26 records · Page 2

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting

InAs sidewall tunnel diodes enabled by surface states

Negative differential resistance (NDR), where the device current decreases with increasing bias voltage, is a representative phenomenon where quantum mechanics induces counterintuitive physical behavior and offers promising applications such as high-frequency oscillators, amplifiers, and multilevel logic circuits. While the NDR behavior has been extensively studied in various materials and devices, the role of surface properties in NDR, particularly in InAs-based diodes, remains underexplored. In this work, we report the observation of NDR in vertically structured InAs p + n diodes that exhibit a peak-valley current ratio of ∼6, which is suitably high for applications. Circumference-normalized current–voltage characterization revealed that the NDR originates from band-to-band tunneling between the valence band of p + -InAs and the conduction band of an n + -InAs surface, where the n + surface is due to surface states on otherwise n − -InAs. In addition, by comparing devices with various surface passivation methods (without intentional passivation, benzocyclobutene polymer, and silicon nitride), we found that the surface termination significantly affects the NDR characteristics. We present an equivalent circuit model to explain the observed device behavior. These findings offer insights into surface-enabled NDR phenomena and present new knobs for engineering NDR devices.

Circuit theorems

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Sub-Doppler Cooling of a Trapped Ion in a Phase-Stable Polarization Gradient

Trapped ions provide a highly controlled platform for quantum sensors, clocks, simulators, and computers, all of which depend on cooling ions close to their motional ground state. Existing methods like Doppler, resolved sideband, and dark resonance cooling balance trade-offs between the final temperature and cooling rate. A traveling polarization gradient has been shown to cool multiple modes quickly and in parallel, but utilizing a stable polarization gradient can achieve lower ion energies, while also allowing tailorable light-matter interactions in the sub-wavelength regime. In this Letter, we demonstrate cooling of a trapped ion below the Doppler limit using a phase-stable polarization gradient created using trap-integrated photonic devices. At an axial frequency of 2⁢𝜋×1.45 MHz we achieve ⟨𝑛⟩=1.56±0.07 in 150 μ⁢s and cooling rates of ∼0.3 quanta/μ⁢s. Here, we examine ion dynamics under different polarization gradient phases, detunings, and intensities, showing reasonable agreement between experimental results and a multilevel model. Cooling is fast and power efficient, with lower average motional Fock state occupation when compared to simulated operation under the corresponding running wave configuration. Our results demonstrate a well-controlled test bed for studying the dynamics of multilevel atomic systems in a phase-stable polarization gradient.

Atom & ion cooling

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport