Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Model calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dealing with Measurement Uncertainties as Nuisance Parameters in Bayesian Model Calibration

In the presence of model discrepancy, the calibration of physics-based models for physical parameter inference is a challenging problem. Lack of identifiability between calibration parameters and model discrepancy requires additional identifiability constraints to be placed on the model discrepancy to obtain unique physical parameter estimates. If these assumptions are violated, the inference for the calibration parameters can be systematically biased. In many applications, such as in dynamic material property experiments, many of the calibration inputs refer to measurement uncertainties. Here, we develop a metric for identifying overfitting of these measurement uncertainties, propose a prior capable of reducing this overfitting, and show how this leads to a diagnostic tool for validation of physical parameter inference. The approach is demonstrated for a benchmark example and applied for a material property application to perform inference on the equation of state parameters of tantalum.

97 MATHEMATICS AND COMPUTING↗

An asynchronous parallel high-throughput model calibration framework for crystal plasticity finite element constitutive models

Crystal plasticity finite element model (CPFEM) is a powerful numerical simulation in the integrated computational materials engineering toolboxes that relates microstructures to homogenized materials properties and establishes the structure–property linkages in computational materials science. However, to establish the predictive capability, one needs to calibrate the underlying constitutive model, verify the solution and validate the model prediction against experimental data. Bayesian optimization (BO) has stood out as a gradient-free efficient global optimization algorithm that is capable of calibrating constitutive models for CPFEM. Here in this paper, we apply a recently developed asynchronous parallel constrained BO algorithm to calibrate phenomenological constitutive models for stainless steel 304 L, Tantalum, and Cantor high-entropy alloy.

304L stainless steel↗

Elastic Bayesian Model Calibration

Functional data are ubiquitous in scientific modeling. For instance, quantities of interest are modeled as functions of time, space, energy, density, etc. Uncertainty quantification methods for computer models with functional response have resulted in tools for emulation, sensitivity analysis, and calibration that are widely used. However, many of these tools do not perform well when the computer model’s parameters control both the amplitude variation of the functional output and its alignment (or phase variation). This paper introduces a framework for Bayesian model calibration when the model responses are misaligned functional data. The approach generates two types of data out of the misaligned functional responses: (1) aligned functions so that the amplitude variation is isolated and (2) warping functions that isolate the phase variation. These two types of data are created for the computer simulation data (both of which may be emulated) and the experimental data. The calibration approach uses both types so that it seeks to match both the amplitude and phase of the experimental data. The framework is careful to respect constraints that arise, especially when modeling phase variation, and is framed in a way that it can be done with readily available calibration software. In conclusion, we demonstrate the techniques on two simulated data examples and on two dynamic material science problems: a strength model calibration using flyer plate experiments and an equation of state model calibration using experiments performed on the Sandia National Laboratories’ Z-machine.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for distributed power system model calibration

A computing device for distributed power system model calibration is provided. The computing device is programmed to receive event data and model response data associated with a model to simulate, wherein the model includes a plurality of parameters, divide the event data into a plurality of sets, wherein each set includes associated parameters, and transmit the plurality of sets of event data to a plurality of client nodes. Each client node of the plurality of client nodes is programmed to analyze a corresponding set of event data to determine updated parameters for the model. The computing device is further programmed to receive a plurality of updated parameters for the model from the plurality of client nodes and analyze the received plurality of updated parameters to determine at least one adjusted parameter.

Wang, Honggang↗

Computer Model Calibration with Time Series Data Using Deep Learning and Quantile Regression

Computer models play a key role in many scientific and engineering problems. One major source of uncertainty in computer model experiments is input parameter uncertainty. Computer model calibration is a formal statistical procedure to infer input parameters by combining information from model runs and observational data. The existing standard calibration framework suffers from inferential issues when the model output and observational data are high-dimensional dependent data, such as large time series, due to the difficulty in building an emulator and the nonidentifiability between effects from input parameters and data-model discrepancy. To overcome these challenges, we, in this work, propose a new calibration framework based on a deep neural network (DNN) with long short-term memory layers that directly emulates the inverse relationship between the model output and input parameters. Adopting the “learning with noise” idea, we train our DNN model to filter out the effects from data-model discrepancy on input parameter inference. We also formulate a new way to construct interval predictions for DNN using quantile regression to quantify the uncertainty in input parameter estimates. Through a simulation study and real data application with the Weather Research and Forecasting Model Hydrological modeling system (WRF-Hydro), we show our approach can yield accurate point estimates and well-calibrated interval estimates for input parameters.

