Energy transduction in Halobacterium halobium

The properties and functions of the light-energy-transducing purple membrane of Halobacterium halobium are reviewed. Consideration is given to the protein structure and composition of the membrane and the photochemistry of the protein-retinal complex known as bacteriorhodopsin. The role of bacteriorhodpsin in establishing and maintaining an electrochemical (H(+)) gradient is examined, and interactions of this gradient with Na(+) and K(+) gradients, the light-induced transport of amino acids and the light-induced phosphorylation of ADP are considered. Bacteriorhodopsin and the respiratory chain are discussed as alternative sources of energy for the maintenance of the H(+) gradient. Advantages of the Halobacterium purple membrane system for studies of membrane energetics and the confirmation of the chemiosmotic hypothesis are also noted.

Lanyi, J. K.↗

Utilization of membranes for H2O recycle system

Conceptual studies of closed ecological life support systems (CELSS) carried out at NAL in Japan for a water recycle system using membranes are reviewed. The system will treat water from shower room, urine, impure condensation from gas recycle system, and so on. The H2O recycle system is composed of prefilter, ultrafiltration membrane, reverse osmosis membrane, and distillator. Some results are shown for a bullet train of toilet-flushing water recycle equipment with an ultraviltration membrane module. The constant value of the permeation rate with a 4.7 square meters of module is about 70 1/h after 500th of operation. Thermovaporization with porous polytetrafluorocarbon membrane is also proposed to replce the distillator.

Ohya, H.↗

Microgravity Transport Phenomena Experiment (MTPE) Overview

The Microgravity Transport Phenomena Experiment (MTPE) is a fluids experiment supported by the Fundamentals in Biotechnology program in association with the Human Exploration and Development of Space (BEDS) initiative. The MTP Experiment will investigate fluid transport phenomena both in ground based experiments and in the microgravity environment. Many fluid transport processes are affected by gravity. Osmotic flux kinetics in planar membrane systems have been shown to be influenced by gravimetric orientation, either through convective mixing caused by unstably stratified fluid layers, or through a stable fluid boundary layer structure that forms in association with the membrane. Coupled transport phenomena also show gravity related effects. Coefficients associated with coupled transport processes are defined in terms of a steady state condition. Buoyancy (gravity) driven convection interferes with the attainment of steady state, and the measurement of coupled processes. The MTP Experiment measures the kinetics of molecular migration that occurs in fluids, in response to the application of various driving potentials. Three separate driving potentials may be applied to the MTP Experiment fluids, either singly or in combination. The driving potentials include chemical potential, thermal potential, and electrical potential. Two separate fluid arrangements are used to study membrane mediated and bulk fluid transport phenomena. Transport processes of interest in membrane mediated systems include diffusion, osmosis, and streaming potential. Bulk fluid processes of interest include coupled phenomena such as the Soret Effect, Dufour Effect, Donnan Effect, and thermal diffusion potential. MTP Experiments are performed in the Microgravity Transport Apparatus (MTA), an instrument that has been developed specifically for precision measurement of transport processes. Experiment fluids are contained within the MTA fluid cells, designed to create a one dimensional flow geometry of constant cross sectional area, and to facilitate fluid filling and draining operations in microgravity. The fluid cells may be used singly for bulk solutions, or in a Stokes diaphragm configuration to investigate membrane mediated phenomena. Thermal and electrical driving potentials are applied to the experiment fluids through boundary plates located at the ends of the fluid cells. In the ground based instrument, two constant temperature baths circulate through reservoirs adjacent to the boundary plates, and establish the thermal environment within the fluid cells. The boundary plates also serve as electrodes for measurement and application of electrical potentials. The Fluid Manipulation System associated with the MTA is a computer controlled system that enables storage and transfer of experiment fluids during on orbit operations. The system is used to automatically initiate experiments and manipulate fluids by orchestrating pump and valve operations through scripted sequences. Unique technologies are incorporated in the MTA for measurement of fluid properties. Volumetric Flow Sensors have been developed for precision measurement of total fluid volume contained within the fluid cells over time. This data is most useful for measuring the kinetics of osmosis, where fluid is transported from one fluid cell to another through a semipermeable membrane. The MicroSensor Array has been designed to perform in situ measurement of several important fluid parameters, providing simultaneous measurement of solution composition at multiple locations within the experiment fluids. Micromachined sensors and interface electronics have been developed to measure temperature, electrical conductivity, pH, cation activity, and anion activity. The Profile Refractometer uses a laser optical system to directly image the fluid Index of Refraction profile that exists along the MTA fluid cell axis. A video system acquires images of the RI profile over time, and records the transport kinetics that occur upon application of chemical, thermal, or electrical driving potentials. Image processing algorithms have been developed to analyze the refractometer images on a pixel by pixel basis, calibrating and scaling the measured Index of Refraction profile to correlated solution properties of interest such as density, concentration, and temperature. Additional software has been developed to compile the processed images into a three dimensional matrix that contains fluid composition data as a function of experiment time and position in the fluid cell. These data are combined with data from the other sensor systems, and analyzed in the context of transport coefficients associated with the various transport phenomena. Analysis protocols have been developed to measure the transient kinetics, and steady state distribution of fluid components that occur in response to the applied driving potentials. The results are expressed in terms of effective transport coefficients. Experiments have been performed using a variety of solutes, and results generated are that are in agreement with published transport coefficient values.

