Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multi Attribute Utility Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multi–LDAP Dynamic User Management Tool Utilizing Oracle Application Express and PL/SQL

A Center for Infrastructure Security Analysis (CISA) client system required support of multiple Lightweight Directory Access Protocol (LDAP) directories for multiple, varied user communities. The LDAP directories were all based upon different technologies, i.e., Microsoft Active Directory (AD), Microsoft Active Directory Lightweight Directory Services (ADLDS), and Oracle Internet Directory (OID), depending on system setup, security requirements, and legacy software. Research revealed that PL/SQL provided the capability to execute dynamic PL/SQL and SQL blocks. The dynamic capabilities were utilized along with several configuration tables to provide an object-oriented, polymorphic-like behavior. This architecture was chosen so that a top-level application programming interface (API) could be defined for all calls, no matter what type of LDAP was being manipulated, as each LDAP type has slightly different attributes and requirements. The dynamic nature of the user management system allowed for easy setup and utilization of any new LDAP directories, minimizing the time and effort expended on system changes.

97 MATHEMATICS AND COMPUTING↗

Schema Elements for Granta Annual Report: FY2024

Granta: Materials Intelligence (Granta: MI) is a commercial database software distributed by Ansys, Inc. that is utilized by the Nuclear Security Enterprise (NSE) to organize and store relevant materials data. Lack of standard and well-documented database schema is the primary obstacle to an NSE materials data management solution, so the objective of this project is to create and document such a schema. In FY21, an approach for designing, documenting, and managing a standard database schema was described based on the creation of schema elements (collections of attributes used to describe particular aspects of the data) to be used as building blocks for creating various database tables without duplication. In FY22, these methods were applied through a multi-site collaboration to create and document the schema elements necessary to build a thermogravimetric analysis (TGA) testing table. In FY23 the schema was expanded to include elements for a differential scanning calorimetry (DSC) table, along with schema for supporting metadata tables including Instruments, Projects, Documents, and Testing Series. In FY24 the following progress was made, again through multi-site collaboration: • The existing schema elements were modified to accommodate thermomechanical analysis (TMA) data, and a table, Test Data: TMA, was created for managing TMA data. • The elements necessary for the following additive manufacturing (AM) data tables (directed at data specific to selective laser sintering AM technology) were created: • AM Builds • AM Processes • AM Part Designs • Built AM Parts • AM Feedstock Materials • AM Feedstock Material Batches • The elements necessary for creating a Calibrated Material Models table were created, and the Calibrated Material Models table was created. In FY25 the existing schema will be deployed on the production enterprise Granta instance on the enterprise secure network. Schema elements will be appended, and new elements created as necessary, to allow the creation of tables specifically to support materials testing, AM process development, and design and analysis for modernization programs.

36 MATERIALS SCIENCE↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for CSP- Fabrication and Testing of Receiver Design Feature Specimens in a Simulating Lab Test via Laser Heating

Critical to the creation of a multi-component SiC receiver design concept capable of meeting the SETO CST cost goal objectives of <$150/kWth is the optimal utilization of material for solar absorption and heat transfer to transport fluid. This is to maximize the solar-thermal efficiency in the techno-economic analysis of derived use case. As a first step in preparation of sub-component design for on-sun test evaluations we use different proposed SiC absorber element in a customized laser heat flux test to assess an effective heat transfer coefficient characteristic of the design. The test results are analyzed to extract the effective heat transfer coefficient, thus enable optimization of the geometry of receiver components for heat transfer, efficiency attributes and the thermo-structural management of the components. High intensity CO2 laser is used in combination with air flow through the test specimen to assess the effective heat transfer coefficient under heat flux conditions corresponding to high solar concentrations in the range of 1000-2000 suns.

