Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON FLUX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of D-T Neutron Source Flux by SelfNeutron Activation Analysis with a LaBr3 Detector

Conclusions: • Decay of 78Br produced from the 79Br(n,2n) reaction in LaBr3 is present in the spectrum plotted in the time domain. • The neutron production rate reconstructed from preliminary LaBr3 estimate is smaller than the generator output. • Generator characterization may become more routine if a simple and robust method is made available for applications. Ongoing work: • Implementing bootstrapping to improve error estimates. • Examining threshold and edge effects of LaBr3

SMITH, MURRY↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Noble gas constraints on spent fuel irradiation histories

Fission gas isotopic compositions are sensitive to a variety of reactor operating parameters that include the neutron flux, neutron fluence at different neutron energies, and operating temperature. Measurements of fission gas isotopic compositions thus have potential to constrain reactor simulations for nuclear forensics and safeguards applications. In this paper, we present Kr and Xe isotope measurements from a suite of samples obtained from locations that span the axial length a fuel pin with a well-characterized irradiation history and compare these data to spatially resolved reactor simulations. Here, we observed positive correlations between fluence sensitive isotopic ratios and burnup and between a flux sensitive ratio and power, although some discrepancies are observed between the measured data and model predictions. These differences may be due to simplifications in the model and/or inaccuracies in the cross sections. A much broader measurement to model comparison is required to better understand the discrepancies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Flux Wire Selection on Neutron Spectrum Adjustment

In reactor dosimetry, spectrum unfolding methods are used to assess the energy-dependent neutron flux following the irradiation of flux wires or foils. For some spectrum unfolding methods, an a priori, or initial guess, spectrum is necessary. However, if the a priori spectrum is not representative of the irradiation spectrum experienced by the flux wires, the spectrum unfolding method may fail or create a nonphysical adjusted spectrum. The unfolded spectrum is dependent on flux wire reaction rates, and therefore cross section. As a result, each selection or combination of flux wires will have a different sensitivity to the group-wise fluence difference between the a priori spectrum and the irradiation spectrum. Therefore, a selection of flux wires that are insensitive to errors in the a priori spectrum would be considered robust choices for reactor dosimetry. In this work, flux wire reaction rates are calculated using a simulated neutron spectrum from the High Flux Isotope Reactor (HFIR) and spectrum unfolding methods are used in each flux wire combinations. The flux wire combinations are compared against a traditional flux wire set of Ti, Fe, and Co, with a summary table of the deemed “good” wire combinations that are insensitive to number of a priori neutron energy groups, group-wise difference between the a priori and irradiation, and magnitude of difference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large radiation back-flux from Monte Carlo simulations of fusion neutron–material interactions

Abstract Fusion power reactors will generate intense neutron fluxes into plasma-facing and structural materials (SMs). Radiation back-fluxes, generated from neutron–material interactions under these fluxes, can dramatically impact the plasma dynamics, e.g. by seeding runaway electrons during disruptions via Compton scattering of background electrons by wall-emitted gamma radiation. Here, we quantify these back-fluxes, including neutrons, gamma rays, and electrons, using Monte Carlo calculations for a range of SM candidates and first wall (FW) thicknesses. The radiation back-flux magnitudes are remarkably large, with neutron and gamma radiation back-fluxes on the same order of magnitude as the incident fusion neutron flux. Electron back-fluxes are two orders of magnitudes lower, but are emitted at sufficiently high energies to impact the sheath and boundary plasma dynamics. Material configuration plays a key role in determining back-flux magnitudes. The SM chiefly determines the neutron back-flux magnitude, while the FW thickness principally attenuates the gamma ray and electron back-fluxes. In addition to prompt back-fluxes, which are emitted immediately after fusion neutrons impact the surface, significant delayed gamma ray and electron back-fluxes arise from nuclear decay processes in the activated materials. These delayed back-flux magnitudes range from 2% to 7% of the prompt back-fluxes, and remain present during transients when fusion no longer occurs. During disruptions, build-up of delayed gamma radiation back-flux represents potential runaway electron seeding mechanisms, posing additional challenges for disruption mitigation in a power reactor compared with non-nuclear plasma operations. This work highlights the impact of these radiation back-fluxes plasma performance and demonstrates the importance of considering back-flux generation in materials selection for fusion power reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Experimental validation of a high fidelity Monte Carlo neutron transport model of the MIT graphite exponential pile