Mason, Larry W.↗

FOST 2 Upgrade with Hollow-Fiber CTA FO Module and Generation of Osmotic Agent for Microorganism Growth Studies

FOST 2 is an integrated membrane system that incorporates a forward osmosis subsystem and a reverse osmosis subsystem working in series. It has been designed as a post treatment system to process the effluent from the Membrane Aerated Biological Reactor developed at NASA Johnson Space Center and Texas Tech University. Its function is to remove dissolved solids residual such as ammonia and suspended solids, as well as to provide a physical barrier to microbial and viral contamination. A tubular CTA membrane module from HTI and a flat-sheet lipid-base membrane module from Porifera were integrated and tested on FOST 2 in the past, using both a bioreactor's effluent and greywater as the feed solution. This paper documents the performance of FOST 2 after its upgrade with a hollow-fiber CTA membrane module from Toyobo, treating real black-water to generate the osmotic agent solution necessary to conduct growth studies of genetically engineered microorganism for the Synthetic Biological Membrane project.

Water treatment↗

Anion permselective membrane

The efforts on the synthesis of polymer anion redox membranes were mainly concentrated in two areas, membrane development and membrane fabrication. Membrane development covered the preparation and evaluation of experimental membranes systems with improved resistance stability and/or lower permeability. Membrane fabrication covered the laboratory scale production of prime candidate membranes in quantities of up to two hundred and sizes up to 18 inches x 18 inches (46 cm x 46 cm). These small (10 in x 11 in) and medium sized membranes were mainly for assembly into multicell units. Improvements in processing procedures and techniques for preparing such membrane sets lifted yields to over 90 percent.

Hodgdon, R. B.↗

A 4-node Bilinear Isoparametric Element in Rockwell NASTRAN

The development and evaluation of the Rockwell NASTRAN four node quadrilateral (QUAD4) element is presented. The element derivation utilizes bilinear isoparametric techniques both for membrane and bending characteristics. The QUAD4 element coordinate system, membrane properties, lumped mass matrix, and treatment of warping are based upon the COSMIC/NASTRAN QDMEMI element while the bending characteristics are based on a paper by T. J. R. Hughes. The effects of warping on the bending stiffness, consistent mass, and geometric stiffness are based upon a paper by R. H. MacNeal. Numerical integration is accomplished by Gaussian quadrature on a 2 x 2 grid. Practical user support features include variable element thickness, thermal analysis and layered composite material definitions.