14 SOLAR ENERGY↗

GIS Supported Optimal Site Selection for Coastal Structure Integrated Wave Energy Converters: Preprint

There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.

coastal protection↗

DEMONSTRATION OF MULTI-PHYSICS EVALUATION OF FUEL ROD BURST PROBABILITY WITH BURNUP EXTENSION UNDER LBLOCA CONDITIONS

Extending the fuel discharge burnup level, e.g., from the current limit of rod averaged discharge burnup limit of 62 GWD/MT to a proposed new limit of 75 GWD/MT, can provide significant economic benefits to the current fleet of operating light water reactors (LWRs). It allows for longer operating cycles and improved resource utilization. The major economic gain of longer operating cycles is attributable to the increased capacity factor resulting from decreased refueling time as a fraction of total operating time, as well as fewer assemblies to be discharged for a given amount of energy produced. The main licensing challenges for higher burnup fuel are to ensure fuel rod safety under design basis accident conditions, especially under large-break loss-of-coolant accident (LBLOCA) and reactivity insertion accident (RIA). In this work, two-year cycle core design for a typical 4-loop pressurized water reactor (PWR) is performed with enrichment increased up to 6% and burnup extended to 75 GWD/MT. The fuel rod burst potential evaluations under large-break loss-of-coolant accident (LBLOCA) conditions are subsequently performed using the multi-physics best estimate plus uncertainty analysis framework LOTUS (LOCA Toolkit for the U.S. LWRs) and the preliminary results are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $\$ $275 to $\$ $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raleigh Housing Authority Duct Sealing Evaluation

In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealant (Aeroseal) in combination with some manual sealing were implemented in several low-rise multi-unit buildings in North Carolina. An analysis of the cost and performance of the two methods is presented. Each method was used in 20 housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where a combination of injected spray sealant and manual sealing was used. Some of this difference is likely due to the fact that injected spray sealing reached portions of the duct system that were inaccessible to manual methods. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns, and the air handler. The cost of manually applying sealant ranged from $275 to $511 per unit and for the Aeroseal treated ducts the cost was $700 per unit. Utility bills were collected and compared for 1 year before and after the retrofits for each unit. Energy savings based on utility bills were within 25%-50% of those predicted by the models for most unit types. Utility bill analysis shows 14% and 16% energy savings using the Aeroseal and hand sealing procedures, respectively, in heating season whereas in cooling season, energy savings using Aeroseal and hand sealing were both 16%. Average simple payback based on utility bills was 2.2 years for manual units and 4.7 years for the Aeroseal units. Only 18 of 40 units had usable utility bills. Berkshire Village Court - House Count - 4: Single Story, Hand sealed ducts; Single Story, Aeroseal Ducting; 2-Story, Hand Sealed ducts; 2-Story, Aeroseal ducts Terrace Park Court - House Count - 2: Single Story, Hand sealed ducts; Double Story, Hand sealed ducting Winter Park Court - House Count - 2: Single Story, Hand sealed ducts, Aeroseal sealed ducting; Double Story, Aeroseal ducting

Aeroseal↗

EPRI Demonstration of an Autonomous Site Characterization Vehicle - 20523

A substantial effort is applied in performing radiological characterization of structures and land areas during decommissioning of a nuclear facility. This includes multiple surveys of land areas and large structures to support eventual site release under the Multi Agency Survey and Site Investigation Manual (MARSSIM, Reference 1). These surveys are typically performed using manually delivered systems, which is time consuming and labor intensive. Radiological surveys intentionally follow a prescribed protocol with respect to areas covered, scan speeds, responses to elevated readings, required detector offsets, the need for repeat measurements, etc. Based on these attributes, combined with the repetitive effort of performing surveys over large areas, automation of radiological characterization techniques has a high potential to be successful and promises substantial benefit. EPRI has performed a project that resulted in the development and demonstration of an autonomous site characterization system. This EPRI project focused on building surfaces and the surfaces of large land areas as these configurations lend themselves more readily to automated survey. The project included: - Identification of the requirements for an autonomous site characterization system; - A survey of existing control systems that use automation to conduct characterization of structures and land areas. - As no fully adequate systems were identified, a complete system was developed that utilized commercially available detection and analysis systems and a self driving vehicle owned by EPRI. The system was demonstrated at the Kewaunee nuclear power plant site in the fall of 2019. The demonstration included: - Autonomous surveys of floor areas inside the Auxiliary Building at Kewaunee after manually controlled mapping of the survey areas. - For land areas, the vehicle autonomously surveyed areas using travel paths had been preprogrammed onto an internet available map of area. In this case, GPS coordinates from the preprogramming were used for navigation by the vehicles guidance system. This paper summarizes the characterization system development and system demonstration which will also be published in an EPRI report in the first half of 2020. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-year analysis of physical interactions between solar PV arrays and underlying soil-plant complex in vegetated utility-scale systems