High-fidelity modeling and simulation were performed for the MIT graphite exponential pile (MGEP) using Monte Carlo neutron transport codes OpenMC and MCNP, and the results were validated by experimental data. The MGEP is being used as the test bed for the design of an autonomous control system for the pile's neutron flux distribution. The main contribution of this work is to generate the training data sets of neutron flux distributions with different locations of control rods that perturb the neutron flux profiles. First, code -to-code cross verification between OpenMC and MCNP was performed to ensure consistency of the numerical modeling within statistical uncertainties. To validate the accuracy of this high-fidelity model, a series of neutron flux measurements were conducted using a Helium-3 (He-3) neutron detector on a mobile platform that is placed inside the pile. Second, the neutron flux profiles were measured in four vertical layers of interest, and compared to the corresponding simulation results. The comparison results shows that the root mean square error is less than 2.5% in the two upper layers, and less than 4.5% in all four measured layers. Here the results validated the accuracy of the modeling and simulation. Finally, the relative change of the neutron flux profiles from moving control rods was analyzed, which identified the layer that has the best sensitivity regarding the control rods movements. Thus, this work identified and provided training data sets of both simulated and experimental neutron flux profiles in the most sensitive layer, paving the path forward to the real-time experimental demonstration of the autonomous control system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron diffusion calculation in heterogeneous geometry based on local/global iteration using proper orthogonal decomposition

This study newly proposes a heterogeneous core calculation method based on local/global iteration using proper orthogonal decomposition (POD). By using the singular value decomposition (SVD) and the low-rank approximation, appropriate POD bases for expanding the neutron flux can be obtained from snapshot data of the neutron flux obtained by fine mesh calculations. By projection using the POD bases, the dimension of the target equation (e.g., discretized neutron diffusion equation) can be dramatically reduced. In the proposed method, POD is effectively applied to each single assembly calculation (local calculation). Furthermore, using the local/global iteration, the effective neutron multiplication factor and the neutron flux distribution in the whole core geometry can be obtained by combining the numerical results of the local calculation for each fuel assembly and the global calculation for the whole core. As a feasibility study, the proposed method is applied to a one-dimensional heterogeneous core analysis, and the accuracy is investigated by changing the total number of POD bases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commissioning of the neutron irradiation station at the University of Notre Dame

Cross section data for neutron-induced reactions are needed for applications in nuclear astrophysics, stockpile stewardship, and nuclear reactor design but often contain discrepancies and gaps. A neutron source with a high neutron flux, a well-characterized neutron energy distribution, and a wide range of available neutron energies is ideal for studying such reactions in order to improve on existing data and provide new experimental results. For this purpose, the Neutron Irradiation Station (NIS) was developed using the 7 Li(p,n) 7 Be reaction. Neutron energy profiles were obtained using 3 He spectrometers and neutron standards were used to determine the neutron flux using the activation method. The neutron energy profile was found to be quasi-monoenergetic and neutrons were produced at energies from 1 keV to 1 MeV. Finally, the flux at the production target was found to be (1.42 ± 0.20) x 10 8 s −1 cm −2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasi-differential neutron induced neutron emissions from 235 U, and 239 Pu

Uncertainty in nuclear reaction cross sections, angular distributions, and other nuclear data directly impact how well simulations of nuclear systems represent physical observations. Here, to determine how well the nuclear data in ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0 evaluations describe the physical behaviour of 235 U, and 239 Pu when subjected to a neutron flux, the neutron emission spectrum was measured for carbon, 93.0% 235 U, and 93.9% 239 Pu samples, and compared against detailed MCNP6 simulations. The measurements were performed at the Los Alamos Neutron Science Center using a quasi-differential method previously developed at Rensselaer Polytechnic Institute. The measurement spanned 0.82–20 MeV and 30–150 degrees. The measurements show there are a significant number of discrepancies between library predictions of the neutron yield and physical observation. A few of the main discrepancies found are described in this paper. Based on these results a new evaluation utilizing these results for carbon, 235 U, and 239 Pu is recommended.

