Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of Node-Centered and Cell-Centered Unstructured Finite-Volume Discretizations: Viscous Fluxes - Part 1

Discretization of the viscous terms in current finite-volume unstructured-grid schemes are compared using node-centered and cell-centered approaches in two dimensions. Accuracy and efficiency are studied for six nominally second-order accurate schemes: a node-centered scheme, cell-centered node-averaging schemes with and without clipping, and cell-centered schemes with unweighted, weighted, and approximately mapped least-square face gradient reconstruction. The grids considered range from structured (regular) grids to irregular grids composed of arbitrary mixtures of triangles and quadrilaterals, including random perturbations of the grid points to bring out the worst possible behavior of the solution. Two classes of tests are considered. The first class of tests involves smooth manufactured solutions on both isotropic and highly anisotropic grids with discontinuous metrics, typical of those encountered in grid adaptation. The second class concerns solutions and grids varying strongly anisotropically over a curved body, typical of those encountered in high-Reynolds number turbulent flow simulations. Results from the first class indicate the face least-square methods, the node-averaging method without clipping, and the node-centered method demonstrate second-order convergence of discretization errors with very similar accuracies per degree of freedom. The second class of tests are more discriminating. The node-centered scheme is always second order with an accuracy and complexity in linearization comparable to the best of the cell-centered schemes. In comparison, the cell-centered node-averaging schemes are less accurate, have a higher complexity in linearization, and can fail to converge to the exact solution when clipping of the node-averaged values is used. The cell-centered schemes using least-square face gradient reconstruction have more compact stencils with a complexity similar to the complexity of the node-centered scheme. For simulations on highly anisotropic curved grids, the least-square methods have to be amended either by introducing a local mapping of the surface anisotropy or modifying the scheme stencil to reflect the direction of strong coupling.

Diskin, Boris↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

The purpose of the pressurization system in liquid rocket propulsion is to control the pressure in the gas space of the propellant tank (known as the ullage space) and the propellant mass flowrate to the engine. A mathematical model is required to predict the amount of pressurant necessary to ensure that pressure and temperature levels inside the tank remain within acceptable limits and that the propellant pressure leaving the tank satisfies the net positive suction pressure (NPSP) requirement of the pump feeding the engine. Nodal codes typically model tank pressurization and draining using a single node to represent the ullage and a single node to represent the propellant. As the tank drains, the ullage node grows and the propellant node shrinks. The heat transfer between ullage to wall and ullage to propellant is governed by natural convection. Designers of liquid propulsion systems often use empirical correlations to estimate the “Collapse Factor” which represents the ratio of pressurant required with heat transfer and the amount of pressurant required without heat transfer. A single node ullage model of tank pressurization was developed using GFSSP to compute the collapse factor reasonably well and later was used to model tank pressurization during test firing of the FASTRAC rocket engine. The predicted tank pressure compared well with the test data. In the early 1970’s, pressurization and drain tests with liquid methane were performed at NASA Lewis Research Center in a vacuum chamber. A 5 ft diameter spherical aluminum tank was tested to drain from 95% to 5% full using gaseous helium, hydrogen, nitrogen and methane as pressurant. Tests were conducted with different pressurant inlet temperatures and drain times. Measured data include pressurant requirement, amount of pressurant condensed, and ullage and wall temperatures at various heights in the ullage space at the end of draining. A single node GFSSP model was developed to simulate helium pressurization of the methane tank. Predicted helium consumption was 8-23% less than measured. The average error of the six test cases was 16%. A single ullage node with multiple solid node model was developed using Thermal Desktop. Predicted helium consumption compares with the test data within 2%. This paper describes the development of a GFSSP multi-node ullage model of the test configuration and compares the predicted pressurant consumption for both helium and autogenous pressurization using gaseous methane with experimental as well as TD predictions.

