NIRCam: Development and Testing of the JWST Near-Infrared Camera

The Near Infrared Camera (NIRCam) is one of the four science instruments of the James Webb Space Telescope (JWST). Its high sensitivity, high spatial resolution images over the 0.6 - 5 microns wavelength region will be essential for making significant findings in many science areas as well as for aligning the JWST primary mirror segments and telescope. The NIRCam engineering test unit was recently assembled and has undergone successful cryogenic testing. The NIRCam collimator and camera optics and their mountings are also progressing, with a brass-board system demonstrating relatively low wavefront error across a wide field of view. The flight model?s long-wavelength Si grisms have been fabricated, and its coronagraph masks are now being made. Both the short (0.6 - 2.3 microns) and long (2.4 - 5.0 microns) wavelength flight detectors show good performance and are undergoing final assembly and testing. The flight model subsystems should all be completed later this year through early 2011, and NIRCam will be cryogenically tested in the first half of 2011 before delivery to the JWST integrated science instrument module (ISIM).

Greene, Thomas↗

Near infrared leaf reflectance modeling

Near infrared leaf reflectance modeling using Fresnel's equation (Kumar and Silva, 1973) and Snell's Law successfully approximated the spectral curve for a 0.25-mm turgid oak leaf lying on a Halon background. Calculations were made for ten interfaces, air-wax, wax-cellulose, cellulose-water, cellulose-air, air-water, and their inverses. A water path of 0.5 mm yielded acceptable results, and it was found that assignment of more weight to those interfaces involving air versus water or cellulose, and less to those involving wax, decreased the standard deviation of the error for all wavelengths. Data suggest that the air-cell interface is not the only important contributor to the overall reflectance of a leaf. Results also argue against the assertion that the near infrared plateau is a function of cell structure within the leaf.

Parrish, J. B.↗

Near-infrared observations of IRAS minisurvey galaxies

Near-infrared photometry was obtained for 82 galaxies from the Infrared Astronomy Satellite (IRAS) minisurvey, a sample of infrared selected galaxies. The near-infrared colors of these galaxies are similar to those of normal field spiral galaxies, but cover a larger range in J - H and H - K. There is evidence of a tighter correlation between the near and far infrared emission than exists between far-infrared and the visible emission. These results suggest that hot dust emission contributes to the 2.2 micron luminosity, and extinction by dust affects both the near-infrared colors and the visible luminosities. In addition, there is an indication that the far-infrared emission in many of the minisurvey galaxies is coming from a strong nuclear component.

Carico, D. P.↗

Near-infrared observations of IRAS minisurvey galaxies

Near-infrared photometry was obtained for 82 galaxies from the Infrared Astronomy Satellite (IRAS) minisurvey, a sample of infrared selected galaxies. The near-infrared colors of these galaxies are similar to those of normal field spiral galaxies, but cover a larger range in J - H and H - K. There is evidence of a tighter correlation between the near and far infrared emission than exists between far-infrared and the visible emission. These results suggest that hot dust emission contributes to the 2.2 micron luminosity, and extinction by dust affects both the near-infrared colors and the visible luminosities. In addition, there is an indication that the far-infrared emission in many of the minisurvey galaxies is coming from a strong nuclear component.

Carico, David P.↗

Near-infrared observations of IRAS minisurvey galaxies

Near infrared photometry at J, H, and K was obtained for 82 galaxies from the IRAS minisurvey. The near infrared colors of these galaxies cover a larger range in J-H and H-K than do normal field spiral galaxies, and evidence is presented of a tighter correlation between the near and far infrared emission in far infrared bright galaxies than exists between the far infrared and the visible emission. These results suggest the presence of dust in the far infrared bright galaxies, with hot dust emission contributing to the 2.2 micron emission, and extinction by dust affecting both the near infrared colors and the visible luminosities. In addition, there is some indication that the infrared emission in many of the minisurvey galaxies is coming from a strong nuclear component.

