Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

Microgravity Electrical Capacitance Tomography Data Set

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that has been used in the oil/gas industry for decades to measure multi-phase flow rate in pipes. ECT, when installed in a tank, is able to reconstruct the liquid distribution inside of the tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing on the ground, and while ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT tank liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. The experiment hardware was rented from a company; NASA LSP did no technology development work for this project. This STRIVES entry is for the entire raw data set, which consists of approximately 25GB of csv files of capacitance and motion data from the ground and flight tests of the experiment. The data set will be available on the NASA LSP Electronic Slosh Data Catalog (ESDC), and the public may request the data set from the authors (POC: Jed Storey, jedediah.m.nasa.gov).

mass gauging↗

Internal Structure of the Central Garlock Fault Zone From Ridgecrest Aftershocks Recorded by Dense Linear Seismic Arrays

Abstract We provide high‐resolution seismic imaging of the central Garlock fault using data recorded by two dense seismic arrays that cross the Ridgecrest rupture zone (B4) and the Garlock fault (A5). Analyses of fault zone head waves and P ‐wave delay times at array A5 show that the Garlock fault is a sharp bimaterial interface with P waves traveling ∼5% faster in the northern crustal block. The across‐fault velocity contrast agrees with regional tomography models and generates clear P ‐wave reflections in waveforms recorded by array B4. Kirchhoff migration of the reflected waves indicates a near‐vertical fault between 2 and 6 km depth. The P ‐wave delay times imply a ∼300‐m‐wide transition zone near the Garlock fault surface trace beneath array A5, offset to the side with faster velocities. The results provide important constraints for derivations of earthquake properties, simulations of ruptures and ground motion, and future imaging studies associated with the Garlock fault.

58 GEOSCIENCES↗

Electric-field-assisted-sintering of rare-earth oxide dispersion strengthened Fe-Cr-Mo alloys

Oxide dispersion-strengthened (ODS) alloys are widely recognized for their exceptional high-temperature strength, creep resistance, and radiation tolerance, making them indispensable for advanced nuclear reactors, aerospace, and energy systems. Achieving a fine and stable dispersion of oxide nanoparticles is critical, as these particles act as strong barriers to dislocation motion and effective sinks for irradiation-induced defects, ensuring structural integrity under extreme conditions. Here, in this study, Fe–Cr–Mo-based ODS alloys were fabricated via mechanical alloying and consolidated using electric-field-assisted sintering (EFAS) with additions of Y 2 O 3 , La 2 O 3 , and CeO 2 . EFAS processing produced ultrafine-grained microstructures (average grain size <1 μm) with uniformly distributed oxide clusters (2–4 nm). Atom probe tomography revealed that La 2 O 3 -containing alloys exhibited the highest nanoparticle number density, resulting in superior tensile strength compared to yttria- and ceria-bearing counterparts. The combined effect of grain refinement and rare-earth oxide dispersion significantly enhanced mechanical performance, demonstrating the potential of EFAS for developing high-strength ferritic alloys for demanding environments such as nuclear systems.

36 - MATERIALS SCIENCE↗

Reconstruction of the mutual coherence function for a moving source

The acoustic radiation of a randomly fluctuating source in motion is characterized analytically to determine the mutual coherence function (MCF). A far-field relation is derived via a series of invertible transformations, and a higher-dimension Radon transformation is performed to reconstruct the MCF; explicit formulas for computing the MCF from the transformed radiation data are provided. The technique is applied to the cases of an axisymmetric line source of finite extent moving at constant velocity along a line and a spatially incoherent line source. Applications to X-ray tomography and analysis of the noise emitted by a moving jet aircraft are suggested.

