Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NASA SPACE RADIATION LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Commissioning of the EBIS-based heavy ion preinjector at Brookhaven

The status is presented of the commissioning of a new heavy ion preinjector at Brookhaven National Laboratory. This preinjector uses an Electron Beam Ion Source (EBIS), and an RFQ and IH Linac, both operating at 100.625 MHz, to produce 2 MeV/u ions of any species for use, after further acceleration, at the Relativistic Heavy Ion Collider (RHIC) and the NASA Space Radiation Laboratory (NSRL). Among the increased capabilities provided by this preinjector are the ability to produce ions of any species, and the ability to switch between multiple species in 1 second, to simultaneously meet the needs of both science programs. For initial setup, helium beam from EBIS was injected and circulated in the Booster synchrotron. Following this, accelerated Au{sup 32+} and Fe{sup 20+} beams were transported to the Booster injection point, fulfilling DOE requirements for project completion.

43 PARTICLE ACCELERATORS↗

The Electron Beam Ion Source (EBIS)

Brookhaven National Lab has successfully developed a new pre-injector system, called the Electron Beam Ion Source, for the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. The first of several planned improvemen

43 PARTICLE ACCELERATORS↗

Progress of the laser ion source upgrade (LION2) for RHIC and NSRL program at Brookhaven National Laboratory

At Brookhaven National Laboratory (BNL), the LION2 ion source is being constructed to replace an existing laser ion ablation ion source (LIS) at the EBIS facility, which provides heavy ion beams of multiple ion species for the operation of NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). The LION1 ion source currently provides singly charged ions of Li, B, C, O, Al, Si, Ca, Ti, Fe, Cu, Zr, Nb, Ag, Tb, Ta, W, Au, Bi, and Th with a rapid-species-change capability. An electron beam ion source, Extended-EBIS captures, confines, and ionizes the ions to high charge state, suitable for injection and acceleration by an RFQ accelerator. Typically, single pulses of the LIS ion species for NSRL are changed sequentially during Galactic Cosmic Ray experiments, while multiple pulses of a given ion beam are provided quasi-simultaneously for RHIC. LION2 will have the same capability of the rapid-species-change with improved beam performance and reliability. LION2 is being constructed in a remote assembly location and is expected to finish in December 2023. The removal of LION1 and installation of LION2 is planned during the December 2023 or summer 2024 shutdown.

43 PARTICLE ACCELERATORS↗

Performance on the low charge state laser ion source in BNL

On March 2014, a Laser Ion Source (LIS) was commissioned which delivers high-brightness, low-charge-state heavy ions for the hadron accelerator complex in Brookhaven National Laboratory (BNL). Since then, the LIS has provided many heavy ion species successfully. The low-charge-state (mostly singly charged) beams are injected to the Electron Beam Ion Source (EBIS), where ions are then highly ionized to fit to the following accelerator’s Q/M acceptance, like Au 32+ . Recently we upgraded the LIS to be able to provide two different beams into EBIS on a pulse-to-pulse basis. Now the LIS is simultaneously providing beams for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL).

43 PARTICLE ACCELERATORS↗

Performance of the new EBIS preinjector

The construction and initial commissioning phase of a new heavy ion preinjector was completed at Brookhaven in September, 2010, and the preinjector is now operational. This preinjector, using an EBIS source to produce high charge state heavy ions, provided helium and neon ion beams for use at the NASA Space Radiation Laboratory in the Fall of 2010, and gold and uranium beams are being commissioned during the 2011 run cycle for use in RHIC. The EBIS operates with an electron beam current of up to 10 A, to produce mA level currents in 10-40 {micro}s beam pulses. The source is followed by an RFQ and IH linac to accelerate ions with q/m > 0.16 to an energy of 2 MeV/amu, for injection into the Booster synchrotron. The performance of the preinjector is presented, including initial operational experience for the NASA and RHIC programs.

