Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mesoscale systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrical and kinematic structure of an Oklahoma mesoscale convective system

The case study examines the dynamics and kinematics of a mesoscale convective system (MCS) by comparing its meteorological parameters with in situ electrical measurements. Conventional MCS characteristics are reported including a rear inflow jet, wake low, and a bipolar cloud-to-ground pattern, but some nonclassical conditions are also reported. Horizontally long cloud-to-ground electrical strikes are noted which demonstrate that cloud-to-ground electrical data alone cannot entirely characterize stratiform electrification in MCSs.

Hunter, Steven M.↗

A multiparameter radar examination of a mesoscale convective system

Differences in the rainrates of various cells embedded within a mesoscale convective system on July 13, 1986 during the Cooperative Huntsville Meteorological experiment are examined. The NCAR CP2 S-band polarimetric radar deployed near Huntsville, Alabama, is used to characterize the rainfall field. Rainfall estimates are compared and contrasted using the single-parameter Marshall and Palmer (1948) method with the Illingworth and Caylor (1989) dual-polarization technique (ILC). The primary differences in the rainrate estimates are shown to be associated with the differences in the drop size distributions, derived from the ILC technique, that occur within the various storms.

Wright, P. D.↗

The radiative budgets of a tropical mesoscale convective system during the EMEX-STEP-AMEX experiment. I - Observations. II - Model results

The spatial radiation heating budget associated with tropical mesoscale convective systems (MCSs) is studied and the change of this heating/budget throughout the life cycle of such a cloud system is investigated. The movements of an EMEX 9 cloud cluster are described. The vertical structure of the cluster contains two types of imbedded convection: an upright vertical structure and a pronounced rearward slope with vertical extent of 14.5 km or more and a horizontal scale of about 40 km. The cloud base and cloud top altitude in the stratiform region are of the order of 4.8 km and 15-16 km, respectively. The upward and downward solar flux profiles suggest very little solar heating in these regions. A tropical MCS that occurred during the EMEX Mission 9 is simulated, and the simulation is shown to broadly agree with the observations. The simulation results, which are reported in detail, show how tropical mesoscale cloud systems provide an effective radiative heat source for the tropical atmosphere.

Wong, Takmeng↗

The Impact of Microphysics on Intensity and Structure of Hurricanes and Mesoscale Convective Systems

During the past decade, both research and operational numerical weather prediction models, e.g. Weather Research and Forecast (WRF) model, have started using more complex microphysical schemes originally developed for high-resolution cloud resolving models (CRMs) with a 1-2 km or less horizontal resolutions. WRF is a next-generation mesoscale forecast model and assimilation system that has incorporated modern software framework, advanced dynamics, numeric and data assimilation techniques, a multiple moveable nesting capability, and improved physical packages. WRF model can be used for a wide range of applications, from idealized research to operational forecasting, with an emphasis on horizontal grid sizes in the range of 1-10 km. The current WRF includes several different microphysics options such as Purdue Lin et al. (1983), WSM 6-class and Thompson microphysics schemes. We have recently implemented three sophisticated cloud microphysics schemes into WRF. The cloud microphysics schemes have been extensively tested and applied for different mesoscale systems in different geographical locations. The performances of these schemes have been compared to those from other WRF microphysics options. We are performing sensitivity tests in using WRF to examine the impact of six different cloud microphysical schemes on precipitation processes associated hurricanes and mesoscale convective systems developed at different geographic locations [Oklahoma (IHOP), Louisiana (Hurricane Katrina), Canada (C3VP - snow events), Washington (fire storm), India (Monsoon), Taiwan (TiMREX - terrain)]. We will determine the microphysical schemes for good simulated convective systems in these geographic locations. We are also performing the inline tracer calculation to comprehend the physical processes (i.e., boundary layer and each quadrant in the boundary layer) related to the development and structure of hurricanes and mesoscale convective systems.

