Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Model-based Iterative Reconstruction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

3D reconstruction of the magnetic vector potential using model based iterative reconstruction

Lorentz transmission electron microscopy (TEM) observations of magnetic nanoparticles contain information on the magnetic and electrostatic potentials. Vector field electron tomography (VFET) can be used to reconstruct electromagnetic potentials of the nanoparticles from their corresponding LTEM images. The VFET approach is based on the conventional filtered back projection approach to tomographic reconstructions and the availability of an incomplete set of measurements due to experimental limitations means that the reconstructed vector fields exhibit significant artifacts. In this paper, we outline a model-based iterative reconstruction (MBIR) algorithm to reconstruct the magnetic vector potential of magnetic nanoparticles. We combine a forward model for image formation in TEM experiments with a prior model to formulate the tomographic problem as a maximum a-posteriori probability estimation problem (MAP). The MAP cost function is minimized iteratively to determine the vector potential. Here, a comparative reconstruction study of simulated as well as experimental data sets show that the MBIR approach yields quantifiably better reconstructions than the VFET approach.

36 MATERIALS SCIENCE↗

TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range of acquisition and reconstruction parameters present in the clinical environment. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗

Wavelength-resolved Neutron Tomography for Crystalline Materials

Wavelength-resolved (WR) neutron transmission tomography is an emerging technique to characterize engineering materials. While tomographic reconstruction for amorphous samples is straightforward, it is challenging to reconstruct samples with single-crystal domains because the attenuation of the sample varies as a function of its orientation with respect to the incident beam due to Bragg scattering. In this paper, we present an algorithm that can reconstruct samples with single-crystal domains from WR neutron tomographic measurements. In particular, we use a model-based iterative reconstruction (MBIR) technique that reconstructs the volume by identifying and leaving out the regions of the measurement that are affected by Bragg scatter. We combine the output of the MBIR method with an algorithm that matches the reconstruction to the identified Bragg scatter to reconstruct a feature that corresponds to the local crystallography of the sample being measured. Using simulated data, we demonstrate how our algorithm can reconstruct materials with single-crystal domains, thereby adding a powerful new capability for WR neutron imaging instruments.

Singanallur Vaidyanathan, Venkatakrishnan↗

Evaluation of Advanced Signal Processing Techniques to Improve Detection and Identification of Embedded Defects

