At least 37 records · Page 2

Monopole antenna in quantitative near-field microwave microscopy of planar structures

We have developed an analytical model of a near-field microwave microscope based on a coaxial resonator with a sharpened tip probe. The probe interacts with a layered sample that features an arbitrary depth distribution of permittivity. The microscopic tip end with the accumulated charge is regarded as a monopole antenna radiating an electric field in near zone. The impedance of such an antenna is determined within a quasi-static approximation. The proposed model is used for calculating the sample-sensitive parameters of the microscope, specifically, resonance frequency f{sub 0} and quality factor Q{sub 0}, as a function of probe-sample distance h. The theory has been verified experimentally in studies of semiconductor structures, both bulk and thin films. For measurements, we built a ∼2.1 GHz microscope with an effective tip radius of about 100 μm. The theoretical and experimental dependences f{sub 0}(h) and Q{sub 0}(h) were found to be in a good agreement. The developed theory underlies the method for determining sheet resistance R{sub sh} of a semiconductor film on a dielectric substrate proposed in this article. Studies were performed on doped n-GaN films on an Al{sub 2}O{sub 3} substrate. The effective radius and height of the probe determined from calibration measurements of etalon samples were used as the model fitting parameters. For etalon samples, we employed homogeneous sapphire and doped silicon plates. We also performed four-probe dc measurements of R{sub sh}. The corresponding values for samples with R{sub sh} > 1 kΩ were found to be 50% to 100% higher than the microwave results, which are attributed to the presence of microdefects in semiconductor films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reflective mode X-ray microscopy of inclined objects

We propose an optical configuration of a reflective mode X-ray microscope which operates by the reflection of radiation incident on an object at grazing incidence. Primary emphasis is placed on the image recording with minimal aberrations. Numerical simulations are used to estimate the spatial resolution and the field of view, and a comparison is made with the results of investigation of surface-modified objects with a reflective mode X-ray laser microscope operating at a wavelength of 14.9 nm. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mask inspection microscopy with 13.2 nm table-top laser illumination

We report the demonstration of a reflection microscope that operates at 13.2-nm wavelength with a spatial resolution of 55 {+-} 3 nm. The microscope uses illumination from a table-top EUV laser to acquire aerial images of photolithography masks with a 20 second exposure time. The modulation transfer function of the optical system was characterized.

36 MATERIALS SCIENCE↗

Investigation of early growth of calcium hydroxide crystals in cement solution by soft x-ray transmission microscopy

Research on cement hydration was performed at the full-field soft transmission X-ray microscope XM-1 located at beamline 6.1.2 at the Advanced Light Source (ALS) in Berkeley CA which is operated by the Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California. A series of works [1-3] has been conducted using this microscope for the in situ observation and qualitative analysis of through-solution hydration products and products of topochemical reactions, which form in cementitious aqueous solutions. This paper studies the precipitation of the calcium hydroxide (CH) crystals from the cement solution. The analysis of successive images of the hydration process provides critical quantitative information about the growth rate of calcium hydroxide (CH) crystals, the supersaturation ratio, and the kinetic and diffusion coefficients of the growth process. ASTM Type II portland cement and 6% C{sub 4}A{sub 3}{bar S} admixture were mixed in aqueous solution and saturated with respect to CH and gypsum. The C{sub 4}A{sub 3}{bar S} admixture was included in the experimental program because of the general research program on expansive cements, and adding C{sub 4}A{sub 3}{bar S} to portland cement is an efficient method of generating ettringite and significant early-age expansion. The solution/solid materials ratio was 10 cm{sup 3}/g, which is higher than the one existing in regular concrete and mortars; to compensate for this dilution, the solution was originally saturated with CH and gypsum. To allow sufficient transmission of the soft X-rays, a small droplet was taken from the supernatant solution and assembled in the sample holder, and then squeezed between two silicon nitride windows for the analysis. The X-ray optical setup of the microscope XM-1 is described elsewhere [2]. In this experiment, a wavelength of 2.4 nm (516.6 eV) was used. The radiation transmitting the sample was detected using an X-ray CCD camera, with a resolution of 35 nm provided by Fresnel zone plate X-ray optics and magnification factor of about 2000. The recorded images have a circular field of view of approximately 10 {micro}m in diameter. The illumination time per image was in the range of 1 to 14 seconds depending largely on the absorption of the sample. The experimental work was conducted at room temperature T = 298 K.