Tao, Wei-Kuo↗

Evaluating and Understanding Parameterized Convective Processes and Their Role in the Development of Mesoscale Precipitation Systems

Research efforts during the first year focused on numerical simulations of two convective systems with the Penn State/NCAR mesoscale model. The first of these systems was tropical cyclone Irma, which occurred in 1987 in Australia's Gulf of Carpentaria during the AMEX field program. Comparison simulations of this system were done with two different convective parameterization schemes (CPS's), the Kain-Fritsch (1993 - KF) and the Betts-Miller (Betts 1986- BM) schemes. The second system was the June 10-11 1985 squall line simulation, which occurred over the Kansas-Oklahoma region during the PRE-STORM experiment. Simulations of this system using the KF scheme were examined in detail.

Fritsch, J. Michael↗

Evaluating and Understanding Parameterized Convective Processes and Their Role in the Development of Mesoscale Precipitation Systems

Research efforts focused on numerical simulations of two convective systems with the Penn State/NCAR mesoscale model. The first of these systems was tropical cyclone Irma, which occurred in 1987 in Australia's Gulf of Carpentaria during the AMEX field program. Comparison simulations of this system were done with two different convective parameterization schemes (CPS's), the Kain-Fritsch (KF) and the Betts-Miller (BM) schemes. The second system was the June 10-11, 1985 squall line simulation, which occurred over the Kansas-Oklahoma region during the PRE-STORM experiment. Simulations of this system using the KF scheme were examined in detail.

Fritsch, J. Michael↗

Observed structural variability of deep moist convection within a mesoscale convective system

Some radar observations of the convective cloud structure within and around a developing mesoscale convective system (MCS), which attained an eventual horizontal dimension of approximately 100 by 200 km, are reported. Similarities in cloud structure within and outside the MCS include a downshear tilt of the cloud precipitation core and generation of new cells toward the direction of cloud motion and parallel to the major axis of the cloud line. The systematic difference in the longevity and intensity of the clouds is examined.

Knupp, Kevin R.↗

Kinematic and precipitation structure of a small, long-lived mesoscale convective system

A comprehensive analysis using conventional single Doppler radar analyses, analysis of multiparameter (CP-2) data, network sounding and surface data, and GOES satellite data is presented to characterize the internal kinematic and precipitation structure of a small, long-lived mesoscale convective system. The data pertain to the Cooperative Huntsville Meteorological experiment conducted over northern Alabama and central Tennessee during June and July of 1986. The mesoscale convective system pulsations visible in the IR patterns were associated with the development of closely interacting aggregates of convective elements. The aggregates were about 20 km in diameter, attained echo tops of about 13 km, and were dominated by a single relatively intense convective element. The measured difference in radial velocity across the upper portion of these elements was about 20 m/s over a distance of about 10 km.

Knupp, Kevin R.↗

Wave CISK and mesoscale convective systems

An examination is conducted of the basic assumptions of conventional wave-CISK theory, against observational data on mesoscale-organized convective systems. In response to the inadequacy of the quasi-equilibrium assumption, a nonequilibrium model of clouds actively responding to mesoscale low level mass fluxes in a preexisting and conditionally unstable atmosphere is formulated. The structures obtained for the propagating and growing waves are noted to be comparable with observations of midlatitude mesoscale convective systems. An examination is made of the energetics of this modified wave-CISK model, in order to deepen understanding of its instability and scale selection.

