Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Completion of Irradiation of Sensors in ATRC Milestone

This set of PowerPoint slides demonstrates how milestone "M2CT-21IN0702023: Perform test of neutron flux sensors in the Advanced Test Reactor Critical Facility". It supports an entry in PICS claiming achievement of the milestone. These slides provide a good summary of the purpose and impact of the milestone for our DOE Headquarters colleagues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 $n_{eq}/cm^2$ fluence over the lifetime of the experiment.

AC-LGAD strips↗

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb -1 . In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project.

47 OTHER INSTRUMENTATION↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Analysis of WIRE-21 SPND and Optical Fiber Sensor Measurements

The Wireless Instrumented RB Experiment 2021 (WIRE-21) was a highly instrumented experiment designed to test prototype wireless temperature and pressure sensors developed by Westinghouse Electric Corporation (WEC) in the High Flux Isotope Reactor (HFIR). In addition to these sensors, a suite of other sensors was also integrated into the experiment capsule, including various types of distributed optical fiber sensors and self-powered neutron detectors (SPNDs). This report presents an analysis of the data generated by the SPNDs and optical fiber sensors that were tested under the highest reported neutron flux. The distributed optical fiber sensor results demonstrate that F-doped optical fibers, particularly those inscribed with fs fiber Bragg gratings (FBGs), are capable of surviving fast neutron fluences on the order of 1021 n fast /cm 2 at temperatures relevant to light-water reactors (between 200 and 400°C). However, a significant blue-shift in the optical spectra of these sensors was observed over the course of irradiation which cannot be explained based on the current understanding of radiation-induced compaction in fused silica glass. A mechanistic understanding of this drift has not yet been developed and is proposed as future scope under the Advanced Sensors and Instrumentation program. Of the four SPNDs, only one appeared to operate normally during three cycles of irradiation. A radiation transport model of the experiment in HFIR was used to determine time-dependent neutron flux in this SPND and to calculate the neutron sensitivity of the device. Results showed a cycle averaged sensitivity of 1.5 ×10 -22 and 1.4 ×10 -22 A/nν for the first and third cycles of irradiation, respectively. Additional details pertaining to the optical fibers and SPNDs are included herein.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Induced Noise Resilience of Neuromorphic Architectures

Neuromorphic event-based networks use asynchronous time-dependent information to extract features from input data that can allow for edge-based distributed applications such as object recognition. The noise resilience properties of such networks, especially in the context of space applications, are yet to be explored. In this paper, we use the hierarchy of time surfaces (HOTS) algorithm, which is one of the neuromorphic algorithms, to understand the least and most resilient modules in a neuromorphic network. The HOTS algorithm relies on the computing of time surfaces that maps the temporal delays between neighboring pixels into normalized features that involve many computations that are also found in other neuromorphic networks such as exponential decays, distance computations, etcetera. We implemented HOTS on a Digilent PYNQ board with a Xilinx Zynq 7020 system on a chip, and we subjected the boards running the HOTS network inference to neutron radiation at the Los Alamos Neutron Science Center. Furthermore, we used simulation models from our previous similar experiments on the event-based sensor to create a neutron induced noise model to quantify the effect of this noise on the overall performance of the network. This experiment provides the preliminary measurements of the reliability of the HOTS algorithm and proposes methods to create a more reliable HOTS architecture in future spacecraft missions.

Engineering↗