Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Muon System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at $\sqrt{s}=$ 13 TeV

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013–2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy √s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

Performance of the CMS muon trigger system in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 $\times$ 10$^{34}$cm$^{-2}$s$^{-1}$ while delivering proton-proton collisions at $\sqrt{s} =$ 13 TeV. The challenge for the trigger system of the CMS experiment is to reduce the registered event rate from about 40 MHz to about 1 kHz. Significant improvements important for the success of the CMS physics program have been made to the muon trigger system via improved muon reconstruction and identification algorithms since the end of Run 1 and throughout the Run 2 data-taking period. The new algorithms maintain the acceptance of the muon triggers at the same or even lower rate throughout the data-taking period despite the increasing number of additional proton-proton interactions in each LHC bunch crossing. In this paper, the algorithms used in 2015 and 2016 and their improvements throughout 2017 and 2018 are described. Measurements of the CMS muon trigger performance for this data-taking period are presented, including efficiencies, transverse momentum resolution, trigger rates, and the purity of the selected muon sample. This paper focuses on the single- and double-muon triggers with the lowest sustainable transverse momentum thresholds used by CMS. The efficiency is measured in a transverse momentum range from 8 to several hundred GeV.

Trigger detectors↗

Development of high-resolution muon tracking systems based on micro-pattern detectors

A muon tracking system consisting of four 9 cm x 10 cm sized bulk Micromegas detectors with 128 {mu}m amplification-gap and two 10 cm x 10 cm triple GEM detectors is foreseen for high-precision tracking of 140 GeV muons at the H8 beamline at CERN with a rate of up to 10 kHz and an overall resolution below 40 {mu}m. Larger detectors with an active area of 0.5 m{sup 2} and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9 keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO{sub 2}. The signals were digitized using 1 GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80 {mu}m was measured using a fast Gassiplex based strip readout with readout strips of 150 {mu}m width and a pitch of 250 {mu}m. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the front-end boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cryogenic Muon Tagging System Integrated with a Superconducting Qubit Device for Radiation-Induced Error Mitigation

Superconducting qubits are highly sensitive to ionizing radiation, which can induce correlated errors and limit scalable fault-tolerant quantum computing. In particular, cosmic-ray muons can deposit energy in the substrate, generating phonon bursts that break Cooper pairs and produce quasiparticles, leading to correlated decoherence events across multiple qubits. We present the development of a cryogenic muon tagging system based on Kinetic Inductance Detectors (KIDs) and its integration with superconducting quantum hardware. Originally developed within the ACE-SuperQ project and validated as a standalone detector, the system demonstrated a muon tagging efficiency of approximately 90% and excellent agreement with Monte Carlo simulations. Building on this validation, the tagging system has been integrated with a multi-qubit superconducting chip operated in a dilution refrigerator. The detector configuration consists of a multi-layer KID stack arranged above and below the quantum device, enabling time-coincident identification of muon-induced events within the same cryogenic environment. The integrated setup has been successfully commissioned, enabling simultaneous operation of the qubit chip and the muon tagging system. A first measurement campaign has been carried out, and preliminary data show time-correlated events between the muon tagging detectors and the qubit readout. A quantitative analysis of radiation-induced effects on qubit performance is currently ongoing. This work represents a step toward the implementation of event-level radiation tagging as a tool for characterizing and potentially mitigating correlated errors in superconducting quantum processors, while establishing a modular platform for future studies at the interface between particle physics and quantum information science.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

Design Concepts for Muon-Based Accelerators

Muon-based accelerators have the potential to enable facilities at both the Intensity and the Energy Frontiers. Muon storage rings can serve as high precision neutrino sources, and a muon collider is an ideal technology for a TeV or multi-TeV collider. Progress in muon accelerator designs has advanced steadily in recent years. In regard to 6D muon cooling, detailed and realistic designs now exist that provide more than 5 order-of-magnitude emittance reduction. Furthermore, detector performance studies indicate that with suitable pixelation and timing resolution, backgrounds in the collider detectors can be significantly reduced thus enabling high quality physics results. Thanks to these and other advances in design & simulation of muon systems, technology development, and systems demonstrations, muon storage-ring-based neutrino sources and a muon collider appear more feasible than ever before. A muon collider is now arguably among the most compelling approaches to a multi-TeV lepton collider. This paper summarizes the current status of design concepts for muon-based accelerators for neutrino factories and a muon collider.

