SEARCH · Engineering Papers
Results for “Modal Testing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
MODAL TESTING OF KDP FLYCUTTING MACHINE VACUUM CHUCKS
Explore the source record for details and available documents.
Modal Testing using the Rattlesnake Vibration Controller
Explore the source record for details and available documents.
Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator
NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.
Modal survey test and model correlation of the CASSIOPE spacecraft
A comprehensive modal survey test based on multi-input multi-output experimental modal analysis techniques was conducted on the flight model of the CASSIOPE spacecraft in the final stages of integration, which included all of the payload and bus instruments and electronics boxes. The multiple-input excitation for the spacecraft was generated using two portable electrodynamic modal shakers installed on the top and bottom of the spacecraft to distribute the excitation energy and the response was measured using 81 miniature accelerometers. Advanced modal analysis software was used to extract modal parameters from the measured data and critical modes were compared with predictions from the finite element model. Most modes identified through the experimental data compared favorably with the predictions. Nevertheless, some differences were large enough to require iterative update of the finite element model. The structural dynamics information from the updated finite element model was used to plan the mechanical vibration qualification test and predict the response of the spacecraft to the launch vehicle environmental loads through coupled loads analysis to provide confidence in the structural integrity of the spacecraft design. This paper describes the details of the methodology used to perform the successful experimental modal test to efficiently extract the critical modes of the spacecraft to correlate with the model.
Executive Summary for the SNL SWIFT V27 Wind Turbine Dynamic Characterization
This final report summarizes ATA Engineering Inc.'s experimental dynamic characterization of the Sandia National Laboratories (SNL) Scaled Wind Farm Technology (SWIFT) Vestas 27 (V27) wind turbine components and fully assembled turbines. Testing was performed at SNL's SWIFT facility in Lubbock, Texas, from October 2012 through June 2013.Dynamic testing consisted of modal testing of the individual blades, the towers in a free-free boundary condition, the towers bolted to the foundations, and the fully assembled wind turbines. Additionally, modal testing was performed on a hub and two nacelles to determine the mass and inertia properties of these components. Details on these tests can be found in their respective reports.
Sandia NRT Blade-0 Laboratory Modal Survey
Modal testing was performed on the Sandia NRT Blade-0 in building A-60 at NREL/NWTC. Modal testing was intended to identify the fundamental frequencies of the blade. The blade was cantilevered to the A-60 test stand. Fundamental frequencies were identified using impact modal testing. Additional tests included free-decay testing to quantify damping at small displacements. Small-displacement modal testing aims to minimize the influence of aerodynamic damping; roaming accelerometer impact testing with the development of a dynamic frame model enabled visualization of mode shapes.
Non-destructive evaluation and machine learning methods for inspection of spent nuclear fuel canisters: A state-of-the-art review
Nuclear energy is among the cleanest and most efficient energy sources currently available. The operation of nuclear power plants (NPPs) produces large amounts of high-level radioactive waste known as spent nuclear fuel (SNF). Currently, large amounts of SNF is stored in dry cask storage systems (DCSSs) for extended interim storage until a permanent disposal solution becomes available. During the extended interim storage, the DCSS, particularly the SNF canisters, may degrade and abnormal conditions may occur. Therefore, non-destructive evaluation (NDE) and machine learning (ML) approaches are necessary for inspection of SNF canisters. This paper presents a state-of-the-art review of literature by summarizing recent progress made on the applications of NDE and ML for inspection of SNF canisters. Sixteen NDE methods are examined and compared: visual inspection, ultrasonic guided waves (UGWs), laser-based approaches, acoustic emission (AE), eddy current testing (ECT), non-invasive acoustic sensing, dynamic modal testing, cosmic ray muons tomography, neutron imaging, gamma rays detection, fiber optical sensors, through-wall communications, X-ray computed tomography (CT), vibrothermography, monoenergetic photon sources, and surface acoustic wave (SAW) sensors. The technology readiness level (TRL) for each method is assessed and compared. Recent publications on ML-enhanced visual inspection, AE, non-invasive acoustic sensing, dynamic modal testing, and neutron imaging for SNF canisters are summarized and future research needs are identified. In conclusion, this review article provides a convenient reference on the state-of-the-art applications of NDE and ML methods for inspection of SNF canisters.
