Search for nonreciprocal magnons in MnPS 3

Recent articles have suggested that the quasi-two-dimensional antiferromagnet MnPS 3 may have nonreciprocal magnons, whereby magnons in a Brillouin zone corner at + q have different energies than those at q . The magnons along the Brillouin zone boundaries were measured using neutron three-axis spectrometry, paying careful attention to the resolution function, to determine whether such nonreciprocity was present. The data show that, within the resolution, there are no significant differences between the magnons in opposite Brillouin zone corners. The findings are combined with a recently published study of MnPS 3 by neutron resonant spin-echo spectroscopy and discussed within the context of the theories for nonreciprocal magnons.

2-dimensional systems↗

Influence of Grafting Density and the Ionic Environment on the Structure of Zwitterionic Brushes

Zwitterionic polymer brushes possess a high potential for applications as surface coatings, e.g., in antifouling applications. Their complex association behavior due to the coexistence of oppositely charged groups on the same monomeric unit allows for a broad variation of polarity, hydrophilicity, and the antipolyelectrolyte effect with the variation of the surrounding environment. In this study, planar polysulfobetaine brushes were investigated with neutron reflectometry (NR) and neutron spin–echo spectroscopy under grazing incidence (GINSES) to explore the brush structure and its inner dynamics perpendicular to the substrate. In particular, the effects of the substrate–initiator system and ionic strength on the structure were investigated with neutron reflectometry and a swelling by a factor of 3–5 was found in the presence of aqueous NaCl and MgCl 2 solutions compared to the dry state. During the data analysis, the applicability of a model-free evaluation was also demonstrated for the investigated polysulfobetaine brushes. Furthermore, it was found with GINSES that in contrast to neutral brushes, these polysulfobetaine brushes do not show the typical concentration fluctuations in the nanosecond time range when partially swollen with salt-free water.

36 MATERIALS SCIENCE↗

Design and performance of a superconducting neutron resonance spin flipper

Despite the challenges, neutron resonance spin echo still holds the promise to improve upon neutron spin echo for the measurement of slow dynamics in materials. We present a bootstrap, radio frequency neutron spin flipper using high temperature superconducting technology capable of flipping neutron spin with either nonadiabatic or adiabatic modes. A frequency of 2 MHz has been achieved, which would achieve an effective field integral of 0.35 T m for a meter of separation in a neutron resonance spin echo spectrometer at the current device specifications. In bootstrap mode, the self-cancellation of Larmor phase aberrations can be achieved with the appropriate selection of the polarity of the gradient coils.

47 OTHER INSTRUMENTATION↗

Intermediate scattering functions of a rigid body monoclonal antibody protein in solution studied by dissipative particle dynamic simulation

In the past decade, there was increased research interest in studying internal motions of flexible proteins in solution using Neutron Spin Echo (NSE) as NSE can simultaneously probe the dynamics at the length and time scales comparable to protein domain motions. However, the collective intermediate scattering function (ISF) measured by NSE has the contributions from translational, rotational, and internal motions, which are rather complicated to be separated. Widely used NSE theories to interpret experimental data usually assume that the translational and rotational motions of a rigid particle are decoupled and independent to each other. To evaluate the accuracy of this approximation for monoclonal antibody (mAb) proteins in solution, dissipative particle dynamic computer simulation is used here to simulate a rigid-body mAb for up to about 200 ns. The total ISF together with the ISFs due to only the translational and rotational motions as well as their corresponding effective diffusion coefficients is calculated. The aforementioned approximation introduces appreciable errors to the calculated effective diffusion coefficients and the ISFs. For the effective diffusion coefficient, the error introduced by this approximation can be as large as about 10% even though the overall agreement is considered reasonable. Thus, we need to be cautious when interpreting the data with a small signal change. In addition, the accuracy of the calculated ISFs due to the finite computer simulation time is also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Alpha-relaxation by scattering and medium-range atomic correlation in simple liquids

