Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modbus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

FL‐ADS: Federated learning anomaly detection system for distributed energy resource networks

Abstract With the ongoing development of Distributed Energy Resources (DER) communication networks, the imperative for strong cybersecurity and data privacy safeguards is increasingly evident. DER networks, which rely on protocols such as Distributed Network Protocol 3 and Modbus, are susceptible to cyberattacks such as data integrity breaches and denial of service due to their inherent security vulnerabilities. This paper introduces an innovative Federated Learning (FL)‐based anomaly detection system designed to enhance the security of DER networks while preserving data privacy. Our models leverage Vertical and Horizontal Federated Learning to enable collaborative learning while preserving data privacy, exchanging only non‐sensitive information, such as model parameters, and maintaining the privacy of DER clients' raw data. The effectiveness of the models is demonstrated through its evaluation on datasets representative of real‐world DER scenarios, showcasing significant improvements in accuracy and F1‐score across all clients compared to the traditional baseline model. Additionally, this work demonstrates a consistent reduction in loss function over multiple FL rounds, further validating its efficacy and offering a robust solution that balances effective anomaly detection with stringent data privacy needs.

Purohit, Shaurya [Iowa State University Ames Iowa ↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

A Communication Testbed for Testing Power Electronic Agent Systems

Power electronic systems (PES) incorporate complex intra-system communication, which are of vital importance for the successful operation of these systems. This paper proposes and outlines a communication testbed that will help in the development and testing of the communications between the components of PES. It allows for the comparison and evaluation of different communication methods, such as MQTT, Modbus, or User Datagram Protocol (UDP), and for the characterization of how these communication protocols perform.

Dean, Ben↗

VAC: A Software Approach to Resilient SCADA Automation

To better secure critical infrastructure, especially power systems, this paper introduces a virtual SCADA automation controller. The automation controller is a gateway into a power subsystem, making it a valuable target for cyber-attacks that could cut it off from the control center and cause a loss of view and control. To prevent this, the Virtual Automation Controller (VAC) is a backup device that mirrors the capabilities of the physical controller. It can communicate via Modbus and DNP3 and is containerized so it can be deployed on a variety of platforms. Furthermore, it utilizes software-defined networking to quickly disconnect a failed automation controller and preserve its state for forensics. The VAC gives system operators time to replace the failed controller and prevents dangerous and costly damage to power systems. The VAC is compared against the SEL 3505-3 RTAC and shown to have the necessary features to act as a failover controller.

Johnson, Jordan↗

An Asynchronous Real-time Co-simulation Platform for Modeling Interaction between Microgrids and Power Distribution Systems

This paper presents the modeling framework of an asynchronous, real-time co-simulation platform for modeling the interactions between microgrids and power distribution systems. Components of each microgrid are simulated on the OPAL-RT eMEGASIM platform so that electromagnetic transients of the inverter units are modeled at a time step of 100 microseconds. The 3-phase unbalanced distribution feeder that microgrids are connected to is simulated by using the OPAL-RT ePHASORSIM so that load transients, capacitor switching, and tap-changing events can be modeled. A MATLAB-based microgrid controller will interface controllable microgrid components through the Modbus communication. This co-simulation framework allows different microgrid controller logic to be developed and tested on a hardware-in-the-loop testbed considering both the inverter-level transient and the dynamic response of loads and utility equipment. Because the controller communicates with controllable devices via actual communication links, the impact of communication errors, delays, or denial-of-service can also be properly quantified.

Xie, Fuhong↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an Encoding Method on an Co-simulation Platform for Mitigating the Impact of Unreliable Communication

This report presents a hardware-in-the-loop (HIL) based modeling approach for simulating impacts of unreliable communication on the performance of centralized volt-var control and for developing an encoding method to mitigate the impacts. First, an asynchronous real-time HIL simulation platform is introduced to enable multi-rate co-simulation of a distribution system with many inverter-based distributed energy resources (DERs). The distribution system is modeled by milliseconds phasor-based models and the DERs are modeled by micro-seconds power electronic models. Communication connections between a centralized volt-var controller (modeled externally to the HIL testbed) and smart inverters are built by implementing Modbus links and the Long Term Evolution network. On this co-simulation platform, an enhanced, augmented Lagrangian multiplier based encoded data recovery (EALM-EDR) algorithm for mitigating the impact of unreliable communication is developed and validated. Simulation results demonstrate the efficacy of using the HIL-based co-simulation platform as a power grid digital twin for developing algorithms that coordinate a large number of heterogeneous control systems through wired and wireless communication links.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HC-NIDS: signatures and simulations for detecting cyber-attacks aiming to cause damage against cyber-physical energy systems