97 MATHEMATICS AND COMPUTING↗

Model Calibration for Cancer Risk Projections According to Uncertain Data

This paper presents forward and inverse formulations for the calibration of computational models according to uncertain data. Uncertainty in the data might be caused by a poor metrology system, measurement noise, missing or uncontrollable input variables, or by the inability to directly measure the inputs and/or outputs of interest. The forward approach performs the calibration in the space of the model’s output thereby requiring repeated model simulations. Conversely, the inverse approach leverages an ensemble of solutions to an inverse problem in order to perform the calibration in the space of the model’s parameters. As such, the computational demands of the inverse approach are considerably lower. These strategies are applied to the calibration of a radiation model that in-forms cancer risk projections for future deep space missions.

uncertainty quantification↗

Leveraging Pre-storm Soil Moisture Estimates for Enhanced Land Surface Model Calibration in Ungauged Hydrologic Basins

Despite long-standing efforts, hydrologists still lack robust tools for calibrating land surface model (LSM) streamflow estimates within ungauged basins. Using surface soil moisture estimates from the Soil Moisture Active Passive Level 4 Soil Moisture (L4_SM) product, precipitation observations, and streamflow gauge measurements for 617 medium-scale (200-10,000 km2) basins in the contiguous United States, we measure the temporal (Spearman) rank correlation between antecedent (i.e., pre-storm) surface soil moisture (ASM) and the storm-scale runoff coefficient (RC; the fraction of storm-scale precipitation accumulation converted into streamflow). In humid and semi-humid basins, this rank correlation is shown to be sufficiently strong to allow for the substitution of storm-scale RC observations (available only in basins that are both lightly regulated and gauged) with high-quality ASM values (available quasi-globally from L4_SM) in streamflow calibration procedures. Using this principle, we define a new, basin-wise LSM streamflow calibration approach based on L4_SM alone and successfully apply it to identify LSM configurations that produce a high rank correlation with observed RC. However, since the approach cannot detect RC bias, it is less successful in identifying LSM configurations with low mean-absolute error. Plain Text Summary Accurately forecasting the fraction of rainfall that runs off into streams, as opposed to infiltrates into the soil, is critical for flash-flood prediction, water-resource monitoring, and tracking the transport of nutrients from agricultural fields into local waterways. Such forecasting is typically performed by hydrologic models that attempt to represent the physical processes responsible for surface runoff generation. However, to provide accurate streamflow forecasts, these models typically need to be calibrated against actual streamflow observations. This is problematic given the relatively poor, and declining, global availability of stream gauges. This paper presents a novel model calibration strategy that uses soil moisture from remote sensing and numerical modeling in place of streamflow observations during calibration. This transition has significant practical advantages because, unlike streamflow observations, the soil moisture data are continuously available across space. Our results demonstrate that this new approach can significantly improve hydrologic models within humid and semi-humid basins lacking sufficient ground-based instrumentation for traditional streamflow calibration.

hydrologic models↗

Rate and temperature independent model calibrations for J2 plasticity and Wilkins failure models for 17-4PH H1150 stainless steel

This memo’s objective is to report a calibration of the J2 plasticity model with the Wilkins ductile failure criterion for 17-4 PH H1150 stainless steel under slow loading at room temperature. The calibration of the hardening function was based on uniaxial tension tests, while that of the failure model included data from tension tests on notched specimens, a butterfly specimen shear test, and a set of interrupted compression tests on shear hat specimens. The procedure was that described in, minus the rate and temperature dependence.