Concerns over the land use changes impacts of solar photovoltaic (PV) development are increasing as PV energy development expands. Co-locating utility-scale solar energy with vegetation may maintain or rehabilitate the land's ability to provide ecosystem services. Previous studies have shown that vegetation under and around the panels may improve the performance of the co-located PV and that PV may create a favorable environment for the growth of vegetation. While there have been some pilot-scale experiments, the existence and magnitude of these benefits of vegetation has not been confirmed in a utility-scale PV facility over multiple years. In this study we use power output data coupled with microclimatic measurements in temperate climates to assess these potential benefits. Here this study combines multi-year microclimatic measurements to analyze the physical interactions between PV arrays and the underlying soil-vegetation system in three utility-scale PV facilities in Minnesota, USA. No significant cooling of PV panels or increased power production was observed in PV arrays with underlying vegetation. Fine soil particle fraction was the highest in soils within PV arrays with the vegetation which was attributable to the lowest wind speeds from the compounding suppression of wind by vegetation and PV arrays. Soil moisture and soil nutrient response to re-vegetation varied between PV facilities, which could be attributed to differing soil texture. No statistically significant vegetation-driven panel cooling was observed in this climate. This finding prompts a need for site-specific studies to identify contributing factors for environmental co-benefits in co-located systems.

14 SOLAR ENERGY↗

Multi-technology building system retrofits for utility incentive programs: Savings, costs and baseline considerations

Utility incentive programs are an important channel to support the deployment of energy efficiency in buildings. To date, these programs have largely been limited to single-component strategies. However, many utilities are now motivated to identify and develop multi-component system retrofits to achieve deeper energy savings, which are essential to achieving broader energy and greenhouse gas reduction goals in the buildings sector. In this paper we present the energy savings, demand reductions, and cost-effectiveness of 16 systems retrofit packages in six utility regions in the United States. These results are being used by these utilities to inform and develop incentive programs for systems retrofits. Our analysis shows that packages with proven lighting and HVAC measures can provide 5–22% whole building annual energy savings, and 13–22% annual energy costs savings, using utility incentive program baselines (code and existing building). The packages are reasonably cost effective for replace-on-burnout but generally not for a retrofit scenario prior to end of equipment life. Demand response can increase both the energy savings and energy cost savings, further improving the cost effectiveness of these packages. We analyzed the impact of using existing building vs. code baselines for calculating savings, showing that the choice of baseline in developing utility incentive programs has a substantial impact on the attributable energy savings to a program, with significant implications for the overall viability of a program (generally savings against existing building condition are higher and improve project and program cost-effectiveness).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TH-CD-202-07: A Methodology for Generating Numerical Phantoms for Radiation Therapy Using Geometric Attribute Distribution Models

Purpose: A persistent challenge for the quality assessment of radiation therapy treatments (e.g. contouring accuracy) is the absence of the known, ground truth for patient data. Moreover, assessment results are often patient-dependent. Computer simulation studies utilizing numerical phantoms can be performed for quality assessment with a known ground truth. However, previously reported numerical phantoms do not include the statistical properties of inter-patient variations, as their models are based on only one patient. In addition, these models do not incorporate tumor data. In this study, a methodology was developed for generating numerical phantoms which encapsulate the statistical variations of patients within radiation therapy, including tumors. Methods: Based on previous work in contouring assessment, geometric attribute distribution (GAD) models were employed to model both the deterministic and stochastic properties of individual organs via principle component analysis. Using pre-existing radiation therapy contour data, the GAD models are trained to model the shape and centroid distributions of each organ. Then, organs with different shapes and positions can be generated by assigning statistically sound weights to the GAD model parameters. Organ contour data from 20 retrospective prostate patient cases were manually extracted and utilized to train the GAD models. As a demonstration, computer-simulated CT images of generated numerical phantoms were calculated and assessed subjectively and objectively for realism. Results: A cohort of numerical phantoms of the male human pelvis was generated. CT images were deemed realistic both subjectively and objectively in terms of image noise power spectrum. Conclusion: A methodology has been developed to generate realistic numerical anthropomorphic phantoms using pre-existing radiation therapy data. The GAD models guarantee that generated organs span the statistical distribution of observed radiation therapy patients, according to the training dataset. The methodology enables radiation therapy treatment assessment with multi-modality imaging and a known ground truth, and without patient-dependent bias.