43 PARTICLE ACCELERATORS↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Reliable operation of the Brookhaven EBIS for highly charged ion production for RHIC and NSRL

An Electron Beam Ion Source for the Relativistic Heavy Ion Collider (RHIC EBIS) was commissioned at Brookhaven in September 2010 and since then it routinely supplies ions for RHIC and NASA Space Radiation Laboratory (NSRL) as the main source of highly charged ions from Helium to Uranium. Using three external primary ion sources for 1+ injection into the EBIS and an electrostatic injection beam line, ion species at the EBIS exit can be switched in 0.2 s. A total of 16 different ion species have been produced to date. The length and the capacity of the ion trap have been increased by 20% by extending the trap by two more drift tubes, compared with the original design. The fraction of Au{sup 32+} in the EBIS Au spectrum is approximately 12% for 70-80% electron beam neutralization and 8 pulses operation in a 5 Hertz train and 4-5 s super cycle. For single pulse per super cycle operation and 25% electron beam neutralization, the EBIS achieves the theoretical Au{sup 32+} fractional output of 18%. Long term stability has been very good with availability of the beam from RHIC EBIS during 2012 and 2014 RHIC runs approximately 99.8%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First test of BNL electron beam ion source with high current density electron beam

A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.

43 PARTICLE ACCELERATORS↗

Light charged ion measurements and Monte Carlo calculations from thick targets bombarded by protons and heavy ions - 25435

The data presented in this work are from experiments performed in November 2016 and November 2017 at the National Aeronautics and Space Administration (NASA) Space Radiation Laboratory at Brookhaven National Laboratory (BNL). The secondary light charged ions (Z=1 and 2 ions) and neutrons produced by 400-, 800-, and 2500-AMeV protons and 400-, 800-, and 1500-AMeV He, C, Si, Fe ions bombarding thick targets (20, 40, and 60 g/cm{sup 2} aluminum and high-density polyethylene (HDPE), and 20 and 60 g/cm{sup 2} combination of aluminum and HDPE) were measured with organic liquid scintillators and sodium iodide (NaI) detectors. The organic liquid scintillators were positioned at 10 deg., 30 deg., 45 deg., 60 deg., 80 deg., and 135 deg. with respect to the beam direction, while NaI detectors were placed at 10 deg. and 30 deg. off the beam axis. The double-differential thick-target secondary light charged ion yields measured by organic liquid scintillators are of main interest here. In the analysis, after applying pulse shape discrimination to separate protons, deuterons, tritons, helium-3, and helium-4 particles, the time of flight technique was used to produce the secondary charged particle angular-energy spectra. Additionally, the spectra were compared with simulation results using the Monte Carlo simulation code, PHITS version 2.88. To obtain favorable statistics in PHITS calculations, ring-type detectors were modeled, which have the same distances and equivalent angles with the experimental setup. These experimental data will be integrated into the uncertainty analysis for NASA to optimize future GCR shielding design. (authors)

43 PARTICLE ACCELERATORS↗

Beam commissioning results for the RFQ and MEBT of the EBIS based preinjector for RHIC

The EBIS based preinjector for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL) is now being commissioned at Brookhaven National Laboratory (BNL). In 2008, the RFQ for the project was delivered and commissioned using Test EBIS, which was built to demonstrate the high current EBIS's performance. A dedicated beamline after the RFQ was assembled to confirm the RFQ's performance, and the beam energy was measured by a bending dipole magnet. In November 2009, the RFQ was moved to the final location and the vanes were realigned. The beam commissioning with the RHIC-EBIS was started again during March 2010. The RFQ accelerates ions from 17 keV/u to 300 keV/u and operates at 100.625 MHz. It is followed by a short Medium Energy Beam Transport (MEBT), which consists of four quadrupoles and one buncher cavity. Some temporary diagnostics for this commissioning include an emittance probe, TOF system, fast Faraday cup, and beam current measurement units. As of September 2010, the RFQ and the MEBT show expected performance with He{sup +}, Au{sup 32+} and Fe{sup 20+} beams. Further commissioning for higher intensity beams is in progress.

43 PARTICLE ACCELERATORS↗

Impact of galactic cosmic ray simulation on nutritional content of foods

Foods packaged for future deep-space exploration missions may be prepositioned ahead of astronaut arrival, and will be exposed to galactic cosmic rays (GCRs) and solar radiation in deep space at higher levels and different spectrums than those found in low-Earth orbit (LEO). In this study, we have evaluated the impact of a GCR simulation (approximately 0.5 and 5 Gy doses) at the NASA Space Radiation Laboratory (NSRL) on two retort thermostabilized food products that are good sources of radiation labile nutrients (thiamin, vitamin E, or unsaturated fats). No trends or nutritional differences were found between the radiation-treated samples and the control immediately after treatment or one-year after treatment. Small changes in a few nutrients were measured following one-year of storage. Further studies are needed to confirm these results, as the foods in this study were heterogeneous, and this may have masked meaningful changes due to pouch-to-pouch variations.

