Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron generators.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cylindrical neutron generator

A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

07 ISOTOPE AND RADIATION SOURCES↗

Cylindrical neutron generator

A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short pulse neutron generator

Short pulse neutron generators are described herein. In a general embodiment, the short pulse neutron generator includes a Blumlein structure. The Blumlein structure includes a first conductive plate, a second conductive plate, a third conductive plate, at least one of an inductor or a resistor, a switch, and a dielectric material. The first conductive plate is positioned relative to the second conductive plate such that a gap separates these plates. A vacuum chamber is positioned in the gap, and an ion source is positioned to emit ions in the vacuum chamber. The third conductive plate is electrically grounded, and the switch is operable to electrically connect and disconnect the second conductive plate and the third conductive plate. The at least one of the resistor or the inductor is coupled to the first conductive plate and the second conductive plate.

43 PARTICLE ACCELERATORS↗

Short pulse neutron generator

Short pulse neutron generators are described herein. In a general embodiment, the short pulse neutron generator includes a Blumlein structure. The Blumlein structure includes a first conductive plate, a second conductive plate, a third conductive plate, at least one of an inductor or a resistor, a switch, and a dielectric material. The first conductive plate is positioned relative to the second conductive plate such that a gap separates these plates. A vacuum chamber is positioned in the gap, and an ion source is positioned to emit ions in the vacuum chamber. The third conductive plate is electrically grounded, and the switch is operable to electrically connect and disconnect the second conductive plate and the third conductive plate. The at least one of the resistor or the inductor is coupled to the first conductive plate and the second conductive plate.

Elizondo-Decanini, Juan M.↗

Note: Coincidence measurements of 3 He and neutrons from a compact D-D neutron generator

Tagging of neutrons (2.45 MeV) with their associated 3He particles from deuterium-deuterium (D-D) fusion reactions has been demonstrated in a compact neutron generator setup enabled by a high brightness, microwave-driven ion source with a high fraction of deuterons. Energy spectra with well separated peaks of the D-D fusion reaction products, 3 He, tritons, and protons, were measured with a silicon PIN diode. The neutrons were detected using a liquid scintillator detector with pulse shape discrimination. In this work, by correlating the 3 He detection events with the neutron detection in time, we demonstrated the tagging of emitted neutrons with 3 He particles detected with a Si PIN diode detector mounted inside the neutron generator vacuum vessel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source and beam guiding studies for an API neutron generator

Recently developed neutron imaging methods require high neutron yields for fast imaging times and small beam widths for good imaging resolution. For ion sources with low current density to be viable for these types of imaging methods, large extraction apertures and beam focusing must be used. We present recent work on the optimization of a Penning-type ion source for neutron generator applications. Two multi-cusp magnet configurations have been tested and are shown to increase the extracted ion current density over operation without multi-cusp magnetic fields. The use of multi-cusp magnetic confinement and gold electrode surfaces have resulted in increased ion current density, up to 2.2 mA/cm{sup 2}. Passive beam focusing using tapered dielectric capillaries has been explored due to its potential for beam compression without the cost and complexity issues associated with active focusing elements. Initial results from first experiments indicate the possibility of beam compression. Further work is required to evaluate the viability of such focusing methods for associated particle imaging (API) systems.

43 PARTICLE ACCELERATORS↗

Monitoring Neutron Generator Output in a Mixed Neutron-Gamma Field Using a Plastic Scintillator.

Quantitative neutron-induced gamma-ray spectroscopy employing neutron generators (NGs) entails monitoring them for possible fluctuations in their neutron output. We accomplished this using a plastic scintillator and recording a spectrum from which we selected a neutron region-of-interest (nROI) to discriminate between neutrons and the accompanying high-energy gamma-rays. We show that the selected nROI is insensitive to changes in the gamma-ray background, thus allowing satisfactory normalization of the gamma-ray spectra of an in-situ system for analyzing soil carbon.

54 ENVIRONMENTAL SCIENCES↗

The DD Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Uranium Neutron Coincidence Collar

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques because of the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Coincidence Collar (UNCL), and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every 5–7 years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. Previously we examined the performance of Oak Ridge National Laboratory’s Large Volume Active Well Coincidence Counter modified to accept a commercially available deuterium-deuterium (DD) neutron generator to examine the potential of the DD neutron generator as an alternative to the isotopic sources [1]. That work indicated that the DD generator was a viable replacement for the AWCC applications, but because of the large dimensions of that generator, the DD/AWCC would have to be run as a delayed neutron counting system to provide equivalent measurement precision. In this work we examine the performance of a standard UNCL modified to accept the DD neutron generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium and highly enriched uranium items. The projected performance of the modified UNCL for fresh pressurized water reactor fuel assemblies operated in both traditional coincidence counting and delayed neutron counting modes is presented.