36 MATERIALS SCIENCE↗

Comprehensive Material Characterization and Simultaneous Model Calibration for Improved Computational Simulation Credibility

Computational simulation is increasingly relied upon for high-consequence engineering decisions, and a foundational element to solid mechanics simulations is a credible material model. Our ultimate vision is to interlace material characterization and model calibration in a real-time feedback loop, where the current model calibration results will drive the experiment to load regimes that add the most useful information to reduce parameter uncertainty. The current work investigated one key step to this Interlaced Characterization and Calibration (ICC) paradigm, using a finite load-path tree to incorporate history/path dependency of nonlinear material models into a network of surrogate models that replace computationally-expensive finite-element analyses. Our reference simulation was an elastoplastic material point subject to biaxial deformation with a Hill anisotropic yield criterion. Training data was generated using either a space-filling or adaptive sampling method, and surrogates were built using either Gaussian process or polynomial chaos expansion methods. Surrogate error was evaluated to be on the order of 10 ⁻5 and 10 ⁻3 percent for the space-filling and adaptive sampling training data, respectively. Direct Bayesian inference was performed with the surrogate network and with the reference material point simulator, and results agreed to within 3 significant figures for the mean parameter values, with a reduction in computational cost over 5 orders of magnitude. These results bought down risk regarding the surrogate network and facilitated a successful FY22-24 full LDRD proposal to research and develop the complete ICC paradigm.

36 MATERIALS SCIENCE↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Reactive burn model calibration using high-throughput initiation experiments at sub-millimeter length scales

We report a first-of-its-kind model calibration was performed using Sandia National Laboratories’ high-throughput initiation (HTI) experiment for two types of vapor-deposited explosive films consisting of hexanitrostilbene (HNS) or pentaerythritol tetranitrate (PETN). These films exhibit prompt initiation, and they reach steady detonation at sub-millimeter length scales. Following prior work on HNS, we test the hypothesis of approximating these explosive films as fine-grained homogeneous solids with simple Arrhenius kinetics burn models. The model calibration process is described herein using a single-step as well as a two-step Arrhenius rate law, and it consists of systematic parameter sampling leading to a reduction in the model degrees of freedom. Multiple local minima are observed; results are given for seven different optimized parameter sets. Each model set is further evaluated in a two-dimensional simulation of the critical failure thickness for a sustained detonation. Overall, the two-step Arrhenius kinetics model captures the observed behavior for HNS; however, neither model produces a good fit to the PETN data. We hypothesize that the HTI results for PETN correspond to a heterogeneous response, owing to the smaller reaction zone of PETN compared to HNS (i.e., it does not homogenize the fine-grained hot spots as well). Future work should consider using the ignition and growth model for PETN, as well as other reactive burn models such as xHVRB, AWSD, PiSURF, and CREST.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bayesian optimal experimental design for constitutive model calibration

Computational simulation is increasingly relied upon for high/consequence engineering decisions, which necessitates a high confidence in the calibration of and predictions from complex material models. However, the calibration and validation of material models is often a discrete, multi-stage process that is decoupled from material characterization activities, which means the data collected does not always align with the data that is needed. To address this issue, an integrated workflow for delivering an enhanced characterization and calibration procedure—Interlaced Characterization and Calibration (ICC)—is introduced and demonstrated. Further, this framework leverages Bayesian optimal experimental design (BOED), which creates a line of communication between model calibration needs and data collection capabilities in order to optimize the information content gathered from the experiments for model calibration. Eventually, the ICC framework will be used in quasi real-time to actively control experiments of complex specimens for the calibration of a high-fidelity material model. This work presents the critical first piece of algorithm development and a demonstration in determining the optimal load path of a cruciform specimen with simulated data. Calibration results, obtained via Bayesian inference, from the integrated ICC approach are compared to calibrations performed by choosing the load path a priori based on human intuition, as is traditionally done. The calibration results are communicated through parameter uncertainties which are propagated to the model output space (i.e. stress–strain). In these exemplar problems, data generated within the ICC framework resulted in calibrated model parameters with reduced measures of uncertainty compared to the traditional approaches.