Liao, C.↗

The development of inflatable array antennas

The deployable array antenna using an inflatable or thin-membrane structure has been identified as one of the enabling technologies to achieve low-mass, high packaging efficiency, low cost, and reliable deployment for future NASNJPL spacebome high-gain and large aperture antennas. Array antennas, when compared to parabolic reflectors, although suffering from limited bandwidth performance, offer wide-angle beam scanning capability and a more reliable flat “natural” aperture. To demonstrate the feasibility and capability of this low-mass array technology, three antenna concepts using inflatable and thin-membrane structures were initiated in 1997 at JPL and several breadboard units have been successfully developed. These three concepts are (1) the inflatable phased array, (2) the inflatable reflectarray, and (3) frame-supported thin membrane array antenna. All three concepts utilize the printed microstrip antenna technology. Although all three concepts will be briefly presented, this paper will discuss in more detail of the recent development of the second concept. The first concept of inflatable phased arrays that have been constructed are 3 to 5-meter size L-band dual-polarized synthetic aperture radar (SAR) arrays for Earth remote sensing application. They all consist of a rectangular configuration with inflatable cylindrical tubes that support and tension a multi-layer thin-membrane radiating aperture with microstrip patches and microstrip power divider lines. For the second concept, an inflatable reflectarray was developed for future deep-space telecom applications. It is a 3m Ka-band inflatable reflectarray (1.8 kg/m2). This reflectarray uses inflated torus tubes to support and tension a flat-membrane reflectarray surface. The reflectarray surface emulates a curved parabolic reflecting surface. However, because of its flat surface being a “natural surface”, it is much easier to achieve and more reliable to maintain the required surface tolerance than that of a curved parabola during long space flight. For the third concept, an L-band dual polarized SAR array with a 5m x 3m aperture and 2.5 kg/m2 of mass has recently been demonstrated. It consists of seven foldable panels each having a rectangular frame that supports a two-layer thinmembrane microstrip subarray aperture. Each frame is made of light-weight graphite composite material. The chief advantage of this deployable “frame” concept is that each frame is able to rigidly support an appropriate number of T/R modules and phase shifters to achieve the desired power distribution and beam scanning. Several technology challenges, such as the development of rigidizable inflatable tubes, a controlled deployment mechanism, thin-membrane thermal effects, a low-mass inflation system, membrane mounted T/R modules, means to counter surface tolerance issues, etc. are being investigated and will be discussed in the presentation. With foreseeable success in the development of these challenging areas, the inflatable/thin-membrane array antennas could be mature enough in a few years for actual space flight.

Lou, Michael↗

Calculating Free Energies Using Scaled-Force Molecular Dynamics Algorithm

One common objective of molecular simulations in chemistry and biology is to calculate the free energy difference between different states of the system of interest. Examples of problems that have such an objective are calculations of receptor-ligand or protein-drug interactions, associations of molecules in response to hydrophobic, and electrostatic interactions or partition of molecules between immiscible liquids. Another common objective is to describe evolution of the system towards a low energy (possibly the global minimum energy), 'native' state. Perhaps the best example of such a problem is folding of proteins or short RNA molecules. Both types of problems share the same difficulty. Often, different states of the system are separated by high energy barriers, which implies that transitions between these states are rare events. This, in turn, can greatly impede exploration of phase space. In some instances this can lead to 'quasi non-ergodicity', whereby a part of phase space is inaccessible on timescales of the simulation. A host of strategies has been developed to improve efficiency of sampling the phase space. For example, some Monte Carlo techniques involve large steps which move the system between low-energy regions in phase space without the need for sampling the configurations corresponding to energy barriers (J-walking). Most strategies, however, rely on modifying probabilities of sampling low and high-energy regions in phase space such that transitions between states of interest are encouraged. Perhaps the simplest implementation of this strategy is to increase the temperature of the system. This approach was successfully used to identify denaturation pathways in several proteins, but it is clearly not applicable to protein folding. It is also not a successful method for determining free energy differences. Finally, the approach is likely to fail for systems with co-existing phases, such as water-membrane systems, because it may lead to spontaneous mixing. A similar difficulty may be encountered in any method relying on global modifications of phase space.

Darve, Eric↗

Evaluation of 165 deg F reverse osmosis modules for washwater purification.

Three membrane systems have been evaluated for concentration at 165 F of wash-water contaminants. Membranes tested are polybenzimidazole (hollow fibers), cellulose acetate blend (spiral wound), and sulfonated polyphenylene oxide (plate-and-frame). Detailed membrane flux and rejection data are presented for 200-hr life tests with synthetic wash water, at two concentrations, and real wash water, at one concentration. Advantages and limitations of the membrane configurations, are discussed.