By the end of 1996, 109 Nuclear Power Plants were operating in the United States, producing 22% of the Nation’s electricity [1]. At present, more than two thirds of these power plants are more than 40 years old. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years [2]. The most important safety structures in an NPP are constructed of concrete. The structures generally do not allow for destructive evaluation and access is limited to one side of the concrete element. Therefore, there is a need for techniques and technologies that can assess the internal health of complex, reinforced concrete structures nondestructively. Previously, we documented the challenges associated with Non-Destructive Evaluation (NDE) of thick, reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures [3]. Consequently, a 7 feet tall, by 7 feet wide, by 3 feet and 4-inch-thick concrete specimen was constructed with 2.257-inch-and 1-inch-diameter rebar every 6 to 12 inches. In addition, defects were embedded the specimen to assess the performance of existing and future NDE techniques. The defects were designed to give a mix of realistic and controlled defects for assessment of the necessary measures needed to overcome the challenges with more heavily reinforced concrete structures. Information on the embedded defects is documented in [4]. We also documented the superiority of Frequency Banded Decomposition (FBD) Synthetic Aperture Focusing Technique (SAFT) over conventional SAFT when probing defects under deep concrete cover. Improvements include seeing an intensity corresponding to a defect that is either not visible at all in regular, full frequency content SAFT, or an improvement in contrast over conventional SAFT reconstructed images. This report documents our efforts in four fronts: 1) Comparative study between traditional SAFT and FBD SAFT for concrete specimen with and without Alkali-Silica Reaction (ASR) damage, 2) improvement of our Model-Based Iterative Reconstruction (MBIR) for thick reinforced concrete [5], 3) development of a universal framework for sharing, reconstruction, and visualization of ultrasound NDE datasets, and 4) application of machine learning techniques for automated detection of ASR inside concrete. Our comparative study between FBD and traditional SAFT reconstruction images shows a clear difference between images of ASR and non-ASR specimens. In particular, the left first harmonic shows an increased contrast and sensitivity to ASR damage. For MBIR, we show the superiority of model-based techniques over delay and sum techniques such as SAFT. Improvements include elimination of artifacts caused by direct arrival signals, and increased contrast and Signal to Noise Ratio. For the universal framework, we document a format for data storage based on the HDF5 file format, and also propose a modular Graphic User Interface (GUI) for easy customization of data conversion, reconstruction, and visualization routines. Finally, two techniques for ASR automated detection are presented. The first technique is based on an analysis of the frequency content using Hilbert Transform Indicator (HTI) and the second technique employees Artificial Neural Network (ANN) techniques for training and classification of ultrasound data as ASR or non-ASR damaged classes. The ANN technique shows great potential with classification accuracy above 95%. These approaches are extensible to the detection of additional reinforced, thick concrete defects and damage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model-Based Reconstruction for Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a novel technology for imaging inside multi-layered structures such as geothermal wells. Such systems include a transmitter and multiple receivers to capture reflected signals. Common algorithms for ultrasound reconstruction use delay-and-sum (DAS) approaches; these have low computational complexity but produce inaccurate images in the presence of complex structures and specialized geometries such as collimated beams.In this paper, we propose a multi-layer, ultrasonic, model-based iterative reconstruction algorithm designed for collimated beam systems. We introduce a physics-based forward model to accurately ac-count for the propagation of a collimated ultrasonic beam in multi-layer media and describe an efficient implementation using binary search. We model direct arrival signals, detector noise, and a spatially varying image prior, then cast the reconstruction as a maximum a posteriori estimation problem. Using simulated and experimental data we obtain significantly fewer artifacts relative to DAS while running in near real time using commodity compute resources.

Alanazi, Abdulrahman M.↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

DEEP NEURAL NETWORKS FOR NON-LINEAR MODEL-BASED ULTRASOUND RECONSTRUCTION

Ultrasound reflection tomography is widely used to image large complex specimens that are only accessible from a single side, such as well systems and nuclear power plant containment walls. Typical methods for inverting the measurement rely on delay-and-sum algorithms that rapidly produce reconstructions but with significant artifacts. Recently, model-based reconstruction approaches using a linear forward model have been shown to significantly improve image quality compared to the conventional approach. Nonetheless, even these techniques result in artifacts for complex objects because of the inherent non-linearity of the ultrasound forward model.In this paper, we propose a non-iterative model-based reconstruction method for inverting measurements that are based on non-linear forward models for ultrasound imaging. Our approach involves obtaining an approximate estimate of the reconstruction using a simple linear back-projection and training a deep neural network to refine this to the actual reconstruction. As a result, we apply our method to simulated and experimental ultrasound data to demonstrate dramatic improvements in image quality compared to the delay-and-sum approach and the linear model-based reconstruction approach.

97 MATHEMATICS AND COMPUTING↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Real-time sparse-sampled Ptychographic imaging through deep neural networks

Ptychography has rapidly grown in the fields of X-ray and electron imaging for its unprecedented ability to achieve nano or atomic scale resolution while simultaneously retrieving chemical or magnetic information from a sample. A ptychographic reconstruction is achieved by means of solving a complex inverse problem that imposes constraints both on the acquisition and on the analysis of the data, which typically precludes real-time imaging due to computational cost involved in solving this inverse problem. In this work we propose PtychoNN, a novel approach to solve the ptychography reconstruction problem based on deep convolutional neural networks. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. The presented results demonstrate how PtychoNN can effectively be used on experimental data, being able to generate high quality reconstructions of a sample up to hundreds of times faster than state-of-the-art ptychography reconstruction solutions once trained. By surpassing the typical constraints of iterative model-based methods, we can significantly relax the data acquisition sampling conditions and produce equally satisfactory reconstructions. Besides drastically accelerating acquisition and analysis, this capability can enable new imaging scenarios that were not possible before, in cases of dose sensitive, dynamic and extremely voluminous samples.

