg, kidney peak-to-peak motion <5 mm for all but 1 patient aged ≤8 years), although special motion management may be warranted in some adolescents. The liver and spleen exhibited greater motion than did the kidneys, while intraorgan variation was present. The motions in the liver and kidneys agreed with those reported by the previous 4D computed tomography studies. Individual variations of organ motion in younger patients were due, in part, to changes in respiration rate, which ostensibly reflected the effect of anesthesia. The prediction of organ motion was limited by large individual variations, particularly for older patients. Conclusions: The 4D MRI acquisition method and motion analysis described in this study provide a nonionizing approach to understand age-associated organ motion, which aids in the planning of abdominal radiation therapy for pediatric patients. Use of 4D MRI facilitates monitoring of changes in target motion patterns during treatment courses and in various studies of the effect of organ motion on radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron annihilation characteristics in mesostructural silica films with various porosities

Porous silica films with various porosities were prepared via a sol-gel method using a nonionic amphiphilic triblock copolymer F127 as the structure-directing agent. Doppler broadening of positron annihilation radiation (DBAR) spectra were collected for the prepared films using a variable energy slow positron beam. Different linear relationships between positron annihilation line shape parameters S and W are found for the as-deposited films and calcined ones, indicative of the decomposition of the copolymer porogen in the as-deposited films upon calcination. This also reveals the variation of positron annihilation sites as a function of F127 loading or porosity. Strong correlations between positronium 3γ annihilation fraction, S parameter and porosity of the mesoporous silica films with isolated pores are obtained, which may provide a complementary method to determine closed porosities of mesoporous silica films by DBAR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bronchoscopic Implantation of a Novel Wireless Electromagnetic Transponder in the Canine Lung: A Feasibility Study

Purpose: The success of targeted radiation therapy for lung cancer treatment is limited by tumor motion during breathing. A real-time, objective, nonionizing, electromagnetic localization system using implanted electromagnetic transponders has been developed (Beacon electromagnetic transponder, Calypso Medical Technologies, Inc., Seattle, WA). We evaluated the feasibility and fixation of electromagnetic transponders bronchoscopically implanted in small airways of canine lungs and compared to results using gold markers. Methods and Materials: After approval of the Animal Studies Committee, five mongrel dogs were anesthetized, intubated, and ventilated. Three transponders were inserted into the tip of a plastic catheter, passed through the working channel of a flexible bronchoscope, and implanted into small airways of a single lobe using fluoroscopic guidance. This procedure was repeated for three spherical gold markers in the opposite lung. One, 7, 14, 28, and 60 days postimplantation imaging was used to assess implant fixation. Results: Successful bronchoscopic implantation was possible for 15 of 15 transponders and 12 of 15 gold markers; 3 markers were deposited in the pleural space. Fixation at 1 day was 15 of 15 for transponders and 12 of 12 for gold markers. Fixation at 60 days was 6 of 15 for transponders and 7 of 12 for gold markers, p value = 0.45. Conclusions: Bronchoscopic implantation of both transponders and gold markers into the canine lung is feasible, but fixation rates are low. If fixation rates can be improved, implantable electromagnetic transponders may allow improved radiation therapy for lung cancer by providing real-time continuous target tracking. Developmental work is under way to improve the fixation rates and to reduce sensitivity to implantation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation effects in single-walled carbon nanotube papers