Carico, David P.↗

Heterovalent Substitution of K 2 SrP 2 O 7 :Cr 3+ to Achieve Anti-Thermal-Quenching Broadband Near-Infrared Luminescence

Broadband near-infrared (NIR) light sources based on phosphor-converted light-emitting diodes are highly desirable for biochemical analysis and medical diagnosis applications. However, thermal quenching remains a demanding challenge for developing efficient NIR phosphors. Herein, we report the enhancement of both quantum efficiency and thermal stability in Cr 3+ -activated K 2 SrP 2 O 7 phosphors through a heterovalent substitution strategy by replacing Sr 2+ with Al 3+ in K 2 Sr 1–x Al x P 2 O 7 (0.05 ≤ x ≤ 0.2) to obtain optimized broadband NIR emission. Structural modulation via Al 3+ substitution leads to the optimized composition, K 2 Sr 0.88 Al 0.1 P 2 O 7 :0.02Cr 3+ , which emits across a broad NIR range of 650–1100 nm peaking at 807 nm with a full width at half-maximum of ∼130 nm under 448 nm excitation. Remarkably, its emission intensity at 150 °C remains 120% of the initial value at room temperature, demonstrating a rare antithermal-quenching behavior. Temperature-dependent XRD studies further reveal that Al 3+ substitution effectively suppresses lattice expansion at elevated temperatures, indicating enhanced lattice stability under thermal excitation. Detailed structural and spectral analyses show that the substitution enhances local site symmetry, reduces electron–phonon coupling, increases thermally induced absorption probability, and fortifies energetic barriers against nonradiative transitions. These synergistic effects collectively endow this NIR phosphor with a superior thermal stability. Furthermore, NIR light-emitting diodes fabricated with this phosphor exhibit strong potential for applications in information identification, nondestructive detection, and night vision technologies. This study demonstrates a local structure engineering strategy for designing thermally robust Cr 3+ -activated NIR phosphors, offering valuable insights into material discovery and NIR spectroscopy device development.

Cr3+↗

Thermographic Imaging of the Space Shuttle During Re-Entry Using a Near Infrared Sensor

High resolution calibrated near infrared (NIR) imagery of the Space Shuttle Orbiter was obtained during hypervelocity atmospheric re-entry of the STS-119, STS-125, STS-128, STS-131, STS-132, STS-133, and STS-134 missions. This data has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. The thermal imagery complemented data collected with onboard surface thermocouple instrumentation. The spatially resolved global thermal measurements made during the Orbiter s hypersonic re-entry will provide critical flight data for reducing the uncertainty associated with present day ground-to-flight extrapolation techniques and current state-of-the-art empirical boundary-layer transition or turbulent heating prediction methods. Laminar and turbulent flight data is critical for the validation of physics-based, semi-empirical boundary-layer transition prediction methods as well as stimulating the validation of laminar numerical chemistry models and the development of turbulence models supporting NASA s next-generation spacecraft. In this paper we provide details of the NIR imaging system used on both air and land-based imaging assets. The paper will discuss calibrations performed on the NIR imaging systems that permitted conversion of captured radiant intensity (counts) to temperature values. Image processing techniques are presented to analyze the NIR data for vignetting distortion, best resolution, and image sharpness. Keywords: HYTHIRM, Space Shuttle thermography, hypersonic imaging, near infrared imaging, histogram analysis, singular value decomposition, eigenvalue image sharpness

Zalameda, Joseph N.↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Lunar Resources Using Moderate Spectral Resolution Visible and Near-infrared Spectroscopy: Al/si and Soil Maturity

