Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multizone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of a Multizone Impedance Eduction Method

A computational study is used to evaluate the PyCHE impedance eduction method developed at the NASA Langley Research Center. This method combines an aeroacoustic duct propagation code based on numerical solution to the convected Helmholtz equation with a global optimizer that uses the Differential Evolution algorithm. The efficacy of this method is evaluated with acoustic pressure data simulated to represent that measured with one-zone, two-zone, and three-zone liners mounted in the NASA Langley Grazing Flow Impedance Tube. The PyCHE method has a normalized impedance error of approximately 0.2 for (uniform) one-zone liners with a length of at least 5”, and produces quite reasonable results for liners as short as 2”. Whereas the impedance of the liner has an effect on eduction accuracy, the amount of attenuation is shown to be the dominant parameter. Similar results are observed for two-zone liners, for which the impedance of each zone is unique. The two-zone results also indicate it is more difficult to accurately educe resistance than reactance, and a zone length of at least 6” (slightly longer than for uniform liners) is needed to limit the normalized error to 0.2. The PyCHE method is also demonstrated to successfully educe the impedances for each zone of a three-zone liner. These results are sufficiently encouraging to warrant the continued usage of the PyCHE impedance eduction method for single and multizone liners.

Jones, M. G.↗

Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building

The dispersion of indoor airborne contaminants across different zones within a mechanically ventilated building is a complex phenomenon driven by multiple factors. In this study, we modeled the indoor dispersion of airborne SARS-CoV-2 aerosols within a US Department of Energy detailed medium office prototype building using CONTAM software. The aim of this study is to improve our understanding about how different parts of a building can experience varying concentrations of the airborne viruses under different circumstances of release and mitigation strategies. Results indicate that unventilated stairwells can have significantly higher concentrations of airborne viruses. The mitigation strategies of morning and evening flushing of conditioned zones were not found to be very effective. Instead, a constant high percentage of outdoor air in the supply mix, and the use of masks, portable HEPA air cleaners, MERV 13 or higher HVAC air filters, and ultraviolet germicidal irradiation disinfection were effective strategies to prevent airborne viral contamination in the majority of the simulated office building.

60 APPLIED LIFE SCIENCES↗

Multizone Residential HVAC Modeling

This report will evaluate several building physics modeling tools to determine which are best suited for developing next-generation zoning technology. These modeling tools will be evaluated for their ability to predict room-level thermal loads, HVAC system operation, temperature and comfort predictions, and scalability. Any gaps in the existing tools will be identified and a path forward will be discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Program for integrating multizonal photographs of the Earth, taken by MKF-6 camera, in a computer

An algorithm and program are described, for integrating up to 6 simultaneously exposed photographs in different spectral ranges of the surface of the Earth, taken by MKF-6 cameras aboard Soyuz-22. Three of the reference marks are identified on 1 photograph and then are used to integrate the other photographs with the first. The program was compiled for the ES-1040 computer, as a standard subprogram in a system for computer processing of data of study of the Earth from space.

Agapov, A. V.↗

Programmable Multizone Furnace

Moving thermal gradients created without mechanical motion. Furnace having multiple, individually programmable heating zones developed for use in experiments on directional solidification. Holds rod specimen and generates thermal gradients moving along specimen. Elimination of translation mechanism makes furnace more compact and reduces vibrations, which disturb experiment. Availability of different temperature profiles through programming makes it versatile tool for research at low thermal gradients traveling at moderate speeds.

Ting, Edmund Y.↗

Multizone accretional evolution of planetesimal swarms

The general features of a new numerical simulation of planetesimal accretion which models multiple heliocentric distance zones, together with a detailed model for the planetesimal size and orbital distribution in each zone, are described. A restricted version of this model which allows only a single heliocentric distance zone has been used to test the validity of the code by comparing with results from earlier authors when the same physical phenomena are included. Generally, very good agreement is found.

Spaute, D.↗

Conservative multizonal interface algorithm for the 3-D Navier-Stokes equations

A conservative zonal interface algorithm using features of both structured and unstructured mesh CFD technology is presented. The flow solver within each of the zones is based on structured mesh CFD technology. The interface algorithm was implemented into two three-dimensional Navier-Stokes finite volume codes and was found to yield good results.

Klopfer, G. H.↗

MUZO flight experience with the programmable multizone furnace

The Multi-Zone (MUZO) furnace has been developed for growing germanium (Ge) crystals under microgravity in a Get Away Special (GAS) payload. The MUZO furnace was launched with STS-47 Endeavour in September 1992. The payload worked as planned during the flight and a Ge sample was successfully processed. The experiment has given valuable scientific information. The design and functionality of the payload together with flight experience is reported.

Lockowandt, Christian↗

Development of Advanced Multizone Facilities for Microgravity Processing

NASA has been interested in experimental ground based study to investigate the fundamental processes involved in phase transformation processes during growth of metallic, nonmetallic and electronic materials. Solidification, vapor growth and solution growth techniques of growing crystals are of special interest because of the inherent importance of convection in the nutrient solution. Convection enhances the mass transport through the nutrient and results in faster growth rates. Availability of low gravity environment of space has provided scientists a new variable to control the extent of convection and thus isolate the diffusive phenomena for their better understanding. The thermal gradient at the liquid-solid interface is determined by the alloy characteristics, the hot zone temperature, cold zone temperature and the width of the insulating zone. The thermal profiles get established by the existing material and geometrical constraints of the experimental set up. The major effort under this research was devoted to designing a programmable furnace which can be used to obtain thermal profiles along the length of the sample as per the demands of the scientists. The furnace did not have active cooling of the zones. Only active heating and passive cooling were utilized.