60 APPLIED LIFE SCIENCES↗

Advances in rapid compression machine studies of low- and intermediate-temperature autoignition phenomena

Rapid compression machines (RCMs) are widely-used to acquire experimental insights into fuel autoignition and pollutant formation chemistry, especially at conditions relevant to current and future combustion technologies. RCM studies emphasize important experimental regimes, characterized by low- to intermediate-temperatures (600–1200 K) and moderate to high pressures (5–80 bar). At these conditions, which are directly relevant to modern combustion schemes including low temperature combustion (LTC) for internal combustion engines and dry low emissions (DLE) for gas turbine engines, combustion chemistry exhibits complex and experimentally challenging behaviors such as the chemistry attributed to cool flame behavior and the negative temperature coefficient regime. Challenges for studying this regime include that experimental observations can be more sensitive to coupled physical-chemical processes leading to phenomena such as mixed deflagrative/autoignitive combustion. Experimental strategies which leverage the strengths of RCMs have been developed in recent years to make RCMs particularly well suited for elucidating LTC and DLE chemistry, as well as convolved physical-chemical processes. Specifically, this work presents a review of experimental and computational efforts applying RCMs to study autoignition phenomena, and the insights gained through these efforts. A brief history of RCM development is presented towards the steady improvement in design, characterization, instrumentation and data analysis. Novel experimental approaches and measurement techniques, coordinated with computational methods are described which have expanded the utility of RCMs beyond empirical studies of explosion limits to increasingly detailed understanding of autoignition chemistry and the role of physical-chemical interactions. Fundamental insight into the autoignition chemistry of specific fuels is described, demonstrating the extent of knowledge of low-temperature chemistry derived from RCM studies, from simple hydrocarbons to multi-component blends and full-boiling range fuels. In conclusion, emerging needs and further opportunities are suggested, including investigations of under-explored fuels and the implementation of increasingly higher fidelity diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing and Evaluating Multithreaded Triad Census Algorithms on the Cray XMT

Commonly represented as directed graphs, social networks depict relationships and behaviors among social entities such as people, groups, and organizations. Social network analysis denotes a class of mathematical and statistical methods designed to study and measure social networks. Beyond sociolo-gy, social network analysis methods are being applied to other types of data in other domains such as bioinformatics, computer networks, national security, and economics. For particular problems, the size of a social network can grow to millions of nodes and tens of millions of edges or more. In such cases, researchers could benefit from the application of social network analysis algorithms on high-performance architectures and systems. The Cray XMT is a third generation multithreaded system based on the Cray XT-3/4 platform. Like most other multithreaded architectures, the Cray XMT is designed to tolerate memory access latencies by switching context between threads. The processors maintain multiple threads of execution and util-ize hardware-based context switching to overlap the memory latency incurred by any thread with the computations from other threads. Due to its memory latency tolerance, the Cray XMT has the poten-tial of significantly improving the execution speed of irregular data-intensive applications such as those found in social network analysis. In this paper, we describe our experiences in developing and optimizing three implementations of a social network analysis method known as triadic analysis to execute on the Cray XMT. The three im-plementations possess different execution complexities, qualities, and characteristics. We evaluate how the various attributes of the codes affect their performance on the Cray XMT. We also explore the effects of different compiler options and execution strategies on the different triadic analysis im-plementations and identify general XMT programming issues and lessons learned.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Anthropogenic Markers in Alta Irrigation District Water Supply Wells