Xu, Q.↗

Vertical Structures of Anvil Clouds of Tropical Mesoscale Convective Systems Observed by CloudSat

A global study of the vertical structures of the clouds of tropical mesoscale convective systems (MCSs) has been carried out with data from the CloudSat Cloud Profiling Radar. Tropical MCSs are found to be dominated by cloud-top heights greater than 10 km. Secondary cloud layers sometimes occur in MCSs, but outside their primary raining cores. The secondary layers have tops at 6 8 and 1 3 km. High-topped clouds extend outward from raining cores of MCSs to form anvil clouds. Closest to the raining cores, the anvils tend to have broader distributions of reflectivity at all levels, with the modal values at higher reflectivity in their lower levels. Portions of anvil clouds far away from the raining core are thin and have narrow frequency distributions of reflectivity at all levels with overall weaker values. This difference likely reflects ice particle fallout and therefore cloud age. Reflectivity histograms of MCS anvil clouds vary little across the tropics, except that (i) in continental MCS anvils, broader distributions of reflectivity occur at the uppermost levels in the portions closest to active raining areas; (ii) the frequency of occurrence of stronger reflectivity in the upper part of anvils decreases faster with increasing distance in continental MCSs; and (iii) narrower-peaked ridges are prominent in reflectivity histograms of thick anvil clouds close to the raining areas of connected MCSs (superclusters). These global results are consistent with observations at ground sites and aircraft data. They present a comprehensive test dataset for models aiming to simulate process-based upper-level cloud structure around the tropics.

Hence, Deanna A.↗

Vertical Structures of Anvil Clouds of Tropical Mesoscale Convective Systems Observed by CloudSat

A global study of the vertical structures of the clouds of tropical mesoscale convective systems (MCSs) has been carried out with data from the CloudSat Cloud Profiling Radar. Tropical MCSs are found to be dominated by cloud-top heights greater than 10 km. Secondary cloud layers sometimes occur in MCSs, but outside their primary raining cores. The secondary layers have tops at 6--8 and 1--3 km. High-topped clouds extend outward from raining cores of MCSs to form anvil clouds. Closest to the raining cores, the anvils tend to have broader distributions of reflectivity at all levels, with the modal values at higher reflectivity in their lower levels. Portions of anvil clouds far away from the raining core are thin and have narrow frequency distributions of reflectivity at all levels with overall weaker values. This difference likely reflects ice particle fallout and therefore cloud age. Reflectivity histograms of MCS anvil clouds vary little across the tropics, except that (i) in continental MCS anvils, broader distributions of reflectivity occur at the uppermost levels in the portions closest to active raining areas; (ii) the frequency of occurrence of stronger reflectivity in the upper part of anvils decreases faster with increasing distance in continental MCSs; and (iii) narrower-peaked ridges are prominent in reflectivity histograms of thick anvil clouds close to the raining areas of connected MCSs (superclusters). These global results are consistent with observations at ground sites and aircraft data. They present a comprehensive test dataset for models aiming to simulate process-based upper-level cloud structure around the tropics.

Yuan, J.↗

Deep convection in mesoscale convective systems

A study was undertaken to examine the evolution of radar echoes and lightning attending the convective storms in mesoscale convective systems (MCS) and the relationships between the spatial and temporal evolution of deep convection and the storm environment, precipitation, severe weather, and lightning. The total number of ground discharges ranges from 10,000 to 30,000 over the life cycle of the MCS with peak sustained rates (for up to 10 consecutive hours) in excess of 2000 per hour. The peak lightning activity occurs from 5 to 20 hours after the first storms and anywhere from 7 hours prior to 7 hours after the time of the maximum areal extent of the MCS for very similar synoptic environments. Thus, it appears that mesoscale and sub-synoptic scale mechanisms are responsible for these large temporal variation in lightning activity. In addition, we have found that the lightning rates in MCS's are not related to either the size or the duration of the MCS. Preliminary results suggest that the MCA's with embedded squall lines produce the greatest flash rates.

Goodman, S. J.↗

Environment and evolution of a cold-frontal mesoscale convective system

Data obtained from the June 26-27, 1985 period of the Kansas-Oklahoma PRE-STORM field phase are employed to describe the evolution of a mesoscale convective system (MCS) responsible for a heavy rainfall event over a large portion of Oklahoma and Kansas. In the case examined, the eastward advancement of deep convection was aided by the formation of a series of nearly parallel rainbands before the main precipitation area. These rainbands, which developed in a field of boundary layer cloud streets, without the assistance of gust-front convergence, redefined the leading edge of the MCS and became the locus of the most intense convection in the precipitation system.