235U↗

Coupled neutronics and species transport simulation of the Molten Salt Reactor Experiment

This paper presents the development of coupling between the molten salt reactor species transport code Mole and the reactor physics code Griffin. Here, in this study, tracking of delayed neutron precursors was investigated in the Molten-Salt Reactor Experiment (MSRE), accounting for changes in fuel flow velocity as a function of position in the primary loop. The neutron transport calculations in Griffin were performed using 11 energy groups, and the species advection calculations in Mole used 6 delayed neutron precursor groups to predict spatial distribution of the neutron flux and neutron precursors in the MSRE. Mole–Griffin was used to calculate $k$ eff and $β$ eff in the reactor as a function of different volumetric flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of neutron noise in the research reactor AKR-2: comparison between a discrete ordinates and a diffusion-based method

A diffusion-based and a discrete ordinates method are used to simulate a neutron noise experiment in the research reactor AKR-2 at the Technical University in Dresden, Germany. The AKR-2 reactor provides an interesting case for the comparison between the two methods because it is characterized by large heterogeneities and regions with low macroscopic neutron cross-sections. For the calculations, the same spatial discretization and the same set of two-energy macroscopic neutron cross-sections with isotropic scattering are used. Significant discrepancies between the diffusion-based and discrete ordinates methods are found in regions of the systems where the diffusion approximation is expected to be inaccurate in reproducing characteristics of the static neutron flux and neutron noise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing the Impact of Large Removable Beryllium Reflector Experiments on HFIR Performance and Safety Metrics

This study investigated the effect of various removable beryllium (RB) experiment configurations on High Flux Isotope Reactor (HFIR) metrics to address increasing interest in these facilities for materials and fuels irradiation research. The RB reflector contains eight large and four small irradiation experiment facilities that offer excellent neutron flux conditions to perform fission and fusion reactor materials and fuels irradiation research. This work aims to outline acceptable RB configurations based on safety, performance, and programmatic metrics. This study assessed experiment effects on reactivity, cycle length, fission rate density distributions, and neutron flux distributions using the Shift, HFIRCON, and SCALE ORIGEN codes. Initial evaluations focused on generic experiment materials including aluminum plugs, stainless steel plugs, molybdenum plugs, and aluminum plugs with gadolinium shields. Subsequent analyses of MiniFuel experiments were performed to evaluate a heterogenous experiment, consisting of a more complex geometry and bearing several materials, and to test the correlations developed with the generic materials on a real experiment. Furthermore, the effects of neutron poison concentrations in the standard beryllium plugs were evaluated. When assuming a reference RB configuration with eight large fresh beryllium plugs, perturbed configurations with three aluminum plugs, one stainless steel plug, one molybdenum plug, one gadolinium-shielded aluminum plug, and one MiniFuel experiment resulted in a cycle length reduction of less than 1.3 days, the current threshold before requiring additional approvals. Configurations with five aluminum plugs, one stainless steel plug, one molybdenum plug, one gadolinium-shielded aluminum plug, and two MiniFuel experiments meet the 1.3 day limit if irradiated beryllium plugs are considered. Fuel element fission rate density distributions remained within safety limits, with maximum local increases under 9%. Neutron flux calculations revealed large thermal flux depressions inside and around the perturbed RB facilities, while epithermal and fast neutron fluxes increased because of reduced neutron moderation by the perturbed materials. These findings provide valuable guidance for optimizing RB configurations to balance safety and performance at HFIR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