Modern visible and near-infrared detectors are critically important for the accurate identification and relative abundance measurement of lunar minerals; however, even a very small number of well-placed visible and near-infrared bandpass channels provide a significant amount of general information about crucial lunar resources. The Galileo Solid State Imaging system (SSI) multispectral data are an important example of this. Al/Si and soil maturity will be discussed as examples of significant general lunar resource information that can be gleaned from moderate spectral resolution visible and near-infrared data with relative ease. Because quantitative-albedo data are necessary for these kinds of analyses, data such as those obtained by Galileo SSI are critical. SSI obtained synoptic digital multispectral image data for both the nearside and farside of the Moon during the first Galileo Earth-Moon encounter in December 1990. The data consist of images through seven filters with bandpasses ranging from 0.40 microns in the ultraviolet to 0.99 microns in the near-infrared. Although these data are of moderate spectral resolution, they still provide information for the following lunar resources: (1) titanium content of mature mare soils based upon the 0.40/0.56-micron (UV/VIS) ratio; (2) mafic mineral abundance based upon the 0.76/0.99-micron ratio; and (3) the maturity or exposure age of the soils based upon the 0.56-0.76-micron continuum and the 0.76/0.99-micron ratio. Within constraints, these moderate spectral resolution visible and near-infrared reflectance data can also provide elemental information such as Al/Si for mature highland soils.

Fischer, Erich M.↗

Empirical Constraints on the Cosmic Infrared Background Using Near-Infrared DIRBE Data

Empirical models for emission from stars and the ISM are subtracted from the zodiacal-light-subtracted DIRBE 3.5 pm emission. Because the models are contaminated by unknown levels of the CM at other near-IR wavelength, the residual is not simply the 3.5 Jim Cosmic IR Background, but a linear combination of the background levels at several wavelengths. In spite of this, the residual can be used to place limits on the near-IR CIB intensity if its spectral shape is assumed. Additionally, the residual level is shown to be more nearly isotropic than previous estimates over a much larger fraction of the sky. An excellent correlation of near-IR and far-IR ISM emission provides evidence of the high accuracy of the brighter stellar emission model. The possibility that any residual emission is zodiacal in nature is discussed.

Arendt, Richard G.↗

Near-infrared (J, H, K) imaging of Herbig Ae/Be stars

Near-infrared (J, H, K) images were obtained for 16 Herbig Ae/Be stars. The primary goal was to determine the contributions by circumstellar nebulae and nearby sources to near-infrared photometry carried out with large beams. Quasi-simultaneous photometric results were obtained with small apertures. The emission toward five Herbig Ae/Be stars is extended, including all four Group II sources in our sample (Hillebrand et al. 1992); 13 objects have nearby sources (within 10 sec separation). However, the extended emission and nearby sources are too faint to affect previous photometry significantly. The surface brightness profiles of most of the nebulae can be explained by reflection nebulae which scatter the light from the central star/disk systems with single, isotropic scattering processes. The exception is Par 21, which may require emission from very small grains. The color-color diagram, making use of our new photometry, essentially agrees with the results of Lada & Adams (1992). The Group II objects in our sample tend to have extended emission more frequently than do Group I objects, supporting the suggestion of Hillebrand et al. that Group II sources are more affected by circumstellar envelopes. However, most of the near-infrared emission comes from the central (less than or = 6 sec) regions. This upper limit is still much larger than the expected size of accretion disks. Possible envelope effects could not be ruled out for most Herbig Ae/Be stars with unresolved emission. The images do not clearly favor very small, thermally emitting grains as the origin of the near-infrared emission. The problem still exists of how to explain the observed peaks near 3 sec in the spectral energy distributions of Herbig Ae/Be stars. The possible effects of envelopes and companions are addressed.

Li, Wenbin↗

Investigating the Curing Process of Epoxy Thermosets by Near-Infrared (nIR) Spectroscopy

Near-Infrared (nIR) Spectroscopy is a type of absorption spectroscopy that may be used to study the curing process of thermosetting epoxy-based resins like Eccostock FFP. This is accomplished by monitoring the absorption bands of the epoxy oxirane ring, which decrease in intensity with increasing degree of cure. Relative to epoxy absorption bands in the mid-IR region, those in the nIR range exhibit less overlap, allowing for a more accurate analysis of cure kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detectors for the JWST Near-Infrared Spectrometer

The Near-Infrared Spectrometer (NIRSpec) places the most stringent demands upon its detectors of all James Webb Space Telescope (JWST) instruments. We present the scientific rationale for challenging requirements including noise <or=6 e- rms per exposure. In concert, we discuss laboratory test results that are informing the design of NIRSpec's detector system and operational concept.