The relaxation dynamics of liquid and glass can be studied by inelastic x-ray or neutron scattering through the intermediate scattering function F(Q, t), where Q is the momentum transfer of scattering. Because of the time-consuming nature of these measurements, F(Q, t) is usually measured only at the first peak of the structure function S(Q), and its principal decay time is referred to as the α-relaxation time τ α . τ α is generally considered to describe the relaxation time of the bulk, which is related to viscosity and is controlled by the atomic cage around an atom. Here, through simulations on metallic liquids, we show that the α-relaxation time determined by scattering experiments does not purely reflect viscosity but is influenced by changes in spatial cooperativity. We also demonstrate that atomic caging is not exerted by the nearest neighbors but involves more cooperative atomic dynamics of the atomic medium-range order.

Glass transitions↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Protein Dynamics via Neutron Spin Echo Spectroscopy

Most human body proteins' activity and functionality are related to configurational changes of entire subdomains within the protein crystal structure. The crystal structures build the basis for any calculation that describes the structure or dynamics of a protein, most of the time with strong geometrical restrictions. However, these restrictions from the crystal structure are not present in the solution. The structure of the proteins in the solution may differ from the crystal due to rearrangements of loops or subdomains on the pico to nanosecond time scale (i.e., the internal protein dynamics time regime). This study describes how slow motions on timescales of several tens of nanoseconds can be accessed using neutron scattering. In particular, the dynamical characterization of two major human proteins, an intrinsically disordered protein that lacks a well-defined secondary structure and a classical antibody protein, is addressed by neutron spin echo spectroscopy (NSE) combined with a wide range of laboratory characterization methods. Further insights into protein domain dynamics were achieved using mathematical modeling to describe the experimental neutron data and determine the crossover between combined diffusive and internal protein motions. The extraction of the internal dynamic contribution to the intermediate scattering function obtained from NSE, including the timescale of the various movements, allows further vision into the mechanical properties of single proteins and the softness of proteins in their nearly natural environment in the crowded protein solution.

59 BASIC BIOLOGICAL SCIENCES↗

Different agglomeration properties of PC 61 BM and PC 71 BM in photovoltaic inks – a spin-echo SANS study

Fullerene derivatives are used in a wide range of applications including as electron acceptors in solution-processable organic photovoltaics. We report agglomeration of fullerene derivatives in optically opaque solutions of PC 61 BM and PC 71 BM, with concentrations ranging from 30 mg mL -1 up to 90 mg mL -1 , in different solvents with relevance to organic photovoltaics, using a novel neutron scattering technique, Spin-Echo Small Angle Neutron Scattering (SESANS). From SESANS, agglomerates with correlation lengths larger than 1 μm are found in some PC 61 BM solutions, in contrast no agglomerates are seen in PC 71 BM solutions. These results clearly show that PC 71 BM is fundamentally more soluble than PC 61 BM in the solvents commonly used in photovoltaic inks and corroborating similar observations previously achieved using other experimental techniques. Computer models are presented to study the energetics of solution and agglomeration of both species, ascribing the difference to a kinetic effect probably related to the larger anisotropy of PC 71 BM. Also, this work showcases the power of SESANS to probe agglomerates of fullerene derivatives in completely opaque solutions for agglomerates of the order of one to several microns.

36 MATERIALS SCIENCE↗

Topological shaping of vortex neutron beams using forked phase gratings

Beams of light or matter that carry well-defined states of orbital angular momentum (OAM) are promising probes of topological and textured condensed matter systems such as magnetic skyrmions. Using spin-echo small-angle neutron scattering, a phase-sensitive technique that allows for a relatively low intensity beam, we demonstrate the production of vortex neutron beams from forked phase gratings of various topological charges. This type of interferometric verification of OAM we present here could be further extended to other platforms using probes that are similarly limited by the coherence and strength of the currently available sources.