Nodal Model↗

Space physics analysis network node directory (The Yellow Pages): Fourth edition

The Space Physics Analysis Network (SPAN) is a component of the global DECnet Internet, which has over 17,000 host computers. The growth of SPAN from its implementation in 1981 to its present size of well over 2,500 registered SPAN host computers, has created a need for users to acquire timely information about the network through a central source. The SPAN Network Information Center (SPAN-NIC) an online facility managed by the National Space Science Data Center (NSSDC) was developed to meet this need for SPAN-wide information. The remote node descriptive information in this document is not currently contained in the SPAN-NIC database, but will be incorporated in the near future. Access to this information is also available to non-DECnet users over a variety of networks such as Telenet, the NASA Packet Switched System (NPSS), and the TCP/IP Internet. This publication serves as the Yellow Pages for SPAN node information. The document also provides key information concerning other computer networks connected to SPAN, nodes associated with each SPAN routing center, science discipline nodes, contacts for primary SPAN nodes, and SPAN reference information. A section on DECnet Internetworking discusses SPAN connections with other wide-area DECnet networks (many with thousands of nodes each). Another section lists node names and their disciplines, countries, and institutions in the SPAN Network Information Center Online Data Base System. All remote sites connected to US-SPAN and European-SPAN (E-SPAN) are indexed. Also provided is information on the SPAN tail circuits, i.e., those remote nodes connected directly to a SPAN routing center, which is the local point of contact for resolving SPAN-related problems. Reference material is included for those who wish to know more about SPAN. Because of the rapid growth of SPAN, the SPAN Yellow Pages is reissued periodically.

Peters, David J.↗

Protocol for multiple node network

The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs an antibody recognition message termination process performed by all remote nodes and a remote node polling process performed by other nodes which are master units controlling remote nodes in respective zones of the network assigned to respective master nodes. Each remote node repeats only those messages originated in the local zone, to provide isolation among the master nodes.

Kirkham, Harold↗

Protocol for multiple node network

The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs an antibody recognition message termination process performed by all remote nodes and a remote node polling process performed by other nodes which are master units controlling remote nodes in respective zones of the network assigned to respective master nodes. Each remote node repeats only those messages originated in the local zone, to provide isolation among the master nodes.

Kirkham, Harold↗

A 4-node assumed-stress hybrid shell element with rotational degrees of freedom

An assumed-stress hybrid/mixed 4-node quadrilateral shell element is introduced that alleviates most of the deficiencies associated with such elements. The formulation of the element is based on the assumed-stress hybrid/mixed method using the Hellinger-Reissner variational principle. The membrane part of the element has 12 degrees of freedom including rotational or drilling degrees of freedom at the nodes. The bending part of the element also has 12 degrees of freedom. The bending part of the element uses the Reissner-Mindlin plate theory which takes into account the transverse shear contributions. The element formulation is derived from an 8-node isoparametric element. This process is accomplished by assuming quadratic variations for both in-plane and out-of-plane displacement fields and linear variations for both in-plane and out-of-plane rotation fields along the edges of the element. In addition, the degrees of freedom at midside nodes are approximated in terms of the degrees of freedom at corner nodes. During this process the rotational degrees of freedom at the corner nodes enter into the formulation of the element. The stress field are expressed in the element natural-coordinate system such that the element remains invariant with respect to node numbering.

Aminpour, Mohammad A.↗

High speed polling protocol for multiple node network

The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs a remote node polling process performed by a master node by transmitting a polling message generically addressed to all remote nodes associated with the master node. Each remote node responds upon receipt of the generically addressed polling message by transmitting a poll-answering informational message and by relaying the polling message to other adjacent remote nodes.

Kirkham, Harold↗

Comparison of Node-Centered and Cell-Centered Unstructured Finite-Volume Discretizations: Inviscid Fluxes

Cell-centered and node-centered approaches have been compared for unstructured finite-volume discretization of inviscid fluxes. The grids range from regular grids to irregular grids, including mixed-element grids and grids with random perturbations of nodes. Accuracy, complexity, and convergence rates of defect-correction iterations are studied for eight nominally second-order accurate schemes: two node-centered schemes with weighted and unweighted least-squares (LSQ) methods for gradient reconstruction and six cell-centered schemes two node-averaging with and without clipping and four schemes that employ different stencils for LSQ gradient reconstruction. The cell-centered nearest-neighbor (CC-NN) scheme has the lowest complexity; a version of the scheme that involves smart augmentation of the LSQ stencil (CC-SA) has only marginal complexity increase. All other schemes have larger complexity; complexity of node-centered (NC) schemes are somewhat lower than complexity of cell-centered node-averaging (CC-NA) and full-augmentation (CC-FA) schemes. On highly anisotropic grids typical of those encountered in grid adaptation, discretization errors of five of the six cell-centered schemes converge with second order on all tested grids; the CC-NA scheme with clipping degrades solution accuracy to first order. The NC schemes converge with second order on regular and/or triangular grids and with first order on perturbed quadrilaterals and mixed-element grids. All schemes may produce large relative errors in gradient reconstruction on grids with perturbed nodes. Defect-correction iterations for schemes employing weighted least-square gradient reconstruction diverge on perturbed stretched grids. Overall, the CC-NN and CC-SA schemes offer the best options of the lowest complexity and secondorder discretization errors. On anisotropic grids over a curved body typical of turbulent flow simulations, the discretization errors converge with second order and are small for the CC-NN, CC-SA, and CC-FA schemes on all grids and for NC schemes on triangular grids; the discretization errors of the CC-NA scheme without clipping do not converge on irregular grids. Accurate gradient reconstruction can be achieved by introducing a local approximate mapping; without approximate mapping, only the NC scheme with weighted LSQ method provides accurate gradients. Defect correction iterations for the CC-NA scheme without clipping diverge; for the NC scheme with weighted LSQ method, the iterations either diverge or converge very slowly. The best option in curved geometries is the CC-SA scheme that offers low complexity, second-order discretization errors, and fast convergence.