07 ISOTOPE AND RADIATION SOURCES↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Evaluation of the Starfire nGen-350 DD Neutron Generator for use with the Fast Neutron Coincidence Collar

The Starfire Industries nGen-350 DD neutron generator has been developed for use with the Fast Neutron Coincidence Collar (FNCL). The generator was adapted from the nGen-310 model generator by Starfire to accommodate an International Atomic Energy Agency (IAEA) request to incorporate a neutron yield stabilization mechanism. An nGen-350 generator was obtained by Oak Ridge National Laboratory (ORNL) for evaluation as a potential neutron interrogation source replacement for Am(Li) in the FNCL. This report provides a summary of the performance of the nGen-350.

43 PARTICLE ACCELERATORS↗

Negative ion-driven associated particle neutron generator

We describe an associated particle neutron generator that employs a negative ion source to produce high neutron flux from a small source size. Furthermore, negative ions produced in an rf-driven plasma source are extracted through a small aperture to form a beam which bombards a positively biased, high voltage target electrode. Electrons co-extracted with the negative ions are removed by a permanent magnet electron filter. The use of negative ions enables high neutron output (100% atomic ion beam), high quality imaging (small neutron source size), and reliable operation (no high voltage breakdowns). Finally, the neutron generator can operate in either pulsed or continuous-wave (cw) mode and has been demonstrated to produce 10 6 D-D n/s (equivalent to similar to 10 8 D-T n/s) from a 1 mm-diameter neutron source size to facilitate high fidelity associated particle imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Pulsing Neutron Generators for Security Application

Active neutron interrogation has been demonstrated to be an effective method of detecting shielded fissile material. A fast fall-time/fast pulsing neutron generator is needed primarily for differential die-away technique (DDA) interrogation systems. A compact neutron generator, currently being developed in Lawrence Berkeley National Laboratory, employs an array of 0.6-mm-dia apertures (instead of one 6-mm-dia aperture) such that gating the beamlets can be done with low voltage and a small gap to achieve sub-microsecond ion beam fall time and low background neutrons. Arrays of 16 apertures (4x4) and 100 apertures (10x10) have been designed and fabricated for a beam extraction experiment. The preliminary results showed that, using a gating voltage of 1200 V and a gap distance of 1 mm, the fall time of extracted ion beam pulses is approximately 0.15 mu s at beam energies of 1000 eV.

43 PARTICLE ACCELERATORS↗

The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Materials-based process tolerances for neutron generator encapsulation.

Variations in the neutron generator encapsulation process can affect functionality. However, instead of following the historical path in which the effects of process variations are assessed directly through functional tests, this study examines how material properties key to generator functionality correlate with process variations. The results of this type of investigation will be applicable to all generators and can provide insight on the most profitable paths to process and material improvements. Surprisingly, the results at this point imply that the process is quite robust, and many of the current process tolerances are perhaps overly restrictive. The good news lies in the fact that our current process ensures reproducible material properties. The bad new lies in the fact that it would be difficult to solve functional problems by changes in the process.

07 ISOTOPE AND RADIATION SOURCES↗

Beyond Californium—A Neutron Generator Alternative for Dosimetry and Instrument Calibration in the U.S.

Many evaluations of neutron survey instruments, area monitors and personal dosimeters rely on neutron reference radiations from 252Cf, a source of spontaneous fission neutrons that produces high dose rates from an almost point source geometry. Its characteristics are generally more favorable when compared to (a,n), photoneutron and reactor-based sources of neutrons. The source is typically used in two standardized configurations: unmoderated, to yield a fission energy spectrum, or placed within a heavy-water moderating sphere to produce a softened spectrum that is more appropriate for evaluating devices used in nuclear power plant work environments. The U.S. Department of Energy (DOE) 252Cf Loan/Lease Program was terminated in 2009, and the replacement of high-activity sources is increasingly cost prohibitive for laboratories that formerly benefited from that program, including the Pacific Northwest National Laboratory (PNNL) and National Institute of Standards and Technology (NIST). Neutron generators, based on the D-T and D-D fusion reactions, are becoming economically competitive with 252Cf and are recognized internationally as important calibration and test standards. Researchers from NIST and PNNLare jointly considering the practicality and technical challenges of implementing neutron generators as calibration standards in the U.S. This article reviews characteristics of isotope-based sources, leading to rationale behind increasing favor of electronically-generated neutron options. The evaluation of a D-T system at PNNL has revealed primary challenges in adapting generators to the task of calibration and testing in which neutron characteristics must be accurately determined. Concepts for modifying the generated neutron spectra to achieve particular targeted spectra, simulating 252Cf or workplace environments, are discussed.

Calibration, californium-252, Dosimeter Irradiatio↗