Bogacz, Slawomir↗

Design Concepts for Muon-Based Accelerators

Muon-based accelerators have the potential to enable facilities at both the Intensity and the Energy Frontiers. Muon storage rings can serve as high precision neutrino sources, and a muon collider is an ideal technology for a TeV or multi-TeV collider. Progress in muon accelerator designs has advanced steadily in recent years. In regard to 6D muon cooling, detailed and realistic designs now exist that provide more than 5 order-of-magnitude emittance reduction. Furthermore, detector performance studies indicate that with suitable pixelation and timing resolution, backgrounds in the collider detectors can be significantly reduced, thus enabling high-quality physics results. Thanks to these and other advances in design & simulation of muon systems, technology development, and systems demonstrations, muon storage-ring-based neutrino sources and a muon collider appear more feasible than ever before. A muon collider is now arguably among the most compelling approaches to a multi-TeV lepton collider. This paper summarizes the current status of design concepts for muon-based accelerators for neutrino factories and a muon collider.

43 PARTICLE ACCELERATORS↗

A cryogenic muon tagging system based on kinetic inductance detectors for superconducting quantum processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on kinetic inductance detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at ∼20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient γ-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 ± 9) $\times\,10^{-3}$ events s$^{−1}$, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

Mariani, Ambra [INFN, Rome] (ORCID:000000028184857↗

THE CMS RPC SYSTEM OVERVIEW

The Muon System of the CMS experiment at CERN employees three different detector technologies--Drift Tube Chambers (DT) in the barrel part, Cathode Strip Chambers (CSC) in the endcaps and Resistive Plate Chambers (RPC) both in the barrel and the endcaps. TDs and CSCs serve as precise muon trajectory measurement devices. The RPCs are responsible for the bunch crossing identification and for a fast muon transverse momentum measurement. The total number of RPCs is 480 in the barrel and 756 in the endcaps, covering an area of about 3500 square meters. A brief overview of the system will be presented as well as some recent results about the system stability and performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting Aberrations in Complex Magnet Systems for Muon Cooling Channels

Designing and simulating complex magnet systems needed for cooling channels in both neutrino factories and muon colliders requires innovative techniques to correct for both chromatic and spherical aberrations. Optimizing complex systems, such as helical magnets for example, is also difficult but essential. By using COSY INFINITY, a differential algebra based code, the transfer and aberration maps can be examined to discover what critical terms have the greatest influence on these aberrations.

43 PARTICLE ACCELERATORS↗

Performance of the MICE diagnostic system

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

43 PARTICLE ACCELERATORS↗

Development of a Portable Muon Witness System

Since understanding and quantifying cosmic ray induced radioactive backgrounds in copper and germanium are important to the MAJORANA DEMONSTRATOR, methods are needed for monitoring the levels of such backgrounds produced in materials being transported and processed for the experiment. This report focuses on work conducted at Pacific Northwest National Laboratory to develop a muon witness system as a one way of monitoring induced activities. The operational goal of this apparatus is to characterize cosmic ray exposure of materials. The cosmic ray flux at the Earth’s surface is composed of several types of particles, including neutrons, muons, gamma rays and protons. These particles induce nuclear reactions, generating isotopes that contribute to the radiological background. Underground, the main mechanism of activation is by muon produced spallation neutrons since the hadron component of cosmic rays is removed at depths greater than a few tens of meters. This is a sub-dominant contributor above ground, but muons become predominant in underground experiments. For low-background experiments cosmogenic production of certain isotopes, such as 68Ge and 60Co, must be accounted for in the background budgets. Muons act as minimum ionizing particles, depositing a fixed amount of energy per unit length in a material, and have a very high penetrating power. Using muon flux measurements as a “witness” for the hadron flux, the cosmogenic induced activity can be quantified by correlating the measured muon flux and known hadronic production rates. A publicly available coincident muon cosmic ray detector design, the Berkeley Lab Cosmic Ray Detector (BLCRD), assembled by Juniata College, is evaluated in this work. The performance of the prototype is characterized by assessing its muon flux measurements. This evaluation is done by comparing data taken in identical scenarios with other cosmic ray telescopes. The prototype is made of two plastic scintillator paddles with associated electronics to measure energy depositions in coincidence in the two paddles. For this particular application of the prototype, the measurements performed concentrated on a broad investigation of the dependence of the muon flux on depth underground. These tests were conducted inside at Building 3420/1307 and underground at Building 3425 at the Pacific Northwest National Laboratory. The second half of this report analyzes modifications to the electronics of the BLCRD to make this detector portable. Among other modifications, a battery powered version of these electronics is proposed for the final Muon Witness design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Scintillation-Fiber Based Cosmic-ray Muon Tomography System for Imaging Dry Storage Cask