Trier, Stanley B.↗

An integrated view of the 1987 Australian monsoon and its mesoscale convective systems. II - Vertical structure

The vertical structure of monsoon thermal forcing by precipitating convection is diagnosed in terms of horizontal divergence. Airborne Doppler-radar divergence profiles from nine diverse mesoscale convective systems (MCSs) are presented. The MCSs consisted of multicellular convective elements which in time gave rise to areas of stratiform precipitation. Each of the three basic building blocks of the MCSs - convective, intermediary, and stratiform precipitation areas - has a consistent, characteristic divergence profile. Convective areas have low-level convergence, with its peak at 2-4 km altitude, and divergence above 6 km. Intermediary areas have convergence aloft, peaked near 10 km, feeding into mean ascent high in the upper troposphere. Stratiform areas have mid-level convergence, indicating a mesoscale downdraught below the melting level, and a mesoscale updraught aloft. Rawinsonde composite divergence profiles agree with the Doppler data in at least one important respect: the lower-tropospheric convergence into the MCSs peaks 2-4-km above the surface. Rawinsonde vorticity profiles show that monsoonal tropical cyclones spin-up at these elevated levels first, then later descend to the surface. Rawinsonde observations on a larger, continental scale demonstrate that at large horizontal scales only the 'gravest vertical mode' of MCS heating is felt, while the effects of shallower components of the heating (or divergence) profiles are trapped near the heating, as predicted by geostrophic adjustment theory.

Mapes, Brian↗

Backscatter-to-Extinction Ratios in the Top Layers of Tropical Mesoscale Convective Systems and in Isolated Cirrus from LITE Observations

Cloud-integrated attenuated backscatter from observations with the Lidar In-Space Technology Experiment (LITE) was studied over a range of cirrus clouds capping some extensive mesoscale convective systems (MCSS) in the Tropical West Pacific. The integrated backscatter when the cloud is completely attenuating, and when corrected for multiple scattering, is a measure of the cloud particle backscatter phase function. Four different cases of MCS were studied. The first was very large, very intense, and fully attenuating, with cloud tops extending to 17 km and a maximum lidar pulse penetration of about 3 km. It also exhibited the highest integrated attenuated isotropic backscatter, with values in the 532-nm channel of up to 2.5 near the center of the system, falling to 0.6 near the edges. The second MCS had cloud tops that extended to 14.8 km. Although MCS2 was almost fully attenuating, the pulse penetration into the cloud was up to 7 km and the MCS2 had a more diffuse appearance than MCS1. The integrated backscatter values were much lower in this system but with some systematic variations between 0.44 and 0.75. The third MCS was Typhoon Melissa. Values of integrated backscatter in tt-ds case varied from 1.64 near the eye of the typhoon to between 0.44 and 1.0 in the areas of typhoon outflow and in the 532-nm channel. Mean pulse penetration through the cloud top was 2-3 km, the lowest penetration of any of the systems. The fourth MCS consisted of a region of outflow from Typhoon Melissa. The cloud was semitransparent for more than half of the image time. During that time, maximum cloud depth was about 7 km. The integrated backscatter varied from about 0.38 to 0.63 in the 532-nm channel when the cloud was fully attenuating. In some isolated cirrus between the main systems, a plot of integrated backscatter against one minus the two-way transmittance gave a linear dependence with a maximum value of 0.35 when the clouds were fully attenuating. The effective backscatter-to-extinction ratios, when allowing for different multiple-scattering factors from space, were often within the range of those observed with ground-based lidar. Exceptions occurred near the centers of the most intense convection, where values were measured that were considerably higher than those in cirrus observed from the surface. In this case, the values were more compatible with theoretical values for perfectly formed hexagonal columns or plates. The large range in theoretically calculated back- scatter-to-extinction ratio and integrated multiple-scattering factor precluded a closer interpretation in terms of cloud microphysics.

