Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Light Microscopy Module: On-Orbit Microscope Planned for the Fluids Integrated Rack on the International Space Station

The Light Microscopy Module (LMM) is planned as a remotely controllable, automated, on-orbit facility, allowing flexible scheduling and control of physical science and biological science experiments within the Fluids Integrated Rack (FIR) on the International Space Station. Initially four fluid physics experiments in the FIR will use the LMM the Constrained Vapor Bubble, the Physics of Hard Spheres Experiment-2, Physics of Colloids in Space-2, and Low Volume Fraction Entropically Driven Colloidal Assembly. The first experiment will investigate heat conductance in microgravity as a function of liquid volume and heat flow rate to determine, in detail, the transport process characteristics in a curved liquid film. The other three experiments will investigate various complementary aspects of the nucleation, growth, structure, and properties of colloidal crystals in microgravity and the effects of micromanipulation upon their properties.

Motil, Susan M.↗

A Comparison of Image Quality Evaluation Techniques for Transmission X-Ray Microscopy

Beamline 6-2c at Stanford Synchrotron Radiation Lightsource (SSRL) is capable of Transmission X-ray Microscopy (TXM) at 30 nm resolution. Raw images from the microscope must undergo extensive image processing before publication. Since typical data sets normally contain thousands of images, it is necessary to automate the image processing workflow as much as possible, particularly for the aligning and averaging of similar images. Currently we align images using the 'phase correlation' algorithm, which calculates the relative offset of two images by multiplying them in the frequency domain. For images containing high frequency noise, this algorithm will align noise with noise, resulting in a blurry average. To remedy this we multiply the images by a Gaussian function in the frequency domain, so that the algorithm ignores the high frequency noise while properly aligning the features of interest (FOI). The shape of the Gaussian is manually tuned by the user until the resulting average image is sharpest. To automatically optimize this process, it is necessary for the computer to evaluate the quality of the average image by quantifying its sharpness. In our research we explored two image sharpness metrics, the variance method and the frequency threshold method. The variance method uses the variance of the image as an indicator of sharpness while the frequency threshold method sums up the power in a specific frequency band. These metrics were tested on a variety of test images, containing both real and artificial noise. To apply these sharpness metrics, we designed and built a MATLAB graphical user interface (GUI) called 'Blur Master.' We found that it is possible for blurry images to have a large variance if they contain high amounts of noise. On the other hand, we found the frequency method to be quite reliable, although it is necessary to manually choose suitable limits for the frequency band. Further research must be performed to design an algorithm which automatically selects these parameters.

99 GENERAL AND MISCELLANEOUS↗

Whole-Cell Scan using Automatic Variable-Angle and Variable-Illumination-Depth Pseudo—Total Internal Reflection Fluorescence Microscopy

An automatic calibration and angle-scanning prism-type total internal reflection fluorescence microscope (TIRFM) was modified to function in both TIRFM and pseudo-TIRFM modes. When the incident angle of the excitation laser beam was controlled to be larger than the critical angle, the instrument served as a variable-angle TIRFM. A homemade computer program automatically calibrates the laser illumination spot in the sample to overlap with the center of the microscope's field of view. Then, by measuring the fluorescence intensities at different incident angles, the z-positions of fluorescent nanospheres close to the cell basolateral membrane can be extracted. When the incident angle is reduced to be in the subcritical range, the instrument works as a pseudo-TIRFM. The whole cell body from bottom to top can be imaged in a vertical scan process. Furthermore, the illumination field depth in the pseudo-TIRFM can be controlled by changing the incident angle or the horizontal position of the laser spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Information Acquisition & Processing in Scanning Probe Microscopy

Much of the imaging and spectroscopy capabilities of the existing 20,000+ scanning probe microscopes worldwide relies on specialized data processing that links the microsecond (and sometimes faster) time scale of cantilever motion to the millisecond (and sometimes slower) time scale of image acquisition and feedback. In most SPMs, the cantilever is excited to oscillate sinusoidally and the time-averaged amplitude and/or phase are used as imaging or control signals. Traditionally, the step of converting the rapid motion of the cantilever into an amplitude or phase is performed by phase sensitive homodyne or phase-locked loop detection. The emergence of fast configurable data processing electronics in last several years has allowed the development of non-sinusoidal data acquisition and processing methods. Here, we briefly review the principles and limitations of phase sensitive detectors and discuss some of the emergent technologies based on rapid spectroscopic measurements in frequency- and time domains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Domain-wall oscillations studies by time-resolved soft x-ray mircorscopy