59 BASIC BIOLOGICAL SCIENCES↗

BNL test electron beam ion source operation on a 100 kV platform (abstract)

At BNL, we are preparing to build an electron beam ion source (EBIS) that will satisfy the requirements of the relativistic heavy ion collider (RHIC), e.g., Au{sup 32+} ions of about 3x10{sup 9} particles/pulse in 10-40 {mu}s pulses at 5 Hz. In addition, the EBIS is required to deliver beams such as He{sup 2+}, C{sup 6+}, O{sup 8+}, Si{sup 14+}, Ti{sup 18+}, Fe{sup 21+}, and Cu{sup 22+} in {approx}2-3 mA, 10 {mu}s pulses at 5 Hz to meet the demands of the NASA Space Radiation Laboratory (NSRL) experimental program. Development studies continue to be carried out on the BNL test EBIS, a half-length full electron beam power prototype of the RHIC EBIS which is in the construction phase. In preparation for acceleration of EBIS ions by a radio frequency quadrupole, we have upgraded the test EBIS for operation on a nominal 100 kV pulsed platform to allow seed ion injection at 10-20 kV and ion extraction up to 100 q kV. The installation includes a pulsed high voltage power supply, a 200 kV A 100 kV isolation transformer, and a capacitive electron collector supply and electron gun bias supply which allows operation in a similar mode to the RHIC EBIS design. Initial testing has been made using ion beams of He{sup 2+} and Ar{sup 10+} formed from gas injection and ions have been extracted with energies up to 88 q keV. Total ion current measurement has been made and charge state distributions have been obtained using a Mamyrin time of flight. Results of emittance measurements and profile distributions, obtained at various energies using both pepperpot and slit-foil emittance meters, will be presented.

43 PARTICLE ACCELERATORS↗

Development of ion injection into the BNL test electron beam ion source using a prototype low energy beam transfer switchyard and a hollow cathode ion source (abstract)

In order to provide a variety of ion species to the BNL relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory facilities on a pulse-to-pulse basis, the BNL RHIC electron beam ion source (EBIS) will use injection of primary ''seed'' ions from external low charged ion sources. As part of the prototype for the RHIC EBIS low energy beam transport line, a switchyard for seed ion injection and extracted EBIS ion beams has been constructed. The ion injection line includes a hollow cathode ion source (HCIS), four quadrupole lenses, a switchyard, gridded lenses, and other deflection optics. The HCIS is based on one obtained from CEA Saclay [B. Visentin et al., Phys. Scr., T 71, 204 (1997).] and has been used in bench studies in the production of low charged metal and gas ions, as well as in BNL test EBIS injection studies for the production of highly charged ions. The HCIS geometry and extraction optics have been modified to be able to reach the output currents necessary to seed the test EBIS. Ion currents greater than 60 {mu}A Cu{sup +} and 130 {mu}A Ne{sup +} have been extracted from the modified HCIS at 12-15 kV and plasma aperture of 1-1.5 mm. The HCIS discharge is initiated by a rf coil and can be operated stably at pulse rates from 1 to 100 Hz. Measurement of the emittance of injector beam before and after the injection switchyard will be provided, as well as results from ion injection into the test EBIS using the new injector configuration.

43 PARTICLE ACCELERATORS↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source

An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.

43 PARTICLE ACCELERATORS↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Genotoxicity of charged particles of importance in space flight using murine kidney epithelial cells