Modal data for the BARC challenge problem Test Report
Modal testing was performed on the uncut BARC structure as a whole and broken into its two sub-assemblies. The structure was placed on soft foam during the test. Excitation was provided with a small modal hammer attached to an actuator. Responses were measured using a 3D Scanning Laser Doppler Vibrometer. Data, shapes, and geometry from this test can be downloaded in Universal File Format from the Sandia Connect SharePoint site.
Shaker-structure interaction modeling and analysis for nonlinear force appropriation testing
Nonlinear force appropriation is an extension of its linear counterpart where sinusoidal excitation is applied to a structure with a modal shaker and phase quadrature is achieved between the excitation and response. While a standard practice in modal testing, modal shaker excitation has the potential to alter the dynamics of the structure under test. Previous studies have been conducted to address several concerns, but this work specifically focuses on a shaker-structure interaction phenomenon which arises during the force appropriation testing of a nonlinear structure. Under pure-tone sinusoidal forcing, a nonlinear structure may respond not only at the fundamental harmonic but also potentially at sub- or superharmonics, or it can even produce aperiodic and chaotic motion in certain cases. Shaker-structure interaction occurs when the response physically pushes back against the shaker attachment, producing non-fundamental harmonic content in the force measured by the load cell, even for pure tone voltage input to the shaker. This work develops a model to replicate these physics and investigates their influence on the response of a nonlinear normal mode of the structure. Experimental evidence is first provided that demonstrates the generation of harmonic content in the measured load cell force during a force appropriation test. This interaction is replicated by developing an electromechanical model of a modal shaker attached to a nonlinear, three-mass dynamical system. Several simulated experiments are conducted both with and without the shaker model in order to identify which effects are specifically due to the presence of the shaker. Finally, the results of these simulations are then compared to the undamped nonlinear normal modes of the structure under test to evaluate the influence of shaker-structure interaction on the identified system’s dynamics.
Ganged Heliostat Modal Memo
This memo documents the methodology and results from the modal tests conducted on the ganged heliostat prototype in April of 2016. Modal tests were conducted on the ganged heliostat prototype constructed at the National Solar Thermal Test Facility (NSTTF) to describe the structures dynamics and examine how the first few modes of vibration may be excited during wind events. This memo documents the experimental test setup and results including natural frequencies and damping estimates for each test conducted along with some preliminary wind excitation analysis.
Modal Analysis and Testing of a Cantilever Beam: Results and Guide
This report discusses modal analysis and testing of a cantilever beam including an introduction to modal testing, simulation, analysis, and a comparison of results. An accompanying presentation can be found from the LLNL CASIS website. Modal testing and analysis are essential for characterizing the response of a structure during vibration environments. Determining natural frequencies and mode shapes helps determine whether resonances will be reached during operations and if so, how the structure will respond and how the response can be tuned. The goal of this work is to convey the basics of modal testing and analysis through a simple project. This can be applied later to more complex, applicable structures. This includes a variety of work including data collection, finite element analysis and data processing. For this project a cantilever beam was chosen because it is a simple, well-characterized structure.
Mechanical Environment Test Specifications Derived from Equivalent Energy in Fixed Base Modes with Frequency Shifts from Unit-to-Unit Variability [Slides]
The outline for this presentation includes: Motivation, Test hardware and loads, Modal test of RC on 6 DOF test fixture, and Analysis--develop one specification accounting for unit-to-unit variability and develop independently tailored test specifications for unit-to-unit variability.
ENSA/DOE Full-scale Rail Cask Multi-Modal Trasnportation Test update.
Abstract not provided.
Surrogate Spent Nuclear Fuel International Multi-Modal Transportation Test.
Abstract not provided.
ENSA/DOE Multi Modal Transportation Tests Preliminary Results.
Abstract not provided.
Multi Modal Transportation Test & Analysis of Results to Date.
Abstract not provided.