Fast magnetization dynamics in the micro- and nanometer regime are an interesting field of research. On these length scales magnetic structures can be designed to contain a single vortex or a single domain wall. Both size and speed of these patterns are of great interest in todays research for prospective non-volatile data storage devices. Especially the possibility to move domain-walls by spin-polarized current gained a lot of interest. Magnetic configurations can be imaged by soft X-ray magnetic microscopy with a spatial resolution down to 15 nm. By a stroboscopic pump and probe measurement scheme a temporal resolution below 100 ps is achieved. This provides the opportunity to directly image changes in magnetic domains and domain-wall motion. We image oscillations of a single domain wall in a confining potential in time steps of 200 ps by time resolved X-ray microscopy at the full-field soft X-ray transmission microscope at the Advanced Light Source in Berkeley (beamline 6.1.2). Domain walls are prepared in permalloy nanostructures with a restoring potential. The oscillation of a 180{sup o} domain wall is triggered by nanosecond current pulses. The spin-polarized current and the accompanying Oersted field can contribute to the motion of the wall. By analysis of the distinct domain-wall dynamics the dominant contribution is determined. In our geometry the motion of the wall is determined by the Oersted field although the spin-polarized current directly flows through the ferromagnetic structure. An analytical model of a rigid particle precisely describes the domain-wall motion. Oscillations are studied for different pulse length and amplitudes. From the observed oscillations we extract the driving force, the confining potential, and the domain-wall mass. Nonharmonic terms determine the motion of the wall. The influence of the nonharmonic potential is studied by looking at various phase spaces of the domain-wall motion.

36 MATERIALS SCIENCE↗

Monopole antenna in quantitative near-field microwave microscopy of planar structures

We have developed an analytical model of a near-field microwave microscope based on a coaxial resonator with a sharpened tip probe. The probe interacts with a layered sample that features an arbitrary depth distribution of permittivity. The microscopic tip end with the accumulated charge is regarded as a monopole antenna radiating an electric field in near zone. The impedance of such an antenna is determined within a quasi-static approximation. The proposed model is used for calculating the sample-sensitive parameters of the microscope, specifically, resonance frequency f{sub 0} and quality factor Q{sub 0}, as a function of probe-sample distance h. The theory has been verified experimentally in studies of semiconductor structures, both bulk and thin films. For measurements, we built a ∼2.1 GHz microscope with an effective tip radius of about 100 μm. The theoretical and experimental dependences f{sub 0}(h) and Q{sub 0}(h) were found to be in a good agreement. The developed theory underlies the method for determining sheet resistance R{sub sh} of a semiconductor film on a dielectric substrate proposed in this article. Studies were performed on doped n-GaN films on an Al{sub 2}O{sub 3} substrate. The effective radius and height of the probe determined from calibration measurements of etalon samples were used as the model fitting parameters. For etalon samples, we employed homogeneous sapphire and doped silicon plates. We also performed four-probe dc measurements of R{sub sh}. The corresponding values for samples with R{sub sh} > 1 kΩ were found to be 50% to 100% higher than the microwave results, which are attributed to the presence of microdefects in semiconductor films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reflective mode X-ray microscopy of inclined objects

We propose an optical configuration of a reflective mode X-ray microscope which operates by the reflection of radiation incident on an object at grazing incidence. Primary emphasis is placed on the image recording with minimal aberrations. Numerical simulations are used to estimate the spatial resolution and the field of view, and a comparison is made with the results of investigation of surface-modified objects with a reflective mode X-ray laser microscope operating at a wavelength of 14.9 nm. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mask inspection microscopy with 13.2 nm table-top laser illumination

We report the demonstration of a reflection microscope that operates at 13.2-nm wavelength with a spatial resolution of 55 {+-} 3 nm. The microscope uses illumination from a table-top EUV laser to acquire aerial images of photolithography masks with a 20 second exposure time. The modulation transfer function of the optical system was characterized.

36 MATERIALS SCIENCE↗

Investigation of early growth of calcium hydroxide crystals in cement solution by soft x-ray transmission microscopy