Chow, P. L.↗

CryoDRGN-AI: neural ab initio reconstruction of challenging cryo-EM and cryo-ET datasets

Proteins and other biomolecules form dynamic macromolecular machines that are tightly orchestrated to move, bind, and perform chemistry. Cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET) can access the intrinsic heterogeneity of these complexes and are therefore key tools for understanding their function. However, 3D reconstruction of the collected imaging data presents a challenging computational problem, especially without any starting information, a setting termed ab initio reconstruction. Here, in this study, we introduce cryoDRGN-AI, a method leveraging an expressive neural representation and combining an exhaustive search strategy with gradient-based optimization to process challenging heterogeneous datasets. Using cryoDRGN-AI, we reveal new conformational states in large datasets, reconstruct previously unresolved motions from unfiltered datasets, and demonstrate ab initio reconstruction of biomolecular complexes from in situ data. With this expressive and scalable model for structure determination, we hope to unlock the full potential of cryo-EM and cryo-ET as a high-throughput tool for structural biology and discovery.

Levy, Axel [Stanford Univ., CA (United States); SL↗

Particle image velocimetry experiments for the IML-I spaceflight

The first International Microgravity Laboratory (IML-1), scheduled for spaceflight in early 1992 includes a crystal-growth-from-solution experiment which is equipped with an array of optical diagnostics instrumentation which includes transmission and reflection holography, tomography, schlieren, and particle image displacement velocimetry. During the course of preparation for this spaceflight experiment we have performed both experimentation and analysis for each of these diagnostics. In this paper we describe the work performed in the development of holographic particle image displacement velocimetry for microgravity application which will be employed primarily to observe and quantify minute convective currents in the Spacelab environment and also to measure the value of g. Additionally, the experiment offers a unique opportunity to examine physical phenomena which are normally negligible and not observable. A preliminary analysis of the motion of particles in fluid was performed and supporting experiments were carried out. The results of the analysis and the experiments are reported.

Trolinger, J. D.↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Ultrafast Molecular Frame Quantum Tomography

Here, we develop and experimentally demonstrate a methodology for a full molecular frame quantum tomography (MFQT) of dynamical polyatomic systems. We exemplify this approach through the complete characterization of an electronically nonadiabatic wave packet in ammonia (NH 3 ). The method exploits both energy and time-domain spectroscopic data, and yields the lab frame density matrix (LFDM) for the system, the elements of which are populations and coherences. The LFDM fully characterizes electronic and nuclear dynamics in the molecular frame, yielding the time- and orientation-angle dependent expectation values of any relevant operator. For example, the time-dependent molecular frame electronic probability density may be constructed, yielding information on electronic dynamics in the molecular frame. In NH 3 , we observe that electronic coherences are induced by nuclear dynamics which nonadiabatically drive electronic motions (charge migration) in the molecular frame. Here, the nuclear dynamics are rotational and it is nonadiabatic Coriolis coupling which drives the coherences. Interestingly, the nuclear-driven electronic coherence is preserved over longer timescales. In general, MFQT can help quantify entanglement between electronic and nuclear degrees of freedom, and provide new routes to the study of ultrafast molecular dynamics, charge migration, quantum information processing, and optimal control schemes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural and functional analyses of human cerebral cortex using a surface-based atlas

We have analyzed the geometry, geography, and functional organization of human cerebral cortex using surface reconstructions and cortical flat maps of the left and right hemispheres generated from a digital atlas (the Visible Man). The total surface area of the reconstructed Visible Man neocortex is 1570 cm2 (both hemispheres), approximately 70% of which is buried in sulci. By linking the Visible Man cerebrum to the Talairach stereotaxic coordinate space, the locations of activation foci reported in neuroimaging studies can be readily visualized in relation to the cortical surface. The associated spatial uncertainty was empirically shown to have a radius in three dimensions of approximately 10 mm. Application of this approach to studies of visual cortex reveals the overall patterns of activation associated with different aspects of visual function and the relationship of these patterns to topographically organized visual areas. Our analysis supports a distinction between an anterior region in ventral occipito-temporal cortex that is selectively involved in form processing and a more posterior region (in or near areas VP and V4v) involved in both form and color processing. Foci associated with motion processing are mainly concentrated in a region along the occipito-temporal junction, the ventral portion of which overlaps with foci also implicated in form processing. Comparisons between flat maps of human and macaque monkey cerebral cortex indicate significant differences as well as many similarities in the relative sizes and positions of cortical regions known or suspected to be homologous in the two species.