Physical device safety is typically implemented locally using embedded controllers, while operations safety is primarily performed in control centers. Safe operations can be enhanced by correct design of device-level control algorithms, and protocols, procedures and operator training at the control-room level, but all can fail. Moreover, these elements exchange data and issue commands via vulnerable communication layers. In order to secure these gaps and enhance operational safety, we believe monitoring of command sequences must be combined with an awareness of physical device limitations and automata models that capture safety mechanisms. One way of doing this is by leveraging specification-based intrusion detection to monitor for physical constraint violations. The method can also verify that physical infrastructure state is consistent with monitoring information and control commands exchanged between field devices and control centers. This additional security layer enhances protection from both outsider attacks and insider mistakes. We implemented specification-based SCADA command analyzers using physical constraint algorithms directly in the Bro framework and Broccoli APIs for three separate scenarios: a water heater, an automated distribution system, and an over-current protection scheme. To accomplish this, we added low-level analyzers capable of examining control system-specific protocol packets for both Modbus TCP and DNP3, and also higher-level analyzers able to interpret device command and data streams within the context of each device's physical capabilities and present operational state. Thus the software that we are making available includes the Bro/Broccoli scripts for these three scenarios, as well as simulators, written in C, of those scenarios that generate sample traffic that is monitored by the Bro/Broccoli scripts. In addition, we have also implemented systems to directly pull cyber-physical information from the OSIsoft PI historian system. We have included the Python scripts used to perform that monitoring.

Source record↗

Industrial Control Systems Network Protocol Parsers

Industrial Control Systems protocol parsers plugins for the Zeek network security monitoring framework. Currently we have four fully developed protocol parsers but we plan on adding more in the future. The protocol parsers we currently have developed are for BACnet, DNP3, Ethernet/IP, and Modbus.

Rasmussen, BrettD↗

ManiPIO - Manipulate Process I/O

SAND2021-15053 O ManiPIO is a Python-based tool used to test Programmable Logic Controllers (PLCs), Industrial Control Systems (ICS), and ICS networks. It reads an input script to construct complex Events on ICS networks and uses the ModBus communication standard to communicate. Users can use ManiPIO to construct complex timelines of ICS communication events to simulate any number of network-based scenarios. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hahn, Andrew↗

DER Cybersecurity Detection and Response Suite

SAND2024-08475O The Distributed Energy Resource (DER) Cybersecurity Detection and Response Suite is a solution for distributed energy resource (DER) systems. The DER Security Orchestration, Automation, and Response (SOAR) solution that uses alerts from signature- and behavior-based Intrusion Detection Systems are intended to be deployed as bump-in-the-wire (BITW) devices in front of DER equipment. The fielded application would use multiple intrusion detection systems that report data to SOAR to respond to cyberattacks. The suite consists of two software components: • The proactive intrusion detection and mitigation system (PIDMS) secures grid-edge photovoltaic smart inverters and other equipment in distributed energy resource systems. It is a distributed BITW solution; cyber and physical data are automatically processed using network inspection tools and custom machine learning algorithms to detect abnormal events and correlate cyber-physical events. • The Security Orchestration, Automation, and Response for Distributed Energy Resources (SOAR4DER) application ingests data from several intrusion detection systems to quickly block attacks and revert DER systems to good states. Using a collection of intrusion detection system technologies on a BITW device, it incorporates physical and cyber data to detect abnormal and potential malicious behaviors. Multiple SOAR playbooks then use the intrusion detection system data streams to automatically defend the system. SOAR4DER system testing showed detection and response times under 30 seconds for all adversary reconnaissance, denial-of-service attacks, malicious Modbus commands, brute-force logins, and machine-in-the-middle attacks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