Research on cement hydration was performed at the full-field soft transmission X-ray microscope XM-1 located at beamline 6.1.2 at the Advanced Light Source (ALS) in Berkeley CA which is operated by the Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California. A series of works [1-3] has been conducted using this microscope for the in situ observation and qualitative analysis of through-solution hydration products and products of topochemical reactions, which form in cementitious aqueous solutions. This paper studies the precipitation of the calcium hydroxide (CH) crystals from the cement solution. The analysis of successive images of the hydration process provides critical quantitative information about the growth rate of calcium hydroxide (CH) crystals, the supersaturation ratio, and the kinetic and diffusion coefficients of the growth process. ASTM Type II portland cement and 6% C{sub 4}A{sub 3}{bar S} admixture were mixed in aqueous solution and saturated with respect to CH and gypsum. The C{sub 4}A{sub 3}{bar S} admixture was included in the experimental program because of the general research program on expansive cements, and adding C{sub 4}A{sub 3}{bar S} to portland cement is an efficient method of generating ettringite and significant early-age expansion. The solution/solid materials ratio was 10 cm{sup 3}/g, which is higher than the one existing in regular concrete and mortars; to compensate for this dilution, the solution was originally saturated with CH and gypsum. To allow sufficient transmission of the soft X-rays, a small droplet was taken from the supernatant solution and assembled in the sample holder, and then squeezed between two silicon nitride windows for the analysis. The X-ray optical setup of the microscope XM-1 is described elsewhere [2]. In this experiment, a wavelength of 2.4 nm (516.6 eV) was used. The radiation transmitting the sample was detected using an X-ray CCD camera, with a resolution of 35 nm provided by Fresnel zone plate X-ray optics and magnification factor of about 2000. The recorded images have a circular field of view of approximately 10 {micro}m in diameter. The illumination time per image was in the range of 1 to 14 seconds depending largely on the absorption of the sample. The experimental work was conducted at room temperature T = 298 K.

36 MATERIALS SCIENCE↗

Precise and direct method for the measurement of the torsion spring constant of the atomic force microscopy cantilevers

A direct method for the evaluation of the torsional spring constants of the atomic force microscope cantilevers is presented in this paper. The method uses a nanoindenter to apply forces at the long axis of the cantilever and in the certain distance from it. The torque vs torsion relation is then evaluated by the comparison of the results of the indentations experiments at different positions on the cantilever. Next, this relation is used for the precise determination of the torsional spring constant of the cantilever. The statistical analysis shows that the standard deviation of the calibration measurements is equal to approximately 1%. Furthermore, a simple method for calibration of the photodetector’s lateral response is proposed. The overall procedure of the lateral calibration constant determination has the accuracy approximately equal to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact high-resolution differential interference contrast soft x-ray microscopy

We demonstrate high-resolution x-ray differential interference contrast (DIC) in a compact soft x-ray microscope. Phase contrast imaging is enabled by the use of a diffractive optical element objective which is matched to the coherence conditions in the microscope setup. The performance of the diffractive optical element objective is evaluated in comparison with a normal zone plate by imaging of a nickel siemens star pattern and linear grating test objects. Images obtained with the DIC optic exhibit typical DIC enhancement in addition to the normal absorption contrast. Contrast transfer functions based on modulation measurements in the obtained images show that the DIC optic gives a significant increase in contrast without reducing the spatial resolution. The phase contrast operation mode now available for our compact soft x-ray microscope will be a useful tool for future studies of samples with low absorption contrast.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research of the tritium saturation, isotope diffusion and decontamination of stainless steel using magnetic microscopy

The investigations of the tritium distribution in a surface layer and in the depth of samples using a magnetic microscope were carried out. The dependence of a saturation level in the boundary layer for hydrogen was established from a preliminary examination of samples. Conservation of the tritium distribution profile in the depth of the stainless steel samples after completion of their saturation and cooling was assigned. For Inconel-625 substantial tritium redistribution and release during storage (300 K, 15 and 28 months) were experimentally ascertained to a greater degree satisfies the classical characteristics of the diffusion process. The 'braking' effect of tritium diffusion was found by preliminary saturation of samples by hydrogen. Research in tritium decontamination effects for samples saturated with tritium with various technological preparation was carried out and essential increase of its efficiency was founded. The experiments emulated a model of technological operation cycle of the thermonuclear reactor. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent X-Ray Diffraction Imaging with Nanofocused Illumination

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions {approx_equal}100x100 nm{sup 2}) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Scanning electron microscopy of the vestibular end organs

The vestibular end organs, after chemical fixation, were freeze dried, coated with gold and palladium, and studied in the scanning microscope. Scanning microscopy gives a good three dimensional view of the sensory areas and allows study of both gross anatomy and microstructures. Cross anatomical features of the structure of the ampullae are demonstrated. The form of the statoconia in different species of animals is shown. New aspects of the structure of the sensory hairs are revealed. The hair bundles in the central areas of the cristae and in the striola of the maculae differ structurally from the hair bundles at the periphery of the sensory regions. Furthermore, some hair bundles consisting of very short stereocilia were observed. The relationship between the cupula and the statoconial membrane to the epithelial surface is discussed.

Lindeman, H. H.↗