36 MATERIALS SCIENCE↗

Precise and direct method for the measurement of the torsion spring constant of the atomic force microscopy cantilevers

A direct method for the evaluation of the torsional spring constants of the atomic force microscope cantilevers is presented in this paper. The method uses a nanoindenter to apply forces at the long axis of the cantilever and in the certain distance from it. The torque vs torsion relation is then evaluated by the comparison of the results of the indentations experiments at different positions on the cantilever. Next, this relation is used for the precise determination of the torsional spring constant of the cantilever. The statistical analysis shows that the standard deviation of the calibration measurements is equal to approximately 1%. Furthermore, a simple method for calibration of the photodetector’s lateral response is proposed. The overall procedure of the lateral calibration constant determination has the accuracy approximately equal to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact high-resolution differential interference contrast soft x-ray microscopy

We demonstrate high-resolution x-ray differential interference contrast (DIC) in a compact soft x-ray microscope. Phase contrast imaging is enabled by the use of a diffractive optical element objective which is matched to the coherence conditions in the microscope setup. The performance of the diffractive optical element objective is evaluated in comparison with a normal zone plate by imaging of a nickel siemens star pattern and linear grating test objects. Images obtained with the DIC optic exhibit typical DIC enhancement in addition to the normal absorption contrast. Contrast transfer functions based on modulation measurements in the obtained images show that the DIC optic gives a significant increase in contrast without reducing the spatial resolution. The phase contrast operation mode now available for our compact soft x-ray microscope will be a useful tool for future studies of samples with low absorption contrast.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research of the tritium saturation, isotope diffusion and decontamination of stainless steel using magnetic microscopy

The investigations of the tritium distribution in a surface layer and in the depth of samples using a magnetic microscope were carried out. The dependence of a saturation level in the boundary layer for hydrogen was established from a preliminary examination of samples. Conservation of the tritium distribution profile in the depth of the stainless steel samples after completion of their saturation and cooling was assigned. For Inconel-625 substantial tritium redistribution and release during storage (300 K, 15 and 28 months) were experimentally ascertained to a greater degree satisfies the classical characteristics of the diffusion process. The 'braking' effect of tritium diffusion was found by preliminary saturation of samples by hydrogen. Research in tritium decontamination effects for samples saturated with tritium with various technological preparation was carried out and essential increase of its efficiency was founded. The experiments emulated a model of technological operation cycle of the thermonuclear reactor. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent X-Ray Diffraction Imaging with Nanofocused Illumination

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions {approx_equal}100x100 nm{sup 2}) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Ultrahigh-Resolution Soft-X-Ray Microscopy with Zone Plates in High Orders of Diffraction

We present an x-ray optical approach to overcome the current limitations in spatial resolution of x-ray microscopes. Our new BESSY full-field x-ray microscope operates with an energy resolution up to E/DELTAE=10{sup 4}. We demonstrate that under these conditions it is possible to employ high orders of diffraction for imaging. Using the third order of diffraction of a zone plate objective with 25 nm outermost zone width, 14 nm lines and spaces of a multilayer test structure were clearly resolved. We believe that high-order imaging paves the way towards sub-10-nm real space x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Hall probe microscopy of a diluted magnetic semiconductor

We have measured the micromagnetic properties of a diluted magnetic semiconductor as a function of temperature and applied field with a scanning Hall probe microscope built in our laboratory. The design philosophy for this microscope and some details are described. The samples analyzed in this work are Ga{sub 0.94}Mn{sub 0.06}As films grown by molecular beam epitaxy. We find that the magnetic domains are 2-4 mum wide and fairly stable with temperature. Magnetic clusters are observed above T{sub C}, which we ascribe to MnAs defects too small and sparse to be detected by a superconducting quantum interference device magnetometer.

36 MATERIALS SCIENCE↗

Scanning Josephson Tunneling Microscopy of Single Crystal Bi2Sr2CaCu2O8+delta with a Conventional Superconducting Tip

We have performed both Josephson and quasiparticle tunneling in vacuum tunnel junctions formed between a conventional superconducting scanning tunneling microscope tip and overdoped Bi2Sr2CaCu2O8+ single crystals. A Josephson current is observed with a peak centered at a small finite voltage due to the thermal-fluctuation-dominated superconducting phase dynamics. Josephson measurements at different surface locations yield local values for the Josephson ICRN product. Corresponding energy gap measurements were also performed and a surprising inverse correlation was observed between the local ICRN product and the local energy gap.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Interaction of an 180o Ferroelectric Domain Wall with a Biased Scanning Probe Microscopy Tip: Effective Wall Geometry and Thermodynamics in Ginzburg-Landau-Devonshire Theory

The interaction of ferroelectric 180o-domain wall with a strongly inhomogeneous electric field of biased Scanning Probe Microscope tip is analyzed within continuous Landau-Ginzburg-Devonshire theory. Equilibrium shape of the initially flat domain wall boundary bends, attracts or repulses from the probe apex, depending on the sign and value of the applied bias. For large tip-wall separations, the probe-induced domain nucleation is possible. The approximate analytical expressions for the polarization distribution are derived using direct variational method. The expressions provide insight how the equilibrium polarization distribution depends on the wall finite-width, correlation and depolarization effects, electrostatic potential distribution of the probe and ferroelectric material parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hard x-ray nanobeam characterization by coherent diffraction microscopy

We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stereo soft x-ray microscopy and elemental mapping of hematite and clay suspensions

The spatial arrangements of hematite particles within aqueous soil and clay samples are investigated with soft X-ray microscopy, taking advantage of the elemental contrast at the Fe-L edge around E = 707 eV. In combination with stereo microscopy, information about spatial arrangements are revealed and correlated to electrostatic interactions of the different mixtures. Manipulation of a sample mounted to the microscope is possible and particles added while imaging can be detected.

36 MATERIALS SCIENCE↗