The effects of ionizing radiation on the temperature-dependent conductivity of single-walled carbon nanotube (SWCNT) papers have been investigated in situ in a high vacuum environment. Irradiation of the SWCNT papers with 4.2 MeV alpha particles results in a steady decrease in the SWCNT paper conductivity, resulting in a 25% reduction in room temperature conductivity after a fluence of 3x10{sup 12} alpha particles/cm{sup 2}. The radiation-induced temperature-dependent conductivity modification indicates that radiation damage causes an increase in the effective activation barrier for tunneling-like conductivity and a concomitant increase in wavefunction localization of charge carriers within individual SWCNTs. The spatial defect generation within the SWCNT paper was modeled and confirms that a uniform displacement damage dose was imparted to the paper. This allows the damage coefficient (i.e., differential change in conductivity with fluence) for alpha particles, carbon ions, and protons to be compared with the corresponding nonionizing energy loss (NIEL) of the incident particle. The resulting nonlinear relationship with NIEL between these parameters is distinct from the more typical linear response observed in many bulk semiconductors and superconductors and indicates that localized radiation damage in the SWCNT papers has a greater impact than distributed damage. Although SWCNT papers behave largely as a bulk material with properties that are a convolution of the underlying SWCNT distribution, the radiation response appears to be largely dominated by degradation in the preferred one-dimensional conduction within these two-dimensionally confined nanostructures.

36 MATERIALS SCIENCE↗

Radiation tolerance of a high quality synthetic single crystal chemical vapor deposition diamond detector irradiated by 14.8 MeV neutrons

Diamond exhibits many properties such as an outstanding radiation hardness and fast response time both important to design detectors working in extremely radioactive environments. Among the many applications these devices can be used for, there is the development of a fast and radiation hard neutron detector for the next generation of fusion reactors, such as the International Thermonuclear Experimental Reactor project, under construction at Cadarache in France. A technology to routinely produce electronic grade synthetic single crystal diamond detectors was recently developed by our group. One of such detectors, with an energy resolution of 0.9% as measured using an {sup 241}Am{alpha} particle source, has been heavily irradiated with 14.8 MeV neutrons produced by the Frascati Neutron Generator. The modifications of its spectroscopic properties have been studied as a function of the neutron fluence up to 2.0x10{sup 14} n/cm{sup 2}. In the early stage of the irradiation procedure an improvement in the spectroscopic performance of the detector was observed. Subsequently the detection performance remains stable for all the given neutron fluence up to the final one thus assessing a remarkable radiation hardness of the device. The neutron damage in materials has been calculated and compared with the experimental results. This comparison is discussed within the nonionizing energy loss (NIEL) hypothesis, which states that performance degradation is proportional to NIEL.

36 MATERIALS SCIENCE↗

Detection of radiation induced lung injury in rats using dynamic hyperpolarized {sup 129}Xe magnetic resonance spectroscopy

Purpose: Radiation induced lung injury (RILI) is a common side effect for patients undergoing thoracic radiation therapy (RT). RILI can lead to temporary or permanent loss of lung function and in extreme cases, death. Combining functional lung imaging information with conventional radiation treatment plans may lead to more desirable treatment plans that reduce lung toxicity and improve the quality of life for lung cancer survivors. Magnetic Resonance Imaging of the lung following inhalation of hyperpolarized{sup 129}Xe may provide a useful nonionizing approach for probing changes in lung function and structure associated with RILI before, during, or after RT (early and late time-points). Methods: In this study, dynamic{sup 129}Xe MR spectroscopy was used to measure whole-lung gas transfer time constants for lung tissue and red blood cells (RBC), respectively (T{sub Tr-tissue} and T{sub Tr-RBC}) in groups of rats at two weeks and six weeks following 14 Gy whole-lung exposure to radiation from a {sup 60}Co source. A separate group of six healthy age-matched rats served as a control group. Results: T{sub Tr-tissue} values at two weeks post-irradiation (51.6 ± 6.8 ms) were found to be significantly elevated (p < 0.05) with respect to the healthy control group (37.2 ± 4.8 ms). T{sub Tr-RBC} did not show any significant changes between groups. T{sub Tr-tissue} was strongly correlated with T{sub Tr-RBC} in the control group (r = 0.9601 p < 0.05) and uncorrelated in the irradiated groups. Measurements of arterial partial pressure of oxygen obtained by arterial blood sampling were found to be significantly decreased (p < 0.05) in the two-week group (54.2 ± 12.3 mm Hg) compared to those from a representative control group (85.0 ± 10.0 mm Hg). Histology of a separate group of similarly irradiated animals confirmed the presence of inflammation due to radiation exposure with alveolar wall thicknesses that were significantly different (p < 0.05). At six weeks post-irradiation, T{sub Tr-tissue} returned to values (35.6 ± 9.6 ms) that were not significantly different from baseline. Conclusions: Whole-lung tissue transfer time constants for{sup 129}Xe (T{sub Tr-tissue}) can be used to detect the early phase of RILI in a rat model involving 14 Gy thoracic {sup 60}Co exposure as early as two weeks post-irradiation. This knowledge combined with more sophisticated models of gas exchange and imaging techniques, may allow functional lung avoidance radiation therapy planning to be achievable, providing more beneficial treatment plans and improved quality of life for recovering lung cancer patients.