NASA Discipline Neuroscience↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, November 2012

The topics include: Visual System for Browsing, Analysis, and Retrieval of Data (ViSBARD); Time-Domain Terahertz Computed Axial Tomography NDE System; Adaptive Sampling of Time Series During Remote Exploration; A Tracking Sun Photometer Without Moving Parts; Surface Temperature Data Analysis; Modular, Autonomous Command and Data Handling Software with Built-In Simulation and Test; In-Situ Wire Damage Detection System; Amplifier Module for 260-GHz Band Using Quartz Waveguide Transitions; Wideband Agile Digital Microwave Radiometer; Buckyball Nucleation of HiPco Tubes; FACT, Mega-ROSA, SOLAROSA; An Integrated, Layered-Spinel Composite Cathode for Energy Storage Applications; Engineered Multifunctional Surfaces for Fluid Handling; Polyolefin-Based Aerogels; Adjusting Permittivity by Blending Varying Ratios of SWNTs; Gravity-Assist Mechanical Simulator for Outreach; Concept for Hydrogen-Impregnated Nanofiber/Photovoltaic Cargo Stowage System; DROP: Durable Reconnaissance and Observation Platform; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; Spectroscopic Chemical Analysis Methods and Apparatus; Low Average Sidelobe Slot Array Antennas for Radiometer Applications; Motion-Corrected 3D Sonic Anemometer for Tethersondes and Other Moving Platforms; Water Treatment Systems for Long Spaceflights; Microchip Non-Aqueous Capillary Electrophoresis (MicronNACE) Method to Analyze Long-Chain Primary Amines; Low-Cost Phased Array Antenna for Sounding Rockets, Missiles, and Expendable Launch Vehicles; Mars Science Laboratory Engineering Cameras; Seismic Imager Space Telescope; Estimating Sea Surface Salinity and Wind Using Combined Passive and Active L-Band Microwave Observations; A Posteriori Study of a DNS Database Describing Super critical Binary-Species Mixing; Scalable SCPPM Decoder; QuakeSim 2.0; HURON (HUman and Robotic Optimization Network) Multi-Agent Temporal Activity Planner/Scheduler; MPST Software: MoonKommand

Source record↗

AK112: Full Waveform Inversion Tomography of Alaska Improves Waveform Fits While Imaging Crustal, Mantle, and Slab Structure

We report a full waveform inversion tomography model of Alaska and the surrounding regions, inferring radially anisotropic shear and isotropic compressional wavespeeds by fitting complete waveforms from 120 regional earthquakes. Our multiscale approach inverted time–frequency phase misfits (maximum period of 100 s), starting with a minimum period of 40 s and ending at 20 s in 7 stages and 112 total iterations. The model (AK112) was evaluated by computing the misfits for 36 independent validation events. We find that misfit reductions were large and equal (∼55%) for both the inversion and validation data sets, providing confidence in the model. AK112 also provides much better waveform fits compared to other reported models for the region, including an isotropic version of itself, highlighting the importance of anisotropy. The model resolves known crustal, upper mantle, and slab structure to depths of 100 km with new detail: sedimentary basins in the Alaskan Shelf, Cook Inlet, and Colville basins, among others; discontinuous lithospheric structure across major terrane boundaries; and subducting slab geometry and back‐arc volcanic sources. In addition to tectonic interpretations, the model enables full waveform simulations for long‐period earthquake ground motions and source characterization (e.g., moment tensor and finite‐fault inversion).