Source record↗

Sensor Impact Evaluation at Different Sensor Locations in a Multi-zone Office Building

FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of potential aerosol transmission and infectivity of SARS-CoV-2 through central ventilation systems

Here we evaluate the concentrations and probabilities of infection for both building interior and exterior exposure sources using a well-mixed model in a connected multizone building. As a central hub of many community and economic activities, buildings provide social connectivity, but the COVID-19 pandemic has reduced social connectivity due to concerns of viral spread within buildings. Although single zone models of infectious spread are well studied, the impact of aerosolized spread of SARS-CoV-2 via air handling systems in multizone buildings remains unexplored. Here we evaluate the influence of filtration, air exchange rates, and the fraction of outdoor air on the probability of infection using the well-known well-mixed modeling approach for a multizone. We find filtration lowers the concentration and probability of infection in both source and connected rooms provided at least some air is recirculated, but that probability is not zero. Filtration has no influence without recirculation or unless the outdoor air contains virus. We find that increasing the air exchange rate removes virus from the source room faster but also increases the rate of exposure to connected rooms. Therefore, slower air exchange rates reduce infectivity in connected rooms at shorter durations, but higher air exchange rates reduce infectivity at longer durations. We further find that when outdoor air is virus free, increasing the fraction of outdoor air is helpful, but, when outdoor air is infective, pathogen exposure inside can persist for hours after a short-term release.

60 APPLIED LIFE SCIENCES↗

Heat transfer on accreting ice surfaces

Based on previous observations of glaze ice accretion on aircraft surfaces, a multizone model with distinct zones of different surface roughness is demonstrated. The use of surface roughness in the LEWICE ice accretion prediction code is examined. It was found that roughness is used in two ways: (1) to determine the laminar to turbulent boundary-layer transition location; and (2) to calculate the convective turbulent heat-transfer coefficient. A two-zone version of the multizone model is implemented in the LEWICE code, and compared with experimental convective heat-transfer coefficient and ice accretion results. The analysis of the boundary-layer transition, surface roughness, and viscous flowfield effects significantly increased the accuracy in predicting heat-transfer coefficients. The multizone model was found to significantly improve the ice accretion prediction for the cases compared.

Yamaguchi, Keiko↗

Revisiting High-Energy Polarization from Leptonic and Hadronic Blazar Scenarios

X-ray and MeV polarization can be powerful diagnostics for leptonic and hadronic blazar models. Previous predictions are mostly based on a one-zone framework. However, recent IXPE observations of Mrk 421 and 501 strongly favor a multizone framework. Thus, the leptonic and hadronic polarization predictions need to be revisited. Here we identify two generic radiation transfer effects, namely, double depolarization and energy stratification, that can have an impact on the leptonic and hadronic polarization. We show how they are generalized from previously known multizone effects of the primary electron synchrotron radiation. Under our generic multizone model, the leptonic polarization degree is expected to be much lower than the one-zone prediction, unlikely detectable in most cases. The hadronic polarization degree can reach a value as high as the primary electron synchrotron polarization during simultaneous multiwavelength flares, consistent with the one-zone prediction. Therefore, IXPE and future X-ray and MeV polarimeters such as eXTP, COSI, and AMEGO-X, have good chances to detect hadronic polarization during flares. However, the hadronic polarization cannot be well constrained during the quiescent state. Nonetheless, if some blazar jets possess relatively stable large-scale magnetic structures, as suggested by radio observations, a nontrivial polarization degree may show up for the hadronic model after a very long exposure time (≳1 yr).

Haocheng Zhang↗

Pressure Modification or Barrier Issues during Polymer Flooding Enhanced Oil Recovery

Effective oil displacement from a reservoir requires adequate and properly directed pressure gradients in areas of high oil saturation. If the polymer bank is too large or too viscous during a polymer flood, the pressure drops from the injection well to the polymer front may act as a pressure modification or barrier by usurping most of the downstream driving force for oil displacement. Polymer injection pressures must be limited. The maximum allowable injection pressure is commonly constrained by caprock integrity, injection equipment, and/or regulations, even though fractures can be beneficial to polymer injectivity. This paper examines when the pressure-barrier concept limits the size and viscosity of the polymer bank during a polymer flood. Analytical and numerical methods are used to address this issue. We examine the relevance of the pressure modification concept for a wide variety of circumstances, including oil viscosities ranging from 10 cp to 1650 cp, vertical wells versus horizontal wells, single versus multiple layered reservoirs, permeability contrast, and crossflow between layers. We also examine the relation between the pressure-barrier concept and fractures and fracture extension during polymer injection. We demonstrate that in reservoirs with single layers, the pressure-barrier concept only limits the optimum viscosity of the injected polymer if the mobility of the polymer bank is less than the mobility of the displaced oil bank. The same is true for multizoned reservoirs with no crossflow between layers. Thus, for these cases, the optimum polymer viscosity is likely to be dictated by the mobility of the oil bank, unless other factors intervene. For multizoned reservoirs with free crossflow between layers, the situation is different. A compromise must be reached between injected polymer viscosity and the efficiency of oil recovery. This work is particularly relevant to viscous oil reservoirs where polymer viscosities are substantially lower than the oil viscosity.

58 GEOSCIENCES↗