Neutron production and dosimetry with D(D,n) 3 He, 12 C(D,n) 13 N and 7 Li(p,n) 7 Be reactions at the Sandia Ion Beam Laboratory

Neutrons are produced at the Sandia Ion Beam Laboratory (IBL) using a beam of 280 keV D 2 + ions onto an erbium deuteride target. At test locations in the forward direction these neutrons have energies of about 2.9 MeV and a maximum flux on the flange of the test chamber of about 10 10 n/cm 2 /hour. Dosimetry is done by counting associated charged particles and by nickel foil activation dosimetry. Neutrons with higher energies, up to 6 MeV are produced using higher energy deuterium, up to 3 MeV, from the Pelletron ion accelerator at the IBL on a deuteride target. This report provides detailed information on the methods used for the production and dosimetry of neutrons by the D(D,n) 3 He nuclear reaction at the IBL. Neutron production by the 7 Li(p,n) 7 Be reaction with a proton beam from the Pelletron on a lithium target, such as LiF is also discussed. This produces neutrons with lower energy, in the range from about 0.1 to 1.3 MeV. Neutron production by the 12 C(D,n) 13 N reaction is also discussed. The purpose of this report is to provide information needed to test the effects of neutron irradiation on semiconductor materials and devices at the Sandia IBL.

36 MATERIALS SCIENCE↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Transport Modeling of High-Energy Neutrons Found in the Space Environment

The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.

Cox, Brad↗

ENDF/B-VIII.1: Updated Nuclear Reaction Data Library for Science and Applications

The ENDF/B-VIII.1 library is the newest recommended evaluated nuclear data file by the Cross Section Evaluation Working Group (CSEWG) for use in nuclear science and technology applications, and incorporates advances made in the six years since the release of ENDF/B-VIII.0. Among key advances made are that the 239 Pu file was reevaluated by a joint international effort and that updated 16,18 O, 19 F, 28–30 Si, 50–54 Cr, 55 Mn, 54,56,57 Fe, 63,65 Cu, 139 La, 233,235,238 U, and 240,241 Pu neutron nuclear data from the IAEA coordinated INDEN collaboration were adopted. Over 60 neutron dosimetry cross sections were adopted from the IAEA's IRDFF-II library. In addition, the new library includes significant changes for 3 He, 6 Li, 9 Be, 51 V, 88 Sr, 103 Rh, 140,142 Ce, Dy, 181 Ta, Pt, 206–208 Pb, and 234,236 U neutron data, and new nuclear data for the photonuclear, charged-particle and atomic sublibraries. Numerous thermal neutron scattering kernels were reevaluated or provided for the very first time. On the covariance side, work was undertaken to introduce better uncertainty quantification standards and testing for nuclear data covariances. The significant effort to reevaluate important nuclides has reduced bias in the simulations of many integral experiments with particular progress noted for fluorine, copper, and stainless steel containing benchmarks. Data issues hindered the successful deployment of the previous ENDF/B-VIII.0 for commercial nuclear power applications in high burnup situations. These issues were addressed by improving the 238 U and 239,240,241 Pu evaluated data in the resonance region. The new library performance as a function of burnup is similar to the reference ENDF/B-VII.1 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Universal Nuclear Accident Dosimeter

The Lawrence Livermore National Laboratory (LLNL) Universal Nuclear Accident Dosimetry (UNAD) project is a four-year initiative aimed at advancing nuclear accident dosimetry methods. This article presents an overview of the research, key findings, and the progress made throughout the project. The primary goals included a background into the history of nuclear accident dosimetry, consolidating current dosimetry techniques within the NNSA/DOE complex, fostering collaboration among subject matter experts, and exploring novel technologies for potential implementation. The technical focus centered on investigating new and novel technologies, instrumentation methods, and analysis methods to develop recommendations for a potential nuclear accident dosimeter (NAD) to be universally deployed through the DOE complex. A multilaboratory and multinational Usergroup was established, conducting periodic meetings to facilitate knowledge exchange. The UNAD team has participated in two international nuclear accident dosimetry intercomparison exercises and one characterization exercise, where the existing LLNL NAD and a prototype alanine electron paramagnetic dosimeter NAD were deployed. Ongoing improvements are being made to the prototype NAD based on results from the exercises, laboratory studies, and collaboration with other laboratories. A machine learning algorithm to optimize the geometry and conversion factors of the current LLNL NAD is being implemented, and the resulting design will be tested in the next exercise. In conclusion, key lessons learned and future directions for the project are discussed.

Electron paramagnetic resonance spectroscopy↗

Initial Findings in Qualifying the Instrument Thimble 11 Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Calculated covariance matrices for fission product yields using BeoH

Fission product yields (FPY) are important for a variety of applications (reactor neutronics, spent fuel, dosimetry, radiochemistry, etc.) and are currently included in many of the evaluated libraries around the world. The FPYs in the current US evaluation, ENDF/B-VIII.0, are mainly based on the 1994 evaluation of England and Rider and have only had slight updates—such as the inclusion of a 2 MeV point for 239 Pu—since their development. Additionally, only mean values and uncertainties are included in the evaluation, not full correlations. Los Alamos National Laboratory, in collaboration with several other institutes, has been working on an updated evaluation for the FPYs of 239 Pu(n,f), 235 U(n,f), 238 U(n,f), and 252 Cf(sf) using the deterministic, Hauser-Feshbach, fission fragment decay code, BeoH. BeoH calculates the FPYs consistently with many other prompt and delayed fission observables, explicitly taking into account multi-chance fission and ensuring consistency between observables. In addition to providing updated means and uncertainties for the FPYs on a pointwise energy grid from thermal to 20 MeV, we calculate correlations between all FPYs at each incident energy and across incident energies. Here, we discuss the development of these covariance matrices, differences in the correlations between FPYs based on the parameters that are included in the model optimization, and correlations across incident energies for neutron-induced fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion-kill dosimetry

Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

NASA Center JSC↗

ndi

The Nuclear Data Interface (NDI) is an application programming interface (API) that allows access to standard nuclear data parameters while hiding the underlying details of the data libraries and their storage. It allows access to multigroup transport data (neutron and gamma), thermonuclear burn data, dosimetry data, production/depletion chain data, radiochemistry data, and secondary neutron multiplicity data. The name NDI refers to both the code and data formats supported by the code.

Saller, Thomas↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Final Report DE-SC0020773

The DOE/NNSA sought development of innovative portable neutron/x-ray cameras for imaging and, when coupled with a portable source, also for radiography. This project focused on developing such a device that promises to have excellent resolution, while also providing neutron/gamma separation. We developed an Application Specific Integrated Circuit (ASIC) to be employed in conjunction with existing sensor technologies and modern assembly techniques. The concepts developed were a combination of new novel techniques and an innovative implementation of existing methods boosted by technological advances in ASIC performance.

61 RADIATION PROTECTION AND DOSIMETRY↗