42 ENGINEERING↗

Finite Element Model Calibration Approach for Ares I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of nonconventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pre-test predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Finite Element Model Calibration Approach for Area I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of non-conventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pretest predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Knowledge-informed deep learning for hydrological model calibration: an application to Coal Creek Watershed in Colorado

Abstract. Deep learning (DL)-assisted inverse mapping has shown promise in hydrological model calibration by directly estimating parameters from observations. However, the increasing computational demand for running the state-of-the-art hydrological model limits sufficient ensemble runs for its calibration. In this work, we present a novel knowledge-informed deep learning method that can efficiently conduct the calibration using a few hundred realizations. The method involves two steps. First, we determine decisive model parameters from a complete parameter set based on the mutual information (MI) between model responses and each parameter computed by a limited number of realizations (∼50). Second, we perform more ensemble runs (e.g., several hundred) to generate the training sets for the inverse mapping, which selects informative model responses for estimating each parameter using MI-based parameter sensitivity. We applied this new DL-based method to calibrate a process-based integrated hydrological model, the Advanced Terrestrial Simulator (ATS), at Coal Creek Watershed, CO. The calibration is performed against observed stream discharge (Q) and remotely sensed evapotranspiration (ET) from the water year 2017 to 2019. Preliminary MI analysis on 50 realizations resulted in a down-selection of 7 out of 14 ATS model parameters. Then, we performed a complete MI analysis on 396 realizations and constructed the inverse mapping from informative responses to each of the selected parameters using a deep neural network. Compared with calibration using observations covering all time steps, the new inverse mapping improves parameter estimations, thus enhancing the performance of ATS forward model runs. The Nash–Sutcliffe efficiency (NSE) of streamflow predictions increases from 0.53 to 0.8 when calibrating against Q alone. Using ET observations, on the other hand, does not show much improvement on the performance of ATS modeling mainly due to both the uncertainty of the remotely sensed product and the insufficient coverage of the model ET ensemble in capturing the observation. By using observed Q only, we further performed a multiyear analysis and show that Q is best simulated (NSE > 0.8) by including in the calibration the dry-year flow dynamics that show more sensitivity to subsurface characteristics than the other wet years. Moreover, when continuing the forward runs till the end of 2021, the calibrated models show similar simulation performances during this evaluation period as the calibration period, demonstrating the ability of the estimated parameters in capturing climate sensitivity. Our success highlights the importance of leveraging data-driven knowledge in DL-assisted hydrological model calibration.

54 ENVIRONMENTAL SCIENCES↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibrating Historical IR Sensors Using GEO, and AVHRR Infrared Tropical Mean Calibration Models

Long-term, remote-sensing-based climate data records (CDRs) are highly dependent on having consistent, wellcalibrated satellite instrument measurements of the Earth's radiant energy. Therefore, by making historical satellite calibrations consistent with those of today's imagers, the Earth-observing community can benefit from a CDR that spans a minimum of 30 years. Most operational meteorological satellites rely on an onboard blackbody and space looks to provide on-orbit IR calibration, but neither target is traceable to absolute standards. The IR channels can also be affected by ice on the detector window, angle dependency of the scan mirror emissivity, stray-light, and detector-to-detector striping. Being able to quantify and correct such degradations would mean IR data from any satellite imager could contribute to a CDR. Recent efforts have focused on utilizing well-calibrated modern hyper-spectral sensors to intercalibrate concurrent operational IR imagers to a single reference. In order to consistently calibrate both historical and current IR imagers to the same reference, however, another strategy is needed. Large, well-characterized tropical-domain Earth targets have the potential of providing an Earth-view reference accuracy of within 0.5 K. To that effort, NASA Langley is developing an IR tropical mean calibration model in order to calibrate historical Advanced Very High Resolution Radiometer (AVHRR) instruments. Using Meteosat-9 (Met-9) as a reference, empirical models are built based on spatially/temporally binned Met-9 and AVHRR tropical IR brightness temperatures. By demonstrating the stability of the Met-9 tropical models, NOAA-18 AVHRR can be calibrated to Met-9 by matching the AVHRR monthly histogram averages with the Met-9 model. This method is validated with ray-matched AVHRR and Met-9 biasdifference time series. Establishing the validity of this empirical model will allow for the calibration of historical AVHRR sensors to within 0.5 K, and thereby establish a climate-quality IR data record.

Scarino, Benjamin↗