Diskin, Boris↗

PVM Enhancement for Beowulf Multiple-Processor Nodes

A recent version of the Parallel Virtual Machine (PVM) computer program has been enhanced to enable use of multiple processors in a single node of a Beowulf system (a cluster of personal computers that runs the Linux operating system). A previous version of PVM had been enhanced by addition of a software port, denoted BEOLIN, that enables the incorporation of a Beowulf system into a larger parallel processing system administered by PVM, as though the Beowulf system were a single computer in the larger system. BEOLIN spawns tasks on (that is, automatically assigns tasks to) individual nodes within the cluster. However, BEOLIN does not enable the use of multiple processors in a single node. The present enhancement adds support for a parameter in the PVM command line that enables the user to specify which Internet Protocol host address the code should use in communicating with other Beowulf nodes. This enhancement also provides for the case in which each node in a Beowulf system contains multiple processors. In this case, by making multiple references to a single node, the user can cause the software to spawn multiple tasks on the multiple processors in that node.

Springer, Paul↗

Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

Monacos, Steve P.↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

Pressurized expulsion tests of liquid methane were modeled by a nodal code using a multinode ullage approach. Generalized Fluid System Simulation Program (GFSSP), a finite volume based nodal code was used to model the expulsion of liquid methane from a 1.52-meter (5 ft) diameter spherical tank by pressurizing with helium and gaseous methane. The purpose of the model was to estimate the amount of pressurant required and amount of condensation and evaporation of methane during the operation. The ullage was discretized into multiple nodes and each fluid node was connected to solid nodes. Both the fluid and solid nodes grow as the tank drains. The heat and mass transfer between fluid and solid node in the tank ullage was computed. The heat and mass transfer between the bottom ullage node and the liquid methane was also computed. The model predictions were compared with data from twelve test cases. The predicted pressurant consumption for helium pressurization compares with test data with a Mean Absolute Percent Error (MAPE) of 3 %. For autogenous pressurization, where gaseous methane was used to pressurize liquid methane, the predicted pressurant consumption compares with a MAPE of 6%.

Cryogenic Propellant↗

Nodal Modeling of Helium Pressurization and Autogenous Pressurization and Draining using a Multi-Node-Ullage Approach

Pressurized expulsion tests of liquid methane were modeled by a nodal code using a multinode ullage approach. Generalized Fluid System Simulation Program (GFSSP), a finite volume based nodal code was used to model the expulsion of liquid methane from a 1.52-meter (5 ft) diameter spherical tank by pressurizing with helium and gaseous methane. The purpose of the model was to estimate the amount of pressurant required and amount of condensation and evaporation of methane during the operation. The ullage was discretized into multiple nodes and each fluid node was connected to solid nodes. Both the fluid and solid nodes grow as the tank drains. The heat and mass transfer between fluid and solid node in the tank ullage was computed. The heat and mass transfer between the bottom ullage node and the liquid methane was also computed. The model predictions were compared with data from twelve test cases. The predicted pressurant consumption for helium pressurization compares with test data with a Mean Absolute Percent Error (MAPE) of 3%. For autogenous pressurization, where gaseous methane was used to pressurize liquid methane, the predicted pressurant consumption compares with a MAPE of 6%.

Nodal Model↗

Nodes packaging option for Space Station application

Space Station nodes packaging analyses are presented relative to moving environmental control and life support system (ECLSS) equipment from the habitability (HAB) module to node 4, in order to provide more living space and privacy for the crew, remove inherently noisy equipment from the crew quarter, retain crew waste collection and processing equipment in one location, and keep objectionable odor away from the living quarters. In addition, options for moving external electronic equipment from the Space Station truss to pressurized node 3 were evaluated in order to reduce the crew extravehicular-activity time required to install and maintain the equipment. Node size considered in this analysis is 3.66 m in diameter and 5.38 m long. The analysis shows that significant external electronic equipment could be relocated from the Space Station truss structure to node 3, and nonlife critical ECLSS HAB module equipment could be moved to node 4.

