Operational and Mission Highlights A Monthly Summary of Top Achievements (March 2021)
Operational and mission highlights for March 2021 for Los Alamos National Laboratory.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Operational and mission highlights for March 2021 for Los Alamos National Laboratory.
The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.
On November 16, Los Alamos National Laboratory Director Thom Mason answered questions from the Defense Nuclear Facilities Safety Board (DNFSB) at a public hearing in Santa Fe about the safety of operations at the Laboratory’s plutonium facility and the pit production mission. Mason participated on a panel along with National Nuclear Security Administration’s (NNSA) Administrator Jill Hruby, Deputy NNSA Administrator James McConnell, and NNSA Los Alamos Field Office Manager Ted Wyka.
To support the Laboratory’s pit mission, the Associate Laboratory Directorate for Plutonium Infrastructure on January 31, 2022, took the first step in establishing operations at TA-55 that run 24 hours a day, seven days a week.
Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.
In September 2020, the Laboratory’s Chemical Microscopy Facility tripled in size, expanding to 1,000 square feet. Located at TA-46, Building158, this facility houses a unique Laboratory resource. Operated by the Physical Chemistry and Applied Spectroscopy (C-PCS) group, this facility was established to renew the Laboratory’s rich history in radiobiology. The facility combines biological research capabilities with isotope production, as well as radioanalytical and chemical infrastructure. This facility provides space for Biosafety Level 2 (BSL-2) research, with alpha-emitting and other radionuclides of interest associated with biological systems. Equipped with a Class ll/A2 biological safety cabinet, a radiological fume hood and a host of other analytical equipment, this facility serves an effective resource to evaluate the efficacy of targeted alpha therapeutics, as well as the deleterious effects of radiological materials on living organisms. The facility receives funding through LDRD- 20180005DR, “Establishing a Radiotherapeutic Capability to Counter Biothreats,” and the BES Heavy Element Chemistry Program at the Laboratory.
This submission contains tarred pair directories for interferometric synthetic aperture radar (InSAR) data covering Coso Geothermal Field in California, USA. Explanation of pair subdirectories: Pairs are formed using the InSAR processing software GMT5SAR (Sandwell et al., 2011). Pair subdirectories are named by starting and ending epochs in YYYYMMDD_YYYYMMDD format. Each tarred pair directory contains GRD files for phase data (radians), unwrapped range change (drhomaskd, in m), and unwrapped range change rate (drange, in m/yr). The data are given in both latitude/longitude and Universal Transverse Mercator (Zone 11N). Raw Synthetic Aperture Radar (SAR) data from the Envisat satellite mission operated by the European Space Agency (ESA) are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility. Raw Synthetic Aperture Radar (SAR) data from the Sentinel-1A satellite mission operated by ESA were available free of charge through the Distributed Active Archive Center (DAAC) at the Alaska Satellite Facility (ASF) and through the Sentinels Scientific Data Hub. References: Farr, T.G.; Rosen, P.A.; Caro, E.; Crippen, R.; Duren, R.; Hensley, S.; Kobrick, M.; Paller, M.; Rodriguez, E.; Roth, L.; Seal, D.; Shaffer, S.; Shimada, J.; Umland, J.; Werner, M.; Oskin, M.; Burbank, D.; Alsdorf, D. The Shuttle Radar Topography Mission. Reviews of Geophysics 2007, 45, RG2004. doi:10.1029/2005RG000183. Sandwell, D.; Mellors, R.; Tong, X.; Wei, M.; Wessel, P. Open radar interferometry software for mapping surface deformation. Eos, Transactions American Geophysical Union 2011, 92, 234?234. http://dx.doi.org/10.1029/2011EO280002. doi:10.1029/2011EO280002.
In this issue, highlights of our outstanding R&D supporting the Laboratory’s nuclear security mission include the following. 1. The essential nuclear materials science contributions of MST’s Materials Properties Team to a range of Lab missions, operations, and initiatives. 2. Work in the Sigma Complex supporting NNSA’s Advanced Manufacturing Development milestones by members of Sigma Division and colleagues across the Laboratory and other NNSA sites. 3. Greg Dale’s role in the Lab’s molybdenum program and today as a technical lead on the Scorpius project. 4. Measurements that reveal the role thermal interfaces play in dynamic compression experiments. 5. The first-ever synthesis of an actinide framework, which offers opportunities for understanding these structures as potential radioactive waste forms and provides new models of actinide species transport in the environment. This issue also showcases, as part of our commitment to simultaneous excellence in mission operations and community relations, the successful high-hazard repair of the LANSCE accelerator, which resulted in a large team Laboratory Distinguished Performance Award, and a virtual Summer Physics Camp for Young Women that brought together participants from around the world, even as COVID kept them socially distant in their homes.
Abstract not provided.
Abstract not provided.
In August 2020, transuranic (TRU) waste inventory onsite at TA-55 fell below 1,500 containers. Multiple groups within the Associate Laboratory Directorate for Weapons Production (ALDWP) have worked collaboratively to achieve this reduction in waste and residue inventory, all within the constraints of COVID-19 safety requirements.
Abstract not provided.
Abstract not provided.
Laboratory personnel working on a years-long Confinement Vessel Disposition (CVD) Project at the Chemistry and Metallurgy Research (CMR) facility recently shipped its first vessel after closing the emptying and dispositioning portion of the project in 2020. During the 1970s and 1980s, the Laboratory conducted experiments that produced data used in computer modeling. Scientists used these models to evaluate the performance of nuclear weapons.
Working with the Design Agency (Q-6), Production Agency Quality (PAQ) Division, and the NNSA Los Alamos Field Office, Detonator Production recently sold Lot 3354 to NNSA. Detonator Production personnel shipped the lot to Pantex — the Laboratory will continue to support the W76 into the future. The sale and shipment of Lot 3354 was accomplished before the closeout of FY21, achieving a key milestone that required active participation from several stakeholders within the Lab, as well as organizations external to the Laboratory. Both organizations found remedies to address challenges associated with this lot that had persisted since 2019.
A monthly summary of top achievements.
Abstract not provided.
Abstract not provided.