Hossain, S.↗

Buffer Gas Acquisition and Storage

The acquisition and storage of buffer gases (primarily argon and nitrogen) from the Mars atmosphere provides a valuable resource for blanketing and pressurizing fuel tanks and as a buffer gas for breathing air for manned missions. During the acquisition of carbon dioxide (CO2), whether by sorption bed or cryo-freezer, the accompanying buffer gases build up in the carbon dioxide acquisition system, reduce the flow of CO2 to the bed, and lower system efficiency. It is this build up of buffer gases that provide a convenient source, which must be removed, for efficient capture Of CO2 Removal of this buffer gas barrier greatly improves the charging rate of the CO2 acquisition bed and, thereby, maintains the fuel production rates required for a successful mission. Consequently, the acquisition, purification, and storage of these buffer gases are important goals of ISRU plans. Purity of the buffer gases is a concern e.g., if the CO, freezer operates at 140 K, the composition of the inert gas would be approximately 21 percent CO2, 50 percent nitrogen, and 29 percent argon. Although there are several approaches that could be used, this effort focused on a hollow-fiber membrane (HFM) separation method. This study measured the permeation rates of CO2, nitrogen (ND, and argon (Ar) through a multiple-membrane system and the individual membranes from room temperature to 193K and 10 kpa to 300 kPa. Concentrations were measured with a gas chromatograph that used a thermoconductivity (TCD) detector with helium (He) as the carrier gas. The general trend as the temperature was lowered was for the membranes to become more selective, In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar.

Parrish, Clyde F.↗

Analysis and Ground Testing for Validation of the Inflatable Sunshield in Space (ISIS) Experiment

The Next Generation Space Telescope (NGST) design requires a large sunshield to protect the large aperture mirror and instrument module from constant solar exposure at its L2 orbit. The structural dynamics of the sunshield must be modeled in order to predict disturbances to the observatory attitude control system and gauge effects on the line of site jitter. Models of large, non-linear membrane systems are not well understood and have not been successfully demonstrated. To answer questions about sunshield dynamic behavior and demonstrate controlled deployment, the NGST project is flying a Pathfinder experiment, the Inflatable Sunshield in Space (ISIS). This paper discusses in detail the modeling and ground-testing efforts performed at the Goddard Space Flight Center to: validate analytical tools for characterizing the dynamic behavior of the deployed sunshield, qualify the experiment for the Space Shuttle, and verify the functionality of the system. Included in the discussion will be test parameters, test setups, problems encountered, and test results.

Lienard, Sebastien↗

Contaminant Permeation in the Ionomer-Membrane Water Processor (IWP) System

The Ionomer-membrane Water Processor (IWP) is a patented membrane-distillation based urine brine water recovery system. The unique properties of the IWP membrane pair limit contaminant permeation from the brine to the recovered water and purge gas. A paper study was conducted to predict volatile trace contaminant permeation in the IWP system. Testing of a large-scale IWP Engineering Development Unit (EDU) with urine brine pretreated with the International Space Station (ISS) pretreatment formulation was then conducted to collect air and water samples for quality analysis. Distillate water quality and purge air GC-MS results are presented and compared to predictions, along with implications for the IWP brine processing system.

Kelsey, Laura K.↗

Anton permselective membrane

Experimental composite membranes were synthesized on a lab scale consisting of a thin layer of anion permselective resin supported by and bonded to a porous physically strong and conductive substrate film. These showed good selectivity and also substantially lower electrical resistivities than the homogenous candidate membranes optimized in the previous contract. A wide range of resin porosities were examined for three candidate membrane systems, CDIL, CP4L, and A3L to identify the formulation giving the best overall redox cell performance. Candidate anion membranes showed large increases in resistivity after a short time of immersion in concentrated FeCl/HCl solution. Largely on the basis of resistance stability the CDIL formulation was selected as prime candidate and about thirty-five membranes (one foot square) were produced for experimental static and dynamic evaluation.