Rauscher, B. J.↗

Improved Reference Sampling and Subtraction: A Technique for Reducing the Read Noise of Near-Infrared Detector Systems

Near-infrared array detectors, like the James Webb Space Telescope (JWST) NIRSpec's Teledyne's H2RGs, often provide reference pixels and a reference output. These are used to remove correlated noise. Improved reference sampling and subtraction (IRS(exp 2)) is a statistical technique for using this reference information optimally in a leastsquares sense. Compared with the traditional H2RG readout, IRS(exp 2) uses a different clocking pattern to interleave many more reference pixels into the data than is otherwise possible. Compared with standard reference correction techniques, IRS(exp 2) subtracts the reference pixels and reference output using a statistically optimized set of frequency dependent weights. The benefits include somewhat lower noise variance and much less obvious correlated noise. NIRSpec's IRS(exp 2) images are cosmetically clean, with less 1/f banding than in traditional data from the same system. This article describes the IRS(exp 2) clocking pattern and presents the equations needed to use IRS(exp 2) in systems other than NIRSpec. For NIRSpec, applying these equations is already an option in the calibration pipeline. As an aid to instrument builders, we provide our prototype IRS(exp 2) calibration software and sample JWST NIRSpec data. The same techniques are applicable to other detector systems, including those based on Teledyne's H4RG arrays. The H4RG's interleaved reference pixel readout mode is effectively one IRS(exp 2) pattern.

Methods-statistical↗

The near-infrared polarization and color of Comet Halley: What can we learn about the grains

The near infrared polarization and JHK colors of light scattered by dust grains in comet Halley were measured over a wide range in phase angle and heliocentric distance. Colors were redder than solar with no statistically significant variation with phase angle, heliocentric distance, or pre- and post-perihelion. This suggests that the grain population did not change drastically over time and that the data may be combined and modeled. However, short term variations in visible polarization and dust albedo were seen in Halley. Also, near infrared colors became systematically bluer after the observations were completed. The near infrared colors of Halley fall in the range of those of other comets. The near infrared polarization is similar to the visible polarization of Halley and other comets in showing a negative branch at small phase angles and an approximately linear rise toward positive values at larger phase angles. Mie theory calculations and a size distribution based on spacecraft data were used to model the near infrared polarization and color of comet Halley. Numerous lines of evidence point to the presence of dark, absorbing, probably carbonaceous materials in comets.

Brooke, Timothy Y.↗

Near-Infrared Optical Gain of Colloidal Quantum Wells via Intraband Transitions

Tunable, unipolar, near-infrared intraband optical gain is demonstrated in semiconductor colloidal quantum wells, expanding the form and optical range for potential infrared applications. Atomically flat colloidal quantum wells of cadmium selenide display photoinduced absorption features in the near-infrared assigned to intraband (alternatively intersubband) transitions from the first to second electron subbands of the quantum wells. Under ultraviolet optical excitation, these same transitions from the first to second electron subbands are shown to exhibit stimulated emission, resulting in optical gain covering the near-infrared spectral region. The modal gain, bandwidth, and lifetime of this intraband gain are manipulated by using excitation energy, fluence, temperature, and surface chemistry. Unlike previous demonstrations of intraband optical gain in epitaxial quantum wells (e.g., quantum cascade lasers), the colloidal quantum wells are undoped. As a result, nearly thresholdless gain is in principle possible and limited in practice by the measurement of small optical losses of the samples in the near-infrared. Furthermore, the observations may be understood as a modified "quantum fountain" employing the valence band, a strategy that may be applied to many other materials.

Optical gain↗