Ionizing radiation presents significant challenges for human space flight including an increased cancer risk. High-energy heavy ions in the galactic cosmic radiation can produce qualitative and quantitative differences in biological effects when compared with sparsely ionizing radiations. Mutations are induced by charged particle exposure and are integral to the formation and/or progression of human cancers. Most cancer-associated mutations occur on autosomal chromosomes, and most solid cancers occur in epithelial tissues. Here, a combined in vitro/in vivo approach was used to evaluate cell killing and the induction of mutations at a model autosomal locus, Aprt, in mouse kidney epithelium. For in vitro exposures, Aprt heterozygous kidney cells (clones 1a, 4a or 6a) were used from C57BL/6×DBA/2 mice. Additional experiments were performed using whole body irradiation of mice with the same genotype. Both males and females were irradiated in approximately equal numbers. Irradiations were performed at the NASA Space Radiation Laboratories at Brookhaven National Laboratory. For in vitro studies, cells from primary kidney clones were irradiated and seeded at limiting dilution immediately post-irradiation to determine the toxicity of the treatment. The irradiated kidney cells were also seeded in mutation assays within 1 week post-irradiation to determine the Aprt mutant fraction at the earliest time post-exposure. This work was complemented by studies wherein mice were exposed to the same ions with kidneys harvested several months post-irradiation to determine the residual toxicity and the Aprt mutant fraction. Our previous studies focused on sparsely ionizing 1 GeV protons (LET = 0.24 keV/µm) and densely ionizing 1 GeV/amu Fe ions (LET = 151 keV/µm). Our most recent studies have included work with Si ions (240 MeV/amu for in vitro studies, LET = 78 keV/µm; 263 MeV/amu initial energy for in vivo studies to achieve 78 keV/µm near the midline of the animal) and O ions (250 MeV/amu in vitro studies only, LET = 25 keV/µm). Toxicity for the cultured kidney cells in vitro follows this pattern: Fe > Si > O > protons when the results are expressed per unit dose. D0 values were 92 cGy for Fe ions, 103 cGy for Si ions, 192 cGy for O ions and 340 cGy for protons. With regard to the induction of Aprt mutations, Fe ions were more mutagenic than protons. Si ions were also quite mutagenic with evidence for a linear dose–response for Aprt mutations in kidney cells exposed in vitro or in kidneys harvested from mice irradiated several months earlier. These results are consistent with the linear dose–response data obtained previously for Aprt mutation induction following Fe ion exposure in vitro or in vivo, but the results for Si ions differ from the curvilinear dose–response data we recently published following similar exposures to energetic protons [ 1, 2]. Our most recent studies examined the molecular characteristics of Si ion-induced Aprt mutants following in vitro exposure. A dose of 160 cGy was used to collect 58 Aprt kidney cell mutants. Mutational events were classified as follows based on PCR-based analyses of polymorphic markers along mouse chromosome 8: intragenic events, apparent mitotic recombination, interstitial deletions of Aprt only, multilocus deletions, discontinuous loss of heterozygosity or whole chromosome loss. The results for this group of mutants will be compared against our previous studies on Aprt mutants arising after exposure to sparsely ionizing 1 GeV protons or densely ionizing 1 GeV/amu Fe ions. Additional studies are ongoing to define mutational spectra following Si ion exposure to kidney epithelium in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-526: Irradiation of Human Cell Lines Using Carbon Ions: Real Time Dosimetry Using Gaf-Chromic Film

Purpose: The purpose of this study is to investigate and quantify several factors affecting biological effects of carbon ions such as cell type, dose, energy and position where the cells are irradiated along the pristine Bragg curve. Methods: Experiments to quantify clonogenic cell survival in three human lung cancer cell lines and a fibroblast cell line were performed at the NASA Space Radiation Laboratory, BNL, Upton, USA. A system of water or media-filled T25 flasks lined up along the beam axis was designed so that the cell-containing surfaces of the flasks were placed at specific depths along the Bragg curve. Gaf-chromic films were placed between the flasks to monitor the dose distribution in the sample as soon as the irradiation was finished. Additional studies were conducted at four selected depths along the Bragg curve to obtain full cell survival dose response curves for the four cell lines. Results: The percent depth dose of the beams was determined using an ionization chamber and showed that the physical Bragg peak is at 22.5 cm water depth. However, the clonogenic cell survival data indicated that the maximum cell killing occurred at 21.5 cm. Gaf-chromic films revealed some inhomogeneity in the dose distribution on the flasks near the peak, presumably due to lack of scattering from the sides of the flasks, which might account for the differences. Depending on the cell line and radiation dose, the maximum cell killing (i.e., the greatest RBE) is at the 21.5 (the peak) or 24 cm (distal fall off) depth. Conclusion: There is a difference in biological effect along the Bragg curve of a carbon ion beam, indicating an elevated RBE at or beyond the end of the range. Gaf-chromic films are proven to be effective in monitoring the 2D irradiation pattern to the flasks. Research supported by NIH/NCI through grant no. R21 CA182259.

60 APPLIED LIFE SCIENCES↗