Cherukara, Mathew J↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it is implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.

60 APPLIED LIFE SCIENCES↗

A Plug-and-Play Priors Approach for Solving Nonlinear Imaging Inverse Problems

In the past two decades, nonlinear image reconstruction methods have led to substantial improvements in the capabilities of numerous imaging systems. Such methods are traditionally formulated as optimization problems that are solved iteratively by simultaneously enforcing data consistency and incorporating prior models. Recently, the Plug-and-Play Priors (PPP) framework suggested that by using more sophisticated denoisers, not necessarily corresponding to an optimization objective, it is possible to improve the quality of reconstructed images. Here in this letter, we show that the PPP approach is applicable beyond linear inverse problems. In particular, we develop the fast iterative shrinkage/thresholding algorithm variant of PPP for model-based nonlinear inverse scattering. The key advantage of the proposed formulation over the original ADMM-based one is that it does not need to perform an inversion on the forward model. We show that the proposed method produces high quality images using both simulated and experimentally measured data.

97 MATHEMATICS AND COMPUTING↗

Accelerating error correction in tomographic reconstruction

Abstract Spurred by recent advances in detector technology and X-ray optics, upgrades to scanning-probe-based tomographic imaging have led to an exponential growth in the amount and complexity of experimental data and have created a clear opportunity for tomographic imaging to approach single-atom sensitivity. The improved spatial resolution, however, is highly susceptible to systematic and random experimental errors, such as center of rotation drifts, which may lead to imaging artifacts and prevent reliable data extraction. Here, we present a model-based approach that simultaneously optimizes the reconstructed specimen and sinogram alignment as a single optimization problem for tomographic reconstruction with center of rotation error correction. Our algorithm utilizes an adaptive regularizer that is dynamically adjusted at each alternating iteration step. Furthermore, we describe its implementation in a software package targeting high-throughput workflows for execution on distributed-memory clusters. We demonstrate the performance of our solver on large-scale synthetic problems and show that it is robust to a wide range of noise and experimental drifts with near-ideal throughput.

Ali, Sajid (ORCID:0000000321864636)↗

Hydrodynamic and Radiographic Toolbox (HART)

With a multi-lab and university team, we propose to develop new methods for a Hydrodynamic and Radiographic Toolbox (HART) that will enable a fuller and more extensive use of experimental radiographic data towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in areas of computational imaging, statistical and machine learning, and reduced order modeling of hydrodynamics. In terms of software practices, by partnering with XCP (RISTRA Project) we will conform to recent XCP standards that are inline with modern software practices and standards and ensure compatibility and ease of inter-operability with existing codes. Three new activities under this proposal include (a) the development and use of deep learning-based surrogates to accelerate reconstruction and variational inference of density fields from radiographs of hydrotests, (b) a model-data fusion strategy that couples deep learning-based density reconstructions with fast hydrodynamics simulators to better constrain the reconstruction, and (c) a method for treating asymmetries using techniques adopted from limited view tomography. All three new activities will be based on improved treatment of scatter, noise, beam spot movement, detector blur, and flat fielding in the forward model, and a use of sophisticated priors to aid in the re construction. The improvements to the forward model and improved algorithmic design of the reconstruction when complete will be contained in the iterative reconstruction code SHIVA—a code project that we have recently initiated. The many ways in which machine learning can be used in the reconstruction work will be contained in a code HERMES that has been initiated with DTRA support. For example, the significant levels of acceleration that will likely be achieved by the use of machine learning techniques will permit us (and are required) to quantify uncertainties in density retrievals. Next, the two-way coupling between density reconstruction and model-based simulation of the hydrodynamics will be contained in code EREBUS, and will permit a fuller realization of the potential of the data to constrain the hydrodynamic model and better address issues related to asymmetries in the problem. Finally, we anticipate that the better consistency with physics achieved in our reconstructions will allow them to be used by X-Division more so than today.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