Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical radioisotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radioisotope production at the Spallation Neutron Source: Design concept of isotope production target

Upon completion of the Second Target Station (STS) Project in the mid 2030s, the Spallation Neutron Source accelerator at Oak Ridge National Laboratory will deliver a 2.7 MW proton beam to the neutron production targets. In the post-STS phase, the accelerator will have a reserve beam power capacity of at least 100 kW beyond what the two neutron production targets will receive, which could potentially be ramped up to 300 kW. In this paper, a design concept for a radioisotope production target that could utilize 250 kW of the reserve beam power capacity is presented. The target consists of thorium discs encapsulated in 316L austenitic steel shells that are cooled by water. The estimated post-irradiation activity of Ac-225 and Ra-225, critical medical radioisotopes used in targeted alpha therapy cancer treatment, is calculated at the end of bombardment after a 14 day long irradiation time. Thermal and structural analyses are performed on the basis of calculated nuclear heating data. The technical feasibility of a high-power target under a 250-kW beam load with an extremely low duty factor of $3.5\cdot 10^{-6}$ is presented from thermal, structural and fatigue lifetime perspectives.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Razorback – A reactor transient analysis code for large rapid reactivity additions in a natural circulation research reactor

Research reactors play an important role in higher education, scientific research, and medical radioisotope production around the world. It is thus important to ensure the safety of facility workers and the public. This work presents a new reactor transient analysis code referred to as Razorback. The code has been developed for the evaluation of large rapid reactivity addition in research reactors. Its initial focus is the Annular Core Research Reactor (ACRR) at Sandia National Laboratories. Results have been validated against ACRR pulse operations. Razorback models the reactor kinetics, fuel element heat transfer, fuel element thermal expansion, and natural circulation coolant channel thermal-hydraulic response. Simulation results for ACRR pulse operations are shown to agree very well with operational data obtained from the ACRR. Finally, Razorback is expected to be a valuable tool for ACRR pulse performance prediction and ACRR reactor safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Photon Activation Analysis in Gallium, Nickel, and Vanadium

Here this research explored the development of the photonuclear production method of 67 Cu from 71 Ga as well as 47 Sc from 51 V. Both products serve as high-demand research medical radioisotopes. Furthermore, an understanding of these reactions is significant to fundamental nuclear physics and astrophysics. Bremsstrahlung flux was induced by an electron linac and a 1-mm tungsten radiator. Irradiation of gallium oxide powder, 98.78% pure 71 Ga, and a natural vanadium foil at 30.9 MeV and 100 W for 1 h produced 64.4 ± 0.4 Bq/W·s·kg of 67 Cu and 164 ± 3.1 Bq/W·s·kg of 47 Sc. A secondary irradiation with 99.6% pure 71 Ga and natural vanadium at 31.5 MeV and 100 W for 1.1 h produced 79.8 ± 0.9 Bq/W·s·kg of 67 Cu and 136 ± 7.2 Bq/W·s·kg of 47 Sc. The photoinduced activation is promising; however, further research into optimal geometry and power is required to maximize specific activity. Natural nickel was also irradiated to serve as a benchmark comparison. Effective cross sections for each reaction were inferred.

47Sc↗

Building Interfaces with Echo Using R

The following report details the functionality that was developed to directly query the MongoDB and read in echo records from within R, and the ability to create a cinema database directly from echo records. Both of these efforts used the data collected under the MINOS project for development. The nuclear facility under consideration is the High-Flux Isotope Reactor (HFIR) and co-located Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory in Oak Ridge, TN. HFIR is an 85 MW research reactor and is used primarily for production of a medical radioisotopes, material irradiation experiments, neutron activation, and neutron scattering. Targets for the reactor are fabricated and processed and dissolved at REDC, in addition to other glove-box and hot-cell type activities. An overhead view of the facility is provided. The rest of the report is organized as follows: Section 2 describes how to query the MongoDB and load in echo records from within R, with background information on the database type, MongoDB, and the file format of echo records, hdf5, as well as lessons learned during the development phase. Section 3 details the functionality and usage of creating a cinema database directly from echo records within R. A series of appendixes display all the R code (Section 5), some example scripts where the code is used (Section 6), and useful links for further exploration (Section 7).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MINOS Infrasound Analysis Synopsis

This report was written as a guide to working with infrasound data collected as part of the Multi-Informatics for Nuclear Operations Scenarios (MINOS)project, an NA-22 funded venture. The main purpose of overall MINOS project is the combination of multiple, disparate data modalities to characterize the operations at a nuclear facility, specifically instrumenting and studying the High-Flux Isotope Reactor (HFIR) and Radiochemical Engineering Development Center (REDC) locate at Oak Ridge National Laboratory in Oak Ridge, TN. HFIR is an 85 MW research reactor and is used primarily for production of medical radioisotopes, material irradiation experiments, neutron activation, and neutron scattering. Targets for the reactor are constructed, processed, and dissolved at REDC. REDC also hosts other glove-box and hot-cell type activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery and Recycle of Irradiated Low-Enriched Uranium from the Production of 99 Mo