So, Kenneth T.↗

Morphological study of the innervation pattern of the rabbit sinoatrial node

The pattern of sinoatrial (SA) node innervations in rabbit was elucidated using a newly developed highly reproducible cholinesterase/silver impregnation staining procedure which made it possible to delineate large nerves, fine processes, and ganglion cells. The SA node and dominant pacemaker sites were identified by microelectrode recording. A generalized pattern of innnervation was recognized, which includes a large ganglionic complex inferior to the SA node; two or more moderately large nerves traversing the SA node parallel to the crista terminalis; nerves entering the intercaval region from the septum, the superior vena cava, and the inferior vena cava to impinge on the SA node; and a fine network of nerve processes, which was particularly dense in the SA node. From the location and distribution of the nerves and ganglionic branches, it can be inferred that the neural network in the intercaval region is capable of performing complex modulatory and integrative functions among the structures within this region.

Roberts, L. A.↗

Exploring the use of I/O nodes for computation in a MIMD multiprocessor

As parallel systems move into the production scientific-computing world, the emphasis will be on cost-effective solutions that provide high throughput for a mix of applications. Cost effective solutions demand that a system make effective use of all of its resources. Many MIMD multiprocessors today, however, distinguish between 'compute' and 'I/O' nodes, the latter having attached disks and being dedicated to running the file-system server. This static division of responsibilities simplifies system management but does not necessarily lead to the best performance in workloads that need a different balance of computation and I/O. Of course, computational processes sharing a node with a file-system service may receive less CPU time, network bandwidth, and memory bandwidth than they would on a computation-only node. In this paper we begin to examine this issue experimentally. We found that high performance I/O does not necessarily require substantial CPU time, leaving plenty of time for application computation. There were some complex file-system requests, however, which left little CPU time available to the application. (The impact on network and memory bandwidth still needs to be determined.) For applications (or users) that cannot tolerate an occasional interruption, we recommend that they continue to use only compute nodes. For tolerant applications needing more cycles than those provided by the compute nodes, we recommend that they take full advantage of both compute and I/O nodes for computation, and that operating systems should make this possible.

Kotz, David↗

Neural node network and model, and method of teaching same

The present invention is a fully connected feed forward network that includes at least one hidden layer 16. The hidden layer 16 includes nodes 20 in which the output of the node is fed back to that node as an input with a unit delay produced by a delay device 24 occurring in the feedback path 22 (local feedback). Each node within each layer also receives a delayed output (crosstalk) produced by a delay unit 36 from all the other nodes within the same layer 16. The node performs a transfer function operation based on the inputs from the previous layer and the delayed outputs. The network can be implemented as analog or digital or within a general purpose processor. Two teaching methods can be used: (1) back propagation of weight calculation that includes the local feedback and the crosstalk or (2) more preferably a feed forward gradient decent which immediately follows the output computations and which also includes the local feedback and the crosstalk. Subsequent to the gradient propagation, the weights can be normalized, thereby preventing convergence to a local optimum. Education of the network can be incremental both on and off-line. An educated network is suitable for modeling and controlling dynamic nonlinear systems and time series systems and predicting the outputs as well as hidden states and parameters. The educated network can also be further educated during on-line processing.

Parlos, Alexander G.↗

High speed polling protocol for multiple node network with sequential flooding of a polling message and a poll-answering message

The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs a remote node polling process performed by a master node by transmitting a polling message generically addressed to all remote nodes associated with the master node. Each remote node responds upon receipt of the generically addressed polling message by sequentially flooding the network with a poll-answering informational message and with the polling message.

Marvit, Maclen↗

Modification of the International Space Station USOS to Support Installation and Activation of the Node 3 Element

The International Space Station (ISS) program is nearing an assembly complete configuration with the addition of the final resource node module in early 2010. The Node 3 module will provide critical functionality in support of permanent long duration crews aboard ISS. The new module will permanently house the regenerative Environment Control and Life Support Systems (ECLSS) and will also provide important habitability functions such as waste management and exercise facilities. The ISS program has selected the Port side of the Node 1 "Unity" module as the permanent location for Node 3 which will necessitate architecture changes to provide the required interfaces. The USOS ECLSS fluid and ventilation systems, Internal Thermal Control Systems, and Avionics Systems require significant modifications in order to support Node 3 interfaces at the Node 1 Port location since it was not initially designed for that configuration. This paper outlines the design, development, certification, and implementation of these changes in support of ISS assembly complete.

Link, Dwight E., Jr.↗