Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Heating And Positioning In A Microwave Cavity

Two reports describe theoretical and experimental studies of microwave dielectrophoretic positioning of spherical sample of lossy dielectric material in microwave resonant cavity and heating of positioned sphere by electro-magnetic field. Studies part of continuing effort to develop techniques for containerless processing of materials in microgravity. Previous studies in this series described in "Microwave Dielectrophoretic Levitation in Microgravity" (NPO-18824).

Jackson, Henry W.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.

microwave↗

Experimental performance of a microwave cavity plasma disk ion source

The detailed description and performance characteristics of a microwave ion source are presented. This ion source utilizes an internally tuned, single-mode (or selective multimode) cylindrical cavity applicator to focus and match microwave energy into a disk-shaped discharge zone. The combination of mode focus control and variable, internal cavity matching allows the efficient operation and beam extraction over a wide range of pressures, powers and gaseous inputs. Experimental measurements of ion beam current versus accelerating voltage and input microwave power in xenon and oxygen gas are presented. Ion source specific energy and mass utilization versus experimental variables are also determined. The experimental performance demonstrates the ability of this ion source to extract an ion beam with a well matched, stable, and continuous operation over a wide range of input gases, low pressures, and over input gas flow rates in excess of 100 to a few sccm. Double Langmuir probe measurements in xenon gas indicate high degrees of ionization, and electron and ion concentrations in excess of 100 critical densities in the microwave discharge zone. This ion source has many potential uses such as spacecraft electric propulsion, material ion beam processing, and neutral beam ion sources.

Root, J.↗

(abstract) Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

We have developed a vibration technique to continuously maintain mode resonance and impedance match between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity that is equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub tuner. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time plotswill be presented for the cases of no tracking, impedance tracker only, mode tracker only, and simultaneous impedance and mode tracking. Internal melting of the alumina rod near 2000°C with both trackers on will also be discussed.

microwave↗

Integral storage-bulb and microwave cavity for masers

Mechanically-stable integral storage-bulb/microwave cavity made out of single piece of fused quartz improves frequency stability. Single-piece construction eliminates joints, making cavity dimensionally and hence frequency-stable. Fused quartz is used because of its low thermal expansion coefficient.

Reinhardt, V. S.↗

Research relative to the development of a cryogenic microwave cavity gradiometer for orbital use

The noncryogenic, single axis, gravity gradiometer which is characterized by a sensitivity of the order of 10 to the minus 2 power Eovos Units in a few sec integration time was investigated. The prototype of testing gradiometer on the earth surface by the free fall in vacuo method was expanded. An existing free fall tower facility and the possibility of adding inside the falling elevator cabin an air tight, sealed, cylindrical container with inside pressure or = -0.001 Torr were examined to test the gradiometer in free fall conditions inside this evacuated container. Earth's gravity anomalies are simulated with masses of suitable shape, weight, and location. The attitude of the falling gradiometer is monitored by a three axis gyro package mounted on the instrument package. It is concluded that the free fall testing of the gradiometer is both feasible and practical.

Grossi, M. D.↗

Research relative to the development of a cryogenic microwave cavity gradiometer for orbital use

Technical approaches to increase the sensitivity of a non-cryogenic gradiometer toward the goal of 0.001 EU/square root of Hz, with solutions that have the potential of achieving an even more ambitious threshold, such as 0.0001 EU/square root of Hz are discussed. This goal can be achieved with a gradiometer design in which the proof masses are each suspended from two small arms, the torsion of which is directly related to the displacement of the sensing element. A negative-spring action, aimed at reducing the resonance frequency, is provided in this design by means of an external electrostatic field. This configuration of the instrument is also suitable for use in a tensorial arrangement.

Grossi, M. D.↗

Measurement of individual hydrometeor absorption cross sections utilizing microwave cavity perturbation techniques

A technique for measurement of individual hydrometeor absorption cross sections is presented. Cross sections are inferred by inserting the hydrometeor into a high Q resonant cavity and measuring the Q perturbation. Tests were conducted in a 10.64 GHz, TM(010) cavity. Absorption cross sections were measured at room temperature for 0.5 to 2.0 mm water drops, and were found to agree with the Rayleigh theory. Cross sections were also measured as a function of temperature, and from these the dielectric loss term lm(-K) was inferred for supercooled water down to -17 C.

Hansman, R. J., Jr.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

A vibration technique his been developed to continuously maintain mode resonance and impedance much between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity in a manner equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub turner during processing. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time heating curves are presented for the cases of no tracking, impedance tracker only, mode tracker only and simultaneous impedance and mode tracking. Controlled internal melting of an alumina rod near 2000 C using both tracking units was also demonstrated.

Barmatz, M.↗

Electromagnetic plasma models for microwave plasma cavity reactors

A procedure used to design cavity applicators that efficiently produce cylindrical and disk microwave discharges is reviewed. In contrast to most microwave applicators these cavities utilize single mode excitation of the plasma. This method of excitation has the advantage of providing efficient coupling (zero reflected power) to the plasma over a wide range of discharge loading conditions while also allowing, if desired, electric feedback control of the heating process. The design procedure is generalized to any lossy dielectric. Experimental and theoretical research required to further understand microwave discharges is also discussed.

Frasch, L.↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

Hydrogen maser clocks in space for solid-Earth research and time-transfer applications: Experiment overview and evaluation of Russian miniature sapphire loaded cavity

The Observatoire Cantonal de Neuchatel (ON) is developing for ESTEC a compact H-maser for space use based upon a miniature sapphire loaded microwave cavity, a technique pioneered at VNIIFTRI. Various contacts between West-European parties, headed by ESA, and the Russian parties, headed by ESA, led to the proposal for flying two H-masers on Meteor 3M, a Russian meteorology satellite in low polar orbit. The experiment will include two masers, one provided by ON and the other by VNIIFTRI. T/F transfer and precise positioning will be performed by both a microwave link, using PRARE equipment, and an optical link, using LASSO-like equipment. The main objectives of the experiment are precise orbit determination and point positioning for geodetic/geophysical research, ultra-accurate time comparison and dissemination as well as in-orbit demonstration of operation and performance of H-masers. Within the scope of a preliminary space H-maser development phase performed for ESTEC at ON in preparation to the joint experiment, a Russian miniature sapphire loaded microwave cavity, on loan from VNIIFTRI, was evaluated in a full-size EFOS hydrogen maser built by ON. The experimental evaluation confirmed the theoretical expectation that with a hydrogen storage volume of only 0.65 liter an atomic quality factor of 1.5 x 10(exp 9) can be obtained for a -105 dBm output power. This represents a theoretical Allan deviation of 1.7 x 10(exp -15) averaged on a 1000 s time interval. From a full-size design to a compact one, therefore, the sacrifice in performance due to the reduction of the storage volume is very small.

Busca, G.↗

Development of a cryogenic hydrogen maser at the NPL

A prototype Cold Hydrogen Maser (CHM) was being developed for the past year. The features of this CHM, which is designed to operate initially at 4.2 K, are the use of low loss alumina, and later sapphire, in the fabrication of the microwave cavity; possible use of superconductors for shielding; use of a cryogenic amplifier; possible coating material; and a reliable RF discharge circuit for the dissociation of hydrogen. A numerical simulation was performed to find the dimensions of the microwave cavity for the TE011 mode and the model was confirmed experimentally. The system will be used to test various wall coatings adsorbed on top of a PTFE buffer underlayer. The CHM is expected to be used as a flywheel frequency standard at the NPL with medium-term stability of one part in 10(exp 14) or better.

Mossavati, R.↗