In July 2016, LLNL produced a report for the Kings River Watershed Coalition Authority (KRWCA) entitled “Groundwater Age and Nitrate Isotopic Composition in Alta Irrigation District Water Supply Wells” (Esser et al., 2016). That report summarized groundwater age and nitrate isotopic composition data produced by LLNL for Alta Irrigation District (AID) groundwater wells sampled by KRWCA in a pilot project to test the utility of advanced isotopic methods for constraining the timing and source of nitrate in groundwater at selected sites in the Kings River service area. One section of that report made recommendations for follow-on study. The first and strongest recommendation was to measure a wider suite of source tracers including co-contaminants such as herbicides, pesticides, pharmaceuticals, personal care products, and food constituents and additives. KRWCA followed up on this recommendation in Phase II of the pilot study by re-sampling the original set of wells and submitting the samples to a commercial laboratory for analysis of a limited range of co-contaminants (including pharmaceuticals, personal care products , and food constituents and additives, but not including herbicides or pesticides). They have asked that LLNL review and interpret these data in the context of previous LLNL analyses and to evaluate the utility of such co-contaminant analyses in providing additional constraints on the source of groundwater nitrate contamination in Alta Irrigation District water supply wells. The goal of the second phase of this pilot project is to evaluate the utility of co-contaminant occurrence for constraining nitrate source in groundwater at selected sites in the Kings River service area, with special reference to the use of such data in conjunction with advanced isotopic methods such as nitrate isotopic composition and groundwater age. Nitrate isotopic composition alone cannot distinguish nitrate derived from animal manure from nitrate derived from human septic waste. The presence or absence of agricultural chemicals (herbicides, pesticides, veterinary pharmaceuticals) or chemicals associated with people (human pharmaceuticals, artificial sweeteners) can help make this distinction. Co-contaminant analyses using multi-analyte LC-MS-MS protocols are now commercially available and reasonably priced. The feasibility and utility of the using co-contaminants for nitrate source attribution can be evaluated by 1) determining the degree to which co-contaminants occur in distinct and easily attributable groupings (e.g. agricultural chemicals vs personal care products and food additives); 2) determining the degree to which co-contaminant occurrence is consistent with nitrate isotopic composition and groundwater age (e.g. no co-contaminant occurrence in very old groundwater; co-contaminants consistent with animal manure or human septic waste occurring in groundwaters having nitrate isotopic composition also consistent with animal manure or human septic waste); and 3) determining the degree to which co-contaminants provide additional constraint on nitrate source over and beyond nitrate isotopic composition and groundwater age (e.g. distinguishing between animal manure and human septic waste).

58 GEOSCIENCES↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Application of Multi-Criteria Decision Analysis Techniques for Informing Select Agent Designation and Decision Making

The Centers for Disease Control and Prevention (CDC) Select Agent Program establishes a list of biological agents and toxins that potentially threaten public health and safety, the procedures governing the possession, utilization, and transfer of those agents, and training requirements for entities working with them. Every 2 years the Program reviews the select agent list, utilizing subject matter expert (SME) assessments to rank the agents. In this study, we explore the applicability of multi-criteria decision analysis (MCDA) techniques and logic tree analysis to support the CDC Select Agent Program biennial review process, applying the approach broadly to include non-select agents to evaluate its generality. We conducted a literature search for over 70 pathogens against 15 criteria for assessing public health and bioterrorism risk and documented the findings for archiving. The most prominent data gaps were found for aerosol stability and human infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. Analysis of results obtained from a two-dimensional plot of weighted scores for difficulty of attack (i.e., exposure and production criteria) vs. consequences of an attack (i.e., consequence and mitigation criteria) provided greater fidelity for understanding agent placement compared to a 1-to-n ranking and was used to define a region in the upper right-hand quadrant for identifying pathogens for consideration as select agents. A sensitivity analysis varied the numerical weights attributed to various properties of the pathogens to identify potential quantitative (x and y) thresholds for classifying select agents. The results indicate while there is some clustering of agent scores to suggest thresholds, there are still pathogens that score close to any threshold, suggesting that thresholding “by eye” may not be sufficient. The sensitivity analysis indicates quantitative thresholds are plausible, and there is good agreement of the analytical results with select agent designations. A second analytical approach that applied the data using a logic tree format to rule out pathogens for consideration as select agents arrived at similar conclusions.

60 APPLIED LIFE SCIENCES↗