Rodgers, Arthur [Lawrence Livermore National Labor↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Overview of the Digitization Workflow Post Image Acquisition of Apollo Lunar and Antarctic Meteorite Samples Using Agisoft Photoscan for the NASA 3D Astromaterials Virtual Samples Collection

The 3D Virtual Astromaterials Samples (3DVAS) collection is a multi-year funded project to create a digital database of sixty Apollo Lunar and Antarctic Meteorite samples following non-destructive documentation conservation protocols. After initial image processing, the photos are evaluated and processed using unique structure-from-motion photogrammetric techniques in a high performance modelling software designed to create a 3D model from 2D images: Agisoft Photoscan Pro. Agisoft Photoscan Pro uses image processing algorithms and techniques originating in computer vision to resolve 3D models for accurate and detailed visualization of a subject. The software provides a stepwise process that is tailored per model based on spatial and specular reflectance properties, for example. The process includes: photo alignment, creation of a dense point cloud, mesh, and finally texture. Photo alignment is dependent on model properties. The 3DVAS process requires a special rotation platform with calibrated photogrammetric targets, specific distance rotation protocols, and a contrasting background for alignment and scale accuracy. As a result of the photographic process, alignment will complete with two mirrored hemispheres that, in a sense, represent the 2D images overlapping to create a 3D model. Each dense point cloud is analyzed with provided statistical measures in a gradual selection process to eliminate outliers. The point cloud is reduced to include only data valuable to the final model. When a precise dense point cloud is achieved, a mesh and texture are applied. Each model is scaled with scale bar accuracies within 100 microns. Each sample has its own intimate process for modelling; there is no standard for the parameters required in the final creation of a high resolution model. By processing multiple samples, a skill is gained in practice to allow a close definition of the original sample and will result in the most detailed version of the sample shell. This process completes one-fifth of the 3DVAS protocol for providing accurate digital documentation. Each model shell is merged with X-ray Computed Tomography data to create a full volumetric sample. All 3DVAS data will be served on NASA's Astromaterials Acquisition and Curation website with an early subset of data available in 2019 and the 3D Virtual Astromaterials Samples Collection launch in 2020.

Thomas, Andi B.↗

Validation of seismic velocity models in southern California with full-waveform simulations

SUMMARY Crustal seismic velocity models provide essential information for many applications including earthquake source properties, simulations of ground motion and related derivative products. We present a systematic workflow for assessing the accuracy of velocity models with full-waveform simulations. The framework is applied to four regional seismic velocity models for southern California: CVM-H15.11, CVM-S4.26, CVM-S4.26.M01 that includes a shallow geotechnical layer, and the model of Berg et al. For each model, we perform 3-D viscoelastic wave propagation simulations for 48 virtual seismic noise sources (down to 2 s) and 44 moderate-magnitude earthquakes (down to 2 s generally and 0.5 s for some cases) assuming a minimum shear wave velocity of 200 m s–1. The synthetic waveforms are compared with observations associated with both earthquake records and noise cross-correlation data sets. We measure, at multiple period bands for well-isolated seismic phases, traveltime delays and normalized zero-lag cross-correlation coefficients between the synthetic and observed data. The obtained measurements are summarized using the mean absolute derivation of time delay and the mean correlation coefficient. These two metrics provide reliable statistical representations of model quality with consistent results in all data sets. In addition to assessing the overall (average) performance of different models in the entire study area, we examine spatial variations of the models’ quality. All examined models show good phase and waveform agreements for surface waves at periods longer than 5 s, and discrepancies at shorter periods reflecting small-scale heterogeneities and near-surface structures. The model performing best overall is CVM-S4.26.M01. The largest misfits for both body and surface waves are in basin structures and around large fault zones. Inaccuracies generated in these areas may affect tomography and model simulation results at other regions. The seismic velocity models for southern California can be improved by adding better resolved structural representations of the shallow crust and volumes around the main faults.

58 GEOSCIENCES↗