Cold atoms & matter waves↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

Spin-textured neutron beams with orbital angular momentum

In this work, we present a rigorous theoretical framework underpinning the technique of spin-echo modulated small-angle neutron scattering (SEMSANS), and show how the technique can be extended in order to generate spin-textured neutron beams with orbital angular momentum (OAM) via birefringent neutron spin-polarization devices known as magnetic Wollaston prisms. Neutron OAM beams are mathematically characterized by a “cork-screw” phase singularity e iℓΦ about the propagation axis where ℓ is the OAM quantum number. To understand the precise relationship between the emergent OAM state and the variety of spin textures realized by various setups, we have developed a path-integral approach that in the interferometric limit makes a judicious use of magnetic Snell's law. We show that our proposed technique produces a complex two-dimensional pattern of spin-OAM entangled states which may be useful as a probe of quantum magnetic materials. We compare our path-integral approach to the well-known single-path Larmor precession model and present a pedagogical derivation of magnetic Snell's law of refraction for both massive and massless particles based on Maupertuis's action principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended flexibility of neutron Larmor diffraction for increased diffraction range in mosaicity measurements

Larmor diffraction (LD) is a neutron scattering technique that offers enhanced resolution by harnessing the Larmor precession of neutron spins in a magnetic field. By encoding subtle changes in neutron momentum transfer into significant alterations in the Larmor phase of neutron spins, LD can be employed to measure lattice expansion, lattice distortion, and mosaicity with exceptional resolution. As originally proposed by Rekveldt et al., LD necessitates the magnetic field boundaries to be tilted to be parallel to the crystal plane of interest. Here, this report explores the fundamental principles shared between LD and spin-echo small-angle neutron scattering (SESANS). Drawing inspiration from the flexibility of SESANS to adjust magnetic field boundaries to optimize the resolution in the measurement of the neutron momentum transfers q, we will demonstrate that the strict requirement of parallel alignment between the magnetic field boundaries and the crystal plane can be relaxed for the measurements of mosaicity. Such relaxation will expand the accessible diffraction angles for these situations that are highly constrained.

Larmor diffraction↗

15 years of spin-echo spectroscopy at SNS-NSE: Looking back and looking forward

High-resolution neutron spin echo (NSE) spectroscopy offers unique insights into the mobility of molecular (sub)structures excited by thermal fluctuations (i.e., Brownian motion) of “soft matter” as polymers in solution and in the melt, in biological matter (e.g., protein motions), membranes, and glasses. The ability to tag substructures using H, D contrast variation to resolve the relevant timescales of dynamics on selected molecular items in liquids, soft matter, and melts is a significant advantage of NSE. Also slow magnetic fluctuations on molecular length scales in the range of nanoseconds, e.g., in spin glasses or topological spin structures, can be accessed. This paper reviews the highlights and peculiarities of the SNS-NSE, based at the pulsed neutron source SNS, during its first 1.5 decades of operation. An outlook and perspectives of research in the domain of high-resolution spectroscopy is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-flight modulated intensity small-angle neutron scattering measurement of the self-diffusion constant of water

We report that the modulated intensity by zero effort small-angle neutron scattering (MI-SANS) technique is used to measure scattering with a high energy resolution on samples normally ill-suited for neutron resonance spin echo. The self-diffusion constant of water is measured over a q–t range of 0.01–0.2 Å -1 and 70–500 ps. In addition to demonstrating the methodology of using time-of-flight MI-SANS instruments to observe diffusion in liquids, the results support previous measurements on water performed with different methods. This polarized neutron technique simultaneously measures the intermediate scattering function for a wide range of time and length scales. Two radio frequency flippers were used in a spin-echo setup with a 100 kHz frequency difference in order to create a high-resolution time measurement. The results are compared with self-diffusion measurements made by other techniques and the general applicability of MI-SANS at a pulsed source is assessed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