Platt, C. M. R.↗

Cloud-to-ground lightning and rainfall volumes in mesoscale convective systems

The relationship between cloud-to-ground lightning and surface rainfall estimates for the southern Great Plains during the spring 1985 PRE-STORM project is examined to determine if consistent relationships between these two parameters exist in this area. Understanding the relationships will permit the development of lightning-rainfall algorithms applicable to this region and other climatic areas. The radar data collected during this project provided good temporal and spatial coverage of several mesoscale convective systems from their incipient through mature stages and on to decay with temporal sampling at 10 to 12 minute intervals.

Nielsen, Kurt E.↗

Large Charge Moment Change Lightning in an Oklahoma Mesoscale Convective System

On 31 May 2013, a line of severe thunderstorms developed during the local afternoon in central Oklahoma, USA. One of the supercells produced the El Reno tornado, which caused significant damage and killed several people. During the 2300 UTC hour (during the mature supercell stage and just after the tornado began), the storm produced several positive cloud-to-ground (+CG) lightning strokes that featured large (> 75 C km) impulse charge moment changes (iCMCs - charge moment during the first 2 ms after the return stroke). These discharges occurred mainly in convection, in contrast to the typical pattern of large-CMC and sprite-parent +CGs occurring mainly in stratiform precipitation regions. After this time, the line of thunderstorms evolved over several hours into a large mesoscale convective system (MCS). By the 0700 UTC hour on 1 June 2013, the large- CMC pattern had changed markedly. Large-CMC negative CGs, which were absent early in the storm's lifetime, occurred frequently within convection. Meanwhile, large- CMC +CGs had switched to occurring mainly within the broad stratiform region that had developed during the intervening period. The evolution of the large-CMC lightning in this case will be examined using a mix of polarimetric data from individual radars, national mosaics of radar reflectivity, the Oklahoma Lightning Mapping Array (OKLMA), the Charge Moment Change Network (CMCN), and the National Lightning Detection Network (NLDN). A major goal of this study is understanding how storm structure and evolution affected the production of large-CMC lightning. It is anticipated that this will lead to further insight into how and why storms produce the powerful lightning that commonly causes sprites in the upper atmosphere.

Lang, Timothy J.↗

Large Charge Moment Change Lightning in an Oklahoma Mesoscale Convective System

On 31 May 2013, a line of severe thunderstorms developed during the local afternoon in central Oklahoma, USA. One of the supercells produced the El Reno tornado, which caused significant damage and killed several people. During the 2300 UTC hour (during the mature supercell stage and just after the tornado began), the storm produced several positive cloud-to-ground (+CG) lightning strokes that featured large (> 100 C km) impulse charge moment changes (iCMCs; charge moment during the first 2 ms after the return stroke). These discharges occurred mainly in convection, in contrast to the typical pattern of large-CMC and sprite-parent +CGs occurring mainly in stratiform precipitation regions. After this time, the line of thunderstorms evolved over several hours into a large mesoscale convective system (MCS). By the 0700 UTC hour on 1 June 2013, the large-CMC pattern had changed markedly. Large-CMC negative CGs, which were absent early in the storm's lifetime, occurred frequently within convection. Meanwhile, large-CMC +CGs had switched to occurring mainly within the broad stratiform region that had developed during the intervening period. The evolution of the large-CMC lightning in this case will be examined using a mix of national mosaics of radar reflectivity, the Oklahoma Lightning Mapping Array (OKLMA), the Charge Moment Change Network (CMCN), and the National Lightning Detection Network (NLDN). A major goal of this study is understanding how storm structure and evolution affected the production of large-CMC lightning. It is anticipated that this will lead to further insight into how and why storms produce the powerful lightning that commonly causes sprites in the upper atmosphere.

Lang, Timothy J.↗