60 APPLIED LIFE SCIENCES↗

The use of displacement damage dose to correlate degradation in solar cells exposed to different radiations

It has been found useful in the past to use the concept of 'equivalent fluence' to compare the radiation response of different solar cell technologies. Results are usually given in terms of an equivalent 1 MeV electron or an equivalent 10 MeV proton fluence. To specify cell response in a complex space-radiation environment in terms of an equivalent fluence, it is necessary to measure damage coefficients for a number of representative electron and proton energies. However, at the last Photovoltaic Specialist Conference we showed that nonionizing energy loss (NIEL) could be used to correlate damage coefficients for protons, using measurements for GaAs as an example. This correlation means that damage coefficients for all proton energies except near threshold can be predicted from a measurement made at one particular energy. NIEL is the exact equivalent for displacement damage of linear energy transfer (LET) for ionization energy loss. The use of NIEL in this way leads naturally to the concept of 10 MeV equivalent proton fluence. The situation for electron damage is more complex, however. It is shown that the concept of 'displacement damage dose' gives a more general way of unifying damage coefficients. It follows that 1 MeV electron equivalent fluence is a special case of a more general quantity for unifying electron damage coefficients which we call the 'effective 1 MeV electron equivalent dose'.

Summers, Geoffrey P.↗

Electromagnetic field interactions with the human body: Observed effects and theories

The effects of nonionizing electromagnetic (EM) field interactions with the human body were reported and human related studies were collected. Nonionizing EM fields are linked to cancer in humans in three different ways: cause, means of detection, and effective treatment. Bad and benign effects are expected from nonionizing EM fields and much more knowledge is necessary to properly categorize and qualify EM field characteristics. It is concluded that knowledge of the boundary between categories, largely dependent on field intensity, is vital to proper future use of EM radiation for any purpose and the protection of the individual from hazard.

Raines, J. K.↗

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady Nuclear Combustion in Rockets

The astrophysical theory of stationary nuclear reactions in stars is applied to the conditions that would be met in the practical engineering cases that would differ from the former, particularly with respect to the much lower combustion pressures, dimensions of the reacting volume, and burnup times. This application yields maximum rates of hear production per unit volume of reacting gas occurring at about 10(exp 8) K in the cases of reactions between the hydrogen isotopes, but yields higher rates for heavier atoms. For the former, with chamber pressures of the order of 100 atmospheres, the energy production for nuclear combustion reaches values of about 10(exp 4) kilocalories per cubic meter per second, which approaches the magnitude for the familiar chemical fuels. The values are substantially lower for heavier atoms, and increase with the square of the combustion pressure. The half-life of the burnup in the fastest reactions may drop to values as low as those for chemical fuels so that, despite the high temperature, the radiated energy can remain smaller than the energy produced, particularly if an inefficiently radiating (i.e., easily completely ionized reacting material like hydrogen), is used. On the other hand, the fraction of completely ionized particles in the gases undergoing nuclear combustion must not exceed a certain upper limit because the densities (approximately 10(exp -10) grams per cubic centimeter)) lie in the range of high vacua and only for the previously mentioned fraction of nonionized particles can mean free paths be retained small enough so that the chamber diameters of several dozen meters will suffice. Under these conditions it appears that continuously maintained stable nuclear reactions at practical pressures and dimensions are fundamentally possible and their application can be visualized as energy sources for power plants and propulsion units.

Saenger, E.↗