Alexander, S. S.↗

Test results on reuse of reclaimed shower water - A summary

Results are presented from tests to evaluate a microgravity whole body shower and waste water recovery system design for possible use on the Space Station. Several water recovery methods were tested, including phase change distillation, a thermoelectric hollow fiber membrane evaporation subsystem, and a reverse osmosis dynamic membrane system. Consideration is given to the test hardware, the types of soaps evaluated, the human response to showering with reclaimed water, chemical treatment for microbial control, the procedures for providing hygienic water, and the quality of water produced by the systems. All three of the waste water recovery systems tested successfully produced reclaimed water for reuse.

Verostko, Charles E.↗

Long Term Biological Treatment of Space Habitation Waste Waters in a One Stage MABR: Comparison of Operation for N and C Oxidation With and Without Simultaneous Denitrification

Aerobic biological stabilization has been previously demonstrated for full size MABR?s (CoMANDR 1.0, CoMANDR 2.0, and R-CoMANDR) over operating periods of ~1 year. These systems have successfully treated a variety of possible habitation waste streams including an ISS (urine + flush and humidity condensate) and Early Planetary Base (EPB) wastewater (urine, flush water, hygiene wastewater, and laundry). Biological stabilization has a number of advantages including: 1) elimination of hazardous pre-treat chemicals; 2) production of NOx species (that can be easily rejected by evaporative or membrane systems); 3) elimination of volatile organic constituents; 4) a low pH effluent that facilitates membrane and distillation processes; and 5) a effluent that produces a better quality and less hazardous brine for water recovery. Previous work has primarily evaluated aerobic operation in which organic carbon and nitrogen is converted to CO2 and NOx-, respectively. An alternative to aerobic operation would be to include anoxic operation to promote denitrification and production of N2 gas. This allows for production of make-up gas as well as reduces the O2 demand and can increase ammonia oxidation efficiency. We evaluated the operation of a full scale (2 crew/day) MABR operated to perform oxidation of organic carbon and nitrogen with and without simultaneous reduction of oxidized N to N2 gas, simultaneous nitrification denitrification (SNDN). The system was challenged with a variety of space habitation wastewaters ranging from an ISS composition to a possible EPB waste stream under both continuous and on-production feeding modes. The system has been operated for over 2.5 years. We report on an overall comparison of aerobic oxidation and SNDN operational regimes to evaluate the system with the best overall attributes to support recycling of space habitation waste streams.

Biological water processing↗

Peptides at Membrane Surfaces and their Role in Prebiotic Evolution

Protocells had to transport ions and organic matter across membranes separating the interior of the cell from the environment, capture and utilize energy and transduce environmental signals. In a series of detailed, molecular-level computer simulations we show how these peptides in contact with membranes can acquire ordered structures and functions. We have investigated the stability of a simple alpha-helical peptide containing Leucine (L) and Serine (S) of the form (LSLLLSL)3 in a model membrane system. The parallel in-plane state is the most stable configuration. The transmembrane state is metastable, and about 15 kcal/mol is required to insert the peptide into the membrane. We investigated dimes of both (LSLLLSL)3 and glycophorin A, and show how the free energy of helix association can, at least partially, offset the free energy of insertion. We have also investigated the transmembrane pore of the influenza M2 protein. This aggregate of four identical alpha-helices, each built of 25 amino acids, forms an efficient and selective voltage-gated proton channel. Our simulations explain the gating mechanism, which can involve strands of hydrogen-bonded water through the pore or proton transfer through tautomerization of protein residues. The channel can be re-engineered to act as a simple proton pump.

Pohorille, Andrew↗

The application of Dow Chemical's perfluorinated membranes in proton-exchange membrane fuel cells

Dow Chemical's research activities in fuel cell devices revolves around the development and subsequent investigation of the perfluorinated inomeric membrane separator useful in proton-exchange membrane systems. Work is currently focusing on studying the effects of equivalent weight, thickness, water of hydration, pretreatment procedures, as well as the degree of water management required for a given membrane separator in the cell. The presentation will include details of certain aspects of the above as well as some of the requirements for high and low power generation.

Eisman, G. A.↗