Because of the growth of the nuclear power industry in the United States and the policy decision to ban reprocessing of commercial spent nuclear fuel, the spent fuel inventory at commercial reactor sites has been increasing. Spent nuclear fuel presents extra complexity of security and proliferation issues. These fuel assemblies are practically inaccessible for inspection purposes, as reopening a DSC would require special facilities and would be tremendously expensive. Cosmic-ray muon Tomography has been studied in the past for various applications and was demonstrated to be a good non-destructive assay technique for high-Z materials, such as spent nuclear fuel assemblies in dry storage casks (DSC). Compared to conventional imaging techniques, muon imaging has some advantages due to its negligible health risk and high penetrating power. In this paper, we report our simulation study on imaging a DSC using muon Tomography technique. The Point of Closest Approach (POCA) and the Maximum-Likelihood Expectation- Maximization (ML-EM) algorithms are implemented and evaluated. A scaled-down prototype muon tomography system is proposed and studied. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MICE: The International Muon Ionization Cooling Experiment: Diagnostic Systems

The Muon Ionization Cooling Experiment will make detailed measurements of muon ionization cooling using a new constructed low-energy muon beam at the Rutherford Appleton Laboratory (RAL). The experiment is a single-particle experiment and utilizes many detector techniques from high energy physics experiments. To characterize and monitor the muon beamline, newly developed scintillating fiber profile monitors and scintillator paddle rate monitors are employed. In order to monitor the purity of the beam and tag the arrival time of individual muons, a dual aerogel Cherenkov system is used, and a plastic scintillator time-of-flight system will be used. The phase-space vectors of the muons will be measured by two identical spectrometer systems (one before and one after the cooling apparatus) which employ a fiber tracker system, and electron and muon calorimeters are used to tag outgoing muons. We will discuss the design of the MICE diagnostic systems, the operation, and give the first results from beam measurements in the MICE experimental hall.

43 PARTICLE ACCELERATORS↗

Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for decays of stopped exotic long-lived particles produced in proton-proton collisions at $\sqrt{s}=$ 13 TeV

A search is presented for the decays of heavy exotic long-lived particles (LLPs) that are produced in proton-proton collisions at a center-of-mass energy of 13 TeV at the CERN LHC and come to rest in the CMS detector. Their decays would be visible during periods of time well separated from proton-proton collisions. Two decay scenarios of stopped LLPs are explored: a hadronic decay detected in the calorimeter and a decay into muons detected in the muon system. The calorimeter (muon) search covers a period of sensitivity totaling 721 (744) hours in 38.6 (39.0) fb$^{−1}$ of data collected by the CMS detector in 2015 and 2016. The results are interpreted in several scenarios that predict LLPs. Production cross section limits are set as a function of the mean proper lifetime and the mass of the LLPs, for lifetimes between 100 ns and 10 days. These are the most stringent limits to date on the mass of hadronically decaying stopped LLPs, and this is the first search at the LHC for stopped LLPs that decay to muons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ TeV

The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal{L}$) of 1 x 10 34 cm –2 s –1 . During the Run 2 data-taking period (2015–2018), the LHC achieved an instantaneous luminosity of twice its design value, resulting in larger background rates and making the efficient detection of muons more difficult. While some backgrounds result from natural radioactivity, cosmic rays, and interactions of the circulating protons with residual gas in the beam pipe, the dominant source of background hits in the muon system arises from proton–proton interactions themselves. Charged hadrons leaving the calorimeters produce energy deposits in the muon chambers. In addition, high-energy particles interacting in the hadron calorimeter and forward shielding elements generate thermal neutrons, which leak out of the calorimeter and shielding structures, filling the CMS cavern. We describe the method used to measure the background rates in the various muon subsystems. These rates, in conjunction with simulations, can be used to estimate the expected backgrounds in the High-Luminosity LHC. This machine will run for at least 10 years starting in 2029 reaching an instantaneous luminosity of $\mathcal{L}$ = 5 x 10 34 cm –2 s –1 and increasing ultimately to $\mathcal{L}$ = 7.5 x 10 34 cm –2 s –1 . These background estimates have been a key ingredient for the planning and design of the muon detector upgrade.

Tytgat, M. (ORCID:0000000239902074)↗