Technetium-99m ( 99m Tc), the daughter (decay product) of molybdenum-99 ( 99 Mo), is the most commonly used medical radioisotope in the world. 99 Mo is produced primarily from the fissioning of 235 U. A potential future producer, Eden Radioisotopes, is planning to irradiate low-enriched-uranium metal-foil targets for production of 99 Mo. Their plan is to recover, purify, and recycle the irradiated LEU in a new set of targets inside their facility. This study assesses processes to (1) purify and recycle uranium following 99 Mo recovery and (2) convert the uranium to metal for subsequent foil production and target fabrication. A UREX (uranium recovery by extraction) liquid–liquid extraction flowsheet that utilizes centrifugal contactors was developed using the Argonne model for universal solvent extraction (AMUSE) to recover and purify the uranium. The calculated flowsheet predicted high decontamination from Pu and most fission products and >99.99% recovery of uranium. Suggestions for conversion of the UREX U-product (uranyl nitrate in dilute nitric acid) to U metal were provided based on literature studies and earlier laboratory studies performed at Argonne National Laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

Looking back at 50 years of cutting-edge capabilities: LANSCE ‘underpins Los Alamos as a world-class scientific institution’

What started with an idea and a memo has since grown into a one-of-a-kind, world-renowned facility that contributes to the nation’s advancement of science and technology. First known as LAMPF (Los Alamos Meson Physics Facility) until the 1990s when it became LANSCE (Los Alamos Neutron Science Center), the facility is celebrating the 50th anniversary of its first full-capacity proton beam on June 9, 1972. Since then, LANSCE has contributed to a range of national security goals, such as supporting the Lab’s stockpile stewardship program, helping to advance the science of medical radioisotopes, improving the understanding of hydrodynamics, and more. “LANSCE has served the nation through its near-unique capabilities,” said Alan Carr, Senior Historian at the National Security Research Center, which houses the facility’s evolution through decades of documents, photos and other materials. “Since 1972, LANSCE has been the Lab’s major experimental science facility and underpins Los Alamos as a world-class scientific institution. This was true 50 years ago and is still true today.” In commemoration of this anniversary, we’re taking a look back at LANSCE’s historic five decades, including its first director, earliest milestones and important contributions to national security.

43 PARTICLE ACCELERATORS↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

Pulsed Beam Heating Analysis of Curved Inconel Window with Pressurized Helium Gas Cooling

Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using Rodotron electron accelerators. Two Rhodotron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 discs. LANL simulates the beam heating using an induction heater.

07 ISOTOPE AND RADIATION SOURCES↗

Status of Additive Manufacturing Capabilities for Processing Refractory Alloys Under the Mo-99 Program

The enriched 100 Mo target, denoted as aMo, that Northstar Medical Radioisotopes is developing to produce 99 Mo from an accelerator-based method is a disk-type geometry with a 0.5–0.715 mm thickness and a 29 mm outer diameter. A press and sinter method was adopted to fabricate these samples from aMo powder feedstock. Inherent porosity from the press and sinter method makes the disks more easily dissolvable during 99 Mo postprocessing. However, the disk-type geometry will be subject to thermal stresses due to temperature variations once the geometry is in line with the accelerated electron beam, causing warping and possible failure. Additive manufacturing (AM) processes such as laser powder bed fusion (LPBF) enable the manufacturing of custom, complex geometries that may otherwise be difficult to produce with more conventional methods (e.g., press and sinter approach). Therefore, the National Nuclear Security Administration’s Molybdenum-99 Program invested in developing an AM facility dedicated to processing and printing refractory powders. This report details the LPBF process, how irregular refractory powder can be prepared for LPBF, and the equipment that is available to support the program.

36 MATERIALS SCIENCE↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies using Pulsed Beam Heating

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using electron accelerators. Two electron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 disks. LANL simulates the beam heating using an induction heater.

43 PARTICLE ACCELERATORS↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Flow Measurements in Pressurized Helium Gas Cooling Channels: Rev. 1

Compressed helium gas is used to cool the NorthStar Medical Radioisotope (NMR) target system, also called the trident, chosen due to its superior heat transfer capabilities and its inability to react with Molybdenum-100 (Mo-100) during irradiation. To test the housing and NMR target stack at Los Alamos National Laboratory (LANL), two sets of helium gas flow loop facilities have been set-up and tested. One system is used for bench-top experiments to systematically investigate individual components of the NMR target, and the other, larger system is more representative of the system at NMR and is used for testing the full NMR target stack.

43 PARTICLE ACCELERATORS↗