Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the prompt fission neutron spectrum from 800 keV to 10 MeV for 240 Pu(sf) and for the 240 Pu($n,f$) reaction induced by neutrons of energy from 1–20 MeV

Here, the presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, (n,f), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, (sf), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu(sf) and the 240 Pu(n,f) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the (n,f) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing neutron-skin thickness with free spectator neutrons in ultracentral high-energy isobaric collisions

We show that the yield ratio of free spectator neutrons produced in high-energy 96 Zr+ 96 Zr to 96 Ru+ 96 Ru collisions is a clean probe of the neutron-skin thickness of colliding nuclei and the slope parameter L of the symmetry energy. The idea is demonstrated based on the proton and neutron density distributions via a state-of-the-art Skyrme-Hartree-Fock-Bogolyubov calculation. Among spectator nucleons given by the Glauber model, free spectator neutrons include those from direct production that survive from clusterization as well as those from deexcitation of heavy clusters described by the popular GEMINI model. More free neutrons are produced in collisions of 96 Zr nucleus due to its larger neutron skin, compared to those produced in collisions of 96 Ru nucleus with a smaller neutron skin. The difference of the free spectator neutron yield is further increased with the increasing difference of the neutron-skin thickness between 96 Zr and 96 Ru with a larger L value, and the increase in ultracentral collisions is particularly insensitive to model details and experimental uncertainties. Since the production of free spectator neutrons is not affected by the complicated dynamics in the mid-rapidity region, the ratio of their multiplicities in ultracentral isobaric collisions is a robust observable for constraining the neutron skin and L value.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiments with neutron induced neutron emission from U-235, Pu-239, and graphite

A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Star Radii, Deformabilities, and Moments of Inertia from Experimental and Ab Initio Theory Constraints of the 208Pb Neutron Skin Thickness

Recent experimental and ab initio theory investigations of the 208Pb neutron skin thickness have the potential to inform the neutron star equation of state. In particular, the strong correlation between the 208Pb neutron skin thickness and the pressure of neutron matter at normal nuclear densities leads to modified predictions for the radii, tidal deformabilities, and moments of inertia of typical 1.4M⊙ neutron stars. In the present work, we study the relative impact of these recent analyses of the 208Pb neutron skin thickness on bulk properties of neutron stars within a Bayesian statistical analysis. Two models for the equation of state prior are employed in order to highlight the role of the highly uncertain high-density equation of state. From our combined Bayesian analysis of nuclear theory, nuclear experiment, and observational constraints on the dense matter equation of state, we find at the 90% credibility level R1.4=12.36−0.73+0.38 km for the radius of a 1.4M⊙ neutron star, R2.0=11.96−0.71+0.94 km for the radius of a 2.0M⊙ neutron star, Λ1.4=440−144+103 for the tidal deformability of a 1.4M⊙ neutron star, and I1.338=1.425−0.146+0.074×1045gcm2 for the moment of inertia of PSR J0737-3039A whose mass is 1.338M⊙.

Lim, Yeunhwan↗

Neutrons in MINERvA and the Antineutrino Multi-Neutron Production Cross Section

Neutrinos are among a handful of particles in the Standard Model of particle physics whose properties have not yet been fully measured. Neutrino oscillations, discovered in the late 1990s, still have yet to be fully characterized. Early evidence suggests that neutrinos and antineutrinos may undergo neutrino oscillations differently. So, multiple collaborations are building and operating kTon-scale particle detectors to try to measure this CP violation in the neutrino sector of the Standard Model. Measuring neutrino and antineutrino energies is essential to characterizing oscillation phenomena. But neutrons interfere with (anti)neutrino energy measurements because they are hard to detect in (anti)neutrino detectors. Furthermore, there are very few measurements of neutrons produced by (anti)neutrinos in the energy range of interest to accelerator-based oscillation experiments. The MINERvA collaboration initially tried to fill this gap by measuring the rate of neutron-induced activity i n plastic. The data deviated significantly from leading model predictions, but it could not be determined which models needed to be tuned. MINERvA’s first neutron counting result also cannot be compared to future models because it was not suitable for unsmearing. This thesis first expands upon MINERvA’s first foray into neutron detection at higher antineutrino energy. Neutron detection efficiency is enhanced by advances in analysis algorithms. Then, an unsmeared cross section for producing two or more neutrons is measured. Existing antineutrino interaction models again over-predict the rate of neutron production by antineutrinos. Preliminary neutron production rate measurements in MINERvA’s iron and lead targets suggest that models are also over-predicting neutron production in heavier nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-neutron scattering length from the 6 He(p,pα)nn reaction

We propose a novel method to measure the neutron-neutron scattering length using the 6 He(p,pα)nn reaction in inverse kinematics at high energies. The method is based on the final-state interaction (FSI) between the neutrons after the sudden knockout of the α particle. We show that the details of the neutron-neutron relative-energy distribution allow for a precise extraction of the s-wave scattering length. Here, we present the state of the art in regard to the theory of this distribution. The distribution is calculated in two steps. First, we calculate the ground-state wave function of 6 He as a αnn three-body system. For this purpose we use Halo effective field theory, which also provides uncertainty estimates for the results. We compare our results at this stage to model calculations done with the computer code face. In a second step we determine the effects of the nn FSI using the nn t-matrix. We compare these FSI results to approximate FSI approaches based on standard FSI enhancement factors. While the final distribution is sensitive to the nn scattering length, it depends only weakly on the effective range. Throughout we emphasize the impact of theoretical uncertainties on the neutron-neutron relative-energy distribution, and discuss the extent to which those uncertainties limit the extraction of the neutron-neutron scattering length from the reaction 6 He(p,pα)nn.

6 ≤ A ≤ 19↗

Spin-polarized Neutron Matter, the Maximum Mass of Neutron Stars, and GW170817

In this work, we investigate how a phase transition from neutron-star matter to spin-polarized neutron matter affects the equation of state and mass–radius relation of neutron stars. While general extension schemes for the equation of state allow for high pressures inside neutron stars, we find that a phase transition to spin-polarized neutron matter excludes extreme regimes. Hence, such a transition limits the maximum mass of neutron stars that lie below 2.6–2.9 M ⊙ , depending on the microscopic nuclear forces used, while significantly larger masses could be reached without these constraints. Furthermore, these limits are in good agreement with recent constraints extracted from the neutron-star merger GW170817 and its electromagnetic counterpart. Assuming the description in terms of spin-polarized neutron matter to be valid in the center of neutron stars, we find that stars with a large spin-polarized domain in their core are ruled out by GW170817.

79 ASTRONOMY AND ASTROPHYSICS↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Updating the MCNP neutron guide extension for supermirror absorption, gamma production, and neutron polarization

As supermirror technology has developed, there is a trend towards higher m-values for supermirrors which propagate more neutrons with higher divergence to experimental areas. These supermirrors have thousands of alternating layers of typically nickel and titanium with varying thicknesses deposited on the surface. Neutrons of grazing incidence are reflected from these layers with a probability dependent on the angle of incidence and the wavelength of the neutron. Those neutrons that are not reflected may be captured in the supermirror layers and produce high energy gamma rays that require shielding. The supermirror extension for MCNP has been updated to estimate the capture of neutrons in the supermirror layers of a neutron guide through the banking of photons in a virtual supermirror layer and the reduction of the weight of the neutrons transmitted into the substrate. A new functionality has been added to simulate neutron polarization specifically in the context of a supermirror polarizer for neutron beamlines. In conclusion, the underlying theory, code implementation in MCNP, and examples of gamma production and a V-cavity polarizer